RESUMEN
PURPOSE: The Italian Association of Medical Physics (AIFM) started a working group dedicated to stereotactic body radiotherapy (SBRT) treatment. In this work, we performed a multicenter planning study on patients who were candidates for SBRT in the treatment of prostate cancer with the aim of evaluating the dosimetric consistency among the different hospitals. METHODS AND MATERIALS: Fourteen centers were provided the contours of 5 patients. Plans were performed following the dose prescription and constraints for organs at risk (OARs) of a reference paper. The dose prescription was 35 Gy in five fractions for the planning target volume (PTV). Different techniques were used (3D-CRT, fixed-Field IMRT, VMAT, CyberKnife). Plans were compared in terms of dose-volume histogram (DVH) parameters. Furthermore, the median DVH was calculated and one patient was re-planned. RESULTS: A total of 70 plans were compared. The maximum dose to the body was 107.9 ± 4.5 % (range 101.5-116.3 %). Dose at 98 % (D98 %) and mean dose to the clinical target volume (CTV) were 102.0 ± 0.9 % (global range 101.1-102.9 %) and 105.1 ± 0.6 % (range 98.6-124.6 %). Similar trends were found for D95 % and mean dose to the PTV. Important differences were found in terms of the homogeneity index. Doses to OARs were heterogeneous. The subgroups with the same treatment planning system showed differences comparable to the differences of the whole group. In the re-optimized plans, DVH differences among institutes were reduced and OAR sparing improved. CONCLUSION: Important dosimetric differences with possible clinical implications, in particular related to OARs, were found. Replanning allowed a reduction in the OAR dose and decreased standard deviations. Multicenter clinical trials on SBRT should require a preplanning study to standardize the optimization procedure.
Asunto(s)
Neoplasias de la Próstata/cirugía , Radiocirugia/métodos , Anciano , Estudios de Factibilidad , Humanos , Italia , Masculino , Persona de Mediana Edad , Órganos en Riesgo , Planificación de Atención al Paciente , Posicionamiento del Paciente , Cuidados Preoperatorios , Radiometría/métodosRESUMEN
BACKGROUND: Set-up errors represent a source of uncertainty in head and neck (H&N) cancer radiotherapy. The present study evaluated set-up accuracy with the use of cone-beam computed tomography (CBCT) in order to establish the proper clinical target volume (CTV) to planning target volume (PTV) margins to be adopted. METHODS: Local set-up accuracy was analysed for 44 H&N cancer patients since the implementation of CBCT. An on-line correction protocol was adopted, with the first 3 scans used to correct systematic errors with a 3-mm action level. The overall mean displacement (M), the population systematic (Σ) and random (σ) errors and the 3D vector length were calculated. PTV margins were calculated according to the van Herk formula (2.5Σ + 0.7σ). RESULTS: A total of 420 CBCT scans were analysed. A systematic correction was needed in 43% of patients. The value of M was <1 mm in all directions; the values of Σ and σ ranged over 1-1.2 and 1.4-1.9 mm, respectively. Pre-correction PTV margins were 3.48, 4.08 and 4.33 mm along the 3 axes. The PTV margins calculated after online correction were <2.5 mm in all directions. CONCLUSIONS: Kilovoltage CBCT is effective in evaluating set-up accuracy in H&N patients. CTV-PTV margins of 5 mm are safe and are currently adopted at our centre; however, some special situations, such as re-irradiation or the close proximity of organs at risk and high-dose regions, could benefit from daily image registration and lower (i.e., 3 mm) margins.
Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Anciano , Anciano de 80 o más Años , Femenino , Neoplasias de Cabeza y Cuello/patología , Humanos , Masculino , Persona de Mediana Edad , Sistemas en Línea , Dosificación RadioterapéuticaRESUMEN
OBJECTIVE: To outline a practical method of performing prostate cancer radiotherapy in patients with bilateral metal hip prostheses with the standard resources available in a modern general hospital. The proposed workflow is based exclusively on magnetic resonance imaging (MRI) to avoid computed tomography (CT) artifacts. CASE DESCRIPTION: This study concerns a 73-year-old man with bilateral hip prostheses with an elevated risk prostate cancer. Magnetic resonance images with assigned electron densities were used for planning purposes, generating a synthetic CT (sCT). Imaging acquisition was performed with an optimized Dixon sequence on a 1.5T MRI scanner. The images were contoured by autosegmentation software, based on an MRI database of 20 patients. The sCT was generated assigning averaged electron densities to each contour. Two volumetric modulated arc therapy plans, a complete arc and a partial one, where the beam entrances through the prostheses were avoided for about 50° on both sides, were compared. The feasibility of matching daily cone beam CT (CBCT) with MRI reference images was also tested by visual evaluations of different radiation oncologists. CONCLUSIONS: The use of magnetic resonance images improved accuracy in targets and organs at risk (OARs) contouring. The complete arc plan was chosen because of 10% lower mean and maximum doses to prostheses with the same planning target volume coverage and OAR sparing. The image quality of the match between performed CBCTs and MRI was considered acceptable. The proposed method seems promising to improve radiotherapy treatments for this complex category of patients.
Asunto(s)
Radioterapia de Iones Pesados/normas , Prótesis de Cadera/estadística & datos numéricos , Imagen por Resonancia Magnética/métodos , Prótesis Articulares de Metal sobre Metal/estadística & datos numéricos , Neoplasias de la Próstata/patología , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia Guiada por Imagen/métodos , Anciano , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Órganos en Riesgo , Neoplasias de la Próstata/radioterapiaRESUMEN
PURPOSE: Stereotactic body radiation therapy (SBRT) for early stage solid tumors and metastases is increasing worldwide. In 2013, the Italian Association of Medical Physicists (AIFM) created a working group in order to standardize the SBRT dosimetric aspects (AIFM/SBRT-WG). The aim of this study was to investigate the current status of technology and quality assurance (QA) as regards SBRT in Italy. Clinical evaluation of SBRT was beyond the scope of the present study. METHODS: A pre-questionnaire was designed by three medical physicists expert in SBRT. It contained questions on 4 main aspects: technology, image-guidance solutions (IGRT), treatment planning system commissioning and QA. In early 2018, all the centers involved in the AIFM/SBRT-WG were invited to complete the online questionnaire. RESULTS: The survey was undertaken by 45 centres (83% of them involved in the AIFM/SBRT-WG). The most available delivery system was conventional linacs with VMAT modality; 6MV and 6MV-FFF were the most common energies; robotic couch was available in 56% of centers; CBCT/MVCT was the most used IGRT technique (58% of centers) and 40% of centers adopted respiratory management during treatment delivery. The smallest measured field size for lateral beam profiles was ≤1â¯×â¯1â¯cm2 in 79% of linac-based centers. Great heterogeneity in terms of protocols and guidelines for QA were found. A large number of centers (51%) felt the need to upgrade their dosimetric QA devices dedicated to SBRT. CONCLUSION: This survey on SBRT is a starting point in standardizing the dosimetry of SBRT verification and to improve the QA procedure.
Asunto(s)
Radiocirugia/estadística & datos numéricos , Encuestas y Cuestionarios , Humanos , Control de Calidad , Radiometría/normas , Radiocirugia/normas , Planificación de la Radioterapia Asistida por Computador , Estándares de ReferenciaRESUMEN
PURPOSE: The aim was to calibrate gamma cameras in the framework of the Italian multicentre study for lesion dosimetry in 223Ra therapy of bone metastases. Equipments of several manufacturers and different models were used. METHODS: Eleven gamma cameras (3/8- and 5/8-inch crystal) were used, acquiring planar static images with double-peak (82 and 154keV, 20% wide) and MEGP collimator. The sensitivity was measured in air, varying source-detector distance and source size. Transmission curves were measured, calculating the parameters used for attenuation/scatter correction with the pseudo-extrapolation number method, and assessing their variations with the source size. RESULTS: Values of the calibration factor (geometric mean of both detector sensitivities) ranged from 41.1 to 113.9cps/MBq. For the smallest source (diameter of 3.5cm), the calibration factor decrease ranged from -30% to -4%, highlighting the importance of partial volume effects according to the equipment involved. The sensitivity variation with the source-detector distance, with respect to the 15cm-value, reached 10% (in absolute value) in the range 5-30cm, but fixing the distance between the two heads, the calibration factor variation with the distance from the midline was within 3.6%. Appreciable variation of the transmission curves with the source size were observed, examining the results obtained with six gamma cameras. CONCLUSION: Assessments of sensitivity and transmission curve variations with source size should be regularly implemented in calibration procedures. The results of this study represent a useful compendium to check the obtained calibrations for dosimetric purposes.
Asunto(s)
Neoplasias Óseas/radioterapia , Cámaras gamma , Radiometría/normas , Calibración , Humanos , ItaliaRESUMEN
PURPOSE: To compare five liver metastasis stereotactic ablative radiotherapy (SABR) plans optimised in fourteen centres with 3D-Conformal-RT, IMRT, VMAT, CyberKnife and Tomotherapy and identify possible dosimetric differences. METHODS: Dose prescription was 75 Gy in 3 fractions, normalised at 67%-95% isodose. RESULTS: Excluding few cases, all institutions achieved the planning objectives. Differences up to 40% and 25% in mean dose to liver and PTV were found. No significant correlations between technological factors and DVH for target and OARs were observed; the optimisation strategies selected by the planners played a key role in the planning procedure. CONCLUSIONS: The human factor and the constraints imposed to the target volume have a greater dosimetric impact than treatment planning and radiation delivery technology in stereotactic treatment of liver metastases. Significant differences found both in terms of dosimetric target coverage and OAR sparing should be taken into consideration before starting a multi-institutional SARB clinical trial.
Asunto(s)
Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirugía , Radiocirugia/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/métodos , Simulación por Computador , Bases de Datos Factuales , Tomografía Computarizada Cuatridimensional/métodos , Humanos , Italia , Metástasis de la Neoplasia , Órganos en Riesgo , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Resultado del TratamientoRESUMEN
PURPOSE: A large-scale multi-institutional planning comparison on lung cancer SABR is presented with the aim of investigating possible criticism in carrying out retrospective multicentre data analysis from a dosimetric perspective. METHODS: Five CT series were sent to the participants. The dose prescription to PTV was 54Gy in 3 fractions of 18Gy. The plans were compared in terms of PTV-gEUD2 (generalized Equivalent Uniform Dose equivalent to 2Gy), mean dose to PTV, Homogeneity Index (PTV-HI), Conformity Index (PTV-CI) and Gradient Index (PTV-GI). We calculated the maximum dose for each OAR (organ at risk) considered as well as the MLD2 (mean lung dose equivalent to 2Gy). The data were stratified according to expertise and technology. RESULTS: Twenty-six centers equipped with Linacs, 3DCRT (4% - 1 center), static IMRT (8% - 2 centers), VMAT (76% - 20 centers), CyberKnife (4% - 1 center), and Tomotherapy (8% - 2 centers) collaborated. Significant PTV-gEUD2 differences were observed (range: 105-161Gy); mean-PTV dose, PTV-HI, PTV-CI, and PTV-GI were, respectively, 56.8±3.4Gy, 14.2±10.1%, 0.70±0.15, and 4.9±1.9. Significant correlations for PTV-gEUD2 versus PTV-HI, and MLD2 versus PTV-GI, were observed. CONCLUSIONS: The differences in terms of PTV-gEUD2 may suggest the inclusion of PTV-gEUD2 calculation for retrospective data inter-comparison.