Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 232
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 149(9): 644-655, 2024 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-37883682

RESUMEN

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estudios Prospectivos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Accidente Cerebrovascular/etiología
2.
N Engl J Med ; 386(4): 327-339, 2022 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-34767705

RESUMEN

BACKGROUND: Tricuspid regurgitation is common in patients with severe degenerative mitral regurgitation. However, the evidence base is insufficient to inform a decision about whether to perform tricuspid-valve repair during mitral-valve surgery in patients who have moderate tricuspid regurgitation or less-than-moderate regurgitation with annular dilatation. METHODS: We randomly assigned 401 patients who were undergoing mitral-valve surgery for degenerative mitral regurgitation to receive a procedure with or without tricuspid annuloplasty (TA). The primary 2-year end point was a composite of reoperation for tricuspid regurgitation, progression of tricuspid regurgitation by two grades from baseline or the presence of severe tricuspid regurgitation, or death. RESULTS: Patients who underwent mitral-valve surgery plus TA had fewer primary-end-point events than those who underwent mitral-valve surgery alone (3.9% vs. 10.2%) (relative risk, 0.37; 95% confidence interval [CI], 0.16 to 0.86; P = 0.02). Two-year mortality was 3.2% in the surgery-plus-TA group and 4.5% in the surgery-alone group (relative risk, 0.69; 95% CI, 0.25 to 1.88). The 2-year prevalence of progression of tricuspid regurgitation was lower in the surgery-plus-TA group than in the surgery-alone group (0.6% vs. 6.1%; relative risk, 0.09; 95% CI, 0.01 to 0.69). The frequencies of major adverse cardiac and cerebrovascular events, functional status, and quality of life were similar in the two groups at 2 years, although the incidence of permanent pacemaker implantation was higher in the surgery-plus-TA group than in the surgery-alone group (14.1% vs. 2.5%; rate ratio, 5.75; 95% CI, 2.27 to 14.60). CONCLUSIONS: Among patients undergoing mitral-valve surgery, those who also received TA had a lower incidence of a primary-end-point event than those who underwent mitral-valve surgery alone at 2 years, a reduction that was driven by less frequent progression to severe tricuspid regurgitation. Tricuspid repair resulted in more frequent permanent pacemaker implantation. Whether reduced progression of tricuspid regurgitation results in long-term clinical benefit can be determined only with longer follow-up. (Funded by the National Heart, Lung, and Blood Institute and the German Center for Cardiovascular Research; ClinicalTrials.gov number, NCT02675244.).


Asunto(s)
Anuloplastia de la Válvula Cardíaca , Progresión de la Enfermedad , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Dilatación Patológica , Femenino , Estudios de Seguimiento , Humanos , Análisis de Intención de Tratar , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/mortalidad , Marcapaso Artificial , Complicaciones Posoperatorias , Calidad de Vida , Reoperación , Análisis de Supervivencia , Válvula Tricúspide/patología , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/terapia
3.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

4.
Am Heart J ; 270: 86-94, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38309610

RESUMEN

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Válvula Aórtica/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Puente de Arteria Coronaria , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 103(1): 194-201, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38037296

RESUMEN

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS: Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS: Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION: Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/terapia , Diseño de Prótesis
6.
World J Surg ; 48(7): 1771-1782, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38686961

RESUMEN

BACKGROUND: The benefits and harms associated with femoral artery cannulation over other sites of arterial cannulation for surgical repair of acute Stanford type A aortic dissection (TAAD) are not conclusively established. METHODS: We evaluated the outcomes after surgery for TAAD using femoral artery cannulation, supra-aortic arterial cannulation (i.e., innominate/subclavian/axillary artery cannulation), and direct aortic cannulation. RESULTS: 3751 (96.1%) patients were eligible for this analysis. In-hospital mortality using supra-aortic arterial cannulation was comparable to femoral artery cannulation (17.8% vs. 18.4%; adjusted OR 0.846, 95% CI 0.799-1.202). This finding was confirmed in 1028 propensity score-matched pairs of patients with supra-aortic arterial cannulation or femoral artery cannulation (17.5% vs. 17.0%, p = 0.770). In-hospital mortality after direct aortic cannulation was lower compared to femoral artery cannulation (14.0% vs. 18.4%, adjusted OR 0.703, 95% CI 0.529-0.934). Among 583 propensity score-matched pairs of patients, direct aortic cannulation was associated with lower rates of in-hospital mortality (13.4% vs. 19.6%, p = 0.004) compared to femoral artery cannulation. Switching of the primary site of arterial cannulation was associated with increased rate of in-hospital mortality (36.5% vs. 17.0%; adjusted OR 2.730, 95% CI 1.564-4.765). Ten-year mortality was similar in the study cohorts. CONCLUSIONS: In this study, the outcomes of surgery for TAAD using femoral arterial cannulation were comparable to those using supra-aortic arterial cannulation. However, femoral arterial cannulation was associated with higher in-hospital mortality than direct aortic cannulation. TRIAL REGISTRATION: ClinicalTrials.gov registration code: NCT04831073.


Asunto(s)
Disección Aórtica , Arteria Femoral , Mortalidad Hospitalaria , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/mortalidad , Disección Aórtica/cirugía , Disección Aórtica/mortalidad , Cateterismo/métodos , Cateterismo Periférico/métodos , Arteria Femoral/cirugía , Puntaje de Propensión , Estudios Retrospectivos , Resultado del Tratamiento
7.
Ann Surg ; 278(4): e885-e892, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36912033

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the outcomes of different surgical strategies for acute Stanford type A aortic dissection (TAAD). SUMMARY BACKGROUND DATA: The optimal extent of aortic resection during surgery for acute TAAD is controversial. METHODS: This is a multicenter, retrospective cohort study of patients who underwent surgery for acute TAAD at 18 European hospitals. RESULTS: Out of 3902 consecutive patients, 689 (17.7%) died during the index hospitalization. Among 2855 patients who survived 3 months after surgery, 10-year observed survival was 65.3%, while country-adjusted, age-adjusted, and sex-adjusted expected survival was 81.3%, yielding a relative survival of 80.4%. Among 558 propensity score-matched pairs, total aortic arch replacement increased the risk of in-hospital (21.0% vs. 14.9%, P =0.008) and 10-year mortality (47.1% vs. 40.1%, P =0.001), without decreasing the incidence of distal aortic reoperation (10-year: 8.9% vs. 7.4%, P =0.690) compared with ascending aortic replacement. Among 933 propensity score-matched pairs, in-hospital mortality (18.5% vs. 18.0%, P =0.765), late mortality (at 10-year: 44.6% vs. 41.9%, P =0.824), and cumulative incidence of proximal aortic reoperation (at 10-year: 4.4% vs. 5.9%, P =0.190) after aortic root replacement was comparable to supracoronary aortic replacement. CONCLUSIONS: Replacement of the aortic root and aortic arch did not decrease the risk of aortic reoperation in patients with TAAD and should be performed only in the presence of local aortic injury or aneurysm. The relative survival of TAAD patients is poor and suggests that the causes underlying aortic dissection may also impact late mortality despite surgical repair of the dissected aorta.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Disección Aórtica , Implantación de Prótesis Vascular , Humanos , Aneurisma de la Aorta/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Disección Aórtica/cirugía , Reoperación , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos
8.
Catheter Cardiovasc Interv ; 102(2): 318-327, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37354444

RESUMEN

BACKGROUND: Transcatheter mitral valve implantation (TMVI) is a novel therapeutic option for treating symptomatic mitral valve disease. Evaluating patient anatomical suitability is a critical step in the TMVI screening process, but currently requires specialized software and computerized device models. AIMS: This analysis sought to assess the effectiveness of simple and standardized multislice computed tomography (MSCT) anatomic measurements for their ability to discriminate between patients who passed anatomical screening for Tendyne™ TMVI. METHODS: Subjects screened for the Tendyne Expanded Clinical Study from January 2016 through September 2019 were included. Core laboratory screening measurements included mitral annular (MA) dimensions at end-systole and end-diastole, simulated device implantation, and neo-left ventricular outflow tract (LVOT) area. Additionally, nine standard measurements of patient anatomy were assessed for their predictive value of patients passing the anatomic screening process. RESULTS: Out of 496 subjects screened for eligibility, 257 subjects met clinical eligibility criteria with MA dimensions within the manufacturer's suggested range: 153 (59.5%) underwent TMVI while 104 (40.5%) were excluded from the study for other anatomic reasons (76% due to risk of LVOT obstruction). CT-derived left ventricular end-systole diameter (LVESD) had the highest discriminatory power for predicting TMVI anatomical suitability (area under the curve of 0.908, p < 0.0001). The mitral inter-commissural (IC) dimension was best predictive of annular dimensions being within range, with dimensions <30 or >50 mm resulting in a negative predictive value of 94.4%. CONCLUSIONS: MSCT-derived mitral IC dimension and LVESD easily performed measures that are effective predictors of anatomical suitability or screen failure for this tether-based TMVI device.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco , Resultado del Tratamiento
9.
World J Surg ; 47(11): 2899-2908, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37432422

RESUMEN

AIMS: In this study we evaluated the impact of direct aortic cannulation versus innominate/subclavian/axillary artery cannulation on the outcome after surgery for type A aortic dissection. METHODS: The outcomes of patients included in a multicenter European registry (ERTAAD) who underwent surgery for acute type A aortic dissection with direct aortic cannulation versus those with innominate/subclavian/axillary artery cannulation, i.e. supra-aortic arterial cannulation, were compared using propensity score matched analysis. RESULTS: Out of 3902 consecutive patients included in the registry, 2478 (63.5%) patients were eligible for this analysis. Direct aortic cannulation was performed in 627 (25.3%) patients, while supra-aortic arterial cannulation in 1851 (74.7%) patients. Propensity score matching yielded 614 pairs of patients. Among them, patients who underwent surgery for TAAD with direct aortic cannulation had significantly decreased in-hospital mortality (12.7% vs. 18.1%, p = 0.009) compared to those who had supra-aortic arterial cannulation. Furthermore, direct aortic cannulation was associated with decreased postoperative rates of paraparesis/paraplegia (2.0 vs. 6.0%, p < 0.0001), mesenteric ischemia (1.8 vs. 5.1%, p = 0.002), sepsis (7.0 vs. 14.2%, p < 0.0001), heart failure (11.2 vs. 15.2%, p = 0.043), and major lower limb amputation (0 vs. 1.0%, p = 0.031). Direct aortic cannulation showed a trend toward decreased risk of postoperative dialysis (10.1 vs. 13.7%, p = 0.051). CONCLUSIONS: This multicenter cohort study showed that direct aortic cannulation compared to supra-aortic arterial cannulation is associated with a significant reduction of the risk of in-hospital mortality after surgery for acute type A aortic dissection. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04831073.


Asunto(s)
Disección Aórtica , Cateterismo , Humanos , Estudios de Cohortes , Resultado del Tratamiento , Aorta , Disección Aórtica/cirugía , Estudios Retrospectivos
10.
Am Heart J ; 247: 112-122, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35149038

RESUMEN

BACKGROUND: Despite continuous improvements in transcatheter aortic valve implantation (TAVI), periprocedural strokes remain a devastating complication. Randomized controlled trials failed to demonstrate a reduction in clinically apparent strokes or mortality after TAVI due to cerebral embolic protection (CEP). To identify potential targets of CEP strategies during TAVI, we evaluated affected brain regions, and temporal patterns of stroke onset in a routine clinical sample. METHODS AND RESULTS: A total of 3,164 consecutive patients treated with TAVI from 2008 to 2019 at a single center were screened for cerebrovascular events. Affected cerebral regions were determined according to clinical symptoms and brain imaging. Rates of disabling stroke and non-disabling stroke at 30 days were 2.2% and 1.4%, respectively. The frequency of all strokes decreased from 5.0% to 3.0% over time (P = .012). Patients with impaired left-ventricular function (OR 2.19), increased CHA2DS2-VASc (OR 1.39) and moderate/severe spontaneous echo contrast (OR 3.60) had a higher stroke risk. Acute symptom onset occurred during TAVI (19.4%), within 24 hours (40.3%) or later (25.0%); 98.3% of strokes were of ischemic origin. In intraprocedural strokes, 53.2% of lesions were found in locations considered protected by current CEP devices, and 37.5% of patients with intraprocedural strokes were exclusively affected in these areas. Baseline or procedural parameters were not associated with embolic distribution patterns. CONCLUSIONS: Most strokes occurred early after TAVI - but not necessarily during the procedure - and affected multiple brain regions only partially protected by current CEP devices. Efficient prevention of cerebrovascular events may require strategies beyond the TAVI procedure to minimize stroke risk and additional randomized controlled trials will be required to clarify the role of CEP in efficient stroke prevention during TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Implantación de Prótesis de Válvulas Cardíacas , Embolia Intracraneal , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Encéfalo/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Embolia Intracraneal/epidemiología , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
11.
J Vasc Surg ; 75(3): 868-876.e3, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34600031

RESUMEN

BACKGROUND: The aim of the study was to demonstrate the safety and effectiveness of a suture-mediated vascular closure device to perform hemostasis after an axillary artery access during endovascular procedures on the aortic valve, the aorta and its side branches. METHODS: A physician-initiated, international, multicenter, retrospective registry was designed to evaluate the success rate (VARC-2 reporting standards) of percutaneous transaxillary access closure with a suture-mediated closure device. Secondary end points were minor access vascular complications, transient peripheral nerve injury, stroke, and influence on periprocedural outcomes of puncture technique. RESULTS: Three hundred thirty-one patients (median age, 76 years; 69.2% males) in 11 centers received a percutaneous transaxillary access during endovascular cardiac (n = 166) or vascular (n = 165) procedures. The closure success rate was 84.6%, with 5 open conversions (1.5%), 45 adjunctive endovascular procedures (13.6%), and 1 nerve injury (0.3%). Secondary closure success was obtained in 325 patients (98%) after 7 bare stenting, 37 covered stenting, and 1 thrombin injection. Introducer sheaths 16F or larger (odds ratio, 3.70; 95% confidence interval, 1.22-11.42) and balloon-assisted hemostasis (odds ratio, 4.45; 95% confidence interval, 1.27-15.68) were associated with closure failure. A threshold of five percutaneous axillary accesses was associated with decreased rates of open conversion, but not with increased primary closure success. Primary closure success was 90.3% in the 175 patients with sheaths smaller than 16F, performed after the first 5 procedures in each center. Temporary nerve injury and stroke were observed in 2% and 4% of patients, respectively. CONCLUSIONS: Percutaneous transaxillary aortic procedures, in selected patients, can be performed with low rates of open conversion. The need for additional endovascular bailout procedures is not negligible when introducers sheaths 16F or larger are required.


Asunto(s)
Aorta Torácica/cirugía , Enfermedades de la Aorta/cirugía , Válvula Aórtica/cirugía , Arteria Axilar , Implantación de Prótesis Vascular , Cateterismo Periférico , Procedimientos Endovasculares , Enfermedades de las Válvulas Cardíacas/cirugía , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Cateterismo Periférico/efectos adversos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Europa (Continente) , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Punciones , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
12.
J Endovasc Ther ; 29(5): 711-716, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34964371

RESUMEN

PURPOSE: The concept of a single endovascular valve-carrying conduit device was designated endo-Bentall, but published experience is limited to a single case. This technical note describes an alternative modular endo-Bentall technique and a novel access technique to implant it. TECHNIQUE: A 82-year-old woman with chest pain referred for a 10 cm symptomatic aneurysm of the distal arch and descending aorta. An ascending aortic aneurysm of 5.5 cm prevented endovascular aortic arch repair due to lack of a proximal landing zone. The technique is a modular approach combining a physician-modified endograft (PMEG) with 3 large fenestrations for coronary artery perfusion and a transcatheter aortic valve implantation (TAVI). A "rendez-vous access" with a transapical and transfemoral through-and-through wire offered rapid sequential deployment in a modular fashion of both components. The PMEG was deployed first, landing 5 mm deep in the left ventricular outflow tract (LVOT) and the transcatheter aortic valve was implanted few millimeters below. The endo-Bentall procedure was combined with endovascular aortic arch repair. CONCLUSION: A modular endo-Bentall procedure combining a PMEG and TAVI is feasible and adaptable to emergent setting using the "rendez-vous access."


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Femenino , Humanos , Resultado del Tratamiento
13.
BMC Cardiovasc Disord ; 22(1): 341, 2022 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-35906536

RESUMEN

BACKGROUND: Blunt chest injury may induce several cardiovascular traumata, requiring immediate care. Right coronary artery dissection (RCA) is an extremely rare sequela in this setting and is associated with high mortality, if it remains undiagnosed. Case presentation We present the case of an RCA dissection after blunt chest trauma in a 16-year-old patient, who initially presented with a second-degree atrioventricular block as solitary manifestation on admission. Typical electrocardiographic findings, such as ST segmental changes or pathological Q waves were absent. Serial echocardiograms excluded segmental motion abnormalities, pericardial effusion or right ventricular strain. Nevertheless, a complementary computed tomography coronary angiography revealed this potentially lethal condition several hours later. The patient underwent an emergency surgical myocardial revascularization under the circulatory support of veno-arterial extracorporeal membrane oxygenation and suffered a prolonged right ventricular insufficiency with severe late-onset cardiogenic shock, due to an extensive myocardial infarction of the inferoseptal ventricular wall. CONCLUSION: Right coronary artery dissection after high-speed blunt chest injury constitutes a diagnostic challenge, especially in the absence of typical electrocardiographic and echocardiographic findings in young patients. This condition may dramatically deteriorate in time, leading to severe cardiogenic shock and life-threatening arrhythmias.


Asunto(s)
Disección Aórtica , Bloqueo Atrioventricular , Traumatismos Torácicos , Heridas no Penetrantes , Adolescente , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/lesiones , Vasos Coronarios/cirugía , Humanos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Traumatismos Torácicos/complicaciones , Traumatismos Torácicos/diagnóstico por imagen , Traumatismos Torácicos/cirugía , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/diagnóstico por imagen
14.
Catheter Cardiovasc Interv ; 98(2): E291-E298, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33315296

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) via transaxillary (TAx) approach with ACURATE neo valve is an off-label procedure. Our aim was to gather information on ACURATE neo cases implanted via TAx approach and report major outcomes. METHODS AND RESULTS: The TRANSAX Study (NCT04274751) retrospectively gathered patients from nine centres in Europe and North America treated with ACURATE neo valve through TAx approach up to May/2019. Follow up was pre-specified at 1-year and was obtained for all patients. A total of 75 patients (79 ± 10 years; 32% women) were included. Left axillary (72%) and conscious sedation (95.2%) were the most common setting. Risk scores were higher when right axillary artery and surgical cut-down were selected. Severe complications including valve embolization, coronary obstruction, annulus rupture, and procedural mortality did not occur. Cardiac tamponade occurred in two cases (2.7%) with one requiring conversion to open surgery (1.3%). Bail-out stenting and surgical vascular repair were required in 7 (9.3%) and 3 (4%) cases, respectively. The need for new permanent pacemaker was 8%. Procedural success (96%), in-hospital (2.7%), and 1-year mortality (8%) were comparable in all settings. Only one case (1.3%) complicated with cerebrovascular event and one (1.3%) presented moderate aortic regurgitation before discharge. CONCLUSIONS: TAx TAVR procedures with the ACURATE neo valve were presented high success rate and low in-hospital and 1-year mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 98(4): 756-764, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33991385

RESUMEN

OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS: BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Seguimiento , Hemodinámica , Humanos , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Thorac Cardiovasc Surg ; 69(5): 428-436, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32114689

RESUMEN

BACKGROUND: We herein aimed for analysis of influence of mitral annular calcification (MAC) and mitral stenosis (MS) on outcomes in transcatheter aortic valve implantation (TAVI). METHODS: Between 11/2009 and 06/2017, 1,058 patients underwent TAVI in the presence of concomitant MAC or MS at our center. Subgroups were built and multivariate logistic regression, COX regression, Kaplan-Meier survival analyses, and receiver operating characteristics method were performed. RESULTS: Thirty-day mortality was 7.5% (79/1,058) with highest mortality in patients severe MS (MAC: 3.4% vs. mild MS: 5.9% vs. moderate MS: 15.0% vs. severe MS: 72.7%; p < 0.001). Moderate-to-severe MS (odds ratio [OR]: 7.75, confidence interval [CI]: 3.94-16.26, p < 0.001), impaired left ventricular ejection fraction (OR: 1.38, CI: 1.10-1.72, p < 0.01), and coronary artery disease (OR: 1.36, CI: 1.11-1.67, p < 0.01) were predictive of 30-day survival. Left ventricular systolic/end-diastolic pressure drop of <59.5 mm Hg / <19.5 mm Hg was associated with increased mortality. CONCLUSIONS: TAVI in the presence of MAC and mild MS is associated with acceptable acute outcomes but should be considered high-risk procedures in patients with moderate and especially those with severe MS. Our results suggest adverse hemodynamics after TAVI with concomitant MS, which may be caused by underfilling of the left ventricle leading to low-cardiac output.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Calcinosis/fisiopatología , Hemodinámica , Estenosis de la Válvula Mitral/fisiopatología , Válvula Mitral/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Femenino , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/mortalidad , Complicaciones Posoperatorias/etiología , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
17.
Surg Technol Int ; 39: 261-265, 2021 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-34699604

RESUMEN

Transcatheter aortic valve implantation (TAVI) is an established therapy for severe symptomatic aortic valve stenosis (AS) in patients at high and intermediate risk for surgical aortic valve replacement (SAVR). Current evidence also suggests at least non-inferiority of TAVI in low-risk patients compared to SAVR. However, there are special subsets of patients and anatomical circumstances in which TAVI is traditionally considered a suboptimal treatment strategy due to procedure inherent increased risks (e.g., rupture of cardiac chambers in patients with severe calcifications of the left ventricular outflow tract, valve migration in very large aortic annuli). One of these special subsets is bicuspid AS. Bicuspid aortic valve disease is the most common congenital heart defect and most frequent reason for AS in patients <70 years of age. Bicuspid aortic valve pathology is characterized by special anatomical complexities like asymmetrical cusp proportion and calcium distribution, a more pronounced annular ellipticity compared to tricuspid aortic valves and concomitant dilation of the thoracic aorta. These factors have led physicians to traditionally indicate TAVI more reluctantly in those patients in the past. In this article, current evidence for TAVI for bicuspid AS is discussed and technical challenges are highlighted.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
18.
Circulation ; 139(16): 1865-1871, 2019 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-30732456

RESUMEN

BACKGROUND: The 30-day and 1-year follow-up analysis of the GOPCABE trial (German Off-Pump Coronary Artery Bypass Grafting in Elderly Patients) revealed no significant difference in the composite end point consisting of death, stroke, myocardial infarction, new renal replacement therapy, or repeat revascularization. The 5-year follow-up data of this trial are reported here. METHODS: From June 2008 to September 2011, a total of 2539 patients aged ≥75 years were randomly assigned to undergo off-pump or on-pump coronary artery bypass grafting (CABG) at 12 centers in Germany. The primary outcome was all-cause mortality at 5 years. The secondary 5-year outcomes were a composite of death, myocardial infarction, and repeat revascularization. Furthermore, the impact of complete versus incomplete revascularization was assessed. RESULTS: After a median follow-up of 5 years, 361 patients (31%) assigned to off-pump CABG and 352 patients (30%) assigned to on-pump CABG had died (hazard ratio off-pump/on-pump CABG, 1.03; 95% CI, 0.89-1.19; P=0.71). The composite outcome of death, myocardial infarction, and repeat revascularization occurred in 397 (34%) after off-pump and in 389 (33%) after on-pump CABG (hazard ratio, 1.03; 95% CI, 0.89-1.18; P=0.704). Incomplete revascularization occurred in 403 (34%) patients randomly assigned to off-pump and 354 (29%) patients randomly assigned to on-pump CABG ( P<0.001). Five-year survival rates were 72% (95% CI, 67-76) with incomplete versus 76% (95% CI, 74-80) with complete revascularization (log-rank test: P=0.02) after off-pump CABG and 72% (95% CI, 67-76) versus 77% (95% CI, 74-80) after on-pump CABG (log-rank test: P=0.03), respectively. Cox regression analysis revealed a hazard ratio incomplete/complete revascularization of 1.19 (95% CI, 1.01-1.39; P=0.04). CONCLUSIONS: In elderly patients ≥75 years of age, the 5-year survival rates and the combined outcome of death, myocardial infarction, and repeat revascularization, as well, were similar after on-pump and off-pump CABG. Incomplete revascularization was associated with a lower 5-year survival rate, irrespective of the type of surgery. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00719667.


Asunto(s)
Puente de Arteria Coronaria , Corazón Auxiliar , Infarto del Miocardio/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
19.
Lancet ; 394(10209): 1619-1628, 2019 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-31570258

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the preferred treatment option for older patients with symptomatic severe aortic stenosis. Differences in the properties of available TAVR systems can affect clinical outcomes. Among patients undergoing TAVR, we compared the self-expanding ACURATE neo TAVR system with the balloon-expandable SAPIEN 3 TAVR system with regard to early safety and efficacy. METHODS: In this randomised non-inferiority trial, patients (aged ≥75 years) undergoing transfemoral TAVR for treatment of symptomatic severe aortic stenosis, and who were deemed to be at increased surgical risk, were recruited at 20 tertiary heart valve centres in Germany, the Netherlands, Switzerland, and the UK. Participants were randomly assigned (1:1) to receive treatment with the ACURATE neo or the SAPIEN 3 with a computer-based randomly permuted block scheme, stratified by study centre and Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) category. The primary composite safety and efficacy endpoint comprised all-cause death, any stroke, life-threatening or disabling bleeding, major vascular complications, coronary artery obstruction requiring intervention, acute kidney injury (stage 2 or 3), rehospitalisation for valve-related symptoms or congestive heart failure, valve-related dysfunction requiring repeat procedure, moderate or severe prosthetic valve regurgitation, or prosthetic valve stenosis within 30 days of the procedure. Endpoint assessors were masked to treatment allocation. Non-inferiority of ACURATE neo compared with SAPIEN 3 was assessed in the intention-to-treat population on the basis of a risk-difference margin of 7·7% for the primary composite endpoint, with a one-sided α of 0·05. This trial is registered with ClinicalTrials.gov (number NCT03011346) and is ongoing but not recruiting. FINDINGS: Between Feb 8, 2017, and Feb 2, 2019, up to 5132 patients were screened and 739 (mean age 82·8 years [SD 4·1]; median STS-PROM score 3·5% [IQR 2·6-5·0]) were enrolled. 30-day follow-up was available for 367 (99%) of 372 patients allocated to the ACURATE neo group, and 364 (99%) of 367 allocated to the SAPIEN 3 group. Within 30 days, the primary endpoint occurred in 87 (24%) patients in the ACURATE neo and in 60 (16%) in the SAPIEN 3 group; thus, non-inferiority of the ACURATE neo was not met (absolute risk difference 7·1% [upper 95% confidence limit 12·0%], p=0·42). Secondary analysis of the primary endpoint suggested superiority of the SAPIEN 3 device over the ACURATE neo device (95% CI for risk difference -1·3 to -12·9, p=0·0156). The ACURATE neo and SAPIEN 3 groups did not differ in incidence of all-cause death (nine patients [2%] vs three [1%]) and stroke (seven [2%] vs 11 [3%]); whereas acute kidney injury (11 [3%] vs three [1%]) and moderate or severe prosthetic aortic regurgitation (34 [9%] vs ten [3%]) were more common in the ACURATE neo group. INTERPRETATION: TAVR with the self-expanding ACURATE neo did not meet non-inferiority compared to the balloon-expandable SAPIEN 3 device in terms of early safety and clinical efficacy outcomes. An early composite safety and efficacy endpoint was useful in discriminating the performance of different TAVR systems. FUNDING: Boston Scientific (USA).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/mortalidad , Causas de Muerte/tendencias , Femenino , Alemania/epidemiología , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Países Bajos/epidemiología , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Suiza/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido/epidemiología
20.
Am Heart J ; 225: 138-148, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32502877

RESUMEN

BACKGROUND: Compared to high gradient aortic stenosis (AS), patients with low-flow, low-gradient AS have higher mortality after transcatheter aortic valve replacement (TAVR), but distinct outcome predictors in this patient subset are yet to be determined. The present study investigated the prognostic impact of aortic valve calcification (AVC) in patients with low-flow, low-gradient AS undergoing TAVR. METHODS: This retrospective single-center analysis includes all patients undergoing TAVR for severe low-flow, low-gradient AS (n = 526), ie, low EF low gradient AS (LEF-LG AS; n = 290) and paradoxical low-flow, low-gradient AS (PLF-LG AS; n = 236), in whom AVC was quantified from contrast-enhanced multislice computed tomography images. AVCdensity was defined as calcium volume per annulus area. Patients were trichotomized according to sex-specific AVCdensity tertiles in both subgroups. All-cause mortality was assessed by Kaplan-Meier analyses and independent outcome predictors were determined by multivariable analyses. RESULTS: In both subgroups, patients with high AVCdensity had higher mean transvalvular gradients at baseline and higher rates of PVL after TAVR. High AVCdensity was associated with lowest 1- and 3-year mortality after TAVR in the LEF-LG AS but not in the PLF-LG AS group. According to multivariable analysis AVCdensity was independently associated with better survival in LEF-LG AS patients (HR 0.73 [0.60-0.88], P = .0011), but not in those with PLF-LG AS (HR 0.91 [0.73-1.14], P = .42). CONCLUSIONS: Quantification of AVC may not only be of diagnostic but also of prognostic value, as it facilitates the selection of LEF-LG AS patients with higher probability of beneficial outcome after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/clasificación , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Calcinosis/fisiopatología , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA