Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Ann Rheum Dis ; 81(2): 232-236, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34407928

RESUMEN

OBJECTIVES: This study aimed to determine the prevalence of ultrasound-detected tendon abnormalities in healthy subjects (HS) across the age range. METHODS: Adult HS (age 18-80 years) were recruited in 23 international Outcome Measures in Rheumatology ultrasound centres and were clinically assessed to exclude inflammatory diseases or overt osteoarthritis before undergoing a bilateral ultrasound examination of digit flexors (DFs) 1-5 and extensor carpi ulnaris (ECU) tendons to detect the presence of tenosynovial hypertrophy (TSH), tenosynovial power Doppler (TPD) and tenosynovial effusion (TEF), usually considered ultrasound signs of inflammatory diseases. A comparison cohort of patients with rheumatoid arthritis (RA) was taken from the Birmingham Early Arthritis early arthritis inception cohort. RESULTS: 939 HS and 144 patients with RA were included. The majority of HS (85%) had grade 0 for TSH, TPD and TEF in all DF and ECU tendons examined. There was a statistically significant difference in the proportion of TSH and TPD involvement between HS and subjects with RA (HS vs RA p<0.001). In HS, there was no difference in the presence of ultrasound abnormalities between age groups. CONCLUSIONS: Ultrasound-detected TSH and TPD abnormalities are rare in HS and can be regarded as markers of active inflammatory disease, especially in newly presenting RA.


Asunto(s)
Tendones/diagnóstico por imagen , Tendones/patología , Tenosinovitis/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Voluntarios Sanos , Humanos , Hipertrofia/diagnóstico por imagen , Hipertrofia/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Tenosinovitis/diagnóstico por imagen , Ultrasonografía , Adulto Joven
2.
Z Rheumatol ; 81(9): 787-791, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36018373

RESUMEN

Henrik Sjögren was a Swedish ophthalmologist who wrote a dissertation (in German) consisting of a 131-page long monograph on patients who exhibited a constellation of keratitis sicca, xerostomia and arthritis. This article highlights several key moments of his life and work leading to the delineation of a new syndrome.


Asunto(s)
Queratoconjuntivitis Seca , Síndrome de Sjögren , Xerostomía , Humanos , Síndrome de Sjögren/diagnóstico
3.
Ann Rheum Dis ; 80(2): 261-267, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32988839

RESUMEN

OBJECTIVE: To evaluate the discriminatory ability of ultrasound in calcium pyrophosphate deposition disease (CPPD), using microscopic analysis of menisci and knee hyaline cartilage (HC) as reference standard. METHODS: Consecutive patients scheduled for knee replacement surgery, due to osteoarthritis (OA), were enrolled. Each patient underwent ultrasound examination of the menisci and HC of the knee, scoring each site for presence/absence of CPPD. Ultrasound signs of inflammation (effusion, synovial proliferation and power Doppler) were assessed semiquantitatively (0-3). The menisci and condyles, retrieved during surgery, were examined microscopically by optical light microscopy and by compensated polarised microscopy. CPPs were scored as present/absent in six different samples from the surface and from the internal part of menisci and cartilage. Ultrasound and microscopic analysis were performed by different operators, blinded to each other's findings. RESULTS: 11 researchers from seven countries participated in the study. Of 101 enrolled patients, 68 were included in the analysis. In 38 patients, the surgical specimens were insufficient. The overall diagnostic accuracy of ultrasound for CPPD was of 75%-sensitivity of 91% (range 71%-87% in single sites) and specificity of 59% (range 68%-92%). The best sensitivity and specificity were obtained by assessing in combination by ultrasound the medial meniscus and the medial condyle HC (88% and 76%, respectively). No differences were found between patients with and without CPPD regarding ultrasound signs of inflammation. CONCLUSION: Ultrasound demonstrated to be an accurate tool for discriminating CPPD. No differences were found between patents with OA alone and CPPD plus OA regarding inflammation.


Asunto(s)
Condrocalcinosis/diagnóstico por imagen , Cartílago Hialino/diagnóstico por imagen , Menisco/diagnóstico por imagen , Osteoartritis de la Rodilla/diagnóstico por imagen , Ultrasonografía/estadística & datos numéricos , Anciano , Artroplastia de Reemplazo de Rodilla , Pirofosfato de Calcio/análisis , Femenino , Humanos , Cartílago Hialino/patología , Masculino , Menisco/patología , Microscopía/métodos , Microscopía/estadística & datos numéricos , Persona de Mediana Edad , Osteoartritis de la Rodilla/patología , Osteoartritis de la Rodilla/cirugía , Periodo Preoperatorio , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Ann Rheum Dis ; 78(7): 967-973, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31036626

RESUMEN

OBJECTIVE: To develop ultrasound (US) definitions and a US novel scoring system for major salivary gland (SG) lesions in patients with primary Sjögren's syndrome (pSS) and to test their intrareader and inter-reader reliability using US video clips. METHODS: Twenty-five rheumatologists were subjected to a three-round, web-based Delphi process in order to agree on (1) definitions and scanning procedure of salivary gland ultrasonography (SGUS): parotid, submandibular and sublingual glands (PG, SMG and SLG); (2) definitions for the elementary SGUS lesions in patients with Sjögren's syndrome; (3) scoring system for grading changes. The experts rated the statements on a 1-5 Likert scale. In the second step, SGUS video clips of patients with pSS and non-pSS sicca cases were collected containing various spectrums of disease severity followed by an intrareader and inter-reader reliability exercise. Each video clip was evaluated according to the agreed definitions. RESULTS: Consensual definitions were developed after three Delphi rounds. Among the three selected SGs, US assessment of PGs and SMGs was agreed on. Agreement was reached to score only greyscale lesions and to focus on anechoic/hypoechoic foci in a semiquantitative matter or, if not possible on a qualitatively (present/absent) evaluation of fatty or fibrous lesions. Intrareader reliability for detecting and scoring these lesions was excellent (Cohen's kappa 0.81) and inter-reader reliability was good (Light's kappa 0.66). CONCLUSION: New definitions for developing a novel semiquantitative US score in patients with pSS were developed and tested on video clips. Inter-reader and intrareader reliabilities were good and excellent, respectively.


Asunto(s)
Interpretación de Imagen Asistida por Computador/normas , Glándulas Salivales/diagnóstico por imagen , Síndrome de Sjögren/diagnóstico por imagen , Ultrasonografía/normas , Consenso , Técnica Delphi , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía/métodos
5.
Ann Rheum Dis ; 75(5): 842-6, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-25902788

RESUMEN

OBJECTIVE: To assess whether ultrasonography (US) is reliable for the evaluation of inflammatory and structural abnormalities in patients with knee osteoarthritis (OA). METHODS: Thirteen patients with early knee OA were examined by 11 experienced sonographers during 2 days. Dichotomous and semiquantitative scoring was performed on synovitis characteristics in various aspects of the knee joint. Semiquantitative scoring was done of osteophytes at the medial and lateral femorotibial joint space or cartilage damage of the trochlea and on medial meniscal damage bilaterally. Intra- and interobserver reliability were computed by use of unweighted and weighted κ coefficients. RESULTS: Intra- and interobserver reliability scores were moderate to good for synovitis (mean κ 0.67 and 0.52, respectively) as well as moderate to good for the global synovitis (0.70 and 0.50, respectively). Mean intra- and interobserver reliability κ for cartilage damage, medial meniscal damage and osteophytes ranged from fair to good (0.55 and 0.34, 0.75 and 0.56, 0.73 and 0.60, respectively). CONCLUSIONS: Using a standardised protocol, dichotomous and semiquantitative US scoring of pathological changes in knee OA can be reliable.


Asunto(s)
Osteoartritis de la Rodilla/diagnóstico por imagen , Anciano , Cartílago Articular/diagnóstico por imagen , Técnica Delphi , Femenino , Humanos , Masculino , Meniscos Tibiales/diagnóstico por imagen , Persona de Mediana Edad , Variaciones Dependientes del Observador , Osteofito/diagnóstico por imagen , Reproducibilidad de los Resultados , Membrana Sinovial/diagnóstico por imagen , Sinovitis/diagnóstico por imagen , Ultrasonografía Doppler/métodos
6.
Semin Arthritis Rheum ; 65: 152378, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38310657

RESUMEN

Sjögren's disease (SjD) is a systemic autoimmune exocrinopathy with key features of dryness, pain, and fatigue. SjD can affect any organ system with a variety of presentations across individuals. This heterogeneity is one of the major barriers for developing effective disease modifying treatments. Defining core disease domains comprising both specific clinical features and incorporating the patient experience is a critical first step to define this complex disease. The OMERACT SjD Working Group held its first international collaborative hybrid meeting in 2023, applying the OMERACT 2.2 filter toward identification of core domains. We accomplished our first goal, a scoping literature review that was presented at the Special Interest Group held in May 2023. Building on the domains identified in the scoping review, we uniquely deployed multidisciplinary experts as part of our collaborative team to generate a provisional domain list that captures SjD heterogeneity.


Asunto(s)
Síndrome de Sjögren , Humanos , Resultado del Tratamiento , Síndrome de Sjögren/terapia , Dolor , Fatiga
7.
Semin Arthritis Rheum ; 51(3): 644-649, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33468347

RESUMEN

OBJECTIVE: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0-3) for tophus, double contour and aggregates. Furthermore, the intra- and inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. METHODS: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. RESULTS: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (κ-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (κ-values 0.74-0.80) than inter-reader reliabilities (κ-values 0.61-0.67). CONCLUSION: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was developed with good inter- and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients.


Asunto(s)
Gota , Consenso , Ejercicio Físico , Gota/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA