1.
Anesth Analg ; 138(3): 552-561, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38109495

RESUMEN

BACKGROUND: Retrospective clinical trials of pulse oximeter accuracy report more frequent missed diagnoses of hypoxemia in hospitalized Black patients than White patients, differences that may contribute to racial disparities in health and health care. Retrospective studies have limitations including mistiming of blood samples and oximeter readings, inconsistent use of functional versus fractional saturation, and self-reported race used as a surrogate for skin color. Our objective was to prospectively measure the contributions of skin pigmentation, perfusion index (PI), sex, and age on pulse oximeter errors in a laboratory setting. METHODS: We enrolled 146 healthy subjects, including 25 with light skin (Fitzpatrick class I and II), 78 with medium (class III and IV), and 43 with dark (class V and VI) skin. We studied 2 pulse oximeters (Nellcor N-595 and Masimo Radical 7) in prevalent clinical use. We analyzed 9763 matched pulse oximeter readings (pulse oximeter measured functional saturation [Sp o2 ]) and arterial oxygen saturation (hemoximetry arterial functional oxygen saturation [Sa o2 ]) during stable hypoxemia (Sa o2 68%-100%). PI was measured as percent infrared light modulation by the pulse detected by the pulse oximeter probe, with low perfusion categorized as PI < 1%. The primary analysis was to assess the relationship between pulse oximeter bias (difference between Sa o2 and Sp o2 ) by skin pigment category in a multivariable mixed-effects model incorporating repeated-measures and different levels of Sa o2 and perfusion. RESULTS: Skin pigment, PI, and degree of hypoxemia significantly contributed to errors (bias) in both pulse oximeters. For PI values of 1.0% to 1.5%, 0.5% to 1.0%, and <0.5%, the P value of the relationship to mean bias or median absolute bias was <.00001. In lightly pigmented subjects, only PI was associated with positive bias, whereas in medium and dark subjects bias increased with both low perfusion and degree of hypoxemia. Sex and age was not related to pulse oximeter bias. The combined frequency of missed diagnosis of hypoxemia (pulse oximeter readings 92%-96% when arterial oxygen saturation was <88%) in low perfusion conditions was 1.1% for light, 8.2% for medium, and 21.1% for dark skin. CONCLUSIONS: Low peripheral perfusion combined with darker skin pigmentation leads to clinically significant high-reading pulse oximeter errors and missed diagnoses of hypoxemia. Darkly pigmented skin and low perfusion states are likely the cause of racial differences in pulse oximeter performance in retrospective studies.


Asunto(s)
Diagnóstico Erróneo , Oximetría , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Hipoxia/diagnóstico , Oxígeno , Perfusión
2.
Proc Natl Acad Sci U S A ; 115(45): E10740-E10747, 2018 11 06.
Artículo en Inglés | MEDLINE | ID: mdl-30348769

RESUMEN

Orexin (also known as hypocretin) neurons in the hypothalamus play an essential role in sleep-wake control, feeding, reward, and energy homeostasis. The likelihood of anesthesia and sleep sharing common pathways notwithstanding, it is important to understand the processes underlying emergence from anesthesia. In this study, we investigated the role of the orexin system in anesthesia emergence, by specifically activating orexin neurons utilizing the designer receptors exclusively activated by designer drugs (DREADD) chemogenetic approach. With injection of adeno-associated virus into the orexin-Cre transgenic mouse brain, we expressed the DREADD receptor hM3Dq specifically in orexin neurons and applied the hM3Dq ligand clozapine to activate orexin neurons. We monitored orexin neuronal activities by c-Fos staining and whole-cell patch-clamp recording and examined the consequence of orexin neuronal activation via EEG recording. Our results revealed that the orexin-DREADD mice with activated orexin neurons emerged from anesthesia with significantly shorter latency than the control mice. As an indication of reduced pain sensitivity, these orexin-DREADD mice took longer to respond to the 55 °C thermal stimuli in the hot plate test and exhibited significantly less frequent licking of the formalin-injected paw in the formalin test. Our study suggests that approaches to activate the orexin system can be beneficial in postoperative recovery.


Asunto(s)
Periodo de Recuperación de la Anestesia , Hipotálamo/metabolismo , Neuronas/metabolismo , Receptores de Orexina/genética , Orexinas/genética , Dolor/genética , Anestésicos por Inhalación , Animales , Clozapina/farmacología , Dependovirus/genética , Dependovirus/metabolismo , Electroencefalografía , Regulación de la Expresión Génica , Vectores Genéticos/química , Vectores Genéticos/metabolismo , Calor , Hipotálamo/efectos de los fármacos , Hipotálamo/fisiopatología , Isoflurano , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Neuronas/efectos de los fármacos , Neuronas/patología , Receptores de Orexina/metabolismo , Orexinas/metabolismo , Dolor/fisiopatología , Dolor/prevención & control , Dimensión del Dolor , Técnicas de Placa-Clamp , Proteínas Proto-Oncogénicas c-fos/genética , Proteínas Proto-Oncogénicas c-fos/metabolismo , Antagonistas de la Serotonina/farmacología , Técnicas Estereotáxicas
3.
JAMA ; 331(24): 2075-2076, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38809524

RESUMEN

This Viewpoint discusses the recent use of forced nitrogen inhalation as capital punishment in Alabama and describes the body of evidence indicating that forced nitrogen inhalation is an inhumane practice.


Asunto(s)
Pena de Muerte , Hipoxia , Nitrógeno , Tortura , Humanos , Pena de Muerte/legislación & jurisprudencia , Pena de Muerte/métodos , Nitrógeno/administración & dosificación , Estados Unidos , Administración por Inhalación , Hipoxia/etiología
4.
Anesthesiology ; 128(1): 97-108, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29084012

RESUMEN

BACKGROUND: Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. METHODS: Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. RESULTS: FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P < 0.001). The INVOS 5100C bias was also lower during normocapnia (5 ± 15% vs. 3 ± 12%; P = 0.01). Hypocapnia resulted in a significant decrease in mixed venous oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P < 0.0001). Bias increased significantly with increasing oxygen extraction (P < 0.0001). CONCLUSIONS: Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/metabolismo , Dióxido de Carbono/sangre , Circulación Cerebrovascular/fisiología , Oximetría/métodos , Oxígeno/sangre , Adulto , Femenino , Humanos , Masculino , Presión Parcial , Arteria Radial/metabolismo , Adulto Joven
5.
Anesthesiology ; 128(3): 520-530, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29200008

RESUMEN

BACKGROUND: Pulse oximeter performance is degraded by motion artifacts and low perfusion. Manufacturers developed algorithms to improve instrument performance during these challenges. There have been no independent comparisons of these devices. METHODS: We evaluated the performance of four pulse oximeters (Masimo Radical-7, USA; Nihon Kohden OxyPal Neo, Japan; Nellcor N-600, USA; and Philips Intellivue MP5, USA) in 10 healthy adult volunteers. Three motions were evaluated: tapping, pseudorandom, and volunteer-generated rubbing, adjusted to produce photoplethsmogram disturbance similar to arterial pulsation amplitude. During motion, inspired gases were adjusted to achieve stable target plateaus of arterial oxygen saturation (SaO2) at 75%, 88%, and 100%. Pulse oximeter readings were compared with simultaneous arterial blood samples to calculate bias (oxygen saturation measured by pulse oximetry [SpO2] - SaO2), mean, SD, 95% limits of agreement, and root mean square error. Receiver operating characteristic curves were determined to detect mild (SaO2 < 90%) and severe (SaO2 < 80%) hypoxemia. RESULTS: Pulse oximeter readings corresponding to 190 blood samples were analyzed. All oximeters detected hypoxia but motion and low perfusion degraded performance. Three of four oximeters (Masimo, Nellcor, and Philips) had root mean square error greater than 3% for SaO2 70 to 100% during any motion, compared to a root mean square error of 1.8% for the stationary control. A low perfusion index increased error. CONCLUSIONS: All oximeters detected hypoxemia during motion and low-perfusion conditions, but motion impaired performance at all ranges, with less accuracy at lower SaO2. Lower perfusion degraded performance in all but the Nihon Kohden instrument. We conclude that different types of pulse oximeters can be similarly effective in preserving sensitivity to clinically relevant hypoxia.


Asunto(s)
Hipoxia/diagnóstico , Oximetría/instrumentación , Adulto , Algoritmos , Artefactos , Femenino , Humanos , Masculino , Movimiento (Física) , Oxígeno , Valores de Referencia , Reproducibilidad de los Resultados , Adulto Joven
6.
Anesth Analg ; 126(2): 579-587, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29189269

RESUMEN

BACKGROUND: Currently, no reliable method exists for continuous, noninvasive measurements of absolute cerebral blood flow (CBF). We sought to determine how changes measured by ultrasound-tagged near-infrared spectroscopy (UT-NIRS) compare with changes in CBF as measured by transcranial Doppler (TCD) in healthy volunteers during profound hypocapnia and hypercapnia. METHODS: Ten healthy volunteers were monitored with a combination of TCD, UT-NIRS (c-FLOW, Ornim Medical), as well as heart rate, blood pressure, end-tidal PCO2 (PEtCO2), end-tidal O2, and inspired O2. Inspired CO2 and minute ventilation were controlled to achieve 5 stable plateau goals of EtCO2 at 15-20, 25-30, 35-40, 45-50, and 55-60 mm Hg, for a total of 7 measurements per subject. CBF was assessed at a steady state, with the TCD designated as the reference standard. The primary analysis was a linear mixed-effect model of TCD and UT-NIRS flow with PEtCO2, which accounts for repeated measures. Receiver operating characteristic curves were determined for detection of changes in CBF. RESULTS: Hyperventilation (nadir PEtCO2 17.1 ± 2.4) resulted in significantly decreased mean flow velocity of the middle cerebral artery from baseline (to 79% ± 22%), but not a consistent decrease in UT-NIRS cerebral flow velocity index (n = 10; 101% ± 6% of baseline). Hypercapnia (peak PEtCO2 59.3 ± 3.3) resulted in a significant increase from baseline in both mean flow velocity of the middle cerebral artery (153% ± 25%) and UT-NIRS (119% ± 11%). Comparing slopes versus PEtCO2 as a percent of baseline for the TCD (1.7% [1.5%-2%]) and UT-NIRS (0.4% [0.3%-0.5%]) shows that the UT-NIRS slope is significantly flatter, P < .0001. Area under the receiver operating characteristic curve was significantly higher for the TCD than for UT-NIRS, 0.97 (95% confidence interval, 0.92-0.99) versus 0.75 (95% confidence interval, 0.66-0.82). CONCLUSIONS: Our data indicate that UT-NIRS cerebral flow velocity index detects changes in CBF only during hypercarbia but not hypocarbia in healthy subjects and with much less sensitivity than TCD. Additional refinement and validation are needed before widespread clinical utilization of UT-NIRS.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Circulación Cerebrovascular/fisiología , Espectroscopía Infrarroja Corta/métodos , Ultrasonografía Doppler Transcraneal/métodos , Adulto , Femenino , Humanos , Masculino , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/normas , Espectroscopía Infrarroja Corta/normas , Ultrasonografía Doppler Transcraneal/normas
7.
Anesth Analg ; 125(1): 124-138, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28489640

RESUMEN

Implanted electronic medical devices. or stimulators such as pacemakers and nerve stimulators have grown enormously in diversity and complexity over recent decades. The function and potential interaction of these devices with the perioperative environment is of increasing concern for anesthesiologists and surgeons. Because of the innate electromagnetic environment of the hospital (operating room, gastrointestinal procedure suite, and imaging suite), implanted device malfunction, reprogramming, or destruction may occur and cause physical harm (including nerve injury, blindness, deafness, burn, stroke, paralysis, or coma) to the patient. It is critical for the anesthesiologist and surgeon to be aware of the function and interaction of implanted devices, both with other implanted devices and procedures (such as magnetic resonance imaging and cardioversion) in the hospital environment. Because of these interactions, it is imperative that proper device function is assessed when the surgical procedure is complete. This review article will discuss these important issues for 12 different types of "little black boxes," or noncardiac implantable electronic medical devices.


Asunto(s)
Anestesiología/métodos , Cardioversión Eléctrica/instrumentación , Electrodos Implantados , Prótesis Neurales , Atención Perioperativa/instrumentación , Anestésicos , Desfibriladores Implantables , Campos Electromagnéticos , Electrónica , Endoscopía , Ganglios Espinales , Humanos , Imagen por Resonancia Magnética , Marcapaso Artificial , Seguridad del Paciente , Nervio Frénico , Periodo Posoperatorio , Retina , Sacro/inervación , Médula Espinal , Estimulación Eléctrica Transcutánea del Nervio , Nervio Vago
8.
Anesth Analg ; 124(1): 146-153, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27529318

RESUMEN

Extended periods of oxygen deprivation can produce acidosis, inflammation, energy failure, cell stress, or cell death. However, brief profound hypoxia (here defined as SaO2 50%-70% for approximately 10 minutes) is not associated with cardiovascular compromise and is tolerated by healthy humans without apparent ill effects. In contrast, chronic hypoxia induces a suite of adaptations and stresses that can result in either increased tolerance of hypoxia or disease, as in adaptation to altitude or in the syndrome of chronic mountain sickness. In healthy humans, brief profound hypoxia produces increased minute ventilation and increased cardiac output, but little or no alteration in blood chemistry. Central nervous system effects of acute profound hypoxia include transiently decreased cognitive performance, based on alterations in attention brought about by interruptions of frontal/central cerebral connectivity. However, provided there is no decrease in cardiac output or ischemia, brief profound hypoxemia in healthy humans is well tolerated without evidence of acidosis or lasting cognitive impairment.


Asunto(s)
Hipoxia/diagnóstico , Oximetría , Oxígeno/sangre , Acidosis/etiología , Acidosis/fisiopatología , Enfermedad Aguda , Adaptación Fisiológica , Animales , Atención , Biomarcadores/sangre , Encéfalo/fisiopatología , Gasto Cardíaco , Cognición , Trastornos del Conocimiento/etiología , Trastornos del Conocimiento/fisiopatología , Trastornos del Conocimiento/psicología , Modelos Animales de Enfermedad , Humanos , Hipoxia/sangre , Hipoxia/complicaciones , Hipoxia/fisiopatología , Valor Predictivo de las Pruebas , Ventilación Pulmonar , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo