Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Scand Cardiovasc J ; 58(1): 2335906, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38613333

RESUMEN

Objective: The multibranched off-the-shelf Zenith® t-Branch (Cook Medical, Bloomington, IN) device is commonly chosen for endovascular repair of thoracoabdominal aortic aneurysms. The aim of this study was to report early and mid-term outcomes in all patients treated with the t-Branch in Norway; Design and Methods: A retrospective multicenter study with Norwegian centers performing complex endovascular aortic repair was undertaken. T-Branch patients from 2014 to 2020 were included. All postoperative computed tomography angiography images were reviewed, and demographic, anatomical, perioperative and follow-up data were analyzed; Results: Seventy patients were treated in a single-step (n = 55) or staged (n = 15) procedure. Symptomatic presentation was seen in 20 patients, six of which had a contained rupture. Technical success was 87% (n = 59), with failures caused by unsuccessful bridging of target vessels (n = 4), target vessel bleeding (n = 3), persisting type 1c endoleak (n = 1) and t-Branch malrotation (n = 1). 30-day mortality was 9% (n = 6) and was associated with high BMI (p = .038). The spinal cord ischemia rate was 21% (n = 15) and was associated with type II aneurysms (OR 5.4, 95% CI 1.1-26.7, p = .04), smoking (OR 6.0, 95% CI 1.3-27.6, p = .02) and intraoperative blood loss (OR 1.1, 95% CI 1.0-1.3, p = .01). Survival at one, two and three years was 84 ± 4%, 70 ± 6% and 67 ± 6%, respectively. Freedom from aortic-related reinterventions at one, two and three years was 80 ± 5%, 65 ± 7% and 50 ± 8%, respectively; Conclusion: The study showed low early mortality (9%) and satisfactory mid-term survival. Technical success was achieved in acceptable 87% of procedures. The rate of spinal cord ischemia was high, occurring in 21% of patients.


This paper provides a national experience of all TAAA patients treated with the multibranched t-Branch stent graft in Norway in a multi-center study. As we aimed at including all Norwegian patients operated with the device, the paper adds real-world data on t-Branch outcomes from four regional smaller-volume vascular centers.The paper provides technical and clinical mid-term results with several patients being followed up for >3 years.Technical success was achieved in 87% of procedures.The 30-day mortality rate was 9% and survival at one, two and three years was 85 ± 4%, 70 ± 6% and 67 ± 6%, respectively.Spinal cord ischemia was associated with Crawford type II aneurysms, smoking and intraoperative blood loss.


Asunto(s)
Aneurisma de la Aorta Toracoabdominal , Procedimientos Endovasculares , Isquemia de la Médula Espinal , Humanos , Aorta , Angiografía , Procedimientos Endovasculares/efectos adversos
2.
Neurocrit Care ; 2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38448744

RESUMEN

BACKGROUND: Today, invasive intracranial pressure (ICP) measurement remains the standard, but its invasiveness limits availability. Here, we evaluate a novel ultrasound-based optic nerve sheath parameter called the deformability index (DI) and its ability to assess ICP noninvasively. Furthermore, we ask whether combining DI with optic nerve sheath diameter (ONSD), a more established parameter, results in increased diagnostic ability, as compared to using ONSD alone. METHODS: We prospectively included adult patients with traumatic brain injury with invasive ICP monitoring, which served as the reference measurement. Ultrasound images and videos of the optic nerve sheath were acquired. ONSD was measured at the bedside, whereas DI was calculated by semiautomated postprocessing of ultrasound videos. Correlations of ONSD and DI to ICP were explored, and a linear regression model combining ONSD and DI was compared to a linear regression model using ONSD alone. Ability of the noninvasive parameters to distinguish dichotomized ICP was evaluated using receiver operating characteristic curves, and a logistic regression model combining ONSD and DI was compared to a logistic regression model using ONSD alone. RESULTS: Forty-four ultrasound examinations were performed in 26 patients. Both DI (R = - 0.28; 95% confidence interval [CI] R < - 0.03; p = 0.03) and ONSD (R = 0.45; 95% CI R > 0.23; p < 0.01) correlated with ICP. When including both parameters in a combined model, the estimated correlation coefficient increased (R = 0.51; 95% CI R > 0.30; p < 0.01), compared to using ONSD alone, but the model improvement did not reach statistical significance (p = 0.09). Both DI (area under the curve [AUC] 0.69, 95% CI 0.53-0.83) and ONSD (AUC 0.72, 95% CI 0.56-0.86) displayed ability to distinguish ICP dichotomized at ICP ≥ 15 mm Hg. When using both parameters in a combined model, AUC increased (0.80, 95% CI 0.63-0.90), and the model improvement was statistically significant (p = 0.02). CONCLUSIONS: Combining ONSD with DI holds the potential of increasing the ability of optic nerve sheath parameters in the noninvasive assessment of ICP, compared to using ONSD alone, and further study of DI is warranted.

3.
J Endovasc Ther ; : 15266028221123434, 2022 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-36121010

RESUMEN

PURPOSE: Cannulation of visceral vessels is necessary during fenestrated and branched endovascular aortic repair. In an attempt to reduce the associated radiation and contrast dose, an electromagnetically (EM) trackable and manually steerable catheter has been developed. The purpose of this preclinical swine study was to evaluate the cannulation performance and compare the cannulation performance using either EM tracking or image fusion as navigation tools. MATERIALS AND METHODS: Both renal arteries, the superior mesenteric artery, and the celiac trunk were attempted to be cannulated using a 7F steerable, EM trackable catheter in 3 pigs. Seven operators attempted cannulation using first 3-dimensional (3D) image navigation with EM tracking and then conventional image fusion guidance. The rate of successful cannulation was recorded, as well as procedure time and radiation exposure. Due to the lack of an EM trackable guidewire, cannulations that required more than 1 attempt were attempted only with image fusion. The EM tracking position data were registered to preoperative 3D images using a vessel-based registration algorithm. RESULTS: A total of 72 cannulations were attempted with both methods, and 79% (57) were successful on the first attempt for both techniques. There was no difference in cannulation rate (p=1), and time-use was similar. Successful cannulation with image fusion was achieved in 97% of cases when multiple attempts were allowed. CONCLUSION: This study demonstrated the feasibility of a steerable and EM trackable catheter with 3D image navigation. Navigation performance with EM tracking was similar to image fusion, without statistically significant differences in cannulation rates and procedure times. Further studies are needed to demonstrate this utility in patients with aortic disease. CLINICAL IMPACT: Electromagnetic tracking in combination with a novel steerable catheter reduces radiation and contrast media doses while providing three-dimensional visualization and agile navigation during endovascular aortic procedures.

4.
Tidsskr Nor Laegeforen ; 140(6)2020 04 21.
Artículo en Inglés, Noruego | MEDLINE | ID: mdl-32321219

RESUMEN

BACKGROUND: Ultrasound is widely used in vascular surgery. Pocket-sized ultrasound devices have limited functionality compared to conventional ultrasound scanners, but are cheaper and highly portable. The aim of this study was to investigate whether vascular surgeons could benefit from using a pocket ultrasound device in everyday clinical practice. MATERIAL AND METHOD: Pocket-sized ultrasound devices were made available in the Department of Vascular Surgery at St. Olavs Hospital, Trondheim University Hospital, for a 10-month period. Eleven doctors participated and were free to choose between a conventional ultrasound scanner and a pocket ultrasound device. After each use of a pocket ultrasound device, participants completed a form describing the indication for use, whether the clinical question was answered, the image quality experienced and the need for supplementary diagnostic imaging. At the end of the study period, each user completed a questionnaire. RESULTS: Pocket ultrasound devices were mainly used preoperatively. The clinical question was answered in 51 (85 %) of 60 registered examinations with a pocket ultrasound device. Image quality was subjectively rated as good in 32 (53 %) examinations, moderate in 21 (35 %) and poor in 7 (12 %), with the clinical question answered in 94 %, 90 % and 29 % of cases, respectively. Doctors with less than five years of experience with ultrasound chose pocket ultrasound more frequently than more experienced users. INTERPRETATION: For the examinations selected, the images supplied by the pocket ultrasound device were generally of sufficient quality and often answered the clinical question. Pocket ultrasound devices can be a useful supplementary tool in vascular surgery, especially for venous examinations.


Asunto(s)
Médicos , Especialidades Quirúrgicas , Humanos , Examen Físico , Ultrasonografía
7.
Minim Invasive Ther Allied Technol ; 28(2): 127-133, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30810444

RESUMEN

BACKGROUND: Combining electromagnetic tracking of instruments with preoperatively acquired images can provide detailed visualization for intraoperative guidance and reduce the need for fluoroscopy and contrast. In this study, we investigated the accuracy of a vessel-based registration method designed for matching preoperative image and electromagnetically tracked positions for endovascular therapy. MATERIAL AND METHODS: An open-source registration method was used to match the centerline extracted from computed tomography (CT) to electromagnetically tracked positions within a vascular phantom representing the abdominal aorta with bifurcations. The target registration error (TRE) was calculated for 11 fiducials distributed over the phantom. Median and intra-quartile range (IQR) for 30 registrations was reported. TRE < 5 mm was claimed sufficient for endovascular navigation, evaluated using the Wilcoxon signed-rank test. TRE was also compared to a 3D-3D registration method based on intraoperative cone-beam CT, using the Mann-Whitney U-test. RESULTS: The TRE was 3.75 (IQR: 3.48-3.99) mm for the centerline registration algorithm and 3.21 (IQR: 1.50-3.57) mm for the 3D-3D method (p < .001). For both methods, the TRE was significantly < 5 mm (p < .001). CONCLUSION: The centerline registration method was feasible, with an accuracy sufficient for navigation in endovascular therapy. The centerline method avoids additional image acquisition for registration purpose only.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/cirugía , Procedimientos Endovasculares/métodos , Imagenología Tridimensional/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Inteligencia Artificial , Tomografía Computarizada de Haz Cónico , Fenómenos Electromagnéticos , Fluoroscopía , Humanos , Fantasmas de Imagen
9.
Front Radiol ; 4: 1320535, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38333532

RESUMEN

Electromagnetic tracking of instruments combined with preoperative images can supplement fluoroscopy for guiding endovascular aortic repair (EVAR). The aim of this study was to evaluate the in-vivo accuracy of a vessel-based registration algorithm for matching electromagnetically tracked positions of an endovascular instrument to preoperative computed tomography angiography. Five patients undergoing elective EVAR were included, and a clinically available semi-automatic 3D-3D registration algorithm, based on similarity measures computed over the entire image, was used for reference. Accuracy was reported as target registration error (TRE) evaluated in manually selected anatomic landmarks on bony structures, placed close to the volume-of-interest. The median TRE was 8.2 mm (range: 7.1 mm to 16.1 mm) for the vessel-based registration algorithm, compared to 2.2 mm (range: 1.8 mm to 3.7 mm) for the reference algorithm. This illustrates that registration based on intraoperative electromagnetic tracking is feasible, but the accuracy must be improved before clinical use.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38824470

RESUMEN

PURPOSE: Currently, the intra-operative visualization of vessels during endovascular aneurysm repair (EVAR) relies on contrast-based imaging modalities. Moreover, traditional image fusion techniques lack a continuous and automatic update of the vessel configuration, which changes due to the insertion of stiff guidewires. The purpose of this work is to develop and evaluate a novel approach to improve image fusion, that takes into account the deformations, combining electromagnetic (EM) tracking technology and finite element modeling (FEM). METHODS: To assess whether EM tracking can improve the prediction of the numerical simulations, a patient-specific model of abdominal aorta was segmented and manufactured. A database of simulations with different insertion angles was created. Then, an ad hoc sensorized tool with three embedded EM sensors was designed, enabling tracking of the sensors' positions during the insertion phase. Finally, the corresponding cone beam computed tomography (CBCT) images were acquired and processed to obtain the ground truth aortic deformations of the manufactured model. RESULTS: Among the simulations in the database, the one minimizing the in silico versus in vitro discrepancy in terms of sensors' positions gave the most accurate aortic displacement results. CONCLUSIONS: The proposed approach suggests that the EM tracking technology could be used not only to follow the tool, but also to minimize the error in the predicted aortic roadmap, thus paving the way for a safer EVAR navigation.

11.
Med Eng Phys ; 125: 104116, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38508792

RESUMEN

The purpose of this study was to evaluate the accuracy of a method for estimating the tip position of a fiber optic shape-sensing (FOSS) integrated instrument being inserted through a bronchoscope. A modified guidewire with a multicore optical fiber was inserted into the working channel of a custom-made catheter with three electromagnetic (EM) sensors. The displacement between the instruments was manually set, and a point-based method was applied to match the position of the EM sensors to corresponding points on the shape. The accuracy was evaluated in a realistic bronchial model. An additional EM sensor was used to sample the tip of the guidewire, and the absolute deviation between this position and the estimated tip position was calculated. For small displacements between the tip of the FOSS integrated tool and the catheter, the median deviation in estimated tip position was ≤5 mm. For larger displacements, deviations exceeding 10 mm were observed. The deviations increased when the shape sensor had sharp curvatures relative to more straight shapes. The method works well for clinically relevant displacements of a biopsy tool from the bronchoscope tip, and when the path to the lesion has limited curvatures. However, improvements must be made to our configuration before pursuing further clinical testing.


Asunto(s)
Broncoscopía , Fenómenos Electromagnéticos , Broncoscopía/métodos , Fantasmas de Imagen , Catéteres
12.
Front Neurol ; 14: 1064492, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36816558

RESUMEN

Introduction: Optic nerve sheath diameter (ONSD) has shown promise as a noninvasive parameter for estimating intracranial pressure (ICP). In this study, we evaluated a novel automated method of measuring the ONSD in transorbital ultrasound imaging. Methods: From adult traumatic brain injury (TBI) patients with invasive ICP monitoring, bedside manual ONSD measurements and ultrasound videos of the optic nerve sheath complex were simultaneously acquired. Automatic ONSD measurements were obtained by the processing of the ultrasound videos by a novel software based on a machine learning approach for segmentation of the optic nerve sheath. Agreement between manual and automated measurements, as well as their correlation to invasive ICP, was evaluated. Furthermore, the ability to distinguish dichotomized ICP for manual and automatic measurements of ONSD was compared, both for ICP dichotomized at ≥20 mmHg and at the 50th percentile (≥14 mmHg). Finally, we performed an exploratory subgroup analysis based on the software's judgment of optic nerve axis alignment to elucidate the reasons for variation in the agreement between automatic and manual measurements. Results: A total of 43 ultrasound examinations were performed on 25 adult patients with TBI, resulting in 86 image sequences covering the right and left eyes. The median pairwise difference between automatically and manually measured ONSD was 0.06 mm (IQR -0.44 to 0.38 mm; p = 0.80). The manually measured ONSD showed a positive correlation with ICP, while automatically measured ONSD showed a trend toward, but not a statistically significant correlation with ICP. When examining the ability to distinguish dichotomized ICP, manual and automatic measurements performed with similar accuracy both for an ICP cutoff at 20 mmHg (manual: AUC 0.74, 95% CI 0.58-0.88; automatic: AUC 0.83, 95% CI 0.66-0.93) and for an ICP cutoff at 14 mmHg (manual: AUC 0.70, 95% CI 0.52-0.85; automatic: AUC 0.68, 95% CI 0.48-0.83). In the exploratory subgroup analysis, we found that the agreement between measurements was higher in the subgroup where the automatic software evaluated the optic nerve axis alignment as good as compared to intermediate/poor. Conclusion: The novel automated method of measuring the ONSD on the ultrasound videos using segmentation of the optic nerve sheath showed a reasonable agreement with manual measurements and performed equally well in distinguishing high and low ICP.

13.
BMC Med Imaging ; 12: 11, 2012 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-22621614

RESUMEN

BACKGROUND: Image contrast between normal tissue and brain tumours may sometimes appear to be low in intraoperative ultrasound. Ultrasound imaging of strain is an image modality that has been recently explored for intraoperative imaging of the brain. This study aims to investigate differences in image contrast between ultrasound brightness mode (B-mode) images and ultrasound strain magnitude images of brain tumours. METHODS: Ultrasound radiofrequency (RF) data was acquired during surgery in 15 patients with glial tumours. The data were subsequently processed to provide strain magnitude images. The contrast in the B-mode images and the strain images was determined in assumed normal brain tissue and tumour tissue at selected regions of interest (ROI). Three measurements of contrast were done in the ultrasound data for each patient. The B-mode and strain contrasts measurements were compared using the paired samples t- test. RESULTS: The statistical analysis of a total of 45 measurements shows that the contrasts in the strain magnitude images are significantly higher than in the conventional ultrasound B-mode images (P < 0.0001). CONCLUSIONS: The results indicate that ultrasound strain imaging provides better discrimination between normal brain tissue and glial tumour tissue than conventional ultrasound B-mode imaging. Ultrasound imaging of tissue strain therefore holds the potential of becoming a valuable adjunct to conventional intraoperative ultrasound imaging in brain tumour surgery.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/fisiopatología , Diagnóstico por Imagen de Elasticidad/métodos , Glioma/diagnóstico por imagen , Glioma/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Adulto , Anciano , Módulo de Elasticidad , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
EJVES Vasc Forum ; 56: 6-10, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35572162

RESUMEN

Objective: To investigate technical and clinical outcomes in patients with thoraco-abdominal aortic aneurysms treated with the multibranched off the shelf Zenith t-Branch stent graft or a custom made device (CMD). Methods: A retrospective study was conducted of patients operated on at a single tertiary vascular centre in Norway. Twenty eight t-Branch and 17 CMD patients were identified. Demographic, aneurysm, and peri-operative data were summarised and compared. Results: Thirty day mortality was 4% (2/45), with mortality rates of 7% (2/28) and 0 in t-Branch and CMD patients, respectively (p = .52). Technical success was 87% (39/45), with a non-significant difference between t-Branch and CMD procedures of 89% (25/28) and 82% (14/17), respectively (p = .63). Stent graft coverage was significantly longer in t-Branch patients (p = .020). Paraparesis or paraplegia developed in 18% (5/28) of t-Branch patients and 12% (2/17) of CMD patients (p = .69), and spinal cord ischaemia was associated with Crawford type II aneurysms (p = .010) and aortic coverage >400 mm (p = .050). The estimated survival at one and two years for t-Branch patients was 93% and 88%, and 100% and 92% for CMD patients. Freedom from re-intervention was estimated at 70% and 43% at one and two years for t-Branch patients, and 58% and 50% for CMD patients. Conclusion: The study showed low 30 day mortality rates, acceptable technical success rates, high medium term survival, and no statistically significant differences in clinically relevant outcomes between t-Branch and CMD patients.

15.
JSLS ; 14(3): 399-404, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21333196

RESUMEN

BACKGROUND AND OBJECTIVES: Laparoscopic treatment of incisional hernias reduces surgical traumas and postoperative pain. It requires intraperitoneal placement of a foreign body that might cause adhesions, leading to postoperative complications. The aim of this study was to improve reliability of ultrasound in quantitatively estimating adhesions to exploit the other advantages of ultrasound, such as availability and versatility. METHODS: The ultrasound examination was performed by using a hand-held 3.5 MHz curved linear probe. The image data were analyzed prior to scan conversion. Two square regions of interest were defined, one in the abdominal wall and one in the underlying bowels. A cross correlation-based algorithm tracked each region by using a time span of 3 frames. Subtracting the 2 displacement functions from each other yielded a relative displacement function, indicating the degree of bowel adhesions. This was compared with the intraoperative findings. RESULTS AND CONCLUSIONS: The method was proven to be a rapid and robust method for quantitatively estimating the degree of bowel adhesions. It is limited to evaluation of adhesions between bowel and abdominal wall. However, this ultrasound technique could assist in the safe placement of ports prior to redo laparoscopic surgery.


Asunto(s)
Hernia Ventral/cirugía , Laparoscopía/efectos adversos , Adherencias Tisulares/diagnóstico por imagen , Humanos , Complicaciones Posoperatorias , Índice de Severidad de la Enfermedad , Adherencias Tisulares/etiología , Ultrasonografía , Cicatrización de Heridas
16.
Minim Invasive Ther Allied Technol ; 19(2): 69-74, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20337541

RESUMEN

Although ultrasound has become an important imaging modality within several medical professions, the benefit of ultrasound depends to some degree on the skills of the person operating the probe and interpreting the image. For some applications, the possibility to educate operators in a clinical setting is limited, and the use of training simulators is considered an alternative approach for learning basic skills. To ensure the quality of simulator-based training, it is important to produce simulated ultrasound images that resemble true images to a sufficient degree. This article describes a method that allows corresponding true and simulated ultrasound images to be generated and displayed side by side in real time, thus facilitating an interactive evaluation of ultrasound simulators in terms of image resemblance, real-time characteristics and man-machine interaction. The proposed method could be used to study the realism of ultrasound simulators and how this realism affects the quality of training, as well as being a valuable tool in the development of simulation algorithms.


Asunto(s)
Competencia Clínica , Simulación por Computador , Ultrasonografía/métodos , Algoritmos , Educación Médica/métodos , Humanos , Maniquíes
17.
Oper Neurosurg (Hagerstown) ; 16(6): 726-733, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30169680

RESUMEN

BACKGROUND: Measurement of optic nerve sheath diameter (ONSD) is a promising technique for noninvasive assessment of intracranial pressure (ICP), but has certain limitations. A recent study showed that the deformability index (DI), a dynamic parameter quantifying the pulsatile nature of the optic nerve sheath, could differentiate between patients with high vs normal ICP. OBJECTIVE: To further evaluate the diagnostic accuracy of the DI, when interpreted together with ONSD. METHODS: This prospective study included children undergoing invasive ICP measurement as part of their clinical management. Ultrasound images of the optic nerve sheath were acquired prior to measuring ICP, the images were further processed to obtain the DI. Patients were dichotomized into high (≥20 mm Hg) or normal ICP groups and compared using the Mann-Whitney U-test. Diagnostic accuracy was described using area under the receiver operating characteristic curve (AUC), sensitivity and specificity, correlation between DI, ONSD, and ICP was investigated using linear regression. RESULTS: A total of 28 patients were included (19 high ICP). The DI was lower in the high ICP group (0.105 vs 0.28, P = .001). AUC was 0.87, and a cut-off value of DI ≤ 0.185 demonstrated sensitivity of 89.5% and specificity of 88.9%. Diagnostic accuracy improved when combining DI with ONSD (AUC 0.98, sensitivity 94.7%, specificity 88.9%) and correlation with ICP improved when combined analysis of DI and ONSD was performed (Pearson correlation coefficient: 0.82 vs 0.42, respectively, P = .012). CONCLUSION: The DI was significantly lower for patients with high vs normal ICP. This relationship improved further when the DI and ONSD were interpreted together.


Asunto(s)
Hipertensión Intracraneal/diagnóstico por imagen , Presión Intracraneal , Vaina de Mielina/patología , Nervio Óptico/diagnóstico por imagen , Ultrasonografía/métodos , Lesiones Traumáticas del Encéfalo/complicaciones , Neoplasias del Ventrículo Cerebral/complicaciones , Niño , Preescolar , Craneosinostosis/complicaciones , Femenino , Humanos , Hidrocefalia/complicaciones , Lactante , Hipertensión Intracraneal/etiología , Hipertensión Intracraneal/patología , Masculino , Monitoreo Fisiológico , Vaina de Mielina/fisiología , Nervio Óptico/patología , Nervio Óptico/fisiopatología , Órbita , Tamaño de los Órganos , Estudios Prospectivos
18.
Clin Med Insights Cardiol ; 12: 1179546817751432, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29326533

RESUMEN

PURPOSE: A prototype steerable catheter was designed for endovascular procedures. This technical pilot study reports the initial experience using the catheter for cannulation of visceral arteries. TECHNIQUE: The 7F catheter was manually steerable with operator control handle for bending and rotation of the tip. The maximum bending angle was approximately 90° and full 360° rotation of the tip was supported. The study involved 1 pig with 4 designated target arteries: the left and right renal arteries, the superior mesenteric artery, and the celiac trunk. Fluoroscopy with 3-dimensional (3D) overlay showing the ostia from preoperative computed tomography angiography was used for image guidance. The cannulation was considered successful if the guidewire was placed well inside the target artery. In addition to evaluating cannulation success, procedure time and associated radiation doses were recorded. The procedure was performed twice with 2 different operators. CONCLUSIONS: Both operators successfully reached all 4 target arteries, demonstrating the feasibility of the steerable catheter for endovascular cannulation of visceral arteries. No contrast medium was used, and median radiation dose was 4.5 mGy per cannulation. An average of approximately 2 minutes was used per cannulation. This study motivates further testing in a more comprehensive study to evaluate reproducibility in several animals and with inclusion of more operators. Further development by integrating the new catheter tool in a navigation system is also an interesting next step, combining fine control of catheter tip movements and 3D image guidance without ionizing radiation.

19.
Ultrasound Med Biol ; 32(1): 33-42, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16364795

RESUMEN

The rupture risk of abdominal aortic aneurysms (AAAs) is routinely inferred from the maximum diameter of the AAA. However, clinical experience indicates that this criterion has poor accuracy and that noninvasive assessment of the elastic properties of the vessel might give better correspondence with the rupture risk. We have developed a method for analysis of circumferential strain in AAAs from sequences of cross-sectional ultrasound B-mode images. The algorithm is fast, semiautomatic and well-suited for real-time applications. The method was developed and evaluated using data from 10 AAA patients. The preliminary results demonstrate that the method is sufficiently accurate and robust for clinically acquired data. An important finding is that local strain values may exceed the circumferential average strain significantly. Furthermore, the calculated strain shows no apparent covariation with the diagnosed diameter. This implies that the method may give new and essential information on the clinical condition of the AAA.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Estrés Fisiológico/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Algoritmos , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/fisiopatología , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/fisiopatología , Elasticidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Estrés Fisiológico/fisiopatología , Ultrasonografía
20.
Neurosurgery ; 79(1): 100-7, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26813857

RESUMEN

BACKGROUND: Raised intracranial pressure (ICP) may lead to increased stiffness of the optic nerve sheath (ONS). OBJECTIVE: To develop a method for analyzing ONS dynamics from transorbital ultrasound and investigate a potential difference between patients with raised ICP vs normal ICP. METHODS: We retrospectively analyzed data from 16 patients (≤12 years old) for whom ultrasound image sequences of the ONS had been acquired from both eyes just before invasive measurement of ICP. Eight patients had an ICP ≥20 mm Hg. The transverse motion on each side of the ONS was estimated from ultrasound, and Fourier analysis was used to extract the magnitude of the displacement corresponding to the heart rate. By calculating the normalized absolute difference between the displacements on each side of the ONS, a measure of ONS deformation was obtained. This parameter was referred to as the deformability index. According to our hypothesis, because deformability is inversely related to stiffness, we expected this parameter to be lower for ICP ≥20 mm Hg compared with ICP <20 mm Hg. The one-sided Mann-Whitney U test was used for statistical comparison. RESULTS: The deformability index was significantly lower in the group with ICP ≥20 mm Hg (median value 0.11 vs 0.24; P = .002). CONCLUSION: We present a method for assessment of ONS pulsatile dynamics using transorbital ultrasound imaging. A significant difference was noted between the patient groups, indicating that deformability of the ONS may be relevant as a noninvasive marker of raised ICP. The clinical implications are promising and should be investigated in future clinical studies. ABBREVIATIONS: AUC, area under curveICP, intracranial pressureONS, optic nerve sheathONSD, optic nerve sheath diameterROC, receiver operating characteristic.


Asunto(s)
Hipertensión Intracraneal/fisiopatología , Presión Intracraneal/fisiología , Nervio Óptico/fisiología , Flujo Pulsátil/fisiología , Encéfalo/fisiopatología , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Nervio Óptico/diagnóstico por imagen , Curva ROC , Estudios Retrospectivos , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA