Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 447
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(16): 1458-1473, 2024 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-38430485

RESUMEN

BACKGROUND AND AIMS: Cardiopulmonary fitness in congenital heart disease (CHD) decreases faster than in the general population resulting in impaired health-related quality of life (HRQoL). As the standard of care seems insufficient to encourage and maintain fitness, an early hybrid cardiac rehabilitation programme could improve HRQoL in CHD. METHODS: The QUALIREHAB multicentre, randomized, controlled trial evaluated and implemented a 12-week centre- and home-based hybrid cardiac rehabilitation programme, including multidisciplinary care and physical activity sessions. Adolescent and young adult CHD patients with impaired cardiopulmonary fitness were randomly assigned to either the intervention (i.e. cardiac rehabilitation) or the standard of care. The primary outcome was the change in HRQoL from baseline to 12-month follow-up in an intention-to-treat analysis. The secondary outcomes were the change in cardiovascular parameters, cardiopulmonary fitness, and mental health. RESULTS: The expected number of 142 patients was enroled in the study (mean age 17.4 ± 3.4 years, 52% female). Patients assigned to the intervention had a significant positive change in HRQoL total score [mean difference 3.8; 95% confidence interval (CI) 0.2; 7.3; P = .038; effect size 0.34], body mass index [mean difference -0.7 kg/m2 (95% CI -1.3; -0.1); P = .022; effect size 0.41], level of physical activity [mean difference 2.5 (95% CI 0.1; 5); P = .044; effect size 0.39], and disease knowledge [mean difference 2.7 (95% CI 0.8; 4.6); P = .007; effect size 0.51]. The per-protocol analysis confirmed these results with a higher magnitude of differences. Acceptability, safety, and short-time effect of the intervention were good to excellent. CONCLUSIONS: This early hybrid cardiac rehabilitation programme improved HRQoL, body mass index, physical activity, and disease knowledge, in youth with CHD, opening up the possibility for the QUALIREHAB programme to be rolled out to the adult population of CHD and non-congenital cardiac disease.


Asunto(s)
Rehabilitación Cardiaca , Cardiopatías Congénitas , Adolescente , Femenino , Humanos , Masculino , Adulto Joven , Rehabilitación Cardiaca/métodos , Ejercicio Físico , Terapia por Ejercicio , Calidad de Vida
2.
Eur Respir J ; 63(4)2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38514094

RESUMEN

BACKGROUND: Bone morphogenetic proteins 9 and 10 (BMP9 and BMP10), encoded by GDF2 and BMP10, respectively, play a pivotal role in pulmonary vascular regulation. GDF2 variants have been reported in pulmonary arterial hypertension (PAH) and hereditary haemorrhagic telangiectasia (HHT). However, the phenotype of GDF2 and BMP10 carriers remains largely unexplored. METHODS: We report the characteristics and outcomes of PAH patients in GDF2 and BMP10 carriers from the French and Dutch pulmonary hypertension registries. A literature review explored the phenotypic spectrum of these patients. RESULTS: 26 PAH patients were identified: 20 harbouring heterozygous GDF2 variants, one homozygous GDF2 variant, four heterozygous BMP10 variants, and one with both GDF2 and BMP10 variants. The prevalence of GDF2 and BMP10 variants was 1.3% and 0.4%, respectively. Median age at PAH diagnosis was 30 years, with a female/male ratio of 1.9. Congenital heart disease (CHD) was present in 15.4% of the patients. At diagnosis, most of the patients (61.5%) were in New York Heart Association Functional Class III or IV with severe haemodynamic compromise (median (range) pulmonary vascular resistance 9.0 (3.3-40.6) WU). Haemoptysis was reported in four patients; none met the HHT criteria. Two patients carrying BMP10 variants underwent lung transplantation, revealing typical PAH histopathology. The literature analysis showed that 7.6% of GDF2 carriers developed isolated HHT, and identified cardiomyopathy and developmental disorders in BMP10 carriers. CONCLUSIONS: GDF2 and BMP10 pathogenic variants are rare among PAH patients, and occasionally associated with CHD. HHT cases among GDF2 carriers are limited according to the literature. BMP10 full phenotypic ramifications warrant further investigation.


Asunto(s)
Hipertensión Pulmonar , Hipertensión Arterial Pulmonar , Telangiectasia Hemorrágica Hereditaria , Humanos , Masculino , Femenino , Adulto , Proteínas Morfogenéticas Óseas/genética , Proteínas Morfogenéticas Óseas/metabolismo , Hipertensión Pulmonar/diagnóstico , Hipertensión Arterial Pulmonar/genética , Hipertensión Arterial Pulmonar/complicaciones , Hipertensión Pulmonar Primaria Familiar , Telangiectasia Hemorrágica Hereditaria/complicaciones , Telangiectasia Hemorrágica Hereditaria/genética , Fenotipo , Factor 2 de Diferenciación de Crecimiento/genética , Estudios Multicéntricos como Asunto
3.
Nat Immunol ; 13(12): 1178-86, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23104095

RESUMEN

We report the clinical description and molecular dissection of a new fatal human inherited disorder characterized by chronic autoinflammation, invasive bacterial infections and muscular amylopectinosis. Patients from two kindreds carried biallelic loss-of-expression and loss-of-function mutations in HOIL1 (RBCK1), a component of the linear ubiquitination chain assembly complex (LUBAC). These mutations resulted in impairment of LUBAC stability. NF-κB activation in response to interleukin 1ß (IL-1ß) was compromised in the patients' fibroblasts. By contrast, the patients' mononuclear leukocytes, particularly monocytes, were hyper-responsive to IL-1ß. The consequences of human HOIL-1 and LUBAC deficiencies for IL-1ß responses thus differed between cell types, consistent with the unique association of autoinflammation and immunodeficiency in these patients. These data suggest that LUBAC regulates NF-κB-dependent IL-1ß responses differently in different cell types.


Asunto(s)
Enfermedad del Almacenamiento de Glucógeno Tipo IV/genética , Enfermedades Autoinflamatorias Hereditarias/genética , Síndromes de Inmunodeficiencia/genética , FN-kappa B/metabolismo , Ubiquitina-Proteína Ligasas/genética , Infecciones Bacterianas/genética , Infecciones Bacterianas/inmunología , Proteínas de Ciclo Celular/genética , Línea Celular , Fibroblastos/inmunología , Fibroblastos/metabolismo , Humanos , Síndromes de Inmunodeficiencia/metabolismo , Interleucina-1beta/metabolismo , Monocitos/inmunología , Monocitos/metabolismo , Análisis de Secuencia por Matrices de Oligonucleótidos , Proteínas Serina-Treonina Quinasas/antagonistas & inhibidores , Proteínas Serina-Treonina Quinasas/genética , Proteínas Represoras/genética , Factores de Transcripción , Ubiquitina-Proteína Ligasas/deficiencia , Ubiquitina-Proteína Ligasas/metabolismo , Ubiquitinación
4.
Eur J Pediatr ; 183(5): 1967-1987, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38353800

RESUMEN

The purpose of the study is to assess the risks of neurodevelopmental morbidity among preterm and growth restricted youth with congenital heart defects (CHD). This systematic review and meta-analysis included observational studies assessing neurodevelopmental outcomes among children with CHD born preterm (i.e., before 37 weeks of gestation) or growth restricted (small-for-gestational age (SGA) with a birthweight < the 10th percentile or with low birthweight (LBW) < 2500 g). Studies were identified in Medline and Embase databases from inception until May 2022, with data extracted by two blinded reviewers. Risk of bias was assessed using the Critical Appraisal Skills Programme cohort checklist. Meta-analysis involved the use of random-effects models. Main outcome measures were neurodevelopmental outcomes including overall cognitive impairment and intellectual disability, IQ, communication, and motor skills scores. From 3573 reports, we included 19 studies in qualitative synthesis and 6 meta-analysis studies. Risk of bias was low in 8/19 studies. Cognitive impairment and intellectual disability were found in 26% (95% CI 20-32, I2 = 0%) and 19% (95% CI 7-35, I2 = 82%) of preterm children with CHD, respectively. Two studies documented a lower IQ score for SGA children who underwent CHD operations in comparison to non-SGA children who also underwent CHD operations. Two studies have reported lower IQ, communication, and motor skills in children with hypoplastic left heart syndrome (HLHS) and low birth weight compared to those with HLHS and expected birth weight. CONCLUSIONS: Based on a low level of evidence, prematurity and/or growth retardation appear to accentuate specific neurodevelopmental outcomes in certain CHD subgroups. Further evidence is needed to confirm these findings. TRIAL REGISTRATION: PROSPERO [CRD42020201414]. WHAT IS KNOWN: • Children born with CHD, preterm birth, or growth restriction at birth are independently at higher risk for neurodevelopmental impairment. • The additional effect of preterm birth and/or growth restriction on neurodevelopmental outcomes in children with CHD remains unclear. WHAT IS NEW: • Prematurity and/or growth retardation appear to accentuate specific neurodevelopmental outcomes in certain CHD subgroups. • Children with CHD, particularly those born preterm or with growth restriction, should undergo lifelong systematic comprehensive neurodevelopmental assessment.


Asunto(s)
Cardiopatías Congénitas , Recien Nacido Prematuro , Recién Nacido Pequeño para la Edad Gestacional , Humanos , Recién Nacido , Cardiopatías Congénitas/complicaciones , Trastornos del Neurodesarrollo/etiología , Trastornos del Neurodesarrollo/epidemiología , Recién Nacido de Bajo Peso , Niño
5.
Acta Paediatr ; 113(5): 955-961, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38180109

RESUMEN

AIM: Transcatheter closure of the patent ductus arteriosus (TCPDA) is increasingly used in preterm infants as an alternative to surgical ligation. However, clinically ill preterm infants are at risk of contrast nephropathy due to the angiography contrast agents used during the procedure. METHODS: We performed a single-centre before-and-after comparative study in VLBW infants to compare the kinetics of serum creatinine during the first 4 days after TCPDA with or without angiography. RESULTS: 69 patients were included and divided into two groups: TCPDA with (contrast+; n = 37) and without (contrast-, n = 32) use of contrast agent. The median dose [range] of contrast agent was 1.0 mL/kg [0.6-2.4 mL/kg]. The change in serum creatinine level between day 2 to 4 after TCPCA and baseline decreased in the contrast- group (-17% [-46%; 18%]), while it increased in the contrast+ group (7% [-24%; 202%] p = 0.002). Comparison of blood urea levels between groups showed similar significant differences. The change in serum creatinine between day 2 to 4 and baseline was significantly correlated with the dose of contrast agent (r2 = 0.682; p < 0.001). CONCLUSION: The use of contrast agents during TCPDA can potentially harm the renal function of very preterm infants. Therefore, we advise minimising or avoiding the use of contrast agents.


Asunto(s)
Conducto Arterioso Permeable , Conducto Arterial , Enfermedades del Prematuro , Lactante , Recién Nacido , Humanos , Recien Nacido Prematuro , Medios de Contraste/efectos adversos , Creatinina , Conducto Arterioso Permeable/diagnóstico por imagen , Riñón/diagnóstico por imagen , Resultado del Tratamiento
6.
Pediatr Cardiol ; 45(1): 200-207, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37934240

RESUMEN

Absence of connection of both coronary arteries to the aorta is an extremely rare congenital malformation. Most cases reported are anatomic variants of anomalous left coronary artery to pulmonary artery, found in isolation or in association with other congenital heart defects. We describe here four cases of patients born without any coronary artery connected to the aorta, including two with an almost complete absence of epicardial coronary arteries, one with single coronary artery to the right pulmonary artery, and one with left ventricular connection of a single coronary artery. Those exceptional coronary malformations have a poor prognosis and are often diagnosed at autopsy. Total absence of epicardial coronary arteries, present in two of our patients and described only once in the literature, leads us to reconsider current knowledge of human coronary artery development.


Asunto(s)
Enfermedad de la Arteria Coronaria , Anomalías de los Vasos Coronarios , Humanos , Anomalías de los Vasos Coronarios/complicaciones , Aorta/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/anomalías , Enfermedad de la Arteria Coronaria/complicaciones
7.
Cardiol Young ; 34(1): 209-211, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38031499

RESUMEN

We report a 20-year-old female patient (76 Kg/164 cm) with an extra-cardiac Fontan circulation who was referred to our institution for exertional dyspnoea and desaturation. The patient was diagnosed with a large calcified thrombus at the level of the Fontan fenestration, protruding inside the lumen of the conduit and reducing the diameter by half with a 3 mmHg pressure gradient. Transcatheter stent expansion of the obstructed extra-cardiac conduit was done with a 48 mm long XXL PTFE-covered Optimus-CVS® under temporary cerebral embolic protection with a TriGUARD-3™ deflection filter device (Keystone Heart). There was no procedural complication and the 3 months clinical outcomes are good.


Asunto(s)
Dispositivos de Protección Embólica , Procedimiento de Fontan , Femenino , Humanos , Adulto Joven , Adulto , Cateterismo Cardíaco , Stents/efectos adversos , Procedimiento de Fontan/efectos adversos , Resultado del Tratamiento
8.
J Transl Med ; 21(1): 160, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36855159

RESUMEN

BACKGROUND: Recent studies have shown the implication of the ROBO-SLIT pathway in heart development. Within this study, we aimed to further assess the implication of the ROBO and SLIT genes mainly in bicuspid aortic valve (BAV) and other human congenital heart defects (CHD). METHODS: We have analyzed a cohort of singleton exome sequencing data comprising 40 adult BAV patients, 20 pediatric BAV patients generated by the Pediatric Cardiac Genomics Consortium, 10 pediatric cases with tetralogy of Fallot (ToF), and one case with coarctation of the aorta. A gene-centered analysis of data was performed. To further advance the interpretation of the variants, we intended to combine more than 5 prediction tools comprising the assessment of protein structure and stability. RESULTS: A total of 24 variants were identified. Only 4 adult BAV patients (10%) had missense variants in the ROBO and SLIT genes. In contrast, 19 pediatric cases carried variants in ROBO or SLIT genes (61%). Three BAV patients with a severe phenotype were digenic. Segregation analysis was possible for two BAV patients. For the homozygous ROBO4: p.(Arg776Cys) variant, family segregation was consistent with an autosomal recessive pattern of inheritance. The ROBO4: c.3001 + 3G > A variant segregates with the affected family members. Interestingly, these variants were also found in two unrelated patients with ToF highlighting that the same variant in the ROBO4 gene may underlie different cardiac phenotypes affecting the outflow tract development. CONCLUSION: Our results further reinforce the implication of the ROBO4 gene not only in BAV but also in ToF hence the importance of its inclusion in clinical genetic testing. The remaining ROBO and SLIT genes may be screened in patients with negative or inconclusive genetic tests.


Asunto(s)
Cardiopatías Congénitas , Tetralogía de Fallot , Adulto , Humanos , Niño , Cardiopatías Congénitas/genética , Pruebas Genéticas , Fenómica , Corazón
9.
Catheter Cardiovasc Interv ; 101(5): 863-869, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36861752

RESUMEN

We report the case of a 5.5-year-old patient (16 kg/105 cm) who presented with plastic bronchitis (PB) refractory to conservative treatment 3 months after completion of Fontan palliation. Bi-inguinal transnodal fluoroscopy-guided lymphangiogram confirmed the chylous leak originating from the thoracic duct (TD) into the chest and did not opacify any central lymphatic vessel for direct transabdominal puncture. Retrograde transfemoral approach was adopted to catheterize the TD and selectively embolize its caudal portion using microcoils and liquid embolic adhesive. Recurrence of symptoms after 2 months indicated a redo catheterization to occlude the TD entirely using the same technique. The procedure was successful and the patient was discharged after 2 days with sustained clinical improvement at 24 months postoperative. In the context of refractory PB, end-to-end transvenous retrograde embolization of the TD appears to be an interesting alternative to more complex interventions such as transabdominal puncture, decompression, or surgical ligation of the TD.


Asunto(s)
Bronquitis , Embolización Terapéutica , Procedimiento de Fontan , Humanos , Preescolar , Conducto Torácico/diagnóstico por imagen , Procedimiento de Fontan/efectos adversos , Resultado del Tratamiento , Bronquitis/diagnóstico por imagen , Bronquitis/etiología , Bronquitis/terapia , Embolización Terapéutica/métodos
10.
Europace ; 25(3): 961-968, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36735263

RESUMEN

AIMS: The implantable cardioverter defibrillator (ICD) has been increasingly used in children. Both epicardial and transvenous approaches are used, with controversy regarding the best option with no specific recommendations. We aimed to compare outcomes associated with epicardial vs. transvenous ICDs in children. METHODS AND RESULTS: Data were analysed from a retrospective study including all patients <18-year-old implanted with an ICD in a tertiary centre from 2003 to 2021. Outcomes were compared between epicardial and transvenous ICDs. A total of 122 children with an ICD (mean age 11.5 ± 3.8 years, 57.4% males) were enrolled, with 84 (64.1%) epicardial ICDs and 38 (29.0%) transvenous ICDs. Early (<30 days) ICD-related complications were reported in 17 (20.2%) patients with an epicardial ICD vs. 0 (0.0%) with a transvenous ICD (P = 0.002). Over a mean follow-up of 4.8 ± 4.0 years, 25 (29.8%) patients with an epicardial ICD and 9 (23.7%) patients with a transvenous ICD experienced at least one late ICD-related complication [hazard ratio (HR) 1.8, 95% confidence interval (CI) 0.8-4.0]. Implantable cardioverter defibrillator lead dysfunction occurred in 19 (22.6%) patients with an epicardial ICD vs. 3 (7.9%) with a transvenous ICD (HR 5.7, 95% CI 1.3-24.5) and was associated with a higher incidence of ICD-related reintervention (HR 3.0, 95% CI 1.3-7.0). After considering potential confounders, especially age and weight at implantation, this association was no longer significant (P = 0.112). The freedom from ICD lead dysfunction was greater in patients with pleural coils than in those with epicardial coils (HR 0.38, 95% CI 0.15-0.96). CONCLUSION: In children, after a consideration of patient characteristics at implantation, the burden of complications and ICD lead dysfunction appears to be similar in patients with epicardial and transvenous devices. Pleural coils seem to be associated with better outcomes than epicardial coils in this population. CLINICAL TRIAL REGISTRATION: NCT05349162.


Asunto(s)
Desfibriladores Implantables , Adolescente , Niño , Femenino , Humanos , Masculino , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
11.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37695311

RESUMEN

AIMS: The incidence of atrial tachyarrhythmias is high in patients with atrioventricular septal defect (AVSD). No specific data on catheter ablation have been reported so far in this population. We aimed to describe the main mechanisms of atrial tachyarrhythmias in patients with AVSD and to analyse outcomes after catheter ablation. METHODS AND RESULTS: This observational multi-centric cohort study enrolled all patients with AVSD referred for catheter ablation of an atrial tachyarrhythmia at six tertiary centres from 2004 to 2022. The mechanisms of the different tachyarrhythmias targeted were described and outcomes were analysed. Overall, 56 patients (38.1 ± 17.4 years, 55.4% females) were included. A total of 87 atrial tachyarrhythmias were targeted (mean number of 1.6 per patient). Regarding main circuits involved, a cavo-annular isthmus-dependent intra-atrial re-entrant tachycardia (IART) was observed in 41 (73.2%) patients and an IART involving the right lateral atriotomy in 10 (17.9%) patients. Other tachyarrhythmias with heterogeneous circuits were observed in 13 (23.2%) patients including 11 left-sided and 4 right-sided tachyarrhythmias. Overall, an acute success was achieved in 54 (96.4%) patients, and no complication was reported. During a mean follow-up of 2.8 ± 3.8 years, 22 (39.3%) patients had at least one recurrence. Freedom from atrial tachyarrhythmia recurrences was 77.5% at 1 year. Among 15 (26.8%) patients who underwent repeated ablation procedures, heterogeneous circuits including bi-atrial and left-sided tachyarrhythmias were more frequent. CONCLUSION: In patients with AVSD, most circuits involve the cavo-annular isthmus, but complex mechanisms are frequently encountered in patients with repeated procedures. The acute success rate is excellent, although recurrences remain common during follow-up.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios de Cohortes , Taquicardia/diagnóstico , Taquicardia/cirugía , Ablación por Catéter/efectos adversos , Recurrencia
12.
Eur J Epidemiol ; 38(7): 821-834, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37191831

RESUMEN

Pediatric patients with congenital heart disease (CHD) often undergo low dose ionizing radiation (LDIR) from cardiac catheterization (CC) for the diagnosis and/or treatment of their disease. Although radiation doses from a single CC are usually low, less is known about the long-term radiation associated cancer risks. We aimed to assess the risk of lympho-hematopoietic malignancies in pediatric CHD patients diagnosed or treated with CC. A French cohort of 17,104 children free of cancer who had undergone a first CC from 01/01/2000 to 31/12/2013, before the age of 16 was set up. The follow-up started at the date of the first recorded CC until the exit date, i.e., the date of death, the date of first cancer diagnosis, the date of the 18th birthday, or the 31/12/2015, whichever occurred first. Poisson regression was used to estimate the LDIR associated cancer risk. The median follow-up was 5.9 years, with 110,335 person-years. There were 22,227 CC procedures, yielding an individual active bone marrow (ABM) mean cumulative dose of 3.0 milligray (mGy). Thirty-eight incident lympho-hematopoietic malignancies were observed. When adjusting for attained age, gender and predisposing factors to cancer status, no increased risk was observed for lympho-hematopoietic malignancies RR/mGy = 1.00 (95% CI: 0.88; 1.10). In summary, the risk of lympho-hematopoietic malignancies and lymphoma was not associated to LDIR in pediatric patients with CHD who undergo CC. Further epidemiological studies with greater statistical power are needed to improve the assessment of the dose-risk relationship.


Asunto(s)
Cardiopatías Congénitas , Neoplasias Hematológicas , Neoplasias Inducidas por Radiación , Humanos , Niño , Factores de Riesgo , Neoplasias Inducidas por Radiación/epidemiología , Neoplasias Inducidas por Radiación/etiología , Radiación Ionizante , Neoplasias Hematológicas/epidemiología , Neoplasias Hematológicas/complicaciones , Cateterismo Cardíaco/efectos adversos , Dosis de Radiación
13.
Cardiol Young ; 33(9): 1726-1729, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36918290

RESUMEN

In neonatal Ebstein's anomaly of the tricuspid valve, prolonged ductal patency in patients without anatomic pulmonary valve atresia can be deleterious. Circular shunts may develop in patients with different degrees of pulmonary and tricuspid insufficiency. Closure of the arterial duct may result in haemodynamic improvement in particular scenarios. The transcatheter approach is a valuable closure alternative despite some technical difficulties in large-sized arterial ducts and low birth weight neonates. Herein, we report on two consecutive term newborns with Ebstein's anomaly and large arterial ducts in whom mechanical stimulus of the arterial duct during failed attempts of transcatheter closure led after two days to definitive closure followed by good clinical outcomes.


Asunto(s)
Conducto Arterial , Anomalía de Ebstein , Atresia Pulmonar , Insuficiencia de la Válvula Tricúspide , Humanos , Recién Nacido , Anomalía de Ebstein/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía
14.
Cardiol Young ; 33(12): 2597-2603, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37073828

RESUMEN

BACKGROUND: Low-profile stent implantation remains a rescue treatment for aortic coarctation and branch pulmonary arteries stenosis in small children. Stent re-expansion to cope with vascular growth remains problematic. OBJECTIVES: To evaluate ex vivo feasibility and mechanical behaviour of over-dilating BeSmooth peripheral stents (Bentley InnoMed, Germany). METHODS: Three BeSmooth peripheral stents in diameters of 7, 8, and 10 mm were dilated to nominal pressure and then 13 atm. BeSmooth Ø7 × 23 mm was sequentially post-dilated using 12, 14, and 16 mm high-pressure balloons. BeSmooth Ø10 × 57 mm was post-dilated with a 14 mm balloon and then with a 48 mm bare-metal Optimus XXL stent hand-mounted on a 14 mm balloon (stent-in-stent). BeSmooth Ø8 × 57 mm was directly post-dilated with a 48 mm bare-metal Optimus XXL stent hand-mounted on a 16 mm balloon (stent-in-stent). The stents' diameter and length were measured. Digital inflation pressure was noted. Balloon rupture and stent fracture patterns were closely evaluated. RESULTS: At 20atm pressure, BeSmooth Ø7 × 23 mm shortened to 2 mm forming a 12 mm diameter solid ring circle and the woven balloon ruptured radially. At 10 atm pressure, BeSmooth Ø10 × 57 mm fractured longitudinally in various dispatched breaking points at a diameter of 13 mm without shortening and ruptured the balloon with multiple pinholes. At 10 atm pressure, BeSmooth Ø8 × 57 mm fractured centrally at three different points at a diameter of 11.5 mm without shortening and the balloon broke radially in half. CONCLUSIONS: In our benchmark tests, extreme shortening, severe balloon rupture, or unpredictable stent fracture patterns at small balloon diameters limits safe post-dilation of BeSmooth stents beyond 13 mm. BeSmooth stents are not ideal candidates for off-label stent interventions in smaller patients.


Asunto(s)
Angioplastia de Balón , Niño , Adulto , Humanos , Dilatación , Diseño de Prótesis , Stents , Estrés Mecánico , Resultado del Tratamiento
15.
Eur Respir J ; 60(6)2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35618278

RESUMEN

BACKGROUND: The phenotype of pulmonary arterial hypertension (PAH) patients carrying SOX17 pathogenic variants remains mostly unknown. METHODS: We report the genetic analysis findings, characteristics and outcomes of patients with heritable PAH carrying SOX17 variants from the French Pulmonary Hypertension Network. RESULTS: 20 patients and eight unaffected relatives were identified. The median (range) age at diagnosis was 17 (2-53) years, with a female:male ratio of 1.5. At diagnosis, most of the patients (74%) were in New York Heart Association Functional Class III or IV with severe haemodynamic compromise, including a median pulmonary vascular resistance of 14.0 (4.2-31.5) WU. An associated congenital heart disease (CHD) was found in seven PAH patients (35%). Patients with CHD-associated PAH were significantly younger at diagnosis than PAH patients without CHD. Four patients (20%) suffered from recurrent haemoptysis requiring repeated arterial embolisations. 13 out of 16 patients (81%) for whom imaging was available displayed chest computed tomography abnormalities, including dilated, tortuous pulmonary vessels, ground-glass opacities as well as anomalies of the bronchial and nonbronchial arteries. After a median (range) follow-up of 47 (1-591) months, 10 patients underwent lung transplantation and one patient benefited from a heart-lung transplantation due to associated CHD. Histopathological analysis of lung explants showed a congested lung architecture with severe pulmonary arterial remodelling, subpleural vessel dilation and numerous haemorrhagic foci. CONCLUSIONS: PAH due to SOX17 pathogenic variants is a severe phenotype, frequently associated with CHD, haemoptysis and radiological abnormalities. Pathological assessment reveals severe pulmonary arterial remodelling and malformations affecting pulmonary vessels and thoracic systemic arteries.


Asunto(s)
Cardiopatías Congénitas , Hipertensión Pulmonar , Hipertensión Arterial Pulmonar , Masculino , Femenino , Humanos , Hipertensión Arterial Pulmonar/genética , Hipertensión Arterial Pulmonar/complicaciones , Hemoptisis , Remodelación Vascular/genética , Hipertensión Pulmonar Primaria Familiar/genética , Cardiopatías Congénitas/complicaciones , Fenotipo , Factores de Transcripción SOXF/genética
16.
J Pediatr ; 244: 148-153.e5, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35033563

RESUMEN

OBJECTIVES: To identify subgroups with a congenital heart defect (CHD) at risk of health-related quality of life (QoL) impairment at 8 years of age according to their medical and surgical management. STUDY DESIGN: From a prospective population-based cohort study, 598 patients with CHD were subdivided according to their medical and surgical management: (1) CHD followed-up in an outpatient clinic, (2) complete repair before age 3 years, (3) complete repair after age 3 years, (4) palliative repair, or (5) CHD with spontaneous resolution (reference subgroup). Self-reported QoL and parent-reported QoL were measured using the Pediatric Quality of Life Inventory version 4.0 (score range, 0-100) at age 8 years. Multivariable regression analysis and Cohen effect size were used to compare outcomes across the CHD groups. RESULTS: Self-reported and parent-reported QoL scores for the palliative repair subgroup were lower (ß = -2.1 [95% CI, -3.9 to -0.2] and ß = -16.0 [95% CI, -22.4 to -9.5], respectively), with a large effect size (δ = -0.9 [95% CI, -1.4 to -0.4] and δ = -1.3 [95% CI, -1.8 to -0.7], respectively). Parent-reported QoL scores for the complete repair after age 3 years subgroup were lower (ß = -9.2; 95% CI, -15.0 to -3.5), with a large effect size (δ = -0.9; 95% CI, -1.4 to -0.5). Self-reported QoL scores for the complete repair before age 3 years subgroup was lower (ß = -1.3; 95% CI, -1.9 to -0.6), with a small effect size (δ = -0.4; 95% CI, -0.6 to -0.2). CONCLUSIONS: The QoL of children with CHD who experienced a hospital intervention is reduced at age 8 years. Patient age at the last cardiac intervention might influence QoL at 8 years.


Asunto(s)
Cardiopatías Congénitas , Calidad de Vida , Niño , Preescolar , Estudios de Cohortes , Estudios Transversales , Cardiopatías Congénitas/cirugía , Humanos , Estudios Prospectivos
17.
Catheter Cardiovasc Interv ; 99(5): 1558-1562, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35192742

RESUMEN

We report the first use of a single 100-mm long custom-made version of the Optimus-CVS® balloon-expandable PTFE-covered XXL (15-Zig) stent (AndraTec, GmbH) to eliminate sinus venosus defect left-to-right shunt and redirect anomalous right pulmonary veins blood flow through a new walled channel to the left atrium. Anatomical feasibility and strategy decision were guided by ex-vivo procedure simulation on the patient-specific 3D printed heart model and in-vivo balloon interrogation. Modified procedural and implantation techniques are detailed. Immediate and one-month follow-up showed excellent outcomes.


Asunto(s)
Cardiopatías Congénitas , Defectos del Tabique Interatrial , Venas Pulmonares , Malformaciones Vasculares , Drenaje , Humanos , Venas Pulmonares/anomalías , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Stents , Resultado del Tratamiento
18.
Br J Clin Pharmacol ; 88(12): 5369-5377, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35816412

RESUMEN

The population pharmacokinetics of amiodarone and its active metabolite, N-desethylamiodarone (DEA) were investigated in paediatric patients with arrhythmias, mainly supraventricular tachycardias. A total of 55 patients from the Department of Pediatric Intensive Care and Pediatric Cardiology at Necker-Enfants malades Hospital (Paris, France) provided 72 concentrations for both amiodarone and DEA following repeated oral or intravenous administration. Blood samples drawn for biological analyses were used for drug concentrations. Plasma amiodarone concentrations were measured by a liquid chromatography method coupled with mass spectrometry and the data were modelled using the software Monolix 2019R2. Parent pharmacokinetics was described with a 2-compartment open model and the metabolite formation was connected to the central parent compartment. Parameter estimates scaled allometrically on bodyweight (normalized to 70 kg) were, respectively (% relative standard errors, RSEs), 6.32 (31%) and 7.14 L/h (26%) for elimination (CL) and intercompartmental clearances and 167 (31%) and 3930 (32%) L for V1 and V2 . Oral bioavailability was 0.362 (21.5%). The clearance between subject variability (ω, square root of the variance) was 0.462 (RSE 21%). The proportional residual variabilities were respectively 0.453 (RSE 13%) and 0.423 (RSE 12%) for amiodarone and DEA respectively. The terminal half-lives were 34 and 14.5 days for amiodarone and DEA, respectively. A dosage schedule was established for 3 weight bands in 2 time periods. The high pharmacokinetic variability suggests that therapeutic drug monitoring might be useful to improve individual efficacy and safety.


Asunto(s)
Amiodarona , Humanos , Niño , Administración Oral , Amiodarona/efectos adversos , Disponibilidad Biológica , Cromatografía Liquida
19.
Heart Vessels ; 37(7): 1271-1282, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35088203

RESUMEN

This study aimed at evaluating our experience with Micro Vascular Plug (MVP) for embolization of vascular abnormalities in children with congenital heart diseases (CHDs). MVP is one of the most recent additions to the armamentarium for peripheral embolization. Data on its use in congenital cardiology are scarce. Medical records of children with CHDs who had embolizations with MVPs between April 2015 and September 2020 were reviewed. Immediate and follow-up data were assessed. A total of 153 patients underwent 172 procedures during which 240 embolizations using 259 MVPs were attempted. Median age and weight were 34.9 months (IQR, 4-75 months) and 12.5 kg (IQR, 4.8-19.4 kg), respectively. Targets were abnormal systemic arteries (n = 163), patent arterial ducts (n = 26), venous (n = 45), and coronary-cameral fistulas (n = 6). Median vessel diameter was 3.3 mm (IQR, 2.5-4 mm). Veins were larger than arteries (2.3 mm > 2.1 mm, p < 0.01). MVPs were implanted in narrower diameters compared to manufacturer's recommendations. Compared to veins, solitary implanted MVPs in arteries were additionally oversized at 12.4%, 5.1%, and 7.9% for MVP-3Q, 5Q, and 7Q, respectively. Additional occlusion material (16.7%) and 2 MVPs (5.8%) were needed at the same site for complete closure. Implantation and procedure success rates were 99.2% and 96.7%, respectively. Five complications were treated percutaneously (n = 4) and surgically (n = 1). Efficacy of vascular embolization using MVPs was demonstrated in the largest cohort of children with CHDs and a variety of clinical settings. Immediate and stable closure is obtained with a single device in most cases. Detailed device selection chart according to vessel type and diameter is proposed to achieve intended outcomes.


Asunto(s)
Conducto Arterioso Permeable , Embolización Terapéutica , Cardiopatías Congénitas , Niño , Conducto Arterioso Permeable/terapia , Embolización Terapéutica/efectos adversos , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
20.
Eur Heart J ; 42(20): 1976-1984, 2021 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-33748842

RESUMEN

AIMS: To estimate the effect of prophylactic angiotensin-converting enzyme inhibitors (ACEi) on survival in Duchenne muscular dystrophy (DMD). METHODS AND RESULTS: We analysed the data from the French multicentre DMD Heart Registry (ClinicalTrials.gov: NCT03443115). We estimated the association between the prophylactic prescription of ACEi and event-free survival in 668 patients aged 8 to 13 years, with normal left ventricular function, using (i) a Cox model with intervention as a time-dependent covariate, (ii) a propensity-based analysis comparing ACEi treatment vs. no treatment, and (iii) a set of sensitivity analyses. The study outcomes were overall survival and hospitalizations for heart failure (HF) or acute respiratory failure. Among the 668 patients included in the DMD Heart Registry, 576 (mean age 6.1 ± 2.8 years) were eligible for this study, of whom 390 were treated with ACEi prophylactically. Death occurred in 53 patients (13.5%) who were and 60 patients (32.3%) who were not treated prophylactically with ACEi, respectively. In a Cox model with intervention as a time-dependent variable, the hazard ratio (HR) associated with ACEi treatment was 0.49 [95% confidence interval (CI) 0.34-0.72] and 0.47 (95% CI 0.31-0.17) for overall mortality after adjustment for baseline variables. In the propensity-based analysis, 278 patients were included in the treatment group and 834 in the control group, with 18.5% and 30.4% 12-year estimated probability of death, respectively. ACEi were associated with a lower risk of death (HR 0.39; 95% CI 0.17-0.92) and hospitalization for HF (HR 0.16; 95% CI 0.04-0.62). All other sensitivity analyses yielded similar results. CONCLUSION: Prophylactic ACEi treatment in DMD was associated with a significantly higher overall survival and lower rates of hospitalization for HF.


Asunto(s)
Insuficiencia Cardíaca , Distrofia Muscular de Duchenne , Antagonistas de Receptores de Angiotensina/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Niño , Preescolar , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/prevención & control , Humanos , Distrofia Muscular de Duchenne/tratamiento farmacológico , Sistema de Registros , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA