Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Perfusion ; 38(4): 872-875, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-35262440

RESUMEN

INTRODUCTION: Heart surgery can be associated with adverse ischemic brain events. CASE REPORT: Here, we describe two patients who presented extensive infarction of the corpus callosum and of other brain watershed areas following coronary artery bypass grafting (CABG) on extracorporeal circulation (ECC). DISCUSSION: Infarction of the corpus callosum is an extremely rare condition due to its abundant blood supply. Our findings are noteworthy since they diverge from classical brain watershed infarcts and from other cases of corpus callosum involvement. This suggests that in some cases, CABG surgery on ECC may be associated to a profound impairment of intracerebral circulation. However, it is also possible that the corpus callosum is particularly vulnerable to yet unknown metabolic modifications connected to ECC. CONCLUSIONS: Further studies are needed in order to investigate the complex response of brain circulation and metabolism during heart surgery with ECC.


Asunto(s)
Puente de Arteria Coronaria , Cuerpo Calloso , Humanos , Puente de Arteria Coronaria/efectos adversos , Circulación Extracorporea/efectos adversos , Isquemia/etiología , Infarto/etiología
2.
Catheter Cardiovasc Interv ; 99(5): 1599-1608, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35043541

RESUMEN

OBJECTIVE: The objective of this study is to compare hemodynamic and echocardiographic findings between valve-in-valve (VIV) and native-valve (NV) patients submitted to transcatheter aortic valve implantation (TAVI) due to pure aortic regurgitation (AR). BACKGROUND: Patients with severe AR are surgically treated with variable postinterventional left-ventricular (LV) "reverse remodeling." TAVI might be considered in selected AR patients. METHODS: Twenty-eight patients with pure severe AR caused by either degenerated bioprosthesis or NV disease were successfully treated by TAVI at our institution. LV catheterization before and after TAVI and echocardiography before, after (24-72 h), and at follow-up (3-12 months) were performed. RESULTS: Baseline clinical, hemodynamic, and echocardiographic characteristics were comparable between the two study groups, except for a younger age, higher proto-diastolic LV pressure, and higher LV end-systolic diameter in the NV group. At catheterization, an immediate hemodynamic impact of TAVI in both groups was noticed, with a trend toward better postprocedural residual regurgitation index and significantly lower LV dP/dT values (666.0 ± 177.9 vs. 883.5 ± 259.7 mmHg/s, p = 0.04) in VIV. At echocardiography, both NV and VIV patients showed favorable (early and sustained) post-TAVI echocardiographically detectable reverse remodeling. VIV patients also showed more pronounced early reduction in indexed LV end-diastolic volume (68.1 ± 27.4 vs. 86.5 ± 28.9 ml/m2 in VIV, p < 0.001 and 81.0 ± 29.0 vs. 95.2 ± 37.8 ml/m2 in NV, p = 0.043). CONCLUSIONS: Successful TAVI induces a striking hemodynamic impact with major structural (reverse remodeling) consequences in patients with pure AR caused by both bioprosthesis degeneration or NV disease. In the immediate postrelease phase, VIV patients might exhibit a more pronounced early LV contractile and structural benefit.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Ecocardiografía/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Remodelación Ventricular
3.
Europace ; 24(7): 1127-1136, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35138367

RESUMEN

AIMS: The aims of this study is to assess by an updated meta-analysis the clinical outcomes related to permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) at long-term (≥12 months) follow-up (LTF). METHODS AND RESULTS: A comprehensive literature research was performed on PubMed and EMBASE. The primary endpoint was all-cause death. Secondary endpoints were rehospitalization for heart failure, stroke, and myocardial infarction. A subgroup analysis was performed according to the Society of Thoracic Surgeon-Predicted Risk of Mortality (STS-PROM) score. This study is registered with PROSPERO (CRD42021243301). A total of 51 069 patients undergoing TAVI from 31 observational studies were included. The mean duration of follow-up was 22 months. At LTF, PPI post-TAVI was associated with a higher risk of all-cause death [risk ratio (RR) 1.18, 95% confidence interval (CI) 1.10-1.25; P < 0.001] and rehospitalization for heart failure (RR 1.32, 95% CI 1.13-1.52; P < 0.001). In contrast, the risks of stroke and myocardial infarction were not affected. Among the 20 studies that reported procedural risk, the association between PPI and all-cause death risk at LTF was statistically significant only in studies enrolling patients with high STS-PROM score (RR 1.25, 95% CI 1.12-1.40), although there was a similar tendency of the results in those at medium and low risk. CONCLUSION: Patients necessitating PPI after TAVI have a higher long-term risk of all-cause death and rehospitalization for heart failure as compared to those who do not receive PPI.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Prótesis Valvulares Cardíacas , Infarto del Miocardio , Marcapaso Artificial , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Humanos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
J Cardiothorac Vasc Anesth ; 36(7): 1919-1926, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34906382

RESUMEN

OBJECTIVE: Previous studies reported a poor outcome in patients with coronavirus 2019 (COVID-19) undergoing cardiac surgery. Complications most frequently described were respiratory failure, renal failure, and thromboembolic events. In their recent experience, the authors observed a very high incidence of bleeding complications. The purpose of the study was to investigate a possible significant correlation between perioperative COVID-19 infection and hemorrhagic complications compared to non-COVID-19 patients. DESIGN: Single-center, observational, retrospective, matched case-control (1:2) study involving patients who underwent open-heart cardiac surgery from February 2020 and March 2021 with positive perioperative diagnosis of COVID-19 infection, matched with patients without COVID-19 infection. SETTING: Cardiac surgery unit and intensive care unit of a university tertiary center in a metropolitan area. PARTICIPANTS: In the study period, 773 patients underwent cardiac surgery on cardiopulmonary bypass (CPB). Among them, 23 consecutive patients had perioperative diagnosis of COVID-19 infection (study group). These patients were compared with 46 corresponding controls (control group) that matched for age, sex, body mass index, and Society of Thoracic Surgeons score. INTERVENTIONS: Open-heart cardiac surgery on CPB. MEASUREMENTS AND MAIN RESULTS: In the study group, 2 patients (9%) died in the intensive care unit from severe respiratory failure, shock, and multiple organ failure. In the study group, patients showed a significantly higher incidence of bleeding complications (48% v 2%, p = 0.0001) and cases of surgical reexploration for bleeding (35% v 2%, p = 0.0001), a higher incidence of severe postoperative thrombocytopenia (39% v 6%, p = 0.0007), and a higher need of blood components transfusions (74% v 30%, p = 0.0006). Chest tubes blood loss and surgical hemostasis time were markedly prolonged (p = 0.02 and p = 0.003, respectively). CONCLUSIONS: A worrisome increased risk of early and late bleeding complications in COVID-19 patients was observed, and it should be considered when assessing the operative risk. CPB-related inflammatory reaction could exacerbate the deleterious effect of COVID-19 on the coagulation system and likely deviate it toward a hemorrhagic pattern.


Asunto(s)
COVID-19 , Procedimientos Quirúrgicos Cardíacos , Insuficiencia Respiratoria , COVID-19/complicaciones , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Estudios de Casos y Controles , Humanos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Insuficiencia Respiratoria/etiología , Estudios Retrospectivos
5.
Eur Heart J Suppl ; 23(Suppl E): E99-E102, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34650365

RESUMEN

Heart failure is a complex clinical syndrome associated with a high mortality and morbidity rate. Despite the extensive pharmacological armamentarium, a non-negligible percentage of patients develop advanced heart failure and require further therapies. In these circumstances, heart transplantation remains the treatment of choice, but the limited number of donors and the reduction of potential candidates have made necessary to develop new technologies. Since the 1980s, left ventricular assist devices (LVADs) have been introduced and have completely revolutionized the landscape of advanced heart failure treatments. This article has identified the categories of patients who can benefit from the implantation of an LVAD and summarized the new classifications. In addition, the main LVADs are described, analysing the results of the main clinical studies, with particular reference to adverse events. Although there is no perfect LVAD, a multidisciplinary team approach, dedicated to the treatment of advanced heart failure, can guide the choices on the best device to implant, in order to minimize complications and improve the patient's quality of life.

6.
Perfusion ; 36(7): 679-687, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34080484

RESUMEN

INTRODUCTION: Minimally invasive aortic valve replacement (MIAVR) requires changes in cannulation strategy and cardiopulmonary bypass (CPB) management when compared to the conventional approach (CAVR). We aimed at evaluating if these differences could influence perfusion-related quality parameters and impair postoperative outcomes. METHODS: Overall, 339 consecutive patients underwent MIAVR or CAVR between 2014 and 2020 and were analyzed retrospectively. To account for baseline differences, a propensity-matching analysis was performed, obtaining two groups of 97 patients each. RESULTS: MIAVR group had longer CPB time [107 (95-120) vs 95 (86-105) min, p = .003] than CAVR group. Of note, average pump flow rate index [2.4 (2.2-2.5) vs 2.7 (2.4-2.8) l/min/m2, p = .004] was lower in the MIAVR group. Mean arterial pressure was 73 = 9 mmHg vs 62 = 11 mmHg for the MIAVR and CAVR group, respectively (p < .001). Cell-salvaged blood was most commonly used in the MIAVR group (25.8% vs 11.3%, p = .02). Finally, CPB temperature was 32.8°C (32.1-34.8) for MIAVR group vs 34.9°C (33.2-36.1) for the CAVR group (p = .02). Postoperative complications were similar between groups. CONCLUSIONS: In conclusion, despite differences in CPB parameters in patients undergoing CAVR and MIAVR, the incidences of adverse outcomes were similar. However, compared to CAVR, MIAVR was associated with shorter durations of mechanical ventilation and hospital stay as well as less transfusion of blood products.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/cirugía , Puente Cardiopulmonar , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Estudios Retrospectivos , Resultado del Tratamiento
7.
Cardiovasc Diabetol ; 19(1): 147, 2020 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-32977814

RESUMEN

BACKGROUND: Peripheral artery disease (PAD) represents one of the most relevant vascular complications of type 2 diabetes mellitus (T2DM). Moreover, T2DM patients suffering from PAD have an increased risk of major adverse cardiovascular events (MACE) and major adverse limb events (MALE). Sortilin, a protein involved in apolipoproteins trafficking, is associated with lower limb PAD in T2DM patients. OBJECTIVE: To evaluate the relationship between baseline serum levels of sortilin, MACE and MALE occurrence after revascularization of T2DM patients with PAD and chronic limb-threatening ischemia (CLTI). RESEARCH DESIGN AND METHODS: We performed a prospective non-randomized study including 230 statin-free T2DM patients with PAD and CLTI. Sortilin levels were measured before the endovascular intervention and incident outcomes were assessed during a 12 month follow-up. RESULTS: Sortilin levels were significantly increased in individuals with more aggressive PAD (2.25 ± 0.51 ng/mL vs 1.44 ± 0.47 ng/mL, p < 0.001). During follow-up, 83 MACE and 116 MALE occurred. In patients, who then developed MACE and MALE, sortilin was higher. In particular, 2.46 ± 0.53 ng/mL vs 1.55 ± 0.42 ng/mL, p < 0.001 for MACE and 2.10 ± 0.54 ng/mL vs 1.65 ± 0.65 ng/mL, p < 0.001 for MALE. After adjusting for traditional atherosclerosis risk factors, the association between sortilin and vascular outcomes remained significant in a multivariate analysis. In our receiver operating characteristics (ROC) curve analysis using sortilin levels the prediction of MACE incidence improved (area under the curve [AUC] = 0.94) and MALE (AUC = 0.72). CONCLUSIONS: This study demonstrates that sortilin correlates with incidence of MACE and MALE after endovascular revascularization in a diabetic population with PAD and CLTI.


Asunto(s)
Proteínas Adaptadoras del Transporte Vesicular/sangre , Enfermedades Cardiovasculares/mortalidad , Diabetes Mellitus Tipo 2/sangre , Angiopatías Diabéticas/cirugía , Isquemia/epidemiología , Infarto del Miocardio/epidemiología , Enfermedad Arterial Periférica/cirugía , Accidente Cerebrovascular/epidemiología , Anciano , Anciano de 80 o más Años , Amputación Quirúrgica/estadística & datos numéricos , Diabetes Mellitus Tipo 2/complicaciones , Angiopatías Diabéticas/sangre , Angiopatías Diabéticas/etiología , Procedimientos Endovasculares , Femenino , Humanos , Incidencia , Isquemia/cirugía , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/sangre , Enfermedad Arterial Periférica/etiología , Pronóstico , Estudios Prospectivos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 96(2): 459-470, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31925991

RESUMEN

OBJECTIVES: To describe and report the results of an original technique for trans-femoral (TF) transcatheter-aortic-valve-replacement (TAVR). BACKGROUND: TF approach represents the commonest TAVR technique. The best technique for TF-TAVR is not recognized. METHODS: We developed a less-invasive totally-endovascular (LITE) technique for TF-TAVR. The key aspects are: precise TAVR access puncture using angiographic-guidewire-ultrasound guidance radial approach as the "secondary access" (to guide valve positioning, to check femoral-access hemostasis and to manage eventual access-site complications) non-invasive pacing (by retrograde left ventricle stimulation or by definitive pace-maker external programmer) The LITE technique has been systematically adopted at our Institution. Procedure details, complications and clinical events occurring during hospitalization were prospectively recorded. Major vascular complications and life-threatening or major bleedings were the primary study end-points. RESULTS: A total of 153 consecutive patients referred for TF-TAVR were approached using the LITE technique. Mean predicted surgical operative mortality was 4.9% and mean TAVR predicted mortality was 3.9%. In 132 (86.3%) patients, TAVR was completed without the need for additional femoral artery access or transvenous temporary pace-maker implantation. Major vascular complications occurred in 2 (1.3%), life-threatening or major bleedings occurred in 4 (2.6%) patients. All-cause death occurred in 3 patients (2.0%). CONCLUSIONS: TF-TAVR according to LITE technique is feasible and is associated with very low rates of vascular or bleeding complications.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Estimulación Cardíaca Artificial , Cateterismo Periférico , Arteria Femoral , Arteria Radial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Punciones , Arteria Radial/diagnóstico por imagen , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
9.
Eur Heart J Suppl ; 22(Suppl L): L93-L96, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33654472

RESUMEN

Secondary mitral insufficiency (SMI) is caused by dilatation and left ventricular dysfunction and is a frequent finding in patients with heart failure (HF). It is associated with a mortality of between 40% and 50% at 3 years. The first-line treatment is represented by medical therapy, possibly associated, when indicated, with cardiac re-synchronization. If the patient remains symptomatic, corrective action should be considered. Surgery is indicated in cases of severe SMI with ejection fraction >30% and the need for myocardial revascularization. The management of patients in whom revascularization is not an option remains extremely complex and the evidence in this field is extremely limited. Percutaneous transcatheter therapies, reparative or replacement, are rapidly emerging as valid alternatives in cases of patients at high surgical risk. In particular, edge-to-edge repair (MitraClip) has proven effective in improving symptoms and reducing hospitalizations for HF. However, neither transcatheter nor surgical mitral repair or replacement has been shown to significantly improve prognosis, with mortality remaining high (14-20% at 1 year). Randomized trials aimed at assessing the effect of these treatments and establishing their long-term outcomes are urgently required.

10.
Int J Mol Sci ; 21(21)2020 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-33143371

RESUMEN

The 2019 novel coronavirus [2019-nCoV], which started to spread from December 2019 onwards, caused a global pandemic. Besides being responsible for the severe acute respiratory syndrome 2 [SARS-CoV-2], the virus can affect other organs causing various symptoms. A close relationship between SARS-CoV-2 and the cardiovascular system has been shown, demonstrating an epidemiological linkage between SARS-CoV-2 and cardiac injury. There are emerging data regarding possible direct myocardial damage by 2019-nCoV. In this review, the most important available evidences will be discussed to clarify the precise mechanisms of cardiovascular injury in SARS-CoV-2 patients, even if further researches are needed.


Asunto(s)
Enfermedades Cardiovasculares/etiología , Infecciones por Coronavirus/complicaciones , Neumonía Viral/complicaciones , Animales , Betacoronavirus/inmunología , COVID-19 , Enfermedades Cardiovasculares/epidemiología , Infecciones por Coronavirus/inmunología , Humanos , Pandemias , Neumonía Viral/inmunología , SARS-CoV-2
11.
Catheter Cardiovasc Interv ; 91(5): 938-944, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-29068124

RESUMEN

OBJECTIVES: We sought to investigate the possible impact of transaortic valve replacement (TAVR) on common femoral artery (CFA) integrity as assessed by angiography. BACKGROUND: CFA represents the most adopted access for TAVR but various degrees of vascular damage may be induced by the procedure. METHODS: Patients underwent percutaneous transfemoral TAVR who had both pre- and post-TAVR access-site angiography were retrospectively selected. Clinical and procedural data (including technique and complications) were prospectively recorded into a structured TAVR database. Pre-TAVR and post-TAVR angiograms were analyzed using a quantitative angiographic analysis software to assess reference diameters, minimum luminal diameter (MLD), and percentage of diameter stenosis (DS). RESULTS: A total of 124 patients entered the study (mean age: 85 years, mean Euroscore II: 10%). ProStar (13.5%) and double ProGlide (82.2%) preclosure were the main hemostatic techniques. CFA exhibited a significant shrinkage with TAVR as assessed by significant MLD reduction (5.6 mm after TAVR vs. 6.8 mm before, P < .001) and DS increase (30.3% after vs. 17.0%, P < .001). Such differences remained statistically significant after exclusion of 18 patients (14.2%) who had (minor or major) vascular complications. At multivariable analysis, pre-TAVR DS (P = .03) and history of peripheral arterial disease (P = .01), were significantly associated with vascular complications. CONCLUSIONS: Percutaneous TAVR induces an angiographically detectable CFA lumen reduction. Such findings call for further studies assessing clinical impact of this phenomenon and open the door for further refinements of the TAVR access management aimed at preserving vessel integrity.


Asunto(s)
Angiografía de Substracción Digital , Cateterismo Periférico/efectos adversos , Arteria Femoral/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Lesiones del Sistema Vascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Cateterismo Periférico/métodos , Bases de Datos Factuales , Femenino , Arteria Femoral/lesiones , Humanos , Masculino , Valor Predictivo de las Pruebas , Punciones , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología
12.
J Heart Valve Dis ; 26(2): 205-207, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28820551

RESUMEN

Infective endocarditis (IE) is a severe disease with high mortality and morbidity. Prosthetic valve endocarditis is a life-threatening complication which can occur in less than 10% of patients with valve prosthesis. A fungal etiology of IE is rare and accounts for only 2-4% of all case of endocarditis, but is associated with a higher mortality and morbidity. Herein is reported the first case of fungal endocarditis of aortic valve prosthesis due to Aspergillus oryzae in a 67-year-old caucasian man who nine years previously underwent mitral and aortic valve replacement with mechanical prostheses, and tricuspid annuloplasty for acute IE due to Enterococcus spp. Seven months previously, the patient also underwent a redo cardiac procedure to replace a mitral valve prosthesis with a new mechanical device due to a leakage. Aspergillus oryzae showed impressive growth with strong and unexpected virulence in both local and systemic settings.


Asunto(s)
Válvula Aórtica/cirugía , Aspergilosis/microbiología , Aspergillus oryzae/aislamiento & purificación , Endocarditis/microbiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Infecciones Relacionadas con Prótesis/microbiología , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/microbiología , Aspergilosis/diagnóstico , Aspergilosis/cirugía , Aspergillus oryzae/crecimiento & desarrollo , Aspergillus oryzae/patogenicidad , Remoción de Dispositivos , Ecocardiografía Transesofágica , Endocarditis/diagnóstico , Endocarditis/cirugía , Resultado Fatal , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/cirugía , Reoperación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Virulencia
13.
J Heart Valve Dis ; 26(4): 372-379, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-29302935

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Management of patients with aortic regurgitation (AR) and severe impairment of left ventricular (LV) function characterized by an ejection fraction (EF) ≤35% is challenging. Conflicting results regarding perioperative and long-term survival of these patients have been reported. The study aim was to compare in-hospital outcomes and long-term survival of patients with AR and severe LV dysfunction versus moderate dysfunction (35% 70 years and NYHA class III/IV symptoms were predictive of survival. CONCLUSIONS: In-hospital and long-term survival was similar in patients with severe LV dysfunction and with preserved or moderately reduced LV function. Positive reverse LV remodelling and improved LV function was evident at the two-year echocardiographic follow up in these patients, who should not be denied aortic valve surgery.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Ciudad de Roma , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad , Remodelación Ventricular
14.
J Card Surg ; 31(3): 147-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26785697

RESUMEN

We report a patient with situs inversus who developed a large posterior interventricular septum pseudoaneurysm with a septal defect following a myocardial infarction. The ventricular septum was approached through the left ventricle and the entrance of the pseudoaneurysm was repaired with a strip of equine pericardium.


Asunto(s)
Anomalías Múltiples , Procedimientos Quirúrgicos Cardíacos/métodos , Dextrocardia , Defectos del Tabique Interventricular/etiología , Defectos del Tabique Interventricular/cirugía , Infarto del Miocardio/complicaciones , Situs Inversus , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Animales , Aneurisma Cardíaco/etiología , Aneurisma Cardíaco/cirugía , Tabiques Cardíacos/cirugía , Ventrículos Cardíacos/cirugía , Caballos , Humanos , Masculino , Persona de Mediana Edad , Pericardio/trasplante
15.
J Card Surg ; 31(2): 89-95, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26661572

RESUMEN

BACKGROUND: Takotsubo cardiomyopathy syndrome, commonly occurring in postmenopausal women, is characterized by transient apical systolic dysfunction in absence of coronary lesions. The cardiomyopathy is often observed after intense stressful events such as a major surgical procedure. METHODS: A 72-year-old woman symptomatic for dyspnea at rest, chest pain, and peripheral edema successfully underwent surgery for noncoronary sinus aneurysm-right atrium fistula repair. Two days after surgery the patient developed takotsubo syndrome, diagnosed according to the Mayo Clinic criteria. We reviewed the literature on takotsubo cardiomyopathy as a complication of major cardiac surgery procedures. RESULTS: Takotsubo cardiomyopathy is confirmed as a possible early complication of cardiac surgery. Exaggerated sympathetic stimulation may cause massive endogenous catecholamine release. Hypoperfusion during cardiopulmonary bypass, inotropic drugs administration, and postoperative anxiety and pain are all factors generating stress, possible coronary artery spasm and transient cardiomyopathy, clinically simulating acute myocardial infarction. Several clinical features have been described such as acute mitral insufficiency, systolic anterior motion of the anterior mitral valve leaflet, left ventricular outflow tract obstruction, acute cardiac failure, and cardiogenic shock. Intraventricular thrombi and adverse cerebrovascular events may also be possible complications. Rare catastrophic events such as left ventricular free wall rupture and ventricular septal perforation have been also encountered. CONCLUSIONS: After cardiac surgery takotsubo cardiomyopathy should be suspected if clinical and instrumental criteria are met, and promptly differentiated from the more frequent acute myocardial infarction. Prognosis may be favorable if appropriate conservative medical treatment is promptly started.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/terapia , Cardiomiopatía de Takotsubo/diagnóstico , Cardiomiopatía de Takotsubo/terapia , Anciano , Catecolaminas/metabolismo , Diagnóstico Diferencial , Femenino , Fístula/cirugía , Aneurisma Cardíaco/cirugía , Atrios Cardíacos , Cardiopatías/cirugía , Humanos , Complicaciones Posoperatorias/etiología , Pronóstico , Cardiomiopatía de Takotsubo/etiología
16.
Heart Fail Clin ; 10(1 Suppl): S39-45, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24262351

RESUMEN

The authors herein review the rationale and indications for the use of ventricular assistance devices as a bridge to heart transplantation and discuss the current evidence on the subject. The potential effects of device implantation on posttransplant outcomes and the therapeutic strategies in acute and elective cases are revised and illustrated.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Corazón Auxiliar , Insuficiencia Cardíaca/mortalidad , Humanos , Donantes de Tejidos/provisión & distribución , Resultado del Tratamiento
17.
Eur Heart J Cardiovasc Imaging ; 25(3): 425-435, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-37966276

RESUMEN

AIMS: Bicuspid aortic valve (BAV) is a common congenital condition that is frequently associated with aortic stenosis (AS) and aortic regurgitation (AR), as well as aortic aneurysms, but specific outcome data are scarce. The present study sought to assess outcomes in a large cohort of consecutive patients with BAV. METHODS AND RESULTS: A total of 581 consecutive patients (median age 29 years, 157 female) with BAV were included in the study and followed prospectively in a heart valve clinic follow-up programme. The overall survival rate after 10 years was 94.5%. During follow-up, 158 patients developed an indication for surgery. Event-free survival rates were 97%, 94%, 87%, and 73% at 1, 2, 5, and 10 years, respectively. In the multivariable analysis, event rates were independently predicted by AS [subdistribution hazard ratio (SHR) 2.3 per degree of severity], AR (SHR 1.5 per degree of severity), baseline aortic dilatation ≥ 40 mm (SHR 1.9), and age (SHR 1.3) (P < 0.001). CONCLUSION: BAV disease is associated with a high rate of cardiac events, but state-of-the-art care results in good survival with low rates of infective endocarditis, aortic dissection, and sudden death. Incremental degrees of AS and regurgitation, the presence of aortic dilatation, and age are predictive of cardiac events.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Femenino , Adulto , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/complicaciones , Estudios Retrospectivos
18.
Braz J Cardiovasc Surg ; 39(2): e20230159, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38426432

RESUMEN

INTRODUCTION: Obese patients are at risk of complications after cardiac surgery. The aim of this study is to investigate safety and efficacy of a minimally invasive approach via upper sternotomy in this setting. METHODS: We retrospectively reviewed 203 obese patients who underwent isolated, elective aortic valve replacement between January 2014 and January 2023 - 106 with minimally invasive aortic valve replacement (MIAVR) and 97 with conventional aortic valve replacement (CAVR). To account for baseline differences, a propensity-matching analysis was performed obtaining two balanced groups of 91 patients each. RESULTS: The 30-day mortality rate was comparable between groups (1.1% MIAVR vs. 0% CAVR, P=0.99). MIAVR patients had faster extubation than CAVR patients (6 ± 2 vs. 9 ± 2 hours, P<0.01). Continuous positive airway pressure therapy was less common in the MIAVR than in the CAVR group (3.3% vs. 13.2%, P=0.03). Other postoperative complications did not differ significantly. Intensive care unit stay (1.8 ± 1.2 vs. 3.2 ± 1.4 days, P<0.01), but not hospital stay (6.7 ± 2.1 vs. 7.2 ± 1.9 days, P=0.09), was shorter for MIAVR than for CAVR patients. Follow-up survival was comparable (logrank P-value = 0.58). CONCLUSION: MIAVR via upper sternotomy has been shown to be a safe and effective option for obese patients. Respiratory outcome was promising with shorter mechanical ventilation time and reduced need for post-extubation support. The length of stay in the intensive care unit was reduced. These advantages might be important for the obese patient to whom minimally invasive surgery should not be denied.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Válvula Aórtica/cirugía , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Esternotomía/efectos adversos , Obesidad/complicaciones , Obesidad/cirugía , Tiempo de Internación
19.
Int J Cardiol ; 410: 132218, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38815673

RESUMEN

BACKGROUND: The possibility to resheath some transcatheter heart valves (THV) facilitates the optimization of self-expandable devices implantation. However, resheating manoeuvres (expecially when repeated) increase the interaction between the transcatheter prosthesis and the patient's tissues potentially causing side-effects. AIMS: To assess the clinical outcomes of resheathing at midterm follow-up with a focus on the safety of multiple resheathing. METHODS: This retrospective observational study included all consecutive patients who underwent TAVI with a self-expandable supra-annular THV between December 2018 and December 2022. Primary endpoint was a composite of cardiovascular (CV) mortality, neurological events, non-fatal acute myocardial infarction and CV rehospitalizations. All clinical endpoints were assessed according to VARC-3 criteria. RESULTS: 469 TAVI procedures with self-expandable supra-annular THV were included in the study. The attempt to resheath and the resheath manoeuvres number was prospectively recorded into an electronic database. Resheating was attempted in 253 (53.9%) cases; 1, 2 and ≥ 3 resheathing were performed in respectively 122 (26.0%), 63 (13.4%) and 68 (14.5%) procedures. At a median follow-up of 640 days (interquartile range 340-1033 days), the incidence of the primary endpoint did not differ between 0 vs. ≥1 (22.7 vs. 26.1%, LogRank p = 0.584) and < 3 vs. ≥3 resheathing groups (24.2 vs. 26.5% LogRank p = 0.963). Furthermore, no significant differences in the primary endpoint were observed between 0, 1-2 and ≥ 3 resheathing (p = 0.84). CONCLUSIONS: Our study found that resheathing of self-expandable THVs during TAVI did not result in worse clinical outcomes compared with no resheathing at mid-term follow-up. These results are independent from the number of resheathing, underling the safety of multiple resheathing in terms of peri-procedural and mid-term outcome. CONDENSED ABSTRACT: In this retrospective observational study of 469 patients undergoing transcatheter aortic valve implantation (TAVI) for symptomatic severe aortic stenosis with self-expanding valves, we investigated the influence of resheathing on mid-term clinical outcomes. Specifically, we focused on the safety of multiple resheathing procedures. Our findings revealed no significant impact of resheathing on medium-term outcomes. The primary endpoint, a composite of cardiovascular mortality, neurological events, non-fatal acute myocardial infarction, and cardiovascular rehospitalizations, did not show statistically significant differences between no resheathing, single resheathing and multiple resheathing groups. Our study suggests that resheathing, even when performed multiple times, does not appear to significantly affect clinical outcomes at mid-term follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Masculino , Femenino , Estudios Retrospectivos , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estudios de Seguimiento , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
20.
Minerva Cardiol Angiol ; 72(2): 172-181, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38088090

RESUMEN

BACKGROUND: Paravalvular leakage (PVL) is a common finding after transcatheter aortic valve replacement (TAVR) and affects late clinical outcome. It is more frequent with self-expandable (SE) transcatheter-heart-valve (THV). Few is known about SE-THV expansion after implantation. The purpose is to assess SE-THV frame expansion and its possible influence on PVL. METHODS: We designed a prospective pilot study to assess the time-course of SE-THV frame dimensions and PVL after TAVR. Consecutive patients undergoing TAVR with SE-THV were enrolled. Prosthesis fluoroscopy and echocardiography were prospectively performed immediately after TAVR (T0) and before discharge (T1) to grade PVL. Prosthesis diameters were assessed in 2 fluoroscopic orthogonal views. PVL reduction ≥1+ from T0 to T1 at echocardiography was the primary study endpoint. RESULTS: Twenty-five patients were enrolled. Mean interval between T0 and T1 evaluations was 5 days. Grade 1 or 2 was present in 76% of patients at T0 and in 68% at T1 (P=0.034). A total of 7 patients (28%) improved PVL ≥1 grade from T0 to T1. Differences between T0 and T1 fluoroscopic diameters were not statistically significant. When comparing the diameter changes according to PVL evolution, patients with PVL improvement (as compared with those without) had significantly larger minimum diameter increase at both annulus/inflow (P=0.016) and outflow/distal edge (P=0.027). CONCLUSIONS: PVL may improve in the early days after SE-THV and those patients with PVL improvement may have THV frame expansion. Further studies are needed to confirm such preliminary observations and to establish the clinical relevance of this phenomenon.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estudios Prospectivos , Proyectos Piloto , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA