Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Radiology ; 283(3): 723-728, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27918709

RESUMEN

Purpose To investigate the feasibility of using spectral photon-counting computed tomography (CT) to differentiate between gadolinium-based and nonionic iodine-based contrast material in a colon phantom by using the characteristic k edge of gadolinium. Materials and Methods A custom-made colon phantom was filled with nonionic iodine-based contrast material, and a gadolinium-filled capsule representing a contrast material-enhanced polyp was positioned on the colon wall. The colon phantom was scanned with a preclinical spectral photon-counting CT system to obtain spectral and conventional data. By fully using the multibin spectral information, material decomposition was performed to generate iodine and gadolinium maps. Quantitative measurements were performed within the lumen and polyp to quantitatively determine the absolute content of iodine and gadolinium. Results In a conventional CT section, absorption values of both contrast agents were similar at approximately 110 HU. Contrast material maps clearly differentiated the distributions, with gadolinium solely in the polyp and iodine in the lumen of the colon. Quantitative measurements of contrast material concentrations in the colon and polyp matched well with those of actual prepared mixtures. Conclusion Dual-contrast spectral photon-counting CT colonography with iodine-filled lumen and gadolinium-tagged polyps may enable ready differentiation between polyps and tagged fecal material. © RSNA, 2016.


Asunto(s)
Colonografía Tomográfica Computarizada , Colonografía Tomográfica Computarizada/métodos , Medios de Contraste , Gadolinio , Compuestos de Yodo , Fantasmas de Imagen , Fotones
2.
Opt Express ; 25(6): 6349-6364, 2017 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-28380987

RESUMEN

An X-ray grating interferometer (GI) suitable for clinical mammography must comply with quite strict dose, scanning time and geometry limitations, while being able to detect tumors, microcalcifications and other abnormalities. Such a design task is not straightforward, since obtaining optimal phase-contrast and dark-field signals with clinically compatible doses and geometrical constraints is remarkably challenging. In this work, we present a wave propagation based optimization that uses the phase and dark-field sensitivities as figures of merit. This method was used to calculate the optimal interferometer designs for a commercial mammography setup. Its accuracy was validated by measuring the visibility of polycarbonate samples of different thicknesses on a Talbot-Lau interferometer installed on this device and considering some of the most common grating imperfections to be able to reproduce the experimental values. The optimization method outcomes indicate that small grating pitches are required to boost sensitivity in such a constrained setup and that there is a different optimal scenario for each signal type.

3.
Nat Mater ; 14(7): 691-5, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26053760

RESUMEN

In situ X-ray diffraction (XRD) and transmission electron microscopy (TEM) have been used to investigate many physical science phenomena, ranging from phase transitions, chemical reactions and crystal growth to grain boundary dynamics. A major limitation of in situ XRD and TEM is a compromise that has to be made between spatial and temporal resolution. Here, we report the development of in situ X-ray nanodiffraction to measure high-resolution diffraction patterns from single grains with up to 5 ms temporal resolution. We observed, for the first time, grain rotation and lattice deformation in chemical reactions induced by X-ray photons: Br(-) + hv → Br + e(-) and e(-) + Ag(+) → Ag(0). The grain rotation and lattice deformation associated with the chemical reactions were quantified to be as fast as 3.25 rad s(-1) and as large as 0.5 Å, respectively. The ability to measure high-resolution diffraction patterns from individual grains with a temporal resolution of several milliseconds is expected to find broad applications in materials science, physics, chemistry and nanoscience.

4.
Nat Mater ; 14(11): 1099-103, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26390325

RESUMEN

Crystallography, the primary method for determining the 3D atomic positions in crystals, has been fundamental to the development of many fields of science. However, the atomic positions obtained from crystallography represent a global average of many unit cells in a crystal. Here, we report, for the first time, the determination of the 3D coordinates of thousands of individual atoms and a point defect in a material by electron tomography with a precision of ∼19 pm, where the crystallinity of the material is not assumed. From the coordinates of these individual atoms, we measure the atomic displacement field and the full strain tensor with a 3D resolution of ∼1 nm(3) and a precision of ∼10(-3), which are further verified by density functional theory calculations and molecular dynamics simulations. The ability to precisely localize the 3D coordinates of individual atoms in materials without assuming crystallinity is expected to find important applications in materials science, nanoscience, physics, chemistry and biology.


Asunto(s)
Tomografía con Microscopio Electrónico/métodos , Imagenología Tridimensional/métodos , Modelos Teóricos
5.
Opt Express ; 24(6): 6490-506, 2016 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-27136840

RESUMEN

Like many other advanced imaging methods, x-ray phase contrast imaging and tomography require mathematical inversion of the observed data to obtain real-space information. While an accurate forward model describing the generally nonlinear image formation from a given object to the observations is often available, explicit inversion formulas are typically not known. Moreover, the measured data might be insufficient for stable image reconstruction, in which case it has to be complemented by suitable a priori information. In this work, regularized Newton methods are presented as a general framework for the solution of such ill-posed nonlinear imaging problems. For a proof of principle, the approach is applied to x-ray phase contrast imaging in the near-field propagation regime. Simultaneous recovery of the phase- and amplitude from a single near-field diffraction pattern without homogeneity constraints is demonstrated for the first time. The presented methods further permit all-at-once phase contrast tomography, i.e. simultaneous phase retrieval and tomographic inversion. We demonstrate the potential of this approach by three-dimensional imaging of a colloidal crystal at 95nm isotropic resolution.

6.
J Synchrotron Radiat ; 22(4): 867-78, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26134789

RESUMEN

A compound optical system for coherent focusing and imaging at the nanoscale is reported, realised by high-gain fixed-curvature elliptical mirrors in combination with X-ray waveguide optics or different cleaning apertures. The key optical concepts are illustrated, as implemented at the Göttingen Instrument for Nano-Imaging with X-rays (GINIX), installed at the P10 coherence beamline of the PETRA III storage ring at DESY, Hamburg, and examples for typical applications in biological imaging are given. Characteristic beam configurations with the recently achieved values are also described, meeting the different requirements of the applications, such as spot size, coherence or bandwidth. The emphasis of this work is on the different beam shaping, filtering and characterization methods.

7.
J Synchrotron Radiat ; 20(Pt 3): 490-7, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23592629

RESUMEN

In the past decade Kirkpatrick-Baez (KB) mirrors have been established as powerful focusing systems in hard X-ray microscopy applications. Here a ptychographic characterization of the KB focus in the dedicated nano-imaging setup GINIX (Göttingen Instrument for Nano-Imaging with X-rays) at the P10 coherence beamline of the PETRA III synchrotron at HASLYLAB/DESY, Germany, is reported. More specifically, it is shown how aberrations in the KB beam, caused by imperfections in the height profile of the focusing mirrors, can be eliminated using a pinhole as a spatial filter near the focal plane. A combination of different pinhole sizes and illumination conditions of the KB setup makes the prepared optical setup well suited not only for high-resolution ptychographic coherent X-ray diffractive imaging but also for moderate-resolution/large-field-of-view propagation imaging in the divergent KB beam.


Asunto(s)
Lentes , Microscopía/instrumentación , Microscopía/métodos , Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/métodos , Simulación por Computador , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Modelos Teóricos
8.
J Psychiatr Res ; 41(7): 600-5, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16600301

RESUMEN

Fibromyalgia (FM) is still often viewed as a psychosomatic disorder. However, the increased pain sensitivity to stimuli in FM patients is not an "imagined" histrionic phenomena. Pain, which is consistently felt in the musculature, is related to specific abnormalities in the CNS pain matrix. Brain-derived neurotrophic factor (BDNF) is an endogenous protein involved in neuronal survival and synaptic plasticity of the central and peripheral nervous system (CNS and PNS). Several lines of evidence converged to indicate that BDNF also participates in structural and functional plasticity of nociceptive pathways in the CNS and within the dorsal root ganglia and spinal cord. In the latter, release of BDNF appears to modulate or even mediate nociceptive sensory inputs and pain hypersensitivity. We were interested, if BDNF serum concentration may be altered in FM. The present pilot study assessed to our knowledge for the first time BDNF serum concentrations in 41 FM patients in comparison to 45 age-matched healthy controls. Mean serum levels of BDNF in FM patients (19.6 ng/ml; SD 3.1) were significantly increased as compared to healthy controls (16.8 ng/ml; SD 2.7; p<0.0001). In addition, BDNF serum concentrations in FM patients were independent from age, gender, illness duration, preexisting recurrent major depression and antidepressive medication in low doses. In conclusion, the results from our study indicate that BDNF may be involved in the pathophysiology of pain in FM. Nevertheless, how BDNF increases susceptibility to pain is still not known.


Asunto(s)
Factor Neurotrófico Derivado del Encéfalo/sangre , Trastorno Depresivo Mayor/sangre , Fibromialgia/sangre , Amitriptilina/uso terapéutico , Antidepresivos/uso terapéutico , Encéfalo/efectos de los fármacos , Encéfalo/fisiopatología , Trastorno Depresivo Mayor/tratamiento farmacológico , Trastorno Depresivo Mayor/psicología , Relación Dosis-Respuesta a Droga , Doxepina/uso terapéutico , Femenino , Fibromialgia/tratamiento farmacológico , Fibromialgia/psicología , Fluoxetina/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Plasticidad Neuronal/efectos de los fármacos , Plasticidad Neuronal/fisiología , Nociceptores/efectos de los fármacos , Nociceptores/fisiopatología , Umbral del Dolor/efectos de los fármacos , Umbral del Dolor/fisiología , Valores de Referencia , Médula Espinal/efectos de los fármacos , Médula Espinal/fisiopatología
9.
Sci Rep ; 7(1): 4784, 2017 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-28684756

RESUMEN

A new prototype spectral photon-counting computed tomography (SPCCT) based on a modified clinical CT system has been developed. SPCCT analysis of the energy composition of the transmitted x-ray spectrum potentially allows simultaneous dual contrast agent imaging, however, this has not yet been demonstrated with such a system. We investigated the feasibility of using this system to distinguish gold nanoparticles (AuNP) and an iodinated contrast agent. The contrast agents and calcium phosphate were imaged in phantoms. Conventional CT, gold K-edge, iodine and water images were produced and demonstrated accurate discrimination and quantification of gold and iodine concentrations in a phantom containing mixtures of the contrast agents. In vivo experiments were performed using New Zealand White rabbits at several times points after injections of AuNP and iodinated contrast agents. We found that the contrast material maps clearly differentiated the distributions of gold and iodine in the tissues allowing quantification of the contrast agents' concentrations, which matched their expected pharmacokinetics. Furthermore, rapid, repetitive scanning was done, which allowed measurement of contrast agent kinetics with high temporal resolution. In conclusion, a clinical scale, high count rate SPCCT system is able to discriminate gold and iodine contrast media in different organs in vivo.


Asunto(s)
Medios de Contraste/farmacocinética , Tomografía Computarizada por Rayos X/métodos , Animales , Fosfatos de Calcio , Femenino , Oro/farmacocinética , Yopamidol/análogos & derivados , Yopamidol/farmacocinética , Masculino , Nanopartículas del Metal , Fantasmas de Imagen , Conejos
10.
Sci Rep ; 5: 9973, 2015 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-25966338

RESUMEN

We have performed x-ray phase-contrast tomography on mouse lung tissue. Using a divergent x-ray beam generated by nanoscale focusing, we used zoom tomography to produce three-dimensional reconstructions with selectable magnification, resolution, and field of view. Thus, macroscopic tissue samples extending over several mm can be studied in sub-cellular-level structural detail. The zoom capability and, in particular, the high dose efficiency are enabled by the near-perfect exit wavefront of an optimized x-ray waveguide channel. In combination with suitable phase-retrieval algorithms, challenging radiation-sensitive and low-contrast samples can be reconstructed with minimal artefacts. The dose efficiency of the method is demonstrated by the reconstruction of living macrophages both with and without phagocytized contrast agents. We also used zoom tomography to visualize barium-labelled macrophages in the context of morphological structures in asthmatic and healthy mouse lung tissue one day after intratracheal application. The three-dimensional reconstructions showed that the macrophages predominantly localized to the alveoli, but they were also found in bronchial walls, indicating that these cells might be able to migrate from the lumen of the bronchi through the epithelium.


Asunto(s)
Movimiento Celular/fisiología , Macrófagos Alveolares , Alveolos Pulmonares , Mucosa Respiratoria , Tomografía por Rayos X/métodos , Animales , Línea Celular Transformada , Macrófagos Alveolares/diagnóstico por imagen , Macrófagos Alveolares/fisiología , Ratones , Alveolos Pulmonares/diagnóstico por imagen , Alveolos Pulmonares/fisiología , Mucosa Respiratoria/diagnóstico por imagen , Mucosa Respiratoria/fisiología
11.
J Clin Invest ; 124(3): 1114-29, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24509078

RESUMEN

Auditory prostheses can partially restore speech comprehension when hearing fails. Sound coding with current prostheses is based on electrical stimulation of auditory neurons and has limited frequency resolution due to broad current spread within the cochlea. In contrast, optical stimulation can be spatially confined, which may improve frequency resolution. Here, we used animal models to characterize optogenetic stimulation, which is the optical stimulation of neurons genetically engineered to express the light-gated ion channel channelrhodopsin-2 (ChR2). Optogenetic stimulation of spiral ganglion neurons (SGNs) activated the auditory pathway, as demonstrated by recordings of single neuron and neuronal population responses. Furthermore, optogenetic stimulation of SGNs restored auditory activity in deaf mice. Approximation of the spatial spread of cochlear excitation by recording local field potentials (LFPs) in the inferior colliculus in response to suprathreshold optical, acoustic, and electrical stimuli indicated that optogenetic stimulation achieves better frequency resolution than monopolar electrical stimulation. Virus-mediated expression of a ChR2 variant with greater light sensitivity in SGNs reduced the amount of light required for responses and allowed neuronal spiking following stimulation up to 60 Hz. Our study demonstrates a strategy for optogenetic stimulation of the auditory pathway in rodents and lays the groundwork for future applications of cochlear optogenetics in auditory research and prosthetics.


Asunto(s)
Estimulación Acústica , Sordera/cirugía , Optogenética , Animales , Channelrhodopsins , Cóclea/fisiopatología , Cóclea/cirugía , Implantación Coclear , Estimulación Eléctrica , Potenciales Evocados Auditivos , Luz , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Estimulación Luminosa , Ratas , Ratas Transgénicas , Ratas Wistar , Ganglio Espiral de la Cóclea/patología , Ganglio Espiral de la Cóclea/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA