Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Cardiovasc Surg (Torino) ; 47(3): 349-52, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16760872

RESUMEN

Dissection of the interventricular septum (IVS) is a rare condition, which can uncommonly complicate an acute myocardial infarction (AMI). We describe a case of unruptured IVS dissection observed 16 days after 2 close episodes of AMI. The diagnosis was made by transthoracic echocardiography. An echo-free space within the thickness of IVS, extended from the apex to the mid-portion, for a total length of about 30 mm was evident. The careful examination of the left ventricle did not reveal any discontinuity of the myocardial wall. The stable clinical condition, the absence of flow within the dissection, the demonstration of its favourable evolution during the hospitalisation and the characteristics of the underlying coronary disease (left anterior descending artery occlusion without myocardial viability) led to the decision of avoiding surgery. The predischarge contrast echocardiographic examination (Levovist) showed clearly the border of the infarcted zone and demonstrated an area reduction and echogenicity increase of the neocavitation, with partially organised thrombi. The patient recovered uneventfully and was discharged on medical therapy with a clinical and echocardiographic follow-up program. We believe that for IVS hemorrhagic dissection a nonsurgical option can be proposed; surgery should only be considered for myocardial revascularization when indicated. A close echocardiographic follow-up is mandatory.


Asunto(s)
Disección Aórtica/patología , Cardiomiopatías/patología , Tabiques Cardíacos/patología , Anciano , Disección Aórtica/diagnóstico , Disección Aórtica/etiología , Cardiomiopatías/diagnóstico , Cardiomiopatías/etiología , Angiografía Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico , Ecocardiografía Doppler en Color , Femenino , Tabiques Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Radiografía Torácica
2.
Ann Thorac Surg ; 72(1): 33-8, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11465226

RESUMEN

BACKGROUND: This study compares the hemodynamic performance of stented and stentless bioprostheses used for aortic valve replacement in patients with aortic stenosis and small aortic root. METHODS: Between 1995 and 1998, 37 patients with a 21-mm aortic annulus (group 1) underwent aortic valve replacement with either a 21-mm Edwards Perimount or a 23-mm St. Jude Toronto bioprosthesis whereas 47 patients with a 23-mm aortic annulus (group 2) received either a 23-mm Medtronic Mosaic or a 25-mm Edwards Prima bioprosthesis. In each group mean and peak gradients, effective orifice area index, and left ventricular mass index were compared during follow-up. RESULTS: Group 1 patients showed a significant reduction of mean (p < 0.001) and peak gradients (p = 0.001) during follow-up, more evident for St. Jude Toronto versus Edwards Perimount (p = 0.02 and p = 0.05, respectively). Group 2 patients showed a significant reduction of mean and peak gradients (p < 0.001), more evident for Edwards Prima versus Medtronic Mosaic (p < 0.001 and p = 0.07, respectively). Effective orifice area index significantly increased only in group 1 (p = 0.005). Left ventricular mass index significantly decreased in all patients regardless of the type of valve (p < 0.001). Patients with Edwards Prima showed a trend to a higher regression of left ventricular mass index versus Medtronic Mosaic recipients (p = 0.07). CONCLUSIONS: After aortic valve replacement, stented and stentless bioprostheses exhibited similar results with a more evident hemodynamic improvement during follow-up in the stentless valves. Stented bioprostheses of new generation, however, may parallel the hemodynamic performance of stentless valves and appear to be a valid alternative for aortic valve replacement in elderly patients with a small aortic annulus.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Complicaciones Posoperatorias/fisiopatología , Stents , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Velocidad del Flujo Sanguíneo/fisiología , Presión Sanguínea/fisiología , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos
3.
Heart Lung Vessel ; 6(3): 171-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25279359

RESUMEN

INTRODUCTION: Postoperative atrial fibrillation after isolated coronary revascularization has been associated with increased morbidity and mortality. Aim of present investigation was to evaluate incidence of postoperative atrial fibrillation and its prognostic role in patients undergoing isolated coronary artery by-pass and disclose possible differences between off-pump and cardiopulmonary assisted revascularization. METHODS: Prospective cohort study of 229 patients undergoing isolated coronary artery by-pass at a tertiary heart surgery Centre. Off-pump treated patients were significantly older (70.5 vs 64.9 years, p<0.001). No other baseline differences were found. Patients who developed postoperative atrial fibrillation were followed up for an average period of 2 years. RESULTS: Post-operative occurred in 56/229 (24.1% after cardiopulmonary and 24.6% after off-pump coronary artery by-pass). Left atrium diameter was the only independent predictive factor (odds ratio =1.15, 95% confidence interval 1.02-1.30, p<0.001). All patients with postoperative atrial fibrillation were treated and discharged in sinus rhythm, in 6/56 recurred, only in one persisted. One patient died during follow up. No stroke was recorded. CONCLUSIONS: After isolated surgical revascularization, atrial fibrillation occurred in 24% without differences related to operative technique. Recurrence of atrial fibrillation occurred in 6/56 patients (10.7%) however only in 1 persisted. Early and late mortality did not show relation with post-operative atrial fibrillation probably due to immediate treatment with recovery of sinus rhythm before discharge.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA