RESUMEN
BACKGROUND: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known. METHODS: We conducted an event-driven, double-blind, double-dummy, randomized trial involving patients 65 years of age or older who had AHREs lasting for at least 6 minutes and who had at least one additional risk factor for stroke. Patients were randomly assigned in a 1:1 ratio to receive edoxaban or placebo. The primary efficacy outcome was a composite of cardiovascular death, stroke, or systemic embolism, evaluated in a time-to-event analysis. The safety outcome was a composite of death from any cause or major bleeding. RESULTS: The analysis population consisted of 2536 patients (1270 in the edoxaban group and 1266 in the placebo group). The mean age was 78 years, 37.4% were women, and the median duration of AHREs was 2.8 hours. The trial was terminated early, at a median follow-up of 21 months, on the basis of safety concerns and the results of an independent, informal assessment of futility for the efficacy of edoxaban; at termination, the planned enrollment had been completed. A primary efficacy outcome event occurred in 83 patients (3.2% per patient-year) in the edoxaban group and in 101 patients (4.0% per patient-year) in the placebo group (hazard ratio, 0.81; 95% confidence interval [CI], 0.60 to 1.08; P = 0.15). The incidence of stroke was approximately 1% per patient-year in both groups. A safety outcome event occurred in 149 patients (5.9% per patient-year) in the edoxaban group and in 114 patients (4.5% per patient-year) in the placebo group (hazard ratio, 1.31; 95% CI, 1.02 to 1.67; P = 0.03). ECG-diagnosed atrial fibrillation developed in 462 of 2536 patients (18.2% total, 8.7% per patient-year). CONCLUSIONS: Among patients with AHREs detected by implantable devices, anticoagulation with edoxaban did not significantly reduce the incidence of a composite of cardiovascular death, stroke, or systemic embolism as compared with placebo, but it led to a higher incidence of a composite of death or major bleeding. The incidence of stroke was low in both groups. (Funded by the German Center for Cardiovascular Research and others; NOAH-AFNET 6 ClinicalTrials.gov number, NCT02618577; ISRCTN number, ISRCTN17309850.).
Asunto(s)
Anticoagulantes , Arritmias Cardíacas , Embolia , Inhibidores del Factor Xa , Anciano , Femenino , Humanos , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Embolia/tratamiento farmacológico , Embolia/etiología , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Hemorragia/inducido químicamente , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Electrodos Implantados , Método Doble Ciego , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Factores de RiesgoRESUMEN
BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24â h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24â h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24â h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.
Asunto(s)
Fibrilación Atrial , Piridinas , Accidente Cerebrovascular , Tiazoles , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/diagnóstico , Atrios Cardíacos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/diagnóstico , Anticoagulantes/uso terapéuticoRESUMEN
BACKGROUND: Research suggests NT-proBNP (N-terminal pro-B-type natriuretic peptide) to be a strong predictor of incident atrial fibrillation (AF) and stroke. However, its utility in AF screening remains unknown. The aim of this study was to investigate NT-proBNP as a potential marker for screening efficacy with respect to AF yield and stroke prevention. METHODS: In the LOOP Study (Atrial Fibrillation Detected by Continuous ECG Monitoring Using Implantable Loop Recorder to Prevent Stroke in High-Risk Individuals), 6004 AF-naïve individuals at least 70 years old and with additional stroke risk factors were randomized 1:3 to either screening with an implantable loop recorder (ILR) and initiation of anticoagulation upon detection of AF episodes lasting ≥6 minutes or usual care (control). This post hoc analysis included study participants with available NT-proBNP measurement at baseline. RESULTS: A total of 5819 participants (96.9% of the trial population) were included. The mean age was 74.7 years (SD, 4.1 years) and 47.5% were female. The median NT-proBNP level was 15 pmol/L (interquartile range, 9-28 pmol/L) corresponding to 125 pg/mL (interquartile range, 76-233 pg/mL). NT-proBNP above median was associated with an increased risk of AF diagnosis both in the ILR group (hazard ratio, 1.84 [95% CI, 1.51-2.25]) and the control group (hazard ratio, 2.79 [95% CI, 2.30-3.40]). Participants with NT-proBNP above the median were also at higher risk of clinical events compared with those having lower levels (hazard ratio, 1.21 [95% CI, 0.96-1.54] for stroke or systemic embolism [SE], 1.60 [95% CI, 1.32-1.95] for stroke/SE/cardiovascular death, and 1.91 [95% CI, 1.61-2.26] for all-cause death). Compared with usual care, ILR screening was associated with significant reductions in stroke/SE and stroke/SE/cardiovascular death among participants with NT-proBNP above median (hazard ratio, 0.60 [95% CI, 0.40-0.90] and 0.70 [95% CI, 0.53-0.94], respectively) but not among those with lower levels (Pinteraction=0.029 for stroke/SE and 0.045 for stroke/SE/cardiovascular death). No risk reduction in all-cause death was observed in either NT-proBNP subgroup for ILR versus control (Pinteraction=0.68). Analyzing NT-proBNP as a continuous variable yielded similar findings. CONCLUSIONS: In an older population with additional stroke risk factors, ILR screening for AF was associated with a significant reduction in stroke risk among individuals with higher NT-proBNP levels but not among those with lower levels. These findings should be considered hypothesis generating and warrant further study before clinical implementation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02036450.
Asunto(s)
Fibrilación Atrial , Embolia , Accidente Cerebrovascular , Anciano , Femenino , Humanos , Masculino , Fibrilación Atrial/diagnóstico , Biomarcadores , Embolia/complicaciones , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Accidente Cerebrovascular/prevención & controlRESUMEN
Contemporary management of atrial fibrillation (AF) has become increasingly complex. Therefore, strong efforts have been made during the past decade to develop models for structured, integrated care for patients with AF. These have also been incorporated in international guidelines for the management of patients with AF. However, implementation of integrated care approaches in daily clinical practice is scarce and far from optimal, and it may require a re-thinking of the structure of the healthcare system. The reasons for the poor implementation are many, from limited time and economic resources to deficits in postgraduate education of healthcare professionals, lack of involvement of patients in how integrated care should be designed, and fragmentation of the healthcare system. Moreover, patients' psychological challenges, which not only impact patients' adherence to treatment but, if untreated, increase their risk of morbidity, mortality, and poor quality of life, are not given sufficient attention. It is time to start a necessary discussion of what integrated care should be, what it should contain, and what is necessary to implement it in daily clinical practice.
Asunto(s)
Fibrilación Atrial , Prestación Integrada de Atención de Salud , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Calidad de VidaRESUMEN
Subclinical, device-detected atrial fibrillation (AF) is frequently recorded by pacemakers and other implanted cardiac rhythm devices. Patients with device-detected AF have an elevated risk of stroke, but a lower risk of stroke than similar patients with clinical AF captured with surface electrocardiogram. Two randomized clinical trials (NOAH-AFNET 6 and ARTESiA) have tested a direct oral anticoagulant (DOAC) against aspirin or placebo. A study-level meta-analysis of the two trials found that treatment with a DOAC resulted in a 32% reduction in ischaemic stroke and a 62% increase in major bleeding; the results of the two trials were consistent. The annualized rate of stroke in the control arms was â¼1%. Several factors point towards overall net benefit from DOAC treatment for patients with device-detected AF. Strokes in ARTESiA were frequently fatal or disabling and bleeds were rarely lethal. The higher absolute rates of major bleeding compared with ischaemic stroke while on treatment with a DOAC in the two trials are consistent with the ratio of bleeds to strokes seen in the pivotal DOAC vs. warfarin trials in patients with clinical AF. Prior research has concluded that patients place a higher emphasis on stroke prevention than on bleeding. Further research is needed to identify the characteristics that will help identify patients with device-detected AF who will receive the greatest benefit from DOAC treatment.
RESUMEN
BACKGROUND: DANISH (The Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators [ICDs] in Patients With Nonischemic Systolic Heart Failure on Mortality) found that primary-prevention ICD implantation was not associated with an overall survival benefit in patients with nonischemic systolic heart failure during a median follow-up of 5.6 years, although there was a beneficial effect on all-cause mortality in patients ≤70 years. This study presents an additional 4 years of follow-up data from DANISH. METHODS: In DANISH, 556 patients with nonischemic systolic heart failure were randomized to receive an ICD and 560 to receive usual clinical care and followed until June 30, 2016. In this long-term follow-up study, patients were followed until May 18, 2020. Analyses were conducted for the overall population and according to age (≤70 and >70 years). RESULTS: During a median follow-up of 9.5 years (25th-75th percentile, 7.9-10.9 years), 208/556 patients (37%) in the ICD group and 226/560 patients (40%) in the control group died. Compared with the control group, the ICD group did not have significantly lower all-cause mortality (hazard ratio [HR] 0.89, [95% CI, 0.74-1.08]; P = 0.24). In patients ≤70 years (n = 829), all-cause mortality was lower in the ICD group than the control group (117/389 [30%] versus 158/440 [36%]; HR, 0.78 [95% CI, 0.61-0.99]; P = 0.04), whereas in patients >70 years (n = 287), all-cause mortality was not significantly different between the ICD and control group (91/167 [54%] versus 68/120 [57%]; HR, 0.92 [95% CI, 0.67-1.28]; P = 0.75). Cardiovascular death showed similar trends (overall, 147/556 [26%] versus 164/560 [29%]; HR, 0.87 [95% CI, 0.70-1.09]; P = 0.20; ≤70 years, 87/389 [22%] versus 122/440 [28%]; HR, 0.75 [95% CI, 0.57-0.98]; P = 0.04; >70 years, 60/167 [36%] versus 42/120 [35%]; HR, 0.97 [95% CI, 0.65-1.45]; P = 0.91). The ICD group had a significantly lower incidence of sudden cardiovascular death in the overall population (35/556 [6%] versus 57/560 [10%]; HR, 0.60 [95% CI, 0.40-0.92]; P = 0.02) and in patients ≤70 years (19/389 [5%] versus 49/440 [11%]; HR, 0.42 [95% CI, 0.24-0.71]; P = 0.0008), but not in patients >70 years (16/167 [10%] versus 8/120 [7%]; HR, 1.34 [95% CI, 0.56-3.19]; P = 0.39). CONCLUSIONS: During a median follow-up of 9.5 years, ICD implantation did not provide an overall survival benefit in patients with nonischemic systolic heart failure. In patients ≤70 years, ICD implantation was associated with a lower incidence of all-cause mortality, cardiovascular death, and sudden cardiovascular death. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00542945.
Asunto(s)
Desfibriladores Implantables/normas , Insuficiencia Cardíaca Sistólica/epidemiología , Insuficiencia Cardíaca Sistólica/mortalidad , Anciano , Dinamarca , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Análisis de SupervivenciaRESUMEN
BACKGROUND: Identification of patients with nonischemic cardiomyopathy who may benefit from prophylactic implantation of a cardioverter-defibrillator. We hypothesized that periodic repolarization dynamics (PRD), a marker of repolarization instability associated with sympathetic activity, could be used to identify patients who will benefit from prophylactic implantable cardioverter defibrillator (ICD) implantation. METHODS: We performed a post hoc analysis of DANISH (Danish ICD Study in Patients With Dilated Cardiomyopathy), in which patients with nonischemic cardiomyopathy, left ventricular ejection fraction (LVEF) ≤35%, and elevated NT-proBNP (N-terminal probrain natriuretic peptides) were randomized to ICD implantation or control group. Patients were included in the PRD substudy if they had a 24-hour Holter monitor recording at baseline with technically acceptable ECG signals during the night hours (00:00-06:00). PRD was assessed using wavelet analysis according to previously validated methods. The primary end point was all-cause mortality. Cox regression models were adjusted for age, sex, NT-proBNP, estimated glomerular filtration rate, LVEF, atrial fibrillation, ventricular pacing, diabetes, cardiac resynchronization therapy, and mean heart rate. We proposed PRD ≥10 deg2 as an exploratory cut-off value for ICD implantation. RESULTS: A total of 748 of the 1116 patients in DANISH qualified for the PRD substudy. During a mean follow-up period of 5.1±2.0 years, 82 of 385 patients died in the ICD group and 85 of 363 patients died in the control group (P=0.40). In Cox regression analysis, PRD was independently associated with mortality (hazard ratio [HR], 1.28 [95% CI, 1.09-1.50] per SD increase; P=0.003). PRD was significantly associated with mortality in the control group (HR, 1.51 [95% CI, 1.25-1.81]; P<0.001) but not in the ICD group (HR, 1.04 [95% CI, 0.83-1.54]; P=0.71). There was a significant interaction between PRD and the effect of ICD implantation on mortality (P=0.008), with patients with higher PRD having greater benefit in terms of mortality reduction. ICD implantation was associated with an absolute mortality reduction of 17.5% in the 280 patients with PRD ≥10 deg2 (HR, 0.54 [95% CI, 0.34-0.84]; P=0.006; number needed to treat=6), but not in the 468 patients with PRD <10 deg2 (HR, 1.17 [95% CI, 0.77-1.78]; P=0.46; P for interaction=0.01). CONCLUSIONS: Increased PRD identified patients with nonischemic cardiomyopathy in whom prophylactic ICD implantation led to significant mortality reduction.
Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Desfibriladores Implantables , Cardiomiopatías/diagnóstico , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Dinamarca/epidemiología , Humanos , Volumen Sistólico , Función Ventricular IzquierdaRESUMEN
The technological evolution and widespread availability of wearables and handheld ECG devices capable of screening for atrial fibrillation (AF), and their promotion directly to consumers, has focused attention of health care professionals and patient organizations on consumer-led AF screening. In this Frontiers review, members of the AF-SCREEN International Collaboration provide a critical appraisal of this rapidly evolving field to increase awareness of the complexities and uncertainties surrounding consumer-led AF screening. Although there are numerous commercially available devices directly marketed to consumers for AF monitoring and identification of unrecognized AF, health care professional-led randomized controlled studies using multiple ECG recordings or continuous ECG monitoring to detect AF have failed to demonstrate a significant reduction in stroke. Although it remains uncertain if consumer-led AF screening reduces stroke, it could increase early diagnosis of AF and facilitate an integrated approach, including appropriate anticoagulation, rate or rhythm management, and risk factor modification to reduce complications. Companies marketing AF screening devices should report the accuracy and performance of their products in high- and low-risk populations and avoid claims about clinical outcomes unless improvement is demonstrated in randomized clinical trials. Generally, the diagnostic yield of AF screening increases with the number, duration, and temporal dispersion of screening sessions, but the prognostic importance may be less than for AF detected by single-time point screening, which is largely permanent, persistent, or high-burden paroxysmal AF. Consumer-initiated ECG recordings suggesting possible AF always require confirmation by a health care professional experienced in ECG reading, whereas suspicion of AF on the basis of photoplethysmography must be confirmed with an ECG. Consumer-led AF screening is unlikely to be cost-effective for stroke prevention in the predominantly young, early adopters of this technology. Studies in older people at higher stroke risk are required to demonstrate both effectiveness and cost-effectiveness. The direct interaction between companies and consumers creates new regulatory gaps in relation to data privacy and the registration of consumer apps and devices. Although several barriers for optimal use of consumer-led screening exist, results of large, ongoing trials, powered to detect clinical outcomes, are required before health care professionals should support widespread adoption of consumer-led AF screening.
Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Anciano , Electrocardiografía/métodos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Tamizaje Masivo/métodos , Factores de RiesgoRESUMEN
Growing evidence suggests a consistent association between atrial fibrillation (AF) and cognitive impairment and dementia that is independent of clinical stroke. This report from the AF-SCREEN International Collaboration summarizes the evidence linking AF to cognitive impairment and dementia. It provides guidance on the investigation and management of dementia in patients with AF on the basis of best available evidence. The document also addresses suspected pathophysiologic mechanisms and identifies knowledge gaps for future research. Whereas AF and dementia share numerous risk factors, the association appears to be independent of these variables. Nevertheless, the evidence remains inconclusive regarding a direct causal effect. Several pathophysiologic mechanisms have been proposed, some of which are potentially amenable to early intervention, including cerebral microinfarction, AF-related cerebral hypoperfusion, inflammation, microhemorrhage, brain atrophy, and systemic atherosclerotic vascular disease. The mitigating role of oral anticoagulation in specific subgroups (eg, low stroke risk, short duration or silent AF, after successful AF ablation, or atrial cardiopathy) and the effect of rhythm versus rate control strategies remain unknown. Likewise, screening for AF (in cognitively normal or cognitively impaired patients) and screening for cognitive impairment in patients with AF are debated. The pathophysiology of dementia and therapeutic strategies to reduce cognitive impairment warrant further investigation in individuals with AF. Cognition should be evaluated in future AF studies and integrated with patient-specific outcome priorities and patient preferences. Further large-scale prospective studies and randomized trials are needed to establish whether AF is a risk factor for cognitive impairment, to investigate strategies to prevent dementia, and to determine whether screening for unknown AF followed by targeted therapy might prevent or reduce cognitive impairment and dementia.
Asunto(s)
Fibrilación Atrial/fisiopatología , Demencia/fisiopatología , Humanos , Factores de RiesgoRESUMEN
BACKGROUND: Despite improvements in the management of atrial fibrillation, patients with this condition remain at increased risk for cardiovascular complications. It is unclear whether early rhythm-control therapy can reduce this risk. METHODS: In this international, investigator-initiated, parallel-group, open, blinded-outcome-assessment trial, we randomly assigned patients who had early atrial fibrillation (diagnosed ≤1 year before enrollment) and cardiovascular conditions to receive either early rhythm control or usual care. Early rhythm control included treatment with antiarrhythmic drugs or atrial fibrillation ablation after randomization. Usual care limited rhythm control to the management of atrial fibrillation-related symptoms. The first primary outcome was a composite of death from cardiovascular causes, stroke, or hospitalization with worsening of heart failure or acute coronary syndrome; the second primary outcome was the number of nights spent in the hospital per year. The primary safety outcome was a composite of death, stroke, or serious adverse events related to rhythm-control therapy. Secondary outcomes, including symptoms and left ventricular function, were also evaluated. RESULTS: In 135 centers, 2789 patients with early atrial fibrillation (median time since diagnosis, 36 days) underwent randomization. The trial was stopped for efficacy at the third interim analysis after a median of 5.1 years of follow-up per patient. A first-primary-outcome event occurred in 249 of the patients assigned to early rhythm control (3.9 per 100 person-years) and in 316 patients assigned to usual care (5.0 per 100 person-years) (hazard ratio, 0.79; 96% confidence interval, 0.66 to 0.94; P = 0.005). The mean (±SD) number of nights spent in the hospital did not differ significantly between the groups (5.8±21.9 and 5.1±15.5 days per year, respectively; P = 0.23). The percentage of patients with a primary safety outcome event did not differ significantly between the groups; serious adverse events related to rhythm-control therapy occurred in 4.9% of the patients assigned to early rhythm control and 1.4% of the patients assigned to usual care. Symptoms and left ventricular function at 2 years did not differ significantly between the groups. CONCLUSIONS: Early rhythm-control therapy was associated with a lower risk of adverse cardiovascular outcomes than usual care among patients with early atrial fibrillation and cardiovascular conditions. (Funded by the German Ministry of Education and Research and others; EAST-AFNET 4 ISRCTN number, ISRCTN04708680; ClinicalTrials.gov number, NCT01288352; EudraCT number, 2010-021258-20.).
Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Enfermedades Cardiovasculares/prevención & control , Ablación por Catéter , Síndrome Coronario Agudo/epidemiología , Anciano , Antiarrítmicos/efectos adversos , Fibrilación Atrial/complicaciones , Enfermedades Cardiovasculares/mortalidad , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/epidemiología , Hospitalización/estadística & datos numéricos , Humanos , Incidencia , Tiempo de Internación , Masculino , Riesgo , Prevención Secundaria , Método Simple Ciego , Función Ventricular Izquierda/efectos de los fármacosRESUMEN
AIMS: Insights into subclinical atrial fibrillation (AF) development are warranted to inform the strategies of screening and subsequent clinical management upon AF detection. Hence, this study sought to characterize the onset and progression of subclinical AF with respect to 12-lead electrocardiogram (ECG) parameters. METHODS AND RESULTS: We included AF-naïve individuals aged 70-90 years with additional stroke risk factors who underwent implantable loop recorder (ILR) monitoring in the LOOP Study. Using data from daily ILR recordings and the computerized analysis of baseline ECG, we studied empirically selected ECG parameters for AF detection (≥6â min), cumulative AF burden, long-lasting AF (≥24â h), and AF progression. Of 1370 individuals included, 419 (30.6%) developed AF during follow-up, with a mean cumulative AF burden of 1.5% [95% CI: 1.2-1.8]. Several P-wave-related and ventricular ECG parameters were associated with new-onset AF and with cumulative AF burden in AF patients. P-wave duration (PWD), P-wave terminal force in Lead V1, and interatrial block (IAB) further demonstrated significant associations with long-lasting AF. Among AF patients, we observed an overall reduction in cumulative AF burden over time (IRR 0.70 [95% CI: 0.51-0.96]), whereas IAB was related to an increased risk of progression to AF ≥24â h (HR 1.86 [95% CI: 1.02-3.39]). Further spline analysis also revealed longer PWD to be associated with this progression in AF duration. CONCLUSION: We identified several ECG parameters associated with new-onset subclinical AF detected by ILR. Especially PWD and IAB were robustly related to the onset and the burden of AF as well as progression over time.
Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Electrocardiografía/métodos , Accidente Cerebrovascular/prevención & control , Factores de Riesgo , Electrodos Implantados/efectos adversos , Bloqueo Interauricular , Electrocardiografía AmbulatoriaRESUMEN
Atrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences. The presence of AHRE increases the risk of stroke compared with patients without AHRE. Oral anticoagulation would have the potential to reduce the risk of stroke in patients with AHRE but is also associated with a rate of major bleeding of â¼2%/year. The stroke rate in patients with AHRE appears to be lower than the stroke rate in patients with atrial fibrillation. Wearables like smart-watches will increase the absolute number of patients in whom atrial arrhythmias are detected. It remains unclear whether anticoagulation is effective and, equally important, safe in patients with AHRE. Two randomized clinical trials, NOAH-AFNET6 and ARTESiA, are expected to report soon. They will provide much-needed information on the efficacy and safety of oral anticoagulation in patients with AHRE.
Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Factores de Riesgo , Anticoagulantes/uso terapéutico , Atrios Cardíacos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & controlRESUMEN
AIMS: Clinical practice guidelines restrict rhythm control therapy to patients with symptomatic atrial fibrillation (AF). The EAST-AFNET 4 trial demonstrated that early, systematic rhythm control improves clinical outcomes compared to symptom-directed rhythm control. METHODS AND RESULTS: This prespecified EAST-AFNET 4 analysis compared the effect of early rhythm control therapy in asymptomatic patients (EHRA score I) to symptomatic patients. Primary outcome was a composite of death from cardiovascular causes, stroke, or hospitalization with worsening of heart failure or acute coronary syndrome, analyzed in a time-to-event analysis. At baseline, 801/2633 (30.4%) patients were asymptomatic [mean age 71.3 years, 37.5% women, mean CHA2DS2-VASc score 3.4, 169/801 (21.1%) heart failure]. Asymptomatic patients randomized to early rhythm control (395/801) received similar rhythm control therapies compared to symptomatic patients [e.g. AF ablation at 24 months: 75/395 (19.0%) in asymptomatic; 176/910 (19.3%) symptomatic patients, P = 0.672]. Anticoagulation and treatment of concomitant cardiovascular conditions was not different between symptomatic and asymptomatic patients. The primary outcome occurred in 79/395 asymptomatic patients randomized to early rhythm control and in 97/406 patients randomized to usual care (hazard ratio 0.76, 95% confidence interval [0.6; 1.03]), almost identical to symptomatic patients. At 24 months follow-up, change in symptom status was not different between randomized groups (P = 0.19). CONCLUSION: The clinical benefit of early, systematic rhythm control was not different between asymptomatic and symptomatic patients in EAST-AFNET 4. These results call for a shared decision discussing the benefits of rhythm control therapy in all patients with recently diagnosed AF and concomitant cardiovascular conditions (EAST-AFNET 4; ISRCTN04708680; NCT01288352; EudraCT2010-021258-20).
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Prevención Secundaria , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & controlRESUMEN
AIMS: Gastrointestinal bleeding (GI-bleeding) is frequent in patients with atrial fibrillation (AF) treated with oral anticoagulation (OAC) therapy. We sought to investigate to what extent lower GI-bleeding represents the unmasking of an occult colorectal cancer. METHODS AND RESULTS: A total of 125 418 Danish AF patients initiating OAC therapy were identified using Danish administrative registers. Non-parametric estimation and semi-parametric absolute risk regression were used to estimate the absolute risks of colorectal cancer in patients with and without lower GI-bleeding. During a maximum of 3 years of follow-up, we identified 2576 patients with lower GI-bleeding of whom 140 patients were subsequently diagnosed with colorectal cancer within the first year of lower GI-bleeding. In all age groups, we observed high risks of colorectal cancer after lower GI-bleeding. The absolute 1-year risk ranged from 3.7% [95% confidence interval (CI) 2.2-6.2] to 8.1% (95% CI 6.1-10.6) in the age groups ≤65 and 76-80 years of age, respectively. When comparing patients with and without lower GI-bleeding, we found increased risk ratios of colorectal cancer across all age groups with a risk ratio of 24.2 (95% CI 14.5-40.4) and 12.3 (95% CI 7.9-19.0) for the youngest and oldest age group of ≤65 and >85 years, respectively. CONCLUSION: In anticoagulated AF patients, lower GI-bleeding conferred high absolute risks of incident colorectal cancer. Lower GI-bleeding should not be dismissed as a benign consequence of OAC therapy but always examined for a potential underlying malignant cause.
RESUMEN
BACKGROUND: Even on optimal therapy, many patients with heart failure and atrial fibrillation experience cardiovascular complications. Additional treatments are needed to reduce these events, especially in patients with heart failure and preserved left ventricular ejection fraction. METHODS: This prespecified subanalysis of the randomized EAST-AFNET4 trial (Early Treatment of Atrial Fibrillation for Stroke Prevention Trial) assessed the effect of systematic, early rhythm control therapy (ERC; using antiarrhythmic drugs or catheter ablation) compared with usual care (allowing rhythm control therapy to improve symptoms) on the 2 primary outcomes of the trial and on selected secondary outcomes in patients with heart failure, defined as heart failure symptoms New York Heart Association II to III or left ventricular ejection fraction [LVEF] <50%. RESULTS: This analysis included 798 patients (300 [37.6%] female, median age 71.0 [64.0, 76.0] years, 785 with known LVEF). The majority of patients (n=442) had heart failure and preserved LVEF (LVEF≥50%; mean LVEF 61±6.3%), the others had heart failure with midrange ejection fraction (n=211; LVEF 40%-49%; mean LVEF 44 ± 2.9%) or heart failure with reduced ejection fraction (n=132; LVEF<40%; mean LVEF 31±5.5%). Over the 5.1-year median follow-up, the composite primary outcome of cardiovascular death, stroke, or hospitalization for worsening of heart failure or for acute coronary syndrome occurred less often in patients randomly assigned to ERC (94/396; 5.7 per 100 patient-years) compared with patients randomly assigned to usual care (130/402; 7.9 per 100 patient-years; hazard ratio, 0.74 [0.56-0.97]; P=0.03), not altered by heart failure status (interaction P value=0.63). The primary safety outcome (death, stroke, or serious adverse events related to rhythm control therapy) occurred in 71 of 396 (17.9%) patients with heart failure randomly assigned to ERC and in 87 of 402 (21.6%) patients with heart failure randomly assigned to usual care (hazard ratio, 0.85 [0.62-1.17]; P=0.33). LVEF improved in both groups (LVEF change at 2 years: ERC 5.3±11.6%, usual care 4.9±11.6%, P=0.43). ERC also improved the composite outcome of death or hospitalization for worsening of heart failure. CONCLUSIONS: Rhythm control therapy conveys clinical benefit when initiated within 1 year of diagnosing atrial fibrillation in patients with signs or symptoms of heart failure. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01288352. URL: http://www.controlled-trials.com; Unique identifier: ISRCTN04708680. URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2010-021258-20.
Asunto(s)
Fibrilación Atrial/terapia , Insuficiencia Cardíaca/terapia , Prevención Secundaria , Disfunción Ventricular Izquierda/terapia , Adulto , Anciano , Anciano de 80 o más Años , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Accidente Cerebrovascular/terapia , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda/fisiologíaRESUMEN
BACKGROUND: It is unknown whether screening for atrial fibrillation and subsequent treatment with anticoagulants if atrial fibrillation is detected can prevent stroke. Continuous electrocardiographic monitoring using an implantable loop recorder (ILR) can facilitate detection of asymptomatic atrial fibrillation episodes. We aimed to investigate whether atrial fibrillation screening and use of anticoagulants can prevent stroke in individuals at high risk. METHODS: We did a randomised controlled trial in four centres in Denmark. We included individuals without atrial fibrillation, aged 70-90 years, with at least one additional stroke risk factor (ie, hypertension, diabetes, previous stroke, or heart failure). Participants were randomly assigned in a 1:3 ratio to ILR monitoring or usual care (control) via an online system in permuted blocks with block sizes of four or eight participants stratified according to centre. In the ILR group, anticoagulation was recommended if atrial fibrillation episodes lasted 6 min or longer. The primary outcome was time to first stroke or systemic arterial embolism. This study is registered with ClinicalTrials.gov, NCT02036450. FINDINGS: From Jan 31, 2014, to May 17, 2016, 6205 individuals were screened for inclusion, of whom 6004 were included and randomly assigned: 1501 (25·0%) to ILR monitoring and 4503 (75·0%) to usual care. Mean age was 74·7 years (SD 4·1), 2837 (47·3%) were women, and 5444 (90·7%) had hypertension. No participants were lost to follow-up. During a median follow-up of 64·5 months (IQR 59·3-69·8), atrial fibrillation was diagnosed in 1027 participants: 477 (31·8%) of 1501 in the ILR group versus 550 (12·2%) of 4503 in the control group (hazard ratio [HR] 3·17 [95% CI 2·81-3·59]; p<0·0001). Oral anticoagulation was initiated in 1036 participants: 445 (29·7%) in the ILR group versus 591 (13·1%) in the control group (HR 2·72 [95% CI 2·41-3·08]; p<0·0001), and the primary outcome occurred in 318 participants (315 stroke, three systemic arterial embolism): 67 (4·5%) in the ILR group versus 251 (5·6%) in the control group (HR 0·80 [95% CI 0·61-1·05]; p=0·11). Major bleeding occurred in 221 participants: 65 (4·3%) in the ILR group versus 156 (3·5%) in the control group (HR 1·26 [95% CI 0·95-1·69]; p=0·11). INTERPRETATION: In individuals with stroke risk factors, ILR screening resulted in a three-times increase in atrial fibrillation detection and anticoagulation initiation but no significant reduction in the risk of stroke or systemic arterial embolism. These findings might imply that not all atrial fibrillation is worth screening for, and not all screen-detected atrial fibrillation merits anticoagulation. FUNDING: Innovation Fund Denmark, The Research Foundation for the Capital Region of Denmark, The Danish Heart Foundation, Aalborg University Talent Management Program, Arvid Nilssons Fond, Skibsreder Per Henriksen, R og Hustrus Fond, The AFFECT-EU Consortium (EU Horizon 2020), Læge Sophus Carl Emil Friis og hustru Olga Doris Friis' Legat, and Medtronic.
Asunto(s)
Fibrilación Atrial/diagnóstico , Isquemia Encefálica/prevención & control , Electrocardiografía Ambulatoria/instrumentación , Accidente Cerebrovascular/prevención & control , Anciano , Anticoagulantes/uso terapéutico , Dinamarca , Femenino , Humanos , Masculino , Factores de RiesgoRESUMEN
BACKGROUND: Atrial remodeling is associated with future atrial fibrillation (AF) and stroke. AF has been associated with cognitive impairment and cerebral white matter lesions. We wished to investigate the possible direct association between atrial remodeling and cerebrovascular disease in patients with and without AF documented by implantable loop recorder (ILR). METHODS: Cardiac and cerebral magnetic resonance imaging were acquired in a cross-sectional study, including participants ≥70 years of age with stroke risk factors without known AF. Cerebrovascular disease was visually rated using the Fazekas scale and number of lacunar strokes. Left atrial (LA) and ventricular volumes and function were analyzed. Associations between atrial remodeling and cerebrovascular disease were assessed with logistic regression models. The analyses were stratified according to sinus rhythm or any AF during 3 months of continuous ILR monitoring to account for subclinical AF. RESULTS: Of 200 participants investigated, 87% had a Fazekas score ≥1 and 45% had ≥1 lacunar infarct. Within 3 months of ILR monitoring, AF was detected in 28 (14%) participants. For participants with sinus rhythm (n = 172), lower LA passive emptying fraction was associated with Fazekas score after multivariable adjustment (OR [95% CI]: 0.51 [0.27; 0.86] p = 0.02), and increased LA maximum (OR [95% CI]: 1.38 [1.07; 1.82] p = 0.01) and minimum volumes (OR [95% CI]: 1.48 [1.03; 2.17] p = 0.04) were associated with lacunar infarcts. There were no significant associations in patients with AF. CONCLUSION: In AF-free patients, as documented by ILR monitoring, we found an independent association between LA passive emptying fraction and Fazekas score and between atrial volumes and lacunar infarcts.
Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Trastornos Cerebrovasculares , Accidente Vascular Cerebral Lacunar , Accidente Cerebrovascular , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Trastornos Cerebrovasculares/complicaciones , Trastornos Cerebrovasculares/diagnóstico por imagen , Estudios Transversales , Humanos , Imagen por Resonancia Magnética , Accidente Cerebrovascular/complicaciones , Accidente Vascular Cerebral Lacunar/complicaciones , Accidente Vascular Cerebral Lacunar/etiologíaRESUMEN
AIMS: Treatment patterns were compared between randomized groups in EAST-AFNET 4 to assess whether differences in anticoagulation, therapy of concomitant diseases, or intensity of care can explain the clinical benefit achieved with early rhythm control in EAST-AFNET 4. METHODS AND RESULTS: Cardiovascular treatment patterns and number of visits were compared between randomized groups in EAST-AFNET 4. Oral anticoagulation was used in >90% of patients during follow-up without differences between randomized groups. There were no differences in treatment of concomitant conditions between groups. The type of rhythm control varied by country and centre. Over time, antiarrhythmic drugs were given to 1171/1395 (84%) patients in early therapy, and to 202/1394 (14%) in usual care. Atrial fibrillation (AF) ablation was performed in 340/1395 (24%) patients randomized to early therapy, and in 168/1394 (12%) patients randomized to usual care. 97% of rhythm control therapies were within class I and class III recommendations of AF guidelines. Patients randomized to early therapy transmitted 297 166 telemetric electrocardiograms (ECGs) to a core lab. In total, 97 978 abnormal ECGs were sent to study sites. The resulting difference between study visits was low (0.06 visits/patient/year), with slightly more visits in early therapy (usual care 0.39 visits/patient/year; early rhythm control 0.45 visits/patient/year, P < 0.001), mainly due to visits for symptomatic AF recurrences or recurrent AF on telemetric ECGs. CONCLUSION: The clinical benefit of early, systematic rhythm control therapy was achieved using variable treatment patterns of antiarrhythmic drugs and AF ablation, applied within guideline recommendations.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Antiarrítmicos/uso terapéutico , Anticoagulantes/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Prevención Secundaria , Accidente Cerebrovascular/terapiaRESUMEN
BACKGROUND: Long-term rhythm monitoring (LTRM) can detect undiagnosed atrial fibrillation (AF) in patients at high risk of AF and stroke. Biomarkers and echocardiographic parameters could, however, help identify patients benefitting most from LTRM. The aim of this study was to investigate, whether circulating biomarkers of cardiac and vascular function (brain natriuretic peptide (BNP), cardiac troponin I (cTnI), copeptin, and mid-regional proadrenomedullin (MR-proADM)) and echocardiographic parameters were associated with incident subclinical AF (SCAF) in a population at high risk of stroke in the presence of AF. For this purpose, we investigated individuals ≥65 years of age with hypertension and diabetes mellitus, but no history or symptoms of AF or other cardiovascular disease (CVD). METHODS: We included 82 consecutive patients (median age 71.3 years (IQR 67.4-75.1)). All patients received an insertable cardiac monitor (ICM) and were followed for a median of 588 days (IQR 453-712). On the day of ICM implantation, a comprehensive echocardiogram and blood samples were obtained. RESULTS: During a median follow-up of 588 days (IQR: 453-712 days), incident SCAF occurred in 17 patients (20.7%) with a median time to first-detected episode of 91 days (IQR 41-251 days). MR-proADM (median 0.87 nmol/L (IQR 0.76-1.02) vs 0.78 nmol/L (IQR 0.68-0.98)) and copeptin (median 13 pmol/L (IQR 9-17) vs 8 pmol/L (IQR 4-18)) levels were insignificantly higher in patients with incident SCAF. BNP and cTnI concentrations and echocardiographic parameters were similar in the two groups. CONCLUSIONS: MR-proADM, BNP, cTnI, copeptin, and several echocardiographic parameters were not associated with incident SCAF in this cohort of patients with hypertension and diabetes, but without any underlying CVD.
Asunto(s)
Fibrilación Atrial/sangre , Fibrilación Atrial/diagnóstico por imagen , Biomarcadores/sangre , Complicaciones de la Diabetes/sangre , Complicaciones de la Diabetes/diagnóstico por imagen , Ecocardiografía , Hipertensión/complicaciones , Anciano , Electrocardiografía , Femenino , Humanos , Masculino , Estudios Prospectivos , Factores de RiesgoRESUMEN
AIMS: The aim of this study was to investigate the association between within-individual changes in physical activity and onset of atrial fibrillation (AF). METHODS AND RESULTS: A total of 1410 participants from the general population (46.2% women, mean age 74.7 ± 4.1 years) with risk factors but with no prior AF diagnosis underwent continuous monitoring for AF episodes along with daily accelerometric assessment of physical activity using an implantable loop recorder during ≈3.5 years. The combined duration of monitoring was ≈1.6 million days, where 10 851 AF episodes lasting ≥60 min were detected in 361 participants (25.6%) with a median of 5 episodes (2, 25) each. The median daily physical activity was 112 (66, 168) min/day. A dynamic parameter describing within-individual changes in daily physical activity, i.e. average daily activity in the last week compared to the previous 100 days, was computed and used to model the onset of AF. A 1-h decrease in average daily physical activity was associated with AF onset the next day [odds ratio 1.24 (1.18-1.31)]. This effect was modified by overall level of activity (P < 0.001 for interaction), and the signal was strongest in the tertile of participants with lowest activity overall [low: 1.62 (1.41-1.86), mid: 1.27 (1.16-1.39), and high: 1.10 (1.01-1.19)]. CONCLUSIONS: Within-individual changes in physical activity are associated with the onset of AF episodes as detected by continuous monitoring in a high-risk population. For each person, a 1-h decrease in daily physical activity during the last week increased the odds of AF onset the next day by ≈25%, while the strongest association was seen in the group with the lowest activity overall. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, identifier: NCT02036450.