1.
Eur J Nucl Med Mol Imaging ; 51(8): 2320-2331, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38453729

RESUMEN

PURPOSE: The recent development and approval of new diagnostic imaging and therapy approaches in the field of theranostics have revolutionised nuclear medicine practice. To ensure the provision of these new imaging and therapy approaches in a safe and high-quality manner, training of nuclear medicine physicians and qualified specialists is paramount. This is required for trainees who are learning theranostics practice, and for ensuring minimum standards for knowledge and competency in existing practising specialists. METHODS: To address the need for a training curriculum in theranostics that would be utilised at a global level, a Consultancy Meeting was held at the IAEA in May 2023, with participation by experts in radiopharmaceutical therapy and theranostics including representatives of major international organisations relevant to theranostics practice. RESULTS: Through extensive discussions and review of existing curriculum and guidelines, a harmonised training program for theranostics was developed, which aims to ensure safe and high quality theranostics practice in all countries. CONCLUSION: The guiding principles for theranostics training outlined in this paper have immediate relevance for the safe and effective practice of theranostics.


Asunto(s)
Medicina Nuclear , Humanos , Medicina Nuclear/educación , Nanomedicina Teranóstica , Curriculum
2.
Q J Nucl Med Mol Imaging ; 67(1): 75-82, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33686849

RESUMEN

BACKGROUND: Omission errors in medical imaging can lead to missed diagnosis and harm to patients. The subject has been studied in conventional imaging, but no data is available for functional imaging in general and for PET/CT in particular. In this work, we evaluated the frequency and characteristics of perceptual omission errors in the PET component of oncologic PET/CT imaging, and we analyzed the hazardous scenarios prone to such modality-specific errors. METHODS: Perceptual omission errors were collected in one tertiary center PET/CT clinic during routine PET/CT reporting over a 26-month period. The omissions were detected either in reporting follow-up PET/CT studies of the same patient or during multidisciplinary meetings. RESULTS: Significant omission errors were found in 1.2% of the 2100 reports included in the study. The most common omissions were bone metastases and focal colon uptake. We identified six PET-specific causative factors contributing to the occurrence of omissions, and we propose solutions to minimize their influence. CONCLUSIONS: The data presented here can help to promote the awareness of interpreting physicians to body areas that require higher attention and to implement reading strategies for improving the accuracy of PET/CT interpretation.


Asunto(s)
Neoplasias Óseas , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Neoplasias Óseas/secundario , Fluorodesoxiglucosa F18
3.
Harefuah ; 160(7): 419-424, 2021 07.
Artículo en Hebreo | MEDLINE | ID: mdl-34263567

RESUMEN

AIMS: The aim of this study was to evaluate the predictive power of the absorbed dose to kidneys after the first course of treatment with [177Lu]-DOTA-TATE on the cumulative kidney absorbed dose after 3 or 4 cycles of treatment. BACKGROUND: Peptide receptor radionuclide therapy (PRRT) with [177Lu]-DOTA-TATE is an effective treatment for somatostatin receptor positive neuroendocrine tumors (NETs). Post-treatment scans (PTS) are required after each cycle of treatment for personalized radiation dosimetry in order to calculate the dose to organs and tumors and to ensure a cumulative absorbed dose to kidneys under a safety threshold of 25 Gy. METHODS: A total of 187 patients who completed treatment and underwent PTS for dosimetry calculation were included in this retrospective study. The correlation between the cumulative absorbed dose to the kidneys after completion of treatment and the absorbed dose after the first cycle(s) was studied. Multilinear regression analysis was performed to predict the cumulative absorbed dose by the kidneys in the subsequent cycles. An algorithm for the follow-up of the kidney absorbed dose is proposed. RESULTS: When the absorbed dose to kidneys after the first cycle of treatment is below 5.6 Gy, four cycles of treatment can be safely administered with a cumulative dose less than 25 Gy (p < 0.1). For the remaining patients, the cumulative dose absorbed after 3 or 4 cycles of treatment can be predicted after the second cycle of treatment. This protocol enabled early decisions on the number of treatment cycles and reduced the number of post-treatment SPECT/CT studies for dosimetry in 34% of patients, as well as hospitalization time for 56% of the treatment cycles. CONCLUSIONS: Assessment of the kidney absorbed dose after PRRT can be simplified with the algorithm presented in this study. This approach enabled early decisions on the number of therapy cycles in 75% of patients. DISCUSSION: The validity of these results is limited to the protocol of dosimetry calculation used in our institution. Implementation in other centers may require standardization of the acquisition parameters and the dosimetry protocol.


Asunto(s)
Tumores Neuroendocrinos , Exposición a la Radiación , Humanos , Tumores Neuroendocrinos/radioterapia , Radioisótopos , Radiometría , Estudios Retrospectivos
4.
Oncologist ; 25(9): 787-792, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32430954

RESUMEN

BACKGROUND: Prostate cancer is a common malignancy of the elderly, and with the aging of the population, the need is growing for therapies suitable for this age group. Lutetium-177-prostate-specific membrane antigen (Lu-PSMA), a radiolabeled small molecule, binds with high affinity to prostate-specific membrane antigen, enabling beta particle therapy targeted to metastatic castration-resistant prostate cancer (mCRPC). In a recent single-arm phase II trial and a subsequent expansion cohort, a prostate-specific antigen (PSA) decline of ≥50% was observed in approximately 60% of patients receiving Lu-PSMA. Taking into account the specific challenges and potential toxicities of Lu-PSMA administration in elderly men, we sought to retrospectively analyze the safety and activity of Lu-PSMA in men aged older than 75 years with mCRPC. PATIENTS AND METHODS: The electronic medical records of 24 patients aged older than 75 years treated with Lu-PSMA "off-trial" were reviewed, and clinical data were extracted. Clinical endpoints were toxicity and activity, defined as a PSA decline ≥50%. Descriptive statistics were performed using Excel. RESULTS: The median age at treatment start was 81.7 years (range 75.1-91.9). The median number of previous treatment lines was four. The number of treatment cycles ranged from one to four; the mean administered radioactivity was 6 GBq per cycle. Treatment was generally tolerable; side effects included fatigue (n = 8, 33%), anemia (n = 7, 29%), thrombocytopenia (n = 5, 21%), and anorexia/nausea (n = 3, 13%). Clinical benefit was observed in 12 of 22 patients (54%); PSA decline above 50% was observed in 11 patients (48%) and was associated with significantly longer overall survival. CONCLUSION: Our results indicate that Lu-PSMA is safe and active in elderly patients with mCRPC. IMPLICATIONS FOR PRACTICE: Lutetium-177-prostate-specific membrane antigen (Lu-PSMA), a radiolabeled small molecule, binds with high affinity to prostate-specific membrane antigen, enabling beta particle therapy targeted to metastatic castration-resistant prostate cancer (mCRPC). The recently published single-arm phase II trial with Lu-PSMA, describing its safety and activity, did not include patients aged older than 75 years. In this study, Lu-PSMA activity was retrospectively analyzed in patients aged older than 75 years and results indicate that treatment was tolerable and similarly active in this age group, with no new emerging safety signals. Despite the small cohort size, this analysis suggests that Lu-PSMA can serve as an advanced palliative treatment line in mCRPC in elderly patients.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Anciano , Anciano de 80 o más Años , Dipéptidos , Compuestos Heterocíclicos con 1 Anillo , Humanos , Lutecio , Masculino , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Radioisótopos/uso terapéutico , Radiofármacos , Estudios Retrospectivos , Resultado del Tratamiento
5.
Endocr Pract ; 26(10): 1131-1142, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33471715

RESUMEN

OBJECTIVE: Von Hippel-Lindau (VHL) syndrome is a rare and complex disease. In 1996, we described a 3 generation VHL 2A kindred with 11 mutation carriers. We aim to share our experience regarding the long-term follow-up of this family and the management of all our other VHL patients focusing on frequently encountered neuroendocrine neoplasms: pheochromocytoma/paraganglioma and pancreatic neuroendocrine neoplasms (PNEN). METHODS: All VHL patients in follow-up at our tertiary center from 1980 to 2019 were identified. Clinical, laboratory, imaging, and therapeutic characteristics were retrospectively analyzed. RESULTS: We identified 32 VHL patients in 16 different families, 7/16 were classified as VHL 2 subtype. In the previously described family, the 4 initially asymptomatic carriers developed a neuroendocrine tumor; 7 new children were born, 3 of them being mutation carriers; 2 patients died, 1 due to metastatic PNEN-related liver failure. Pheochromocytoma was frequent (22/32), bilateral (13/22;59%), often diagnosed in early childhood when active screening was timely performed, associated with paraganglioma in 5/22, rarely malignant (1/22), and recurred after surgery in some cases after more than 20 years. PNEN occurred in 8/32 patients (25%), and was metastatic in 3 patients. Surgery and palliative therapy allowed relatively satisfactory outcomes. Severe disabling morbidities due to central-nervous system and ophthalmologic hemangiomas, and other rare tumors as chondrosarcoma in 2 patients and polycythemia in 1 patient were observed. CONCLUSION: A multidisciplinary approach and long-term follow-up is mandatory in VHL patients to manage the multiple debilitating morbidities and delay mortality in these complex patients.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Tumores Neuroendocrinos , Neoplasias Pancreáticas , Enfermedad de von Hippel-Lindau , Neoplasias de las Glándulas Suprarrenales/epidemiología , Neoplasias de las Glándulas Suprarrenales/terapia , Niño , Preescolar , Humanos , Recurrencia Local de Neoplasia , Tumores Neuroendocrinos/epidemiología , Tumores Neuroendocrinos/terapia , Neoplasias Pancreáticas/epidemiología , Neoplasias Pancreáticas/terapia , Estudios Retrospectivos , Proteína Supresora de Tumores del Síndrome de Von Hippel-Lindau , Enfermedad de von Hippel-Lindau/epidemiología , Enfermedad de von Hippel-Lindau/genética
6.
Eur Radiol ; 28(6): 2264-2272, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29264635

RESUMEN

OBJECTIVE: We describe FDG-PET/CT findings of postoperative fat necrosis in patients following abdominal surgery, and evaluate their changes in size and FDG uptake over time. METHODS: FDG-PET/CT scans from January 2007-January 2016 containing the term 'fat necrosis' were reviewed. Lesions meeting radiological criteria of fat necrosis in patients with prior abdominal surgery were included. RESULTS: Forty-four patients, 30 males, mean age 68.4 ± 11.0 years. Surgeries: laparotomy (n=37; 84.1 %), laparoscopy (n=3; 6.8 %), unknown (n=4; 9.1 %). CTs of all lesions included hyperdense well-defined rims surrounding a heterogeneous fatty core. Sites: peritoneum (n=34; 77 %), omental fat (n=19; 43 %), subcutaneous fat (n=8; 18 %), retroperitoneum (n=2; 5 %). Mean lesion long axis: 33.6±24.9 mm (range: 13.0-140.0). Mean SUVmax: 2.6±1.1 (range: 0.6-5.1). On serial CTs (n=34), lesions decreased in size (p=0.022). Serial FDG-PET/CT (n=24) showed no significant change in FDG-avidity (p=0.110). Mean SUVmax did not correlate with time from surgery (p=0.558) or lesion size (p=0.259). CONCLUSION: Postsurgical fat necrosis demonstrated characteristic CT features and may demonstrate increased FDG uptake. However, follow-up of subsequent imaging scans showed no increases in size or FDG-avidity. Awareness of this entity is important to avoid misinterpretation of findings as recurrent cancer. KEY POINTS: • Postsurgical fat necrosis may mimic cancer in FDG-PET/CT. • Follow-up of fat necrosis showed no increase in FDG intensity. • CT follow-up showed a decrease in lesion size. • FDG uptake did not correlate with time lapsed from surgery.


Asunto(s)
Abdomen/cirugía , Necrosis Grasa/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Neoplasias Abdominales/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Necrosis Grasa/etiología , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Estudios Retrospectivos
9.
Eur J Nucl Med Mol Imaging ; 43(13): 2423-2432, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27542010

RESUMEN

The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.


Asunto(s)
Técnicas de Imagen Cardíaca/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Cintigrafía/métodos , Compuestos de Cadmio/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Europa (Continente) , Medicina Basada en la Evidencia , Rayos gamma , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio/efectos de la radiación , Zinc/efectos de la radiación
10.
J Nucl Cardiol ; 23(2): 301-10, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26403143

RESUMEN

Myocardial perfusion imaging is a well-established and widely used imaging technique for the assessment of patients with known or suspected coronary artery disease. Pitfalls and artifacts associated with conventional gamma cameras are well known, and the ways to avoid and correct them have been described. In recent years solid-state detector dedicated cardiac cameras were introduced and have been shown to offer improved accuracy in addition to new imaging protocols and novel applications. The purpose of this manuscript is to familiarize the readers with the causes and effects of technical, patient-related, and operator-related pitfalls and artifacts associated with the D-SPECT dedicated cardiac camera with solid-state detectors. The manuscript offers guidance on how to avoid these factors, how to detect them, and how to correct better for them, providing high-quality diagnostic images.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Corazón/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador
11.
J Nucl Cardiol ; 21(3): 478-85, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24477404

RESUMEN

PURPOSE: We have assessed whether additional upright imaging increases the confidence of interpretation of stress only supine myocardial perfusion imaging (MPI) in obese patients. METHODS AND RESULTS: Tc-MIBI stress MPI of 101 consecutive patients (M = 49, 62 ± 12 years) with BMI ≥30 scanned on the D-SPECT cardiac camera were assessed. Images were interpreted as diagnostic or equivocal and the need for a rest study was recorded. Stress supine MPI was interpreted first, then gated and finally upright data were added. Defects on supine but not on upright were defined as artefacts and defects seen on both as abnormal. The total perfusion deficit (TPD) was also quantified. There were 27 normal, 22 abnormal, and 52 equivocal supine scans. The median EF was 52%, unaffecting the need for rest imaging. Upright imaging reclassified 32/52 (62%) equivocal studies as normal and 6/52 (11%) as abnormal (P < 0.001). Rest scan was deemed needed in 74/101 patients on supine vs 42/101 on supine/upright (P < 0.001). Supine TPD was normal in 53 and supine/upright TPD was normal in 70 patients (P < 0.001). CONCLUSION: Supine stress MPI is inadequate in obese patients. The addition of upright imaging significantly increases the ability to interpret scans as diagnostic and may reduce considerably the need for rest imaging.


Asunto(s)
Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Imagen de Perfusión Miocárdica/instrumentación , Obesidad/diagnóstico por imagen , Posicionamiento del Paciente/métodos , Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Dobutamina , Diseño de Equipo , Análisis de Falla de Equipo , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad/complicaciones , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Posición Supina , Vasodilatadores
12.
PET Clin ; 19(3): 389-399, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38679550

RESUMEN

Prostate cancer is the most common malignancy in men worldwide, with an estimated 174,650 new cases per year in the United States, and the second cancer-related cause of death, after lung cancer, with 31,620 deaths per year. While the 5 year survival rate for prostate cancer in patients without metastatic spread is nearly 100%, those with distant metastases have 5 year survival rates of approximately 30%. Initial diagnosis and assessment are based on PSA levels, Gleason score (derived from prostate biopsy), and advanced imaging modalities, including prostate MR imaging and PSMA-PET/computed tomography in patients with high-risk features.


Asunto(s)
Neoplasias de la Próstata , Radiofármacos , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Radiofármacos/uso terapéutico , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Partículas beta/uso terapéutico
13.
J Neurol Sci ; 459: 122983, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38574438

RESUMEN

Acute midbrain injury may cause both hyperkinetic movement disorders and parkinsonism. The temporal interval between the insult and the emergence of hyperkinetic disorders can last years. A delayed appearance of parkinsonism, on the other hand, was rarely described. We present three cases of male patients (50-, 58- and 28-year-old) who developed levodopa-responsive parkinsonism 20, 8 and two years, respectively, after acute brain insult involving the midbrain. Insults included subcortical intracerebral hemorrhage dissecting into the midbrain, embolic basilar occlusion and trauma. A fluorodopa scan, performed in two cases, revealed reduced striatal uptake. All individuals improved on low doses of levodopa and developed motor fluctuations shortly after levodopa was introduced. We conclude that delayed, levodopa-responsive parkinsonism following midbrain injury should be recognized in the relevant clinical setup. Possible mechanisms include age-related loss of dopaminergic neurons superimposed on acute injury and secondary neurodegeneration.


Asunto(s)
Levodopa , Trastornos Parkinsonianos , Humanos , Masculino , Levodopa/efectos adversos , Trastornos Parkinsonianos/complicaciones , Trastornos Parkinsonianos/diagnóstico por imagen , Trastornos Parkinsonianos/tratamiento farmacológico , Encéfalo , Mesencéfalo/diagnóstico por imagen , Cuerpo Estriado
14.
EJNMMI Res ; 14(1): 52, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38809472

RESUMEN

BACKGROUND: F-18-flurodeoxyglucose (FDG) PET/CT is routinely used for staging, evaluation of response to treatment and follow-up of most pediatric malignancies. Cervical lymph nodes can be involved in some pediatric malignancies, but increased uptake in non-malignant cervical lymph nodes is not exceptional in this population. The aim of the present study is to identify predictors of the maximum uptake in non-malignant cervical lymph nodes in the pediatric population. METHODS: 191 FDG PET/CT studies of pediatric patients without malignant involvement of cervical lymph nodes were retrospectively reviewed. The maximal Standard Uptake Value in the hottest cervical lymph node (SUVmaxCLN), as well as demographic, technical and imaging variables were recorded. The predictive effect of those variables on SUVmaxCLN was estimated using linear regression models. RESULTS: Increased FDG activity in cervical nodes was observed in 136/191 studies (71%). The mean SUVmaxCLN was 2.2 ± 1.3. Ipsilateral palatine tonsil SUVmax, mean liver uptake, and treatment status were all statistically significant predictors of SUVmaxCLN. However, in multivariate regression analysis, only ipsilateral palatine tonsil SUVmax was found to be significant. In addition, SUVmaxCLN was greater than the mean liver uptake in 50% of all studies. This proportion was higher in younger children, reaching 77% of studies of children younger than six years. CONCLUSION: SUVmax in ipsilateral palatine tonsil is a strong predictor of the maximal uptake value of non-malignant cervical lymph nodes in children. The intensity of uptake in non-malignant cervical lymph nodes is frequently higher than liver uptake in children, and this tendency increases for younger patients. TRIAL WAS REGISTERED: In the internal hospital registry under TRN 0209-22-HMO on date 23.04.2022.

15.
Eur J Nucl Med Mol Imaging ; 40(7): 1084-94, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23595108

RESUMEN

PURPOSE: High-speed (HS) single-photon emission computed tomography (SPECT) with a recently developed solid-state camera shows comparable myocardial perfusion abnormalities to those seen in conventional SPECT. We aimed to compare HS and conventional SPECT images from multiple centres with coronary angiographic findings. METHODS: The study included 50 patients who had sequential conventional SPECT and HS SPECT myocardial perfusion studies and coronary angiography within 3 months. Stress and rest perfusion images were visually analysed and scored semiquantitatively using a 17-segment model by two experienced blinded readers. Global and coronary territorial summed stress scores (SSS) and summed rest scores (SRS) were calculated. Global SSS ≥3 or coronary territorial SSS ≥2 was considered abnormal. In addition the total perfusion deficit (TPD) was automatically derived. TPD >5% and coronary territorial TPD ≥3% were defined as abnormal. Coronary angiograms were analysed for site and severity of coronary stenosis; ≥50% was considered significant. RESULTS: Of the 50 patients, 13 (26%) had no stenosis, 22 (44%) had single-vessel disease, 6 (12%) had double-vessel disease and 9 (18%) had triple-vessel disease. There was a good linear correlation between the visual global SSS and SRS (Spearman's ρ 0.897 and 0.866, respectively; p < 0.001). In relation to coronary angiography, the sensitivities, specificities and accuracies of HS SPECT and conventional SPECT by visual assessment were 92% (35/38), 83% (10/12) and 90% (45/50) vs. 84% (32/38), 50% (6/12) and 76% (38/50), respectively (p < 0.001). The sensitivities, specificities and accuracies of HS SPECT and conventional SPECT in relation to automated TPD assessment were 89% (31/35), 57% (8/14) and 80% (39/49) vs. 86% (31/36), 77% (10/13) and 84% (41/49), respectively. CONCLUSION: HS SPECT allows fast acquisition of myocardial perfusion images that correlate well with angiographic findings with overall accuracy by visual assessment better than conventional SPECT. Further assessment in a larger patient population may be needed to confirm this observation.


Asunto(s)
Angiografía Coronaria , Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
16.
Pediatr Radiol ; 43(8): 941-9, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23377561

RESUMEN

BACKGROUND: Accurate assessment of splenic disease is important for staging Hodgkin lymphoma. OBJECTIVE: The purpose of this study was to assess T2-weighted imaging with and without dynamic contrast-enhanced (DCE) MRI for evaluation of splenic Hodgkin disease. MATERIALS AND METHODS: Thirty-one children with Hodgkin lymphoma underwent whole-body T2-weighted MRI with supplementary DCE splenic imaging, and whole-body PET-CT before and following chemotherapy. Two experienced nuclear medicine physicians derived a PET-CT reference standard for splenic disease, augmented by follow-up imaging. Unaware of the PET-CT, two experienced radiologists independently evaluated MRI exercising a locked sequential read paradigm (T2-weighted then DCE review) and recorded the presence/absence of splenic disease at each stage. Performance of each radiologist was determined prior to and following review of DCE-MRI. Incorrect MRI findings were ascribed to reader (lesion present on MRI but missed by reader) or technical (lesion not present on MRI) error. RESULTS: Seven children had splenic disease. Sensitivity/specificity of both radiologists for the detection of splenic involvement using T2-weighted images alone was 57%/100% and increased to 100%/100% with DCE-MRI. There were three instances of technical error on T2-weighted imaging; all lesions were visible on DCE-MRI. CONCLUSIONS: T2-weighted imaging when complemented by DCE-MRI imaging may improve evaluation of Hodgkin disease splenic involvement.


Asunto(s)
Algoritmos , Enfermedad de Hodgkin/patología , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Meglumina , Compuestos Organometálicos , Neoplasias del Bazo/patología , Adolescente , Niño , Medios de Contraste , Femenino , Humanos , Masculino , Estadificación de Neoplasias , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
EJNMMI Phys ; 10(1): 5, 2023 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-36689080

RESUMEN

BACKGROUND: Conventional calibration of the gamma camera consists of the calculation of calibration factors (CFs) (ratio of counts/cc and true concentration activity) as the function of the volume of interest (VOI). However, such method shows inconsistent results when the background activity varies. The aim of the present study was to propose a new calibration method by considering the sphere-to-background counts/voxel ratio (SBVR) in addition to the VOI for CFs calculation. A PET cylindrical flood phantom, a NEMA IQ body phantom, a Data spectrum Torso Phantom (ECT/TOR/P) and a LK-S Kyoto Liver/Kidney phantom were used. The NEMA IQ phantom was used to calibrate the camera and to produce CFs for the different spheres volumes and for varying sphere-to-background activity ratios. The spheres were filled with a uniform activity concentration of 177Lu, while the background was first filled with cold water and activity was added between each SPECT scan. SPECT imaging was performed for 30-s, 20-s, and 10-s exposure per view. The calculated CFs were expressed as function of the sphere volume and SBVR. The obtained CFs were validated for an additional NEMA IQ acquisition with different activities in spheres and background and for the Torso and Liver/Kidney phantoms with inserted NEMA IQ spheres. The quantification accuracy was compared with the conventional method not taking SBVR into consideration. RESULTS: The relative errors in quantification using the NEMA IQ phantom with the new calibration method were 0.16%, 5.77%, 9.34% for the large, medium and small sphere, respectively, for a time per view of 30-s. The conventional calibration method gave errors of 3.65%, 6.65%, 30.28% for 30-s. The LK-S Kyoto Liver/Kidney Phantom resulted in quantification errors of 3.40%, 2.14%, 11.18% for the large, medium and small spheres, respectively, for 30-s; compared to 11.31%, 17.54%, 14.43% for 30-s, respectively, for the conventional method. Similar results were obtained for shorter acquisitions times with 20-s and 10-s time per view. CONCLUSION: These results suggest that SBVR allows to improve quantification accuracy. The shorter time-per-view acquisitions had similar relative differences compared to the full-time acquisition which allows shorter imaging times with 177Lu and improved patient comfort. The SBVR method is simple to set up and can be proposed for standardization.

18.
J Nucl Med ; 64(10): 1610-1616, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37500259

RESUMEN

Dosimetry after 177Lu-DOTATATE peptide receptor radionuclide therapy (PRRT) enables estimation of radiation doses absorbed by normal organs and target lesions. This process is time-consuming and requires multiple posttreatment studies on several subsequent days. In a previous study, we described a newly developed multiple-linear-regression model to predict absorbed doses (ADs) from a single-time-point (STP) posttreatment study acquired 168 h after the first infusion and 24 h after the following ones, with similar results to the standard multiple-time-point (MTP) protocol. The present study aimed to validate this model in a large patient cohort and to assess whether STP dosimetry affects patient management decisions compared with our MTP protocol. Methods: Quantitative 177Lu-DOTATATE SPECT/CT post-PRRT data from 159 consecutive patients (172 therapies, 477 therapy cycles) were retrospectively analyzed. ADs obtained from an STP model were compared with those obtained using an MTP model. We evaluated the impact of the STP model on the decision on whether PRRT should be stopped because of an expected kidney AD exceeding the safety threshold. We hypothesized that patient management based on the STP model does not differ from that based on the MTP model in at least 90% of the cases. Results: There was no difference in management decisions between the MTP and STP models in 170 of 172 therapies (98.8%). A Fisher χ2 test for combined probabilities produced a composite P value of 0.0003. Mean cumulative AD relative differences between the STP and MTP models were 0.8% ± 8.0%, -7.7% ± 4.8%, 0.0% ± 11.4%, -2.8% ± 6.3%, and -2.1% ± 18.4% for kidneys, bone marrow, liver, spleen, and tumors, respectively (Pearson r = 0.99 for all), for patients who underwent 4 therapy cycles. Similar results were obtained with fewer therapy cycles. Conclusion: Estimated radiation ADs and patient management decisions were similar with the STP and MTP models. The STP model can simplify the dosimetry process while also reducing scanner and staff time and improving patient comfort.


Asunto(s)
Tumores Neuroendocrinos , Compuestos Organometálicos , Humanos , Estudios Retrospectivos , Octreótido/efectos adversos , Radiometría , Riñón , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Tumores Neuroendocrinos/radioterapia , Tumores Neuroendocrinos/tratamiento farmacológico , Compuestos Organometálicos/uso terapéutico
19.
Oncologist ; 17(5): 613-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22539550

RESUMEN

INTRODUCTION: Currently, there is a lack of data on the role of combined positron emission tomography-computed tomography (PET-CT) in the staging of early invasive primary breast cancer. We therefore evaluated the role of (18)F-fluorodeoxyglucose ((18)F-FDG)-PET-CT in this patient population. METHODS: We prospectively recruited 70 consecutive patients (69 women, one man; mean age, 61.9 ± 8.1 years) with early primary breast cancer for staging with (18)F-FDG-PET-CT. All PET-CT images were interpreted by two readers (independently of each other). A third reader adjudicated any discrepancies. All readers had ≥5 years of specific experience. Ethics board approval and informed consent were obtained. RESULTS: The mean clinical follow-up was 22.7 ± 12.6 months. The primary tumor was identified with PET-CT in 64 of 70 patients. Of the unidentified lesions, surgical pathology revealed two intraductal carcinomas, one invasive tubular carcinoma, and three invasive lobular carcinomas. Undiagnosed multifocal breast disease was shown in seven of 70 patients. PET-CT identified avid axillary lymph nodes in 19 of 70 patients, compared with 24 of 70 confirmed during surgery. There were four patients who were axillary node positive on PET but had no axillary disease at surgery. Five patients were reported with avid metastases. Two of those patients were treated for metastatic disease (nodal, lung, and liver in one and bone metastases in the other) following further imaging and clinical assessment. In the other three patients, lesions (lung, n = 1; pleural, n = 1; paratrachael node, n = 1) were subsequently diagnosed as benign lesions. CONCLUSION: Integrated (18)F-FDG-PET-CT may have a role in staging patients presenting with early breast cancer.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias/métodos , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA