Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am J Physiol Heart Circ Physiol ; 326(5): H1094-H1104, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38426864

RESUMEN

Obstructive sleep apnea (OSA) is associated with the progression of cardiovascular diseases, arrhythmias, and sudden cardiac death (SCD). However, the acute impacts of OSA and its consequences on heart function are not yet fully elucidated. We hypothesized that desaturation events acutely destabilize ventricular repolarization, and the presence of accompanying arousals magnifies this destabilization. Ventricular repolarization lability measures, comprising heart rate corrected QT (QTc), short-time-variability of QT (STVQT), and QT variability index (QTVI), were calculated before, during, and after 20,955 desaturations from lead II electrocardiography signals of 492 patients with suspected OSA (52% men). Variations in repolarization parameters were assessed during and after desaturations, both with and without accompanying arousals, and groupwise comparisons were performed based on desaturation duration and depth. Regression analyses were used to investigate the influence of confounding factors, comorbidities, and medications. The standard deviation (SD) of QT, mean QTc, SDQTc, and STVQT increased significantly (P < 0.01), whereas QTVI decreased (P < 0.01) during and after desaturations. The changes in SDQT, mean QTc, SDQTc, and QTVI were significantly amplified (P < 0.01) in the presence of accompanying arousals. Desaturation depth was an independent predictor of increased SDQTc (ß = 0.405, P < 0.01), STVQT (ß = 0.151, P < 0.01), and QTVI (ß = 0.009, P < 0.01) during desaturation. Desaturations cause acute changes in ventricular repolarization, with deeper desaturations and accompanying arousals independently contributing to increased ventricular repolarization lability. This may partially explain the increased risk of arrhythmias and SCD in patients with OSA, especially when the OSA phenotype includes high hypoxic load and fragmented sleep.NEW & NOTEWORTHY Nocturnal desaturations are associated with increased ventricular repolarization lability. Deeper desaturations with accompanying arousals increase the magnitude of alterations, independent of confounding factors, comorbidities, and medications. Changes associated with desaturations can partially explain the increased risk of arrhythmias and sudden cardiac death in patients with OSA, especially in patients with high hypoxic load and fragmented sleep. This highlights the importance of detailed electrocardiogram analytics for patients with OSA.


Asunto(s)
Arritmias Cardíacas , Apnea Obstructiva del Sueño , Masculino , Humanos , Femenino , Muerte Súbita Cardíaca/etiología , Apnea Obstructiva del Sueño/complicaciones , Nivel de Alerta , Electrocardiografía/efectos adversos , Frecuencia Cardíaca/fisiología , Hipoxia/complicaciones
2.
Mult Scler ; 30(1): 103-112, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38084497

RESUMEN

INTRODUCTION: Multiple sclerosis (MS) is a leading cause of disability among young adults, but standard clinical scales may not accurately detect subtle changes in disability occurring between visits. This study aims to explore whether wearable device data provides more granular and objective measures of disability progression in MS. METHODS: Remote Assessment of Disease and Relapse in Central Nervous System Disorders (RADAR-CNS) is a longitudinal multicenter observational study in which 400 MS patients have been recruited since June 2018 and prospectively followed up for 24 months. Monitoring of patients included standard clinical visits with assessment of disability through use of the Expanded Disability Status Scale (EDSS), 6-minute walking test (6MWT) and timed 25-foot walk (T25FW), as well as remote monitoring through the use of a Fitbit. RESULTS: Among the 306 patients who completed the study (mean age, 45.6 years; females 67%), confirmed disability progression defined by the EDSS was observed in 74 patients, who had approximately 1392 fewer daily steps than patients without disability progression. However, the decrease in the number of steps experienced over time by patients with EDSS progression and stable patients was not significantly different. Similar results were obtained with disability progression defined by the 6MWT and the T25FW. CONCLUSION: The use of continuous activity monitoring holds great promise as a sensitive and ecologically valid measure of disability progression in MS.


Asunto(s)
Personas con Discapacidad , Esclerosis Múltiple , Dispositivos Electrónicos Vestibles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de la Discapacidad , Esclerosis Múltiple/diagnóstico , Prueba de Paso , Caminata/fisiología , Adulto
3.
Sensors (Basel) ; 23(16)2023 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-37631601

RESUMEN

In the last few years, interest in wearable technology for physiological signal monitoring is rapidly growing, especially during and after the COVID-19 pandemic [...].


Asunto(s)
COVID-19 , Dispositivos Electrónicos Vestibles , Humanos , COVID-19/diagnóstico , Pandemias , Fotopletismografía
4.
Sensors (Basel) ; 23(4)2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36850820

RESUMEN

Intervals of low-quality photoplethysmogram (PPG) signals might lead to significant inaccuracies in estimation of pulse arrival time (PAT) during polysomnography (PSG) studies. While PSG is considered to be a "gold standard" test for diagnosing obstructive sleep apnea (OSA), it also enables tracking apnea-related nocturnal blood pressure fluctuations correlated with PAT. Since the electrocardiogram (ECG) is recorded synchronously with the PPG during PSG, it makes sense to use the ECG signal for PPG signal-quality assessment. (1) Objective: to develop a PPG signal-quality assessment algorithm for robust PAT estimation, and investigate the influence of signal quality on PAT during various sleep stages and events such as OSA. (2) Approach: the proposed algorithm uses R and T waves from the ECG to determine approximate locations of PPG pulse onsets. The MESA database of 2055 PSG recordings was used for this study. (3) Results: the proportions of high-quality PPG were significantly lower in apnea-related oxygen desaturation (matched-pairs rc = 0.88 and rc = 0.97, compared to OSA and hypopnea, respectively, when p < 0.001) and arousal (rc = 0.93 and rc = 0.98, when p < 0.001) than in apnea events. The significantly large effect size of interquartile ranges of PAT distributions was between low- and high-quality PPG (p < 0.001, rc = 0.98), and regular and irregular pulse waves (p < 0.001, rc = 0.74), whereas a lower quality of the PPG signal was found to be associated with a higher interquartile range of PAT across all subjects. Suggested PPG signal quality-based PAT evaluation reduced deviations (e.g., rc = 0.97, rc = 0.97, rc = 0.99 in hypopnea, oxygen desaturation, and arousal stages, respectively, when p < 0.001) and allowed obtaining statistically larger differences between different sleep stages and events. (4) Significance: the implemented algorithm has the potential to increase the robustness of PAT estimation in PSG studies related to nocturnal blood pressure monitoring.


Asunto(s)
Fotopletismografía , Apnea Obstructiva del Sueño , Humanos , Polisomnografía , Frecuencia Cardíaca , Apnea Obstructiva del Sueño/diagnóstico , Oxígeno
5.
Sensors (Basel) ; 23(13)2023 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-37447866

RESUMEN

The aim of this study was to investigate the feasibility of automatically assessing the 2-Minute Walk Distance (2MWD) for monitoring people with multiple sclerosis (pwMS). For 154 pwMS, MS-related clinical outcomes as well as the 2MWDs as evaluated by clinicians and derived from accelerometer data were collected from a total of 323 periodic clinical visits. Accelerometer data from a wearable device during 100 home-based 2MWD assessments were also acquired. The error in estimating the 2MWD was validated for walk tests performed at hospital, and then the correlation (r) between clinical outcomes and home-based 2MWD assessments was evaluated. Robust performance in estimating the 2MWD from the wearable device was obtained, yielding an error of less than 10% in about two-thirds of clinical visits. Correlation analysis showed that there is a strong association between the actual and the estimated 2MWD obtained either at hospital (r = 0.71) or at home (r = 0.58). Furthermore, the estimated 2MWD exhibits moderate-to-strong correlation with various MS-related clinical outcomes, including disability and fatigue severity scores. Automatic assessment of the 2MWD in pwMS is feasible with the usage of a consumer-friendly wearable device in clinical and non-clinical settings. Wearable devices can also enhance the assessment of MS-related clinical outcomes.


Asunto(s)
Esclerosis Múltiple , Humanos , Caminata , Prueba de Paso , Fatiga
6.
Pattern Recognit ; 123: 108403, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34720200

RESUMEN

This study proposes a contrastive convolutional auto-encoder (contrastive CAE), a combined architecture of an auto-encoder and contrastive loss, to identify individuals with suspected COVID-19 infection using heart-rate data from participants with multiple sclerosis (MS) in the ongoing RADAR-CNS mHealth research project. Heart-rate data was remotely collected using a Fitbit wristband. COVID-19 infection was either confirmed through a positive swab test, or inferred through a self-reported set of recognised symptoms of the virus. The contrastive CAE outperforms a conventional convolutional neural network (CNN), a long short-term memory (LSTM) model, and a convolutional auto-encoder without contrastive loss (CAE). On a test set of 19 participants with MS with reported symptoms of COVID-19, each one paired with a participant with MS with no COVID-19 symptoms, the contrastive CAE achieves an unweighted average recall of 95.3 % , a sensitivity of 100 % and a specificity of 90.6 % , an area under the receiver operating characteristic curve (AUC-ROC) of 0.944, indicating a maximum successful detection of symptoms in the given heart rate measurement period, whilst at the same time keeping a low false alarm rate.

7.
Sensors (Basel) ; 22(15)2022 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-35957328

RESUMEN

Heart rate variability (HRV) has been studied for decades in clinical environments. Currently, the exponential growth of wearable devices in health monitoring is leading to new challenges that need to be solved. These devices have relatively poor signal quality and are affected by numerous motion artifacts, with data loss being the main stumbling block for their use in HRV analysis. In the present paper, it is shown how data loss affects HRV metrics in the time domain and frequency domain and Poincaré plots. A gap-filling method is proposed and compared to other existing approaches to alleviate these effects, both with simulated (16 subjects) and real (20 subjects) missing data. Two different data loss scenarios have been simulated: (i) scattered missing beats, related to a low signal to noise ratio; and (ii) bursts of missing beats, with the most common due to motion artifacts. In addition, a real database of photoplethysmography-derived pulse detection series provided by Apple Watch during a protocol including relax and stress stages is analyzed. The best correction method and maximum acceptable missing beats are given. Results suggest that correction without gap filling is the best option for the standard deviation of the normal-to-normal intervals (SDNN), root mean square of successive differences (RMSSD) and Poincaré plot metrics in datasets with bursts of missing beats predominance (p<0.05), whereas they benefit from gap-filling approaches in the case of scattered missing beats (p<0.05). Gap-filling approaches are also the best for frequency-domain metrics (p<0.05). The findings of this work are useful for the design of robust HRV applications depending on missing data tolerance and the desired HRV metrics.


Asunto(s)
Benchmarking , Dispositivos Electrónicos Vestibles , Artefactos , Electrocardiografía , Frecuencia Cardíaca/fisiología , Humanos , Fotopletismografía
8.
Philos Trans A Math Phys Eng Sci ; 379(2212): 20200261, 2021 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-34689618

RESUMEN

Stress test electrocardiogram (ECG) analysis is widely used for coronary artery disease (CAD) diagnosis despite its limited accuracy. Alterations in autonomic modulation of cardiac electrical activity have been reported in CAD patients during acute ischemia. We hypothesized that those alterations could be reflected in changes in ventricular repolarization dynamics during stress testing that could be measured through QT interval variability (QTV). However, QTV is largely dependent on RR interval variability (RRV), which might hinder intrinsic ventricular repolarization dynamics. In this study, we investigated whether different markers accounting for low-frequency (LF) oscillations of QTV unrelated to RRV during stress testing could be used to separate patients with and without CAD. Power spectral density of QTV unrelated to RRV was obtained based on time-frequency coherence estimation. Instantaneous LF power of QTV and QTV unrelated to RRV were obtained. LF power of QTV unrelated to RRV normalized by LF power of QTV was also studied. Stress test ECG of 100 patients were analysed. Patients referred to coronary angiography were classified into non-CAD or CAD group. LF oscillations in QTV did not show significant differences between CAD and non-CAD groups. However, LF oscillations in QTV unrelated to RRV were significantly higher in the CAD group as compared with the non-CAD group when measured during the first phases of exercise and last phases of recovery. ROC analysis of these indices revealed area under the curve values ranging from 61 to 73%. Binomial logistic regression analysis revealed LF power of QTV unrelated to RRV, both during the first phase of exercise and last phase of recovery, as independent predictors of CAD. In conclusion, this study highlights the importance of removing the influence of RRV when measuring QTV during stress testing for CAD identification and supports the added value of LF oscillations of QTV unrelated to RRV to diagnose CAD from the first minutes of exercise. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.


Asunto(s)
Enfermedad de la Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Electrocardiografía , Prueba de Esfuerzo , Frecuencia Cardíaca , Humanos
9.
Scand J Med Sci Sports ; 31(2): 339-349, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33038026

RESUMEN

Under the hypothesis that sympathetic control of ventricular repolarization may change once the second ventilatory threshold (VT2) has been reached, a novel methodology for non-invasive VT2 estimation based on the analysis of the T wave from the electrocardiogram (ECG) is proposed, and potential underlying physiological mechanisms are suggested. 25 volunteers (33.4 ± 5.2 years) underwent an incremental power cycle ergometer test (25 W/minute). During the test, respiratory gas exchange and multi-lead ECG were acquired. The former was employed to determine VT2, used here as a reference, whereas the latter was used to compute the temporal profiles of an index of ventricular repolarization instability (dT) and its low-frequency (LF) oscillations (LFdT). The sudden increases observed in dT and LFdT profiles above an established heart rate threshold were employed to derive VT2 estimates, referred to as VT2d T and VT2LF d T , respectively. Estimation errors of -4.7 ± 25.2 W were obtained when considering VT2d T . Errors were lower than the one-minute power increment of 25 W in 68% of the subjects and lower than 50 W in 89.5% of them. When using VT2LF d T , estimation error was of 15.3 ± 32.4 W. Most of the subjects shared common characteristic dT and LFdT profiles, which could be reflecting changes in the autonomic control of ventricular repolarization before and after reaching VT2. The analysis of ventricular repolarization dynamics during exercise allows non-invasive ECG-based estimation of VT2, possibly in relation to changes in the autonomic control of ventricular electrical activity when VT2 is reached.


Asunto(s)
Umbral Anaerobio/fisiología , Electrocardiografía/métodos , Prueba de Esfuerzo/métodos , Frecuencia Cardíaca/fisiología , Función Ventricular/fisiología , Adulto , Sistema Nervioso Autónomo/fisiología , Ejercicio Físico/fisiología , Humanos , Masculino , Intercambio Gaseoso Pulmonar/fisiología , Factores de Tiempo
10.
Sensors (Basel) ; 21(3)2021 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-33572800

RESUMEN

This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.


Asunto(s)
Electrocardiografía , Ejercicio Físico , Frecuencia Cardíaca , Adulto , Anciano , Composición Corporal , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
11.
Entropy (Basel) ; 23(10)2021 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-34681985

RESUMEN

Image processing has played a relevant role in various industries, where the main challenge is to extract specific features from images. Specifically, texture characterizes the phenomenon of the occurrence of a pattern along the spatial distribution, taking into account the intensities of the pixels for which it has been applied in classification and segmentation tasks. Therefore, several feature extraction methods have been proposed in recent decades, but few of them rely on entropy, which is a measure of uncertainty. Moreover, entropy algorithms have been little explored in bidimensional data. Nevertheless, there is a growing interest in developing algorithms to solve current limits, since Shannon Entropy does not consider spatial information, and SampEn2D generates unreliable values in small sizes. We introduce a proposed algorithm, EspEn (Espinosa Entropy), to measure the irregularity present in two-dimensional data, where the calculation requires setting the parameters as follows: m (length of square window), r (tolerance threshold), and ρ (percentage of similarity). Three experiments were performed; the first two were on simulated images contaminated with different noise levels. The last experiment was with grayscale images from the Normalized Brodatz Texture database (NBT). First, we compared the performance of EspEn against the entropy of Shannon and SampEn2D. Second, we evaluated the dependence of EspEn on variations of the values of the parameters m, r, and ρ. Third, we evaluated the EspEn algorithm on NBT images. The results revealed that EspEn could discriminate images with different size and degrees of noise. Finally, EspEn provides an alternative algorithm to quantify the irregularity in 2D data; the recommended parameters for better performance are m = 3, r = 20, and ρ = 0.7.

12.
Sensors (Basel) ; 18(8)2018 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-30103376

RESUMEN

Heart rate variability (HRV) analysis is a noninvasive tool widely used to assess autonomic nervous system state. The market for wearable devices that measure the heart rate has grown exponentially, as well as their potential use for healthcare and wellbeing applications. Still, there is a lack of validation of these devices. In particular, this work aims to validate the Apple Watch in terms of HRV derived from the RR interval series provided by the device, both in temporal (HRM (mean heart rate), SDNN, RMSSD and pNN50) and frequency (low and high frequency powers, LF and HF) domain. For this purpose, a database of 20 healthy volunteers subjected to relax and a mild cognitive stress was used. First, RR interval series provided by Apple Watch were validated using as reference the RR interval series provided by a Polar H7 using Bland-Altman plots and reliability and agreement coefficients. Then, HRV parameters derived from both RR interval series were compared and their ability to identify autonomic nervous system (ANS) response to mild cognitive stress was studied. Apple Watch measurements presented very good reliability and agreement (>0.9). RR interval series provided by Apple Watch contain gaps due to missing RR interval values (on average, 5 gaps per recording, lasting 6.5 s per gap). Temporal HRV indices were not significantly affected by the gaps. However, they produced a significant decrease in the LF and HF power. Despite these differences, HRV indices derived from the Apple Watch RR interval series were able to reflect changes induced by a mild mental stress, showing a significant decrease of HF power as well as RMSSD in stress with respect to relax, suggesting the potential use of HRV measurements derived from Apple Watch for stress monitoring.


Asunto(s)
Frecuencia Cardíaca/fisiología , Monitoreo Ambulatorio/normas , Estrés Psicológico/fisiopatología , Dispositivos Electrónicos Vestibles/normas , Sistema Nervioso Autónomo/fisiología , Voluntarios Sanos , Humanos , Reproducibilidad de los Resultados
13.
J Strength Cond Res ; 32(3): 716-725, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27749728

RESUMEN

Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).


Asunto(s)
Ejercicio Físico/fisiología , Frecuencia Cardíaca/fisiología , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/normas , Adulto , Electrocardiografía , Ergometría , Prueba de Esfuerzo , Humanos , Masculino , Consumo de Oxígeno/fisiología , Reproducibilidad de los Resultados , Frecuencia Respiratoria/fisiología , Descanso/fisiología
14.
J Electrocardiol ; 49(3): 401-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27036371

RESUMEN

Intrauterine Growth Restriction (IUGR) and premature birth are associated with higher risk of cardiovascular diseases throughout adulthood. The aim of this study was to evaluate the influence of these factors in ventricular electrical remodeling in preadolescents. Electrocardiography was performed in a cohort of 33-IUGR, 32-preterm with appropriate weight and 60 controls. Depolarization and repolarization processes were studied by means of the surface ECG, including loops and angles corresponding to QRS and T-waves. The angles between the dominant vector of QRS and the frontal plane XY were different among the study groups: controls [20.03°(10.11°-28.64°)], preterm [25.48°(19.79°-33.56°)], and IUGR [27.77°(16.59°-33.23°)]. When compared to controls, IUGR subjects also presented wider angles between the difference of QRS and T-wave dominant vectors and the XY-plane [5.28°±12.15° vs 0.49°±14.15°, p<0.05] while preterm ones showed smaller frontal QRS-T angle [4.68°(2.20°-12.89°) vs 6.57°(2.72°-11.31°), p<0.05]. Thus, electrical remodeling is present in IUGR and preterm preadolescents, and might predispose them to cardiovascular diseases in adulthood. Follow-up studies are warranted.


Asunto(s)
Retardo del Crecimiento Fetal/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Nacimiento Prematuro/fisiopatología , Vectorcardiografía/métodos , Remodelación Ventricular , Algoritmos , Niño , Diagnóstico por Computador/métodos , Femenino , Retardo del Crecimiento Fetal/patología , Sistema de Conducción Cardíaco/patología , Ventrículos Cardíacos/patología , Humanos , Masculino , Nacimiento Prematuro/diagnóstico , Nacimiento Prematuro/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
IEEE J Biomed Health Inform ; 28(6): 3457-3465, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38557616

RESUMEN

A novel method for tracking the tidal volume (TV) from electrocardiogram (ECG) is presented. The method is based on the amplitude of ECG-derived respiration (EDR) signals. Three different morphology-based EDR signals and three different amplitude estimation methods have been studied, leading to a total of 9 amplitude-EDR (AEDR) signals per ECG channel. The potential of these AEDR signals to track the changes in TV was analyzed. These methods do not need a calibration process. In addition, a personalized-calibration approach for TV estimation is proposed, based on a linear model that uses all AEDR signals from a device. All methods have been validated with two different ECG devices: a commercial Holter monitor, and a custom-made wearable armband. The lowest errors for the personalized-calibration methods, compared to a reference TV, were -3.48% [-17.41% / 12.93%] (median [first quartile / third quartile]) for the Holter monitor, and 0.28% [-10.90% / 17.15%] for the armband. On the other hand, medians of correlations to the reference TV were higher than 0.8 for uncalibrated methods, while they were higher than 0.9 for personal-calibrated methods. These results suggest that TV changes can be tracked from ECG using either a conventional (Holter) setup, or our custom-made wearable armband. These results also suggest that the methods are not as reliable in applications that induce small changes in TV, but they can be potentially useful for detecting large changes in TV, such as sleep apnea/hypopnea and/or exacerbations of a chronic respiratory disease.


Asunto(s)
Electrocardiografía Ambulatoria , Procesamiento de Señales Asistido por Computador , Volumen de Ventilación Pulmonar , Dispositivos Electrónicos Vestibles , Humanos , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Volumen de Ventilación Pulmonar/fisiología , Masculino , Adulto , Femenino , Electrocardiografía/métodos , Electrocardiografía/instrumentación , Persona de Mediana Edad , Adulto Joven
16.
IEEE Trans Biomed Eng ; 71(1): 326-333, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37523277

RESUMEN

OBJECTIVE: Hypoxic load is one of the main characteristics of obstructive sleep apnea (OSA) contributing to sympathetic overdrive and weakened cardiorespiratory coupling (CRC). Whether this association changes with increasing hypoxic load has remained obscure. Therefore, we aimed to study our hypothesis that increasing hypoxic load acutely decreases the CRC. METHODS: We retrospectively analyzed the electrocardiography and nasal pressure signals in 5-min segment pairs (n = 36 926) recorded during clinical polysomnographies of 603 patients with suspected OSA. The segment pairs were pooled into five groups based on the hypoxic load severity described with the the total integrated area under the blood oxygen saturation curve during desaturations. In these severity groups, we determined the frequency-domain heart rate variability (HRV) parameters, the HRV and respiratory high-frequency (HF, 0.15-0.4 Hz) peaks, and the difference between those peaks. We also computed the spectral HF coherence between HRV and respiration in the HF band. RESULTS: The ratio of low-frequency (LF, 0.04-0.15 Hz) to HF power increased from 1.047 to 1.805 (p < 0.001); the difference between the HRV and respiratory HF peaks increased from 0.001 Hz to 0.039 Hz (p < 0.001); and the spectral coherence between HRV and respiration in the HF band decreased from 0.813 to 0.689 (p < 0.001) as the hypoxic load increased. CONCLUSION AND SIGNIFICANCE: The vagal modulation decreases and CRC weakens significantly with increasing hypoxic load. Thus, the hypoxic load could be utilized more thoroughly in contemporary OSA diagnostics to better assess the severity of OSA-related cardiac stress.


Asunto(s)
Apnea Obstructiva del Sueño , Humanos , Estudios Retrospectivos , Apnea Obstructiva del Sueño/diagnóstico , Respiración , Corazón , Electrocardiografía , Hipoxia/diagnóstico , Frecuencia Cardíaca/fisiología
17.
Pediatr Pulmonol ; 59(1): 111-120, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37850730

RESUMEN

BACKGROUND: Obstructive sleep apnea (OSA) is a risk factor for metabolic syndrome (MetS) in adults, but its association in prepubertal children is still questionable due to the relatively limited cardiometabolic data available and the phenotypic heterogeneity. OBJECTIVE: To identify the role of OSA as a potential mediator of MetS in prepubertal children. METHODS: A total of 255 prepubertal children from the Childhood Adenotonsillectomy Trial were included, with standardized measurements taken before OSA treatment and 7 months later. MetS was defined if three or more of the following criteria were present: adiposity, high blood pressure, elevated glycemia, and dyslipidemia. A causal mediation analysis was conducted to assess the effect of OSA treatment on MetS. RESULTS: OSA treatment significantly impacted MetS, with the apnea-hypopnea index emerging as mediator (p = .02). This mediation role was not detected for any of the individual risk factors that define MetS. We further found that the relationship between MetS and OSA is ascribable to respiratory disturbance caused by the apnea episodes, while systemic inflammation as measured by C-reactive protein, is mediated by desaturation events and fragmented sleep. In terms of evolution, patients with MetS were significantly more likely to recover after OSA treatment (odds ratio = 2.56, 95% confidence interval [CI] 1.20-5.46; risk ratio = 2.06, 95% CI 1.19-3.54) than the opposite, patients without MetS to develop it. CONCLUSION: The findings point to a causal role of OSA in the development of metabolic dysfunction, suggesting that persistent OSA may increase the risk of MetS in prepubertal children. This mediation role implies a need for developing screening for MetS in children presenting OSA symptoms.


Asunto(s)
Síndrome Metabólico , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Adulto , Niño , Humanos , Síndrome Metabólico/complicaciones , Síndrome Metabólico/epidemiología , Síndromes de la Apnea del Sueño/diagnóstico , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/epidemiología , Apnea Obstructiva del Sueño/diagnóstico , Factores de Riesgo , Obesidad/complicaciones
18.
JMIR Res Protoc ; 13: e51298, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38551647

RESUMEN

BACKGROUND: Mental health conditions have become a substantial cause of disability worldwide, resulting in economic burden and strain on the public health system. Incorporating cognitive and physiological biomarkers using noninvasive sensors combined with self-reported questionnaires can provide a more accurate characterization of the individual's well-being. Biomarkers such as heart rate variability or those extracted from the electrodermal activity signal are commonly considered as indices of autonomic nervous system functioning, providing objective indicators of stress response. A model combining a set of these biomarkers can constitute a comprehensive tool to remotely assess mental well-being and distress. OBJECTIVE: This study aims to design and validate a remote multiparametric tool, including physiological and cognitive variables, to objectively assess mental well-being and distress. METHODS: This ongoing observational study pursues to enroll 60 young participants (aged 18-34 years) in 3 groups, including participants with high mental well-being, participants with mild to moderate psychological distress, and participants diagnosed with depression or anxiety disorder. The inclusion and exclusion criteria are being evaluated through a web-based questionnaire, and for those with a mental health condition, the criteria are identified by psychologists. The assessment consists of collecting mental health self-reported measures and physiological data during a baseline state, the Stroop Color and Word Test as a stress-inducing stage, and a final recovery period. Several variables related to heart rate variability, pulse arrival time, breathing, electrodermal activity, and peripheral temperature are collected using medical and wearable devices. A second assessment is carried out after 1 month. The assessment tool will be developed using self-reported questionnaires assessing well-being (short version of Warwick-Edinburgh Mental Well-being Scale), anxiety (Generalized Anxiety Disorder-7), and depression (Patient Health Questionnaire-9) as the reference. We will perform correlation and principal component analysis to reduce the number of variables, followed by the calculation of multiple regression models. Test-retest reliability, known-group validity, and predictive validity will be assessed. RESULTS: Participant recruitment is being carried out on a university campus and in mental health services. Recruitment commenced in October 2022 and is expected to be completed by June 2024. As of July 2023, we have recruited 41 participants. Most participants correspond to the group with mild to moderate psychological distress (n=20, 49%), followed by the high mental well-being group (n=13, 32%) and those diagnosed with a mental health condition (n=8, 20%). Data preprocessing is currently ongoing, and publication of the first results is expected by September 2024. CONCLUSIONS: This study will establish an initial framework for a comprehensive mental health assessment tool, taking measurements from sophisticated devices, with the goal of progressing toward a remotely accessible and objectively measured approach that maintains an acceptable level of accuracy in clinical practice and epidemiological studies. TRIAL REGISTRATION: OSF Registries N3GCH; https://doi.org/10.17605/OSF.IO/N3GCH. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/51298.

19.
IEEE J Biomed Health Inform ; 27(10): 4707-4718, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37478029

RESUMEN

Changes induced by intrauterine growth restriction (IUGR) in cardiovascular anatomy and function that persist throughout life have been associated with a higher predisposition to heart disease in adulthood. Together with cardiac morphological remodelling, evaluated through the ventricular sphericity index, alterations in cardiac electrical function have been reported by characterization of the depolarization and repolarization loops, and their angular relationship, measured from the vectorcardiogram. The underlying relationship between the morphological remodelling and the angular variation of QRS and T-wave dominant vectors, if any, has not been explored. The aim of this study was to evaluate this relationship using computational models based on realistic heart and torso in which IUGR-induced morphological changes were incorporated by reducing the ventricular sphericity index. Specifically, we departed from a control model and we built eight different globular heart models by reducing the base-to-apex length and enlarging the basal ventricular diameter. We computed QRS and T-wave dominant vectors and angles from simulated pseudo-electrocardiograms and we compared them with clinical measurements. Results for the QRS to T angles follow a change trend congruent with that reported in clinical data, supporting the hypothesis that the IUGR-induced morphological remodelling could contribute to explain the observed angle changes in IUGR patients. By additionally varying the position of the ventricles with respect to the torso and the electrodes, we found that electrode displacement can impact the quantified angles and should be considered when interpreting the results.

20.
Artículo en Inglés | MEDLINE | ID: mdl-37022916

RESUMEN

Due to frailty, cardiac rehabilitation in older patients after open-heart surgery must be carefully tailored, thus calling for informative and convenient tools to assess the effectiveness of exercise training programs. The study investigates whether heart rate (HR) response to daily physical stressors can provide useful information when parameters are estimated using a wearable device. The study included 100 patients after open-heart surgery with frailty who were assigned to intervention and control groups. Both groups attended inpatient cardiac rehabilitation however only the patients of the intervention group performed exercises at home according to the tailored exercise training program. While performing maximal veloergometry test and submaximal tests, i.e., walking, stair-climbing, and stand up and go, HR response parameters were derived from a wearable-based electrocardiogram. All submaximal tests showed moderate to high correlation ( r = 0.59-0.72) with veloergometry for HR recovery and HR reserve parameters. While the effect of inpatient rehabilitation was only reflected by HR response to veloergometry, parameter trends over the entire exercise training program were also well followed during stair-climbing and walking. Based on study findings, HR response to walking should be considered for assessing the effectiveness of home-based exercise training programs in patients with frailty.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA