Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Ultrasound Obstet Gynecol ; 63(6): 789-797, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38354177

RESUMEN

OBJECTIVE: To evaluate longitudinal changes in cervical length (CL) and mean cervical shear wave elastography (CSWE) score in women with a singleton or twin pregnancy who undergo spontaneous preterm birth (sPTB) compared with those who deliver at term. METHODS: This was a prospective longitudinal study of unselected women with a singleton or twin pregnancy attending a dedicated research clinic for screening for sPTB at four timepoints during pregnancy: 11 + 0 to 15 + 6 weeks, 16 + 0 to 20 + 6 weeks, 21 + 0 to 24 + 6 weeks and 28 + 0 to 32 + 6 weeks. At each visit, a transvaginal ultrasound scan was conducted to measure the CL and the CSWE scores in six regions of interest (ROI) (inner, middle and external parts of anterior and posterior cervical lips). The mean CSWE score from the six ROIs was calculated for analysis. Log10 transformation was applied to data to produce a Gaussian distribution prior to statistical analysis. A multilevel mixed-effects analysis was performed to compare longitudinally CL and CSWE between the sPTB and term-delivery groups. RESULTS: The final cohort consisted of 1264 women, including 1143 singleton pregnancies, of which 57 (5.0%) were complicated by sPTB, and 121 twin pregnancies, of which 33 (27.3%) were complicated by sPTB. Compared to those who delivered at term, women with sPTB had a lower CL across gestation when controlling for history of cervical surgery, number of fetuses, gestational age (GA) at cervical assessment and the interaction between GA at cervical assessment and sPTB (P < 0.001). Specifically, CL in the sPTB group was significantly lower at 21 + 0 to 24 + 6 weeks (P = 0.039) and 28 + 0 to 32 + 6 weeks (P < 0.001). Twin pregnancies had significantly greater CL throughout pregnancy compared with singleton pregnancies (regression coefficient, 0.01864; P < 0.001). After adjusting for maternal age, weight, height, body mass index and GA at cervical assessment, CSWE score in the sPTB group was significantly lower compared with that in the term-delivery group across gestation (P = 0.013). However, on analysis of individual visits, CSWE score in the sPTB group was significantly lower than that in the term-delivery group only at 11 + 0 to 15 + 6 weeks (P = 0.036). There was no difference in CSWE score between singleton and twin pregnancies throughout gestation (regression coefficient, -0.00128; P = 0.937). CONCLUSIONS: Women with sPTB have a shorter and softer cervix across gestation compared with those who deliver at term. A shorter cervix in the sPTB group is observed from the late second trimester onwards, while lower cervical stiffness in the sPTB group is observed primarily in the first trimester. CL is significantly lower in singleton pregnancies compared with twin pregnancies, while cervical stiffness does not differ between the two. Our findings indicate that the cervix tends to undergo a softening process prior to shortening in sPTB cases. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Medición de Longitud Cervical , Cuello del Útero , Diagnóstico por Imagen de Elasticidad , Embarazo Gemelar , Nacimiento Prematuro , Humanos , Femenino , Embarazo , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Longitudinales , Estudios Prospectivos , Adulto , Cuello del Útero/diagnóstico por imagen , Medición de Longitud Cervical/métodos , Edad Gestacional , Ultrasonografía Prenatal/métodos , Ultrasonografía Prenatal/estadística & datos numéricos
2.
Ultrasound Obstet Gynecol ; 60(2): 200-206, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35468236

RESUMEN

OBJECTIVE: To assess whether pregnancy-associated plasma protein-A (PAPP-A) alters or provides equivalent screening performance as placental growth factor (PlGF) when screening for preterm pre-eclampsia (PE) at 11-13 weeks of gestation. METHODS: This was a secondary analysis of a non-intervention screening study of 6546 singleton pregnancies that were screened prospectively for preterm PE in the first trimester between December 2016 and June 2018. Patient-specific risks for preterm PE were estimated by maternal history, mean arterial pressure (MAP), uterine artery pulsatility index (UtA-PI), PlGF and PAPP-A. A competing-risks model with biomarkers expressed as multiples of the median was used. All women and clinicians were blinded to the risk for preterm PE. The performance of screening for preterm PE using PlGF vs PAPP-A vs both PAPP-A and PlGF was assessed by comparing areas under the receiver-operating-characteristics (AUC) curves. McNemar's test was used to compare detection rate at a fixed false-positive rate (FPR) of 10%. RESULTS: PlGF and PAPP-A were measured in 6546 women, of whom 37 developed preterm PE. The AUC and detection rate at 10% FPR using PlGF in combination with maternal history, MAP and UtA-PI were 0.854 and 59.46%, respectively. The respective values were 0.813 and 51.35% when replacing PlGF with PAPP-A and 0.855 and 59.46% when using both PAPP-A and PlGF. Statistically non-significant differences were noted in AUC when replacing PlGF with PAPP-A (ΔAUC, 0.04; P = 0.095) and when using both PAPP-A and PlGF (ΔAUC, 0.002; P = 0.423). However, on an individual case basis, screening using PlGF in conjunction with maternal history, MAP and UtA-PI identified three (8.1%) additional pregnancies that developed preterm PE and that were not identified when replacing PlGF with PAPP-A. Screening using PAPP-A in addition to maternal history and other biomarkers did not identify any additional pregnancies. CONCLUSION: On an individual case basis, adoption of a screening strategy that uses PAPP-A instead of PlGF results in reduced detection of preterm PE, consistent with previous literature. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Preeclampsia , Proteína Plasmática A Asociada al Embarazo , Biomarcadores , Femenino , Humanos , Recién Nacido , Factor de Crecimiento Placentario , Embarazo , Primer Trimestre del Embarazo , Flujo Pulsátil , Arteria Uterina/diagnóstico por imagen
3.
Ultrasound Obstet Gynecol ; 60(2): 192-199, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35445767

RESUMEN

OBJECTIVES: To determine whether first-trimester biomarkers of placental function can be used to screen for spontaneous preterm birth (sPTB), and to develop prediction models using maternal factors, obstetric history and biomarkers of placental function at 11-13 weeks for the calculation of patient-specific risk for sPTB. METHODS: This was a retrospective secondary analysis of data derived from a prospective cohort study on first-trimester screening for pre-eclampsia in singleton pregnancies attending for routine Down syndrome screening at 11 + 0 to 13 + 6 weeks' gestation at a tertiary obstetric unit between December 2016 and September 2019. A split-sample internal validation method was used to explore and develop prediction models for all sPTB at < 37 weeks and for PTB at < 37 weeks after preterm prelabor rupture of membranes (PPROM) using maternal risk factors, uterine artery Doppler indices, serum placental growth factor (PlGF), pregnancy-associated plasma protein-A (PAPP-A) and ß-human chorionic gonadotropin (ß-hCG). Screening performance was assessed using receiver-operating-characteristics (ROC)-curve analysis, with calculation of the areas under the ROC curves (AUCs). RESULTS: A total of 9298 singleton pregnancies were included in this study. sPTB at < 37 weeks occurred in 362 (3.89%) cases, including 231 (2.48%) cases of PPROM. sPTB at < 34 weeks occurred in 87 (0.94%) cases, including 39 (0.42%) cases of PPROM. Identified maternal risk factors for sPTB at < 37 weeks included chronic hypertension, conception using in-vitro fertilization and history of PTB. Maternal risk factors for PPROM at < 37 weeks included conception using in-vitro fertilization and history of PTB. Median PlGF multiples of the median (MoM) and PAPP-A MoM were significantly reduced in women with sPTB at < 37 weeks, as well as in those who had PPROM, compared to those who delivered at term. Screening by a combination of maternal risk factors, PAPP-A and PlGF achieved better performance in predicting sPTB at < 37 weeks (AUC, 0.630 vs 0.555; detection rate (DR), 24.8% vs 16.6% at a false-positive rate (FPR) of 10%; P ≤ 0.0001) and PPROM at < 37 weeks (AUC, 0.643 vs 0.558; DR, 28.1% vs 17.0% at a FPR of 10%; P ≤ 0.0001) than using maternal risk factors alone. Both models were successfully applied to the internal validation dataset, with AUCs of 0.628 and 0.650, respectively. CONCLUSIONS: We demonstrated that low levels of maternal serum PAPP-A and PlGF in the first trimester are associated with increased risks of sPTB and PPROM at < 37 weeks. However, further research is needed to identify additional biomarkers to improve the screening performance of the combined model that includes maternal risk factors, PAPP-A and PlGF before clinical application. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Preeclampsia , Nacimiento Prematuro , Biomarcadores , Femenino , Rotura Prematura de Membranas Fetales , Humanos , Recién Nacido , Placenta/metabolismo , Factor de Crecimiento Placentario , Preeclampsia/diagnóstico , Embarazo , Primer Trimestre del Embarazo , Proteína Plasmática A Asociada al Embarazo/metabolismo , Nacimiento Prematuro/diagnóstico , Estudios Prospectivos , Estudios Retrospectivos , Arteria Uterina/diagnóstico por imagen
4.
Ultrasound Obstet Gynecol ; 58(4): 603-608, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33219729

RESUMEN

OBJECTIVE: To assess objectively the degree of fetal head elevation achieved by different maneuvers commonly used for managing umbilical cord prolapse. METHODS: This was a prospective observational study of pregnant women at term before elective Cesarean delivery. A baseline assessment of fetal head station was performed with the woman in the supine position, using transperineal ultrasound for measuring the parasagittal angle of progression (psAOP), head-symphysis distance (HSD) and head-perineum distance (HPD). The ultrasonographic measurements of fetal head station were repeated during different maneuvers, including elevation of the maternal buttocks using a wedge, knee-chest position, Trendelenburg position with a 15° tilt and filling the maternal urinary bladder with 100 mL, 300 mL and 500 mL of normal saline. The measurements obtained during the maneuvers were compared with the baseline measurements. RESULTS: Twenty pregnant women scheduled for elective Cesarean section at term were included in the study. When compared with baseline (median psAOP, 103.6°), the knee-chest position gave the strongest elevation effect, with the greatest reduction in psAOP (psAOP, 80.7°; P < 0.001), followed by filling the bladder with 500 mL (psAOP, 89.9°; P < 0.001) and 300 mL (psAOP, 94.4°; P < 0.001) of normal saline. Filling the maternal bladder with 100 mL of normal saline (psAOP, 96.1°; P = 0.001), the Trendelenburg position (psAOP, 96.8°; P = 0.014) and elevating the maternal buttocks (psAOP, 98.3°; P = 0.033) gave modest elevation effects. Similar findings were reported for HSD and HPD. The fetal head elevation effects of the knee-chest position, Trendelenburg position and elevation of the maternal buttocks were independent of the initial fetal head station, but that of bladder filling was greater when the initial head station was low. CONCLUSIONS: To elevate the fetal presenting part, the knee-chest position provides the best effect, followed by filling the maternal urinary bladder with 500 mL then 300 mL of fluid, respectively. Filling the bladder with 100 mL of fluid, the Trendelenburg position and elevation of the maternal buttocks have modest effects. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Feto/diagnóstico por imagen , Cabeza/embriología , Presentación en Trabajo de Parto , Posicionamiento del Paciente/métodos , Ultrasonografía Prenatal/métodos , Adulto , Cesárea , Femenino , Feto/embriología , Humanos , Perineo/diagnóstico por imagen , Embarazo , Periodo Preoperatorio , Prolapso , Estudios Prospectivos , Nacimiento a Término/fisiología , Cordón Umbilical
5.
Ultrasound Obstet Gynecol ; 58(2): 214-220, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32730679

RESUMEN

OBJECTIVE: To investigate whether gestational age at intervention (< or ≥ 16 weeks) and other factors affect the risk of loss of the cotwin after selective fetal reduction using radiofrequency ablation (RFA) in monochorionic (MC) pregnancy. METHODS: This was a single-center retrospective analysis of 63 consecutive RFA procedures performed at our institution from January 2011 to October 2019 for selective fetal reduction in complicated MC pregnancies. Indications for RFA were twin reversed arterial perfusion sequence (13 cases), twin-to-twin transfusion syndrome (12 cases), twin anemia-polycythemia sequence (two cases), selective fetal growth restriction (10 cases), discordant anomalies (17 cases) and multifetal pregnancy reduction in triplets or quadruplets with a MC pair (nine cases). Twenty-six (41.3%) of these procedures were performed before and 37 (58.7%) after 16 weeks. Potential factors that could affect the risk of loss of the cotwin, including gestational age at RFA, order of multiple pregnancy, amnionicity, indication for RFA and number of ablation cycles, were assessed first by univariate analysis and then by multivariate analysis. RESULTS: There were 17 (27.0%) cotwin losses. Ablation cycles numbering four or more was the only factor among those investigated to be associated with loss of the cotwin after RFA (P = 0.035; odds ratio, 5.21), while the indication for RFA, order of multiple pregnancy, amnionicity and gestational age at RFA had no effect. Comparing RFA performed at < 16 vs ≥ 16 weeks, there was no difference in the rate of cotwin loss (23.1% vs 29.7%; P = 0.558) or preterm prelabor rupture of the membranes before 34 weeks (7.7% vs 5.4%; P = 0.853), or in the median gestational age at delivery (36.2 vs 37.3 weeks; P = 0.706). CONCLUSIONS: RFA is a promising tool for early selective fetal reduction in MC pregnancy before 16 weeks. Four or more ablation cycles is a major risk factor for cotwin loss. Careful assessment pre- and post-RFA, together with proficient operative skills to minimize the number of ablation cycles, are the mainstay to ensure that this procedure is effective and safe. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Reducción de Embarazo Multifetal , Embarazo Múltiple , Adulto , Femenino , Edad Gestacional , Humanos , Recién Nacido , Complicaciones Posoperatorias , Embarazo , Resultado del Embarazo , Trimestres del Embarazo , Ablación por Radiofrecuencia , Estudios Retrospectivos
6.
Ultrasound Obstet Gynecol ; 56(2): 206-214, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31671479

RESUMEN

OBJECTIVES: To (i) evaluate the applicability of the European-derived biomarker multiples of the median (MoM) formulae for risk assessment of preterm pre-eclampsia (PE) in seven Asian populations, spanning the east, southeast and south regions of the continent, (ii) perform quality-assurance (QA) assessment of the biomarker measurements and (iii) establish criteria for prospective ongoing QA assessment of biomarker measurements. METHODS: This was a prospective, non-intervention, multicenter study in 4023 singleton pregnancies, at 11 to 13 + 6 weeks' gestation, in 11 recruiting centers in China, Hong Kong, India, Japan, Singapore, Taiwan and Thailand. Women were screened for preterm PE between December 2016 and June 2018 and gave written informed consent to participate in the study. Maternal and pregnancy characteristics were recorded and mean arterial pressure (MAP), mean uterine artery pulsatility index (UtA-PI) and maternal serum placental growth factor (PlGF) were measured in accordance with The Fetal Medicine Foundation (FMF) standardized measurement protocols. MAP, UtA-PI and PlGF were transformed into MoMs using the published FMF formulae, derived from a largely Caucasian population in Europe, which adjust for gestational age and covariates that affect directly the biomarker levels. Variations in biomarker MoM values and their dispersion (SD) and cumulative sum tests over time were evaluated in order to identify systematic deviations in biomarker measurements from the expected distributions. RESULTS: In the total screened population, the median (95% CI) MoM values of MAP, UtA-PI and PlGF were 0.961 (0.956-0.965), 1.018 (0.996-1.030) and 0.891 (0.861-0.909), respectively. Women in this largely Asian cohort had approximately 4% and 11% lower MAP and PlGF MoM levels, respectively, compared with those expected from normal median formulae, based on a largely Caucasian population, whilst UtA-PI MoM values were similar. UtA-PI and PlGF MoMs were beyond the 0.4 to 2.5 MoM range (truncation limits) in 16 (0.4%) and 256 (6.4%) pregnancies, respectively. QA assessment tools indicated that women in all centers had consistently lower MAP MoM values than expected, but were within 10% of the expected value. UtA-PI MoM values were within 10% of the expected value at all sites except one. Most PlGF MoM values were systematically 10% lower than the expected value, except for those derived from a South Asian population, which were 37% higher. CONCLUSIONS: Owing to the anthropometric differences in Asian compared with Caucasian women, significant differences in biomarker MoM values for PE screening, particularly MAP and PlGF MoMs, were noted in Asian populations compared with the expected values based on European-derived formulae. If reliable and consistent patient-specific risks for preterm PE are to be reported, adjustment for additional factors or development of Asian-specific formulae for the calculation of biomarker MoMs is required. We have also demonstrated the importance and need for regular quality assessment of biomarker values. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Pueblo Asiatico/estadística & datos numéricos , Preeclampsia/diagnóstico , Primer Trimestre del Embarazo/etnología , Diagnóstico Prenatal/métodos , Medición de Riesgo/etnología , Adulto , Antropometría , Presión Arterial , Asia , Biomarcadores/análisis , Femenino , Humanos , Factor de Crecimiento Placentario/sangre , Preeclampsia/etnología , Embarazo , Flujo Pulsátil , Garantía de la Calidad de Atención de Salud , Medición de Riesgo/métodos , Ultrasonografía Prenatal , Arteria Uterina/diagnóstico por imagen , Arteria Uterina/embriología
7.
Ultrasound Obstet Gynecol ; 54(2): 199-206, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30381845

RESUMEN

OBJECTIVE: To evaluate Sylvian fissure development by assessing Sylvian fissure angles in fetuses with malformation of cortical development (MCD). METHODS: This was a retrospective study of 22 fetuses with MCD. Cases with a stored three-dimensional (3D) brain volume acquired at 18 + 0 to 30 + 6 weeks of gestation at an ultrasound-based research clinic between January 2010 and December 2017 were identified through a database. Of the 22 fetuses, seven had an extracranial abnormality, such as cardiac, renal, gastrointestinal and/or digital anomalies, and five had a minor abnormality such as micrognathia, low-set ears and/or single umbilical artery. To confirm the final clinical diagnosis of brain abnormality, postmortem histological findings or prenatal or postnatal magnetic resonance images were used. For measurement of Sylvian fissure angle, an anterior coronal plane of the fetal brain on transvaginal 3D volume multiplanar imaging was visualized as a single image from the three orthogonal views. The right and left Sylvian fissure angles were measured between a horizontal reference line (0°) and a line drawn along the upper side of the respective Sylvian fissure. The Sylvian fissure angle on both sides was plotted on the graphs of the reference ranges for gestational age in weeks. RESULTS: In 21 (95.5%; 95% CI, 86.8-100.0%) of 22 fetuses with MCD, the Sylvian fissure angle on one or both sides was larger than the 90th percentile of the normal reference. There was one case with apparent focal MCD in the parietal lobe, but the Sylvian fissure angles were normal. A case with apparent unilateral cortical dysplasia and one with apparent unilateral schizencephaly had conspicuous discrepancies between the left and right Sylvian fissure angles. Abnormal genetic test results were obtained in six cases, including four cases with a mutation in a single gene. CONCLUSIONS: This study has shown that the Sylvian fissures, as defined by the Sylvian fissure angle, have delayed development in most MCD cases prior to the diagnosis of the condition. The Sylvian fissure angle may potentially be a strong indicator for the subsequent development of cortical malformation, before the time point at which the gyri and sulci become obvious on the fetal brain surface. Further research is required to validate these findings. © 2018 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Corteza Cerebral/anomalías , Corteza Cerebral/diagnóstico por imagen , Anomalías Congénitas/diagnóstico por imagen , Malformaciones del Desarrollo Cortical/diagnóstico por imagen , Autopsia , Encéfalo/anatomía & histología , Encéfalo/diagnóstico por imagen , Corteza Cerebral/embriología , Anomalías Congénitas/genética , Anomalías Congénitas/patología , Femenino , Desarrollo Fetal , Feto , Edad Gestacional , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Malformaciones del Desarrollo Cortical/genética , Malformaciones del Desarrollo Cortical/patología , Embarazo , Segundo Trimestre del Embarazo , Tercer Trimestre del Embarazo , Valores de Referencia , Estudios Retrospectivos , Ultrasonografía Doppler Transcraneal/métodos , Ultrasonografía Prenatal/métodos
8.
Ultrasound Obstet Gynecol ; 54(2): 190-198, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30381851

RESUMEN

OBJECTIVE: To (1) evaluate the normal development of the Sylvian fissures in the anterior coronal view of the fetal brain at 18-30 weeks' gestation by transvaginal three-dimensional (3D) ultrasound, (2) develop reference ranges of measurements of the right and left Sylvian fissure angles during normal pregnancy at 18-30 weeks' gestation, and (3) examine intra- and interobserver repeatability of measurements of the right and left Sylvian fissure angles. METHODS: This was a prospective cross-sectional study of 422 women with a singleton pregnancy attending an ultrasound-based research clinic between March and December 2017. The entry criteria for the study were appropriately grown live fetus with no suspected structural and/or chromosomal defects between 18 + 0 and 30 + 6 weeks' gestation. Normal development of the Sylvian fissures was assessed in the anterior coronal plane of the fetal brain using transvaginal 3D volume multiplanar imaging. The coronal view was visualized as a single image from the three orthogonal views. Subsequently, the right and left Sylvian fissure angles were measured between a horizontal reference line (0°) and a line drawn along the upper side of the respective Sylvian fissure. Intra- and interobserver repeatability of the Sylvian fissure angle measurements was assessed by Bland-Altman plots. Reference equations were constructed for right and left Sylvian fissure angles for gestational age (GA) and head circumference (HC) using the Generalized Additive Models for Location Scale and Shape package. RESULTS: In the anterior coronal view of the fetal brain, an inward rotation of the upper portion of the Sylvian fissures was observed during the second and third trimesters of pregnancy. There was a significant negative polynomial association between the Sylvian fissure angles and GA and HC. Both Sylvian fissure angles crossed the reference line (zero), going from positive to negative, at around 25 weeks' gestation or at HC of 22 cm. Z-score difference between the smoothed percentiles of the right and left Sylvian fissure angles indicated that median, 10th and 90th smoothed percentiles were closest and almost the same for the GA-based references between 18 and 28 weeks and for the HC-based references between 14 and 24 cm. The intraclass correlation coefficient of the right and left Sylvian fissure angle measurements between the two sonographers was excellent at 0.993 (95% CI, 0.988-0.996) and 0.991 (95% CI, 0.985-0.995), respectively. On Bland-Altman analysis, the mean difference between the two sonographers in right Sylvian fissure angle measurement was 0.4° (95% CI, -10.2 to 10.1°) and in left Sylvian fissure angle it was 1.0° (95% CI, -9.6 to 11.6°). CONCLUSIONS: Assessment of the Sylvian fissure angles is highly reproducible. Sylvian fissure angle reference charts can serve as a screening tool for malformations of cortical development, guiding subsequent follow-up and referral for fetal brain magnetic resonance imaging and/or assessment by an expert neurosonologist. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Corteza Cerebral/anatomía & histología , Corteza Cerebral/diagnóstico por imagen , Imagenología Tridimensional/instrumentación , Adulto , Corteza Cerebral/embriología , Estudios Transversales , Femenino , Desarrollo Fetal/fisiología , Edad Gestacional , Humanos , Variaciones Dependientes del Observador , Embarazo , Segundo Trimestre del Embarazo , Tercer Trimestre del Embarazo , Estudios Prospectivos , Valores de Referencia , Ultrasonografía , Ultrasonografía Prenatal/métodos
9.
Ultrasound Obstet Gynecol ; 52(5): 639-647, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28976627

RESUMEN

OBJECTIVES: To define a protocol for the first-trimester assessment of uterine artery pulsatility index (UtA-PI) using the new transverse technique, to evaluate UtA-PI measured using the transverse approach vs that obtained using the conventional sagittal approach and to determine if accelerated onsite training (in both methods) of inexperienced sonographers can achieve reproducible UtA-PI measurements comparable with those obtained by an experienced sonographer. METHODS: This was a prospective observational study of women with a singleton pregnancy attending for routine combined first-trimester screening at 11 to 13 + 6 weeks' gestation. The study consisted of two parts, each conducted at a different center (Part 1 in Calgary, Canada and Part 2 in Hong Kong). In Part 1, UtA-PI measurements were performed using the transverse and sagittal techniques by four sonographers trained in both methods, in 10 cases each, and measurement indices (PI), time required and subjective difficulty in obtaining satisfactory measurements were compared. The one sample t-test and Wilcoxon signed rank test were used when appropriate. Bland-Altman plots were used to assess measurement agreement, and intraclass correlation coefficient (ICC) was used to evaluate measurement reliability. A target plot was used to assess measures of central tendency and dispersion. In Part 2, one experienced and three inexperienced sonographers prospectively measured UtA-PI using both approaches in 42 and 35 women, respectively. Inexperienced sonographers underwent accelerated onsite training by the experienced sonographer. Measurement approach and sonographer order were on a random basis. ICC, Bland-Altman and Passing-Bablok analyses were performed to assess measurement agreement and reliability and effect of accelerated training. RESULTS: In Part 1, no difference was observed between the two techniques in mean time to acquire the measurements (118 s for sagittal vs 106 s for transverse; P = 0.38). The four sonographers reported that the transverse technique was subjectively easier to perform (P = 0.04). Bias and ICC for mean UtA-PI between sagittal and transverse measurements were -0.05 (95% limits of agreement, -0.48 to 0.37) and 0.94, respectively. Measurements obtained using the transverse technique after correcting for gestational age were significantly closer to the expected distribution than those obtained using the sagittal technique. In Part 2, there were no significant differences in median UtA-PI measured using the different approaches for both experienced and inexperienced sonographers (P > 0.05 for all sonographers). Mean UtA-PI measurement reliability between approaches was high for the experienced (ICC = 0.92) and inexperienced (ICC > 0.80) sonographers. UtA-PI measurement approaches did not deviate from linearity, while bias ranged from -0.10 to 0.07. The median time required was similar between the techniques (56.1 s for sagittal vs 49.3 s for transverse; P = 0.054). CONCLUSIONS: This novel transverse approach for the measurement of UtA-PI in the first trimester appears to be comparable with the sagittal approach in terms of reliability, reproducibility and time required, and may be easier to perform. Providing accelerated onsite training can be helpful for improving the reliability of UtA-PI measurements and could potentially facilitate the broad implementation of first-trimester pre-eclampsia screening. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Preeclampsia/diagnóstico por imagen , Ultrasonografía Prenatal , Arteria Uterina/diagnóstico por imagen , Adulto , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Preeclampsia/fisiopatología , Valor Predictivo de las Pruebas , Embarazo , Primer Trimestre del Embarazo , Estudios Prospectivos , Flujo Pulsátil , Arteria Uterina/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA