Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Acoust Soc Am ; 152(1): 67, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35931512

RESUMEN

This study investigated the number of channels needed for maximum speech understanding and sound quality in 15 adult cochlear implant (CI) recipients with Advanced Bionics (AB) Mid-Scala electrode arrays completely within scala tympani. In experiment I, CI programs used a continuous interleaved sampling (CIS)-based strategy and 4-16 active electrodes. In experiment II, CI programs used an n-of-m strategy featuring 16 active electrodes with either 8- or 12-maxima. Speech understanding and sound quality measures were assessed. For CIS programs, participants demonstrated performance gains using up to 4-10 electrodes on speech measures and sound quality ratings. For n-of-m programs, there was no significant effect of maxima, suggesting 8-maxima is sufficient for this sample's maximum performance and sound quality. These results are largely consistent with previous studies using straight electrode arrays [e.g., Fishman, Shannon, and Slattery (1997). J. Speech Lang. Hear. Res. 40, 1201-1215; Friesen, Shannon, Baskent, and Wang (2001). J. Acoust. Soc. Am. 110, 1150-1163; Shannon, Cruz, and Galvin (2011). Audiol. Neurotol. 16, 113-123; Berg, Noble, Dawant, Dwyer, Labadie, and Gifford (2020). J. Acoust. Soc. Am. 147, 3646-3656] and in contrast with recent studies looking at cochlear precurved electrode arrays [e.g., Croghan, Duran, and Smith (2017). J. Acoust. Soc. Am. 142, EL537-EL543; Berg, Noble, Dawant, Dwuer, Labadie, and Gifford (2019b). J. Acoust. Soc. Am. 145, 1556-1564], which found continuous improvements up to 16 independent channels. These findings suggest that Mid-Scala electrode array recipients demonstrate similar channel independence to straight electrode arrays rather than other manufacturer's precurved electrode arrays.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Implantación Coclear/métodos , Humanos , Rampa Timpánica/cirugía , Habla
2.
J Acoust Soc Am ; 149(4): 2752, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33940865

RESUMEN

This study investigated the number of channels available to cochlear implant (CI) recipients for maximum speech understanding and sound quality for lateral wall electrode arrays-which result in large electrode-to-modiolus distances-featuring the greatest inter-electrode distances (2.1-2.4 mm), the longest active lengths (23.1-26.4 mm), and the fewest number of electrodes commercially available. Participants included ten post-lingually deafened adult CI recipients with MED-EL electrode arrays (FLEX28 and STANDARD) entirely within scala tympani. Electrode placement and scalar location were determined using computerized tomography. The number of channels was varied from 4 to 12 with equal spatial distribution across the array. A continuous interleaved sampling-based strategy was used. Speech recognition, sound quality ratings, and a closed-set vowel recognition task were measured acutely for each electrode condition. Participants did not demonstrate statistically significant differences beyond eight channels at the group level for almost all measures. However, several listeners showed considerable improvements from 8 to 12 channels for speech and sound quality measures. These results suggest that channel interaction caused by the greater electrode-to-modiolus distances of straight electrode arrays could be partially compensated for by a large inter-electrode distance or spacing.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Rampa Timpánica/cirugía , Habla
3.
J Acoust Soc Am ; 147(5): 3646, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32486813

RESUMEN

This study investigated the effects of cochlear implant (CI) electrode array type and scalar location on the number of channels available to CI recipients for maximum speech understanding and sound quality. Eighteen post-lingually deafened adult CI recipients participated, including 11 recipients with straight electrode arrays entirely in scala tympani and 7 recipients with translocated precurved electrode arrays. Computerized tomography was used to determine electrode placement and scalar location. In each condition, the number of channels varied from 4 to 22 with equal spatial distribution across the array. Speech recognition (monosyllables, sentences in quiet and in noise), subjective speech sound quality, and closed-set auditory tasks (vowels, consonants, and spectral modulation detection) were measured acutely. Recipients with well-placed straight electrode arrays and translocated precurved electrode arrays performed similarly, demonstrating asymptotic speech recognition scores with 8-10 channels, consistent with the classic literature. This finding contrasts with recent work [Berg, Noble, Dawant, Dwyer, Labadie, and Gifford. (2019). J. Acoust. Soc. Am. 145, 1556-1564] that found precurved electrode arrays well-placed in scala tympani demonstrate continuous performance gains beyond 8-10 channels. Given these results, straight and translocated precurved electrode arrays are theorized to have less channel independence secondary to their placement farther away from neural targets.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Rampa Timpánica/cirugía , Habla
4.
J Acoust Soc Am ; 145(3): 1556, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-31067952

RESUMEN

This study investigated the number of channels needed for maximum speech understanding and sound quality in 30 adult cochlear implant (CI) recipients with perimodiolar electrode arrays verified via imaging to be completely within scala tympani (ST). Performance was assessed using a continuous interleaved sampling (CIS) strategy with 4, 8, 10, and 16 channels and n-of-m with 16 maxima. Listeners were administered auditory tasks of speech understanding [monosyllables, sentences (quiet and +5 dB signal-to-noise ratio, SNR), vowels, consonants], spectral modulation detection, as well as subjective estimates of sound quality. Results were as follows: (1) significant performance gains were observed for speech in quiet (monosyllables and sentences) with 16- as compared to 8-channel CIS, (2) 16 channels in a 16-of-m strategy yielded significantly higher outcomes than 16-channel CIS for sentences in noise (percent correct and subjective sound quality) and spectral modulation detection, (3) 16 channels in a 16-of-m strategy yielded significantly higher outcomes as compared to 8- and 10-channel CIS for monosyllables, sentences (quiet and noise), consonants, spectral modulation detection, and subjective sound quality, (4) 16 versus 8 maxima yielded significantly higher speech recognition for monosyllables and sentences in noise using an n-of-m strategy, and (5) the degree of benefit afforded by 16 versus 8 maxima was inversely correlated with mean electrode-to-modiolus distance. These data demonstrate greater channel independence with perimodiolar electrode arrays as compared to previous studies with straight electrodes and warrant further investigation of the minimum number of maxima and number of channels needed for maximum auditory outcomes.


Asunto(s)
Implantes Cocleares/normas , Software de Reconocimiento del Habla , Habla , Adulto , Anciano , Anciano de 80 o más Años , Electrodos/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fonética
5.
Otol Neurotol ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38923968

RESUMEN

OBJECTIVES: To assess the clinical utility of spread of excitation (SOE) functions obtained via electrically evoked compound action potentials (eCAP) to 1) identify electrode array tip fold-over, 2) predict electrode placement factors confirmed via postoperative computed tomography (CT) imaging, and 3) predict postoperative speech recognition through the first year post-activation in a large clinical sample. STUDY DESIGN: Retrospective case review. SETTING: Cochlear implant (CI) program at a tertiary medical center. PATIENTS: Two hundred seventy-two ears (238 patients) with Cochlear Ltd. CIs (mean age = 46 yr, range = 9 mo-93 yr, 50% female) implanted between August 2014 and December 2022 were included. MAIN OUTCOME MEASURES: eCAP SOE widths (mm) (probe electrodes 5, 11, and 17), incidence of electrode tip fold-over, CT imaging data (electrode-to-modiolus distance, angular insertion depth, scalar location), and speech recognition outcomes (consonant-nucleus-consonant [CNC], AzBio quiet, and +5 dB SNR) through the first year after CI activation. RESULTS: 1) eCAP SOE demonstrated a sensitivity of 85.7% for identifying tip fold-over instances that were confirmed by CT imaging. In the current dataset, the tip fold-over incidence rate was 3.1% (7 patients), with all instances involving a precurved electrode array. 2) There was a significant positive relationship between eCAP SOE and mean electrode-to-modiolus distance for precurved arrays, and a significant positive relationship between eCAP SOE and angular insertion depth for straight arrays. No relationships between eCAP SOE and scalar location or cochlea diameter were found in this sample. 3) There were no significant relationships between eCAP SOE and speech recognition outcomes for any measure or time point, except for a weak negative correlation between average eCAP SOE widths and CNC word scores at 6 months post-activation for precurved arrays. CONCLUSIONS: In the absence of intraoperative CT or fluoroscopic imaging, eCAP SOE is a reasonable alternative method for identifying electrode array tip fold-over and should be routinely measured intraoperatively, especially for precurved electrode arrays with a sheath.

6.
Otol Neurotol ; 44(8): e635-e640, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37550889

RESUMEN

OBJECTIVE: To develop an evidence-based protocol for audiology-based, cochlear implant (CI) programming in the first year after activation. STUDY DESIGN: Retrospective case review. SETTING: CI program at a tertiary medical center. PATIENTS: One-hundred seventy-one patients (178 ears; mean age at implantation, 62.3 yr; 44.4% female) implanted between 2016 and 2021 with postlingual onset of deafness and no history of CI revision surgery. Patients included here had confirmed CI programming optimization based on CI-aided thresholds in the 20- to 30-dB-HL range as well as upper stimulation levels guided by electrically evoked stapedial reflex thresholds. MAIN OUTCOME MEASURES: Consonant-nucleus-consonant monosyllabic word recognition scores in the CI-alone and bilateral best-aided conditions at five time points: preoperative evaluation, and 1, 3, 6, and 12 months after activation. RESULTS: For both the CI-alone and bilateral best-aided conditions, consonant-nucleus-consonant word recognition significantly improved from preoperative evaluation to all postactivation time points. For the CI-alone condition, no significant differences were observed between 3 and 6 months, or from 6 to 12 months after activation. In contrast, for the bilateral best-aided condition, significant differences were observed between 1 and 3 months, and 3 and 6 months, but no difference in scores between 6 and 12 months. CONCLUSIONS: Based on the current data set and associated analyses, CI centers programming adult patients could eliminate either the 3- or 6-month visit from their clinical follow-up schedule if patient mapping of lower and upper stimulation levels is validated via CI-aided audiometric thresholds and electrically evoked stapedial reflex thresholds, respectively.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Femenino , Masculino , Estudios Retrospectivos , Percepción del Habla/fisiología , Implantación Coclear/métodos , Audiometría , Resultado del Tratamiento
7.
Am J Audiol ; 32(2): 403-416, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37249492

RESUMEN

PURPOSE: This study investigated the relationship between the number of active electrodes, channel stimulation rate, and their interaction on speech recognition and sound quality measures while controlling for electrode placement. Cochlear implant (CI) recipients with precurved electrode arrays placed entirely within scala tympani and closer to the modiolus were hypothesized to be able to utilize more channels and possibly higher stimulation rates to achieve better speech recognition performance and sound quality ratings than recipients in previous studies. METHOD: Participants included seven postlingually deafened adult CI recipients with Advanced Bionics Mid-Scala electrode arrays confirmed to be entirely within scala tympani using postoperative computerized tomography. Twelve conditions were tested using four, eight, 12, and 16 electrodes and channel stimulation rates of 600 pulse per second (pps), 1,200 pps, and each participant's maximum allowable rate (1,245-4,800 pps). Measures of speech recognition and sound quality were acutely assessed. RESULTS: For the effect of channels, results showed no significant improvements beyond eight channels for all measures. For the effect of channel stimulation rate, results showed no significant improvements with higher rates, suggesting that 600 pps was sufficient for maximum speech recognition performance and sound quality ratings. However, across all conditions, there was a significant relationship between mean electrode-to-modiolus distance and all measures, suggesting that a lower mean electrode-to-modiolus distance was correlated with higher speech recognition scores and sound quality ratings. CONCLUSION: These findings suggest that even well-placed precurved electrode array recipients may not be able to take advantage of more than eight channels or higher channel stimulation rates (> 600 pps), but that closer electrode array placement to the modiolus correlates with better outcomes for these recipients.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Percepción del Habla/fisiología , Cóclea , Implantación Coclear/métodos , Rampa Timpánica/cirugía
8.
Otol Neurotol ; 44(7): 672-678, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37367733

RESUMEN

OBJECTIVE: To quantify the roles and relationships between age at implantation, duration of deafness (DoD), and daily processor use via data logging on speech recognition outcomes for postlingually deafened adults with cochlear implants. STUDY DESIGN: Retrospective case review. SETTING: Cochlear implant (CI) program at a tertiary medical center. PATIENTS: Six-hundred fourteen postlingually deafened adult ears with CIs (mean age, 63 yr; 44% female) were included. MAIN OUTCOME MEASURES: A stepwise multiple regression analysis was completed to investigate the combined effects of age, DoD, and daily processor use on CI-aided speech recognition (Consonant-Nucleus-Consonant monosyllables and AzBio sentences). RESULTS: Results indicated that only daily processor use was significantly related to Consonant-Nucleus-Consonant word scores ( R2 = 0.194, p < 0.001) and AzBio in quiet scores ( R2 = 0.198, p < 0.001), whereas neither age nor DoD was significantly related. In addition, there was no significant relationship between daily processor use, age at implantation, or DoD and AzBio sentences in noise ( R2 = 0.026, p = 0.005). CONCLUSIONS: Considering the clinical factors of age at implantation, DoD, and daily processor use, only daily processor use significantly predicted the ~20% of variance in postoperative outcomes (CI-aided speech recognition) accounted for by these clinical factors.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Percepción del Habla , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Estudios Retrospectivos , Implantación Coclear/métodos , Sordera/cirugía , Sordera/rehabilitación , Resultado del Tratamiento
9.
JASA Express Lett ; 2(9): 094403, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36182337

RESUMEN

This study investigated the number of channels required for asymptotic speech recognition for ten pediatric cochlear implant (CI) recipients with precurved electrode arrays. Programs with 4-22 active electrodes were used to assess word and sentence recognition in noise. Children demonstrated significant performance gains up to 12 electrodes for continuous interleaved sampling (CIS) and up to 22 channels with 16 maxima. These data are consistent with the latest adult CI studies demonstrating that modern CI recipients have access to more than 8 independent channels and that both adults and children exhibit performance gains up to 22 channels.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Niño , Humanos , Ruido , Habla
10.
Biomed Phys Eng Express ; 9(1)2022 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-36594887

RESUMEN

Objective. The cochlear implant is a neural prosthesis designed to directly stimulate auditory nerve fibers to induce the sensation of hearing in those experiencing severe-to-profound hearing loss. After surgical implantation, audiologists program the implant's external processor with settings intended to produce optimal hearing outcomes. The likelihood of achieving optimal outcomes increases when audiologists have access to tools that objectively present information related to the patient's own anatomy and surgical outcomes. This includes visualizations like the one presented here, termed the activation region overlap image, which is designed to decrease subjectivity when determining amounts of overlapping stimulation between implant electrodes.Approach. This visualization uses estimates of electric field strength to indicate spread of neural excitation due to each electrode. Unlike prior visualizations, this method explicitly defines regions of nerves receiving substantial stimulation from each electrode to help clinicians assess the presence of significant overlapping stimulation. A multi-reviewer study compared this and an existing technique on the consistency, efficiency, and optimality of plans generated from each method. Statistical significance was evaluated using the two-sided Wilcoxon rank sum test.Main results. The study showed statistically significant improvements in consistency (p < 10-12), efficiency (p < 10-15), and optimality (p < 10-5) when generating plans using the proposed method versus the existing method.Significance. This visualization addresses subjectivity in assessing overlapping stimulation between implant electrodes, which currently relies on reviewer estimates. The results of the evaluation indicate the provision of such objective information during programming sessions would likely benefit clinicians in making programming decisions.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Electrodos Implantados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA