Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(6): 1431-1440, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36786511

RESUMEN

INTRODUCTION: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration. METHODS: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms. RESULTS: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg). CONCLUSION: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Terapia de Resincronización Cardíaca/efectos adversos , Hemodinámica/fisiología , Bloqueo de Rama , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Función Ventricular Izquierda/fisiología , Estimulación Cardíaca Artificial
2.
Cardiol Young ; 20(3): 337-8, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20346201

RESUMEN

INTRODUCTION: Patients with complex congenital cardiac disease are increasingly surviving to adulthood and many are keen to consider pregnancy. Haemodynamic status should be optimal prior to embarking on pregnancy and for some this may mean surgical intervention to alleviate haemodynamic residua. METHODS: We report the successful implantation of a percutaneous pulmonary stent valve into a right atrial to right ventricular conduit in a young woman with a Bjork modification of the Fontan palliation to improve haemodynamics prior pregnancy. DISCUSSION: Catheter interventions offer a low-risk option for the treatment of haemodynamic residua and innovative use of new technologies such as the pulmonary stent valve presents a novel, safe, and effective treatment for such conduit problems.


Asunto(s)
Procedimiento de Fontan/métodos , Complicaciones Cardiovasculares del Embarazo/prevención & control , Obstrucción del Flujo Ventricular Externo/cirugía , Angiografía Coronaria , Diagnóstico Diferencial , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Embarazo , Obstrucción del Flujo Ventricular Externo/diagnóstico , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA