Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Int J Oral Maxillofac Implants ; 35(5): 955-964, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32991646

RESUMEN

PURPOSE: To assess the effects of drilling protocol and bone density on the primary stability of implants with different macrogeometries currently used in clinical practice. MATERIALS AND METHODS: This in vitro study compared the designs of two implants: Biomimetic Coral, a parallel-walled design with a slightly expanded platform and a symmetric progressive thread; and tapered Biomimetic Ocean, a reverse coronal design with an asymmetric progressive thread. The drilling alternatives were grouped according to the standard sequence for each type, plus an extra drill for hard bone, using laminated blocks with different densities. The insertion torques and implant stability quotient (ISQ) values were obtained with a surgical motor and resonance frequency analysis (RFA), respectively. RESULTS: A total of 120 implants (n = 60 Ocean, n = 60 Coral) were inserted and analyzed without registering any deviation from the protocol. The Coral implants presented significantly higher insertion torque values (P < .001), consistent with optimal osseointegration, for the standard drill, the dense bone drill, and the screw tap. Insertion torque was not affected by the drilling sequence (P = .124), and the effect of interaction between the implant design and drilling sequence was not significant (P = .940). Statistically significant differences were observed in insertion torque values due to the type of implant but not due to the bone density. The ISQ values were significantly higher (P < .001) for the Coral design. In both the Ocean and Coral implants, ISQ was affected by the drilling sequence (P < .001), as the ISQ values were higher in the standard sequence with screw tap drilling than in the standard sequence with a dense bone drill. A positive correlation was found between the insertion torque and ISQ values. CONCLUSION: The macrogeometry of the implant and the drilling sequence have a significant effect on both primary stability values (ISQ and insertion torque). The values for the Coral implant were statistically higher but still within the range required to achieve proper osseointegration. These results support the drilling sequence recommended by the manufacturer for this type of implant, using larger-diameter drills and screw taps in sites with harder or cortical bone.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Densidad Ósea , Oseointegración , Análisis de Frecuencia de Resonancia
2.
Craniomaxillofac Trauma Reconstr ; 11(3): 219-223, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30087752

RESUMEN

The mortality associated with high-energy trauma has several time peaks and variable prognosis. In the particular case of isolated head and neck trauma, management initially includes stabilizing the patient, especially the airway and circulation, and then proceeding to treat injured structures with debridement and often fracture fixation and coverage. We present a case of a male patient who suffered a severe facial trauma at his workplace. He underwent an initial uneventful emergency surgery for control of bleeding and mandibular osteosynthesis. At 2 weeks postoperatively, a second emergency surgery was required to treat a previously undiagnosed lingual pseudoaneurysm that ruptured spontaneously, with massive oral bleeding. The case highlights the clinical significance and timing of pseudoaneurysm formation, and the surveillance and high index of suspicion required for potentially life-threatening bleeding at later time peaks. Diagnostic and therapeutic angiography effectively treated the late complication. Multidisciplinary management options are reviewed, emphasizing the need for rapid decision making and collaboration to improve outcomes in such significant surgical trauma patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA