Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Interv Card Electrophysiol ; 45(1): 63-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26552799

RESUMEN

PURPOSE: Previous data showed that pain sensation was common during pulmonary vein isolation (PVI) using an 8-mm radiofrequency (RF) ablation catheter. Pain was more common in the left pulmonary veins (PVs). We characterized the location of pain during PVI using circular multi-electrode ablation catheters. METHODS: Included are all consecutive patients with atrial fibrillation (AF) who underwent PVI using the phased RF PVAC® catheter (Medtronic) or the irrigated nMARQ™ catheter (Biosense Webster) under conscious sedation between July 2011 and March 2015. Site of pain reaction was marked for each patient. RESULTS: A total of 251 patients (141 PVAC®, 110 nMARQ™) were studied; 214 (85 %) had at least one lesion associated with pain. Gender (r = 0.084, p = 0.186), type of AF (r = 0.048, p = 0.452), age (r = 0.078, p = 0.216), and repeat procedure (r = 0.018, p = 0.78) were not correlated with pain. There was no association between site of pain and catheter type; only 33% of the painful PVs were also the largest ones (p = 0.5, kappa = 0.03, R = -0.083). One-year freedom from AF was similar for patients with and without painful PVs (p = 0.6). The distribution of pain was as follows: 126 (59%) left superior PV (LSPV), 28 (13%) left inferior, 28 (13%) all PVs, 12 (5.6%) right superior, 12 (5.6%) right inferior, 18 (8.4%) left common, and 2 (0.9%) right common PV. CONCLUSIONS: PVI using multi-electrode catheters more commonly caused pain sensation in LSPV. There was no influence of catheter type or PV size on pain localization. Our findings, which are similar to those using an 8-mm ablation catheter, imply that location of pain is not catheter dependent but rather a reflection of autonomic physiology.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/epidemiología , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Ablación por Catéter/métodos , Ablación por Catéter/estadística & datos numéricos , Causalidad , Sedación Consciente , Electrodos/estadística & datos numéricos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Israel/epidemiología , Masculino , Persona de Mediana Edad , Dimensión del Dolor/métodos , Dimensión del Dolor/estadística & datos numéricos , Dolor Postoperatorio/clasificación , Prevalencia , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA