Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am Heart J ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Catheter Cardiovasc Interv ; 102(2): 221-232, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37232278

RESUMEN

BACKGROUND: Data about the long-term performance of new-generation ultrathin-strut drug-eluting stents (DES) in challenging coronary lesions, such as left main (LM), bifurcation, and chronic total occlusion (CTO) lesions are scant. METHODS: The international multicenter retrospective observational ULTRA study included consecutive patients treated from September 2016 to August 2021 with ultrathin-strut (<70 µm) DES in challenging de novo lesions. Primary endpoint was target lesion failure (TLF): composite of cardiac death, target-lesion revascularization (TLR), target-vessel myocardial infarction (TVMI), or definite stent thrombosis (ST). Secondary endpoints included all-cause death, acute myocardial infarction (AMI), target vessel revascularization, and TLF components. TLF predictors were assessed with Cox multivariable analysis. RESULTS: Of 1801 patients (age: 66.6 ± 11.2 years; male: 1410 [78.3%]), 170 (9.4%) experienced TLF during follow-up of 3.1 ± 1.4 years. In patients with LM, CTO, and bifurcation lesions, TLF rates were 13.5%, 9.9%, and 8.9%, respectively. Overall, 160 (8.9%) patients died (74 [4.1%] from cardiac causes). AMI and TVMI rates were 6.0% and 3.2%, respectively. ST occurred in 11 (1.1%) patients while 77 (4.3%) underwent TLR. Multivariable analysis identified the following predictors of TLF: age, STEMI with cardiogenic shock, impaired left ventricular ejection fraction, diabetes, and renal dysfunction. Among the procedural variables, total stent length increased TLF risk (HR: 1.01, 95% CI: 1-1.02 per mm increase), while intracoronary imaging reduced the risk substantially (HR: 0.35, 95% CI: 0.12-0.82). CONCLUSIONS: Ultrathin-strut DES showed high efficacy and satisfactory safety, even in patients with challenging coronary lesions. Yet, despite using contemporary gold-standard DES, the association persisted between established patient- and procedure-related features of risk and impaired 3-year clinical outcome.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Masculino , Persona de Mediana Edad , Anciano , Sirolimus , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Función Ventricular Izquierda , Infarto del Miocardio/etiología , Diseño de Prótesis , Stents/efectos adversos , Sistema de Registros , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones
3.
Catheter Cardiovasc Interv ; 99(1): 27-36, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34028964

RESUMEN

OBJECTIVE: Aim of this study is to evaluate short term safety and efficacy of Impella in high risk percutaneous coronary intervention (HR-PCI) population. BACKGROUND: While several studies demonstrated the clinical significance of Impella in HR-PCI, few data exist about its impact on short term outcome. METHODS: All studies reporting short term outcomes of PCI with any Impella device were included. The primary endpoint was either in-hospital or 30-day mortality, while vascular complications, post-procedural stroke, post-procedural dialysis and bleeding complications were assessed as secondary outcomes. RESULTS: Nine studies with 7448 patients were included. Median age was 69.5 years old (67-73), with a mean ejection fraction of 29.7% (20%-39%) and a Syntax score of 30.2 (25. 5-33, interquartile [IQR]). Impella 2.5 was the most commonly used axial flow pump used to support these PCIs (88.7%). In-hospital death was observed in 5.09% of patients (95% confidence interval [CI] 3.69-6.49, I2  = 78%), while vascular complications in 2.53% of patients (1.07-4.00, I2  = 89%) and post-procedural stroke in 2.77% of patients (0.50-6.05, I2  = 98%). Major bleeding occurred in 5.98% of patients (3.66-8.31, I2  = 90%) and post-procedural dialysis in 4.44% of patients (1.50-7.37, I2  = 93% all CI 93%). CONCLUSION: Use of Impella in high risk PCI appears to have an acceptable rate of complication, especially regarding vascular complications and major bleedings.


Asunto(s)
Corazón Auxiliar , Intervención Coronaria Percutánea , Anciano , Corazón Auxiliar/efectos adversos , Mortalidad Hospitalaria , Humanos , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 100(1): 122-130, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35485723

RESUMEN

INTRODUCTION: Despite limited to short and midterm outcomes, valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has emerged as a valid alternative to re-surgical aortic valve replacement (re-SAVR) for high- and intermediate-risk patients with degenerated surgical bioprosthesis. METHODS: All studies comparing multivariate adjustment between ViV TAVI and re-SAVR were screened. The primary end-points were all-cause and cardiovascular (CV) mortality at 30 days and at Midterm follow-up. Short-term complications were the secondary endpoints. RESULTS: We obtained data from 11 studies, encompassing 8570 patients, 4224 undergoing ViV TAVI, and 4346 re-SAVR. Four studies included intermediate-risk patients and seven high-risk patients. 30-day all-cause and CV mortality were significantly lower in ViV (odds ratio [OR] 0.43, 95% confidence intervals [CIs] 0.29-0.64 and OR 0.44, 0.26-0.73 respectively), while after a mean follow-up of 717 (180-1825) days, there was no difference between the two groups (OR 1.04, 0.87-1.25 and OR 1.05, 0.78-1.43, respectively). The risk of stroke (OR 1.03, 0.59-1.82), MI (OR 0.70, 0.34-1.44), major vascular complications (OR 0.92, 0.50-1.67), and permanent pacemaker implantation (OR 0.67, 0.36-1.25) at 30 days did not differ, while major bleedings and new-onset atrial fibrillation were significantly lower in ViV patients (OR 0.41, 0.25-0.67 and OR 0.23, 0.12-0.42, respectively, all 95% CIs). CONCLUSIONS: In high- and intermediate-risk patients with degenerated surgical bioprostheses, ViV TAVI is associated with reduced short-term mortality, compared with re-SAVR. Nevertheless, no differences were found in all-cause and CV mortality at midterm follow-up. PROSPERO CRD42021226488.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
5.
Eur Radiol ; 32(8): 5189-5200, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35192010

RESUMEN

OBJECTIVE: To evaluate the diagnostic accuracy of coronary computed tomography angiography (CCTA) for the evaluation of obstructive coronary artery disease (CAD) in patients referred for transcatheter aortic valve implantation (TAVI). METHODS: EMBASE, PubMed/MEDLINE, and CENTRAL were searched for studies reporting accuracy of CCTA for the evaluation of obstructive CAD compared with invasive coronary angiography (ICA) as the reference standard. QUADAS-2 tool was used to assess the risk of bias. A bivariate random effects model was used to analyze, pool, and plot the diagnostic performance measurements across studies. Pooled sensitivity, specificity, positive ( + LR) and negative (-LR) likelihood ratio, diagnostic odds ratio (DOR), and hierarchical summary ROC curve (HSROC) were evaluated. Prospero registration number: CRD42021252527. RESULTS: Fourteen studies (2533 patients) were included. In the intention-to-diagnose patient-level analysis, sensitivity and specificity for CCTA were 97% (95% CI: 94-98%) and 68% (95% CI: 56-68%), respectively, and + LR and -LR were 3.0 (95% CI: 2.1-4.3) and 0.05 (95% CI: 0.03 - 0.09), with DOR equal to 60 (95% CI: 30-121). The area under the HSROC curve was 0.96 (95% CI: 0.94-0.98). No significant difference in sensitivity was found between single-heartbeat and other CT scanners (96% (95% CI: 90 - 99%) vs. 97% (95% CI: 94-98%) respectively; p = 0.37), whereas the specificity of single-heartbeat scanners was higher (82% (95% CI: 66-92%) vs. 60% (95% CI: 46 - 72%) respectively; p < 0.0001). Routine CCTA in the pre-TAVI workup could save 41% (95% CI: 34 - 47%) of ICAs if a disease prevalence of 40% is assumed. CONCLUSIONS: CCTA proved an excellent diagnostic accuracy for assessing obstructive CAD in patients referred for TAVI; the use of single-heartbeat CT scanners can further improve these findings. KEY POINTS: • CCTA proved to have an excellent diagnostic accuracy for assessing obstructive CAD in patients referred for TAVI. • Routine CCTA in the pre-TAVI workup could save more than 40% of ICAs. • Single-heartbeat CT scanners had higher specificity than others in the assessment of obstructive CAD in patients referred for TAVI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
6.
Catheter Cardiovasc Interv ; 97(5): 755-763, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32478451

RESUMEN

OBJECTIVE: Outcomes of complex percutaneous coronary interventions (PCIs) in older patients are still debated. The aim of the study was to evaluate clinical outcomes of Octogenarian patients treated with ultrathinstents on left main or on coronary bifurcations, compared with younger patients. METHODS: All consecutive patients presenting a critical lesion of an unprotected left main (ULM) or a bifurcation and treated with very thin stents were included in the RAIN (veRy thin stents for patients with left mAIn or bifurcatioN in real life) registry and divided into octogenarians group (OG, 551 patients) and nonoctogenarians (NOGs, 2,453 patients). Major adverse cardiovascular event (MACE), a composite end point of all-cause death, nonfatal myocardial infarction (MI), target lesion revascularization (TLR), and stent thrombosis (ST), was the primary endpoint, while MACE components, cardiovascular (CV) death, and target vessel revascularization (TVR) were the secondary ones. RESULTS: Indication for PCI was acute coronary syndrome in 64.7% of the OG versus 53.1% of the NOG. Severe calcifications and a diffuse disease were significantly more in OG. After a follow-up of 15.2 ± 10.3 months, MACEs were higher in the OG than in the NOG patients (OG 19.1% vs. NOG 11.2%, p < .001), along with MI (OG 6% vs. NOG 3.4%, p = .002) and all-cause death (OG 14% vs. NOG 4.3%, p < .001). In contrast, no significant difference was detected in CV-death (OG 5.1% vs. NOG 4%, p = .871), TVR/TLR, or ST. At multivariate analysis, age was not an independent predictor of MACE (OR 1.02 CI 95% 0.76-1.38), while it was for all-cause death, along with diabetes, GFR < 60 ml/min, and ULM disease. DISCUSSION: Midterm outcomes of complex PCI in OG are similar to those of younger patients. However, due to the higher non-CV death rate, accurate patient selection is mandatory.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Stents , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 98(1): E18-E23, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33315297

RESUMEN

BACKGROUND: Clinical benefits of FFR (Fraction Flow Reserve) driven CABG (Coronary Artery Bypass Graft) remain to be established. METHODS: All randomized controlled trials (RCTs) and observational studies with multivariable adjustement were included. MACE (Major Adverse Cardiac Events) was the primary end point, while its single components (death, myocardial infarction, and total vessel revascularization [TVR]) along with number of anastomoses, on pump procedures and graft occlusion at angiographic follow-up were the secondary ones. Each analysis was stratified for RCTs versus observational studies. RESULTS: Four studies (two RCTs and two observational) were included, enrolling 983 patients, 542 angio-guided and 441 FFR-guided. Mean age was 68.45 years, 79% male, with a mean EuroSCORE I of 2.7. Coronary lesions were located in 37% of patients in the left anterior descending artery, 32% in the circumflex artery, and 26% in the right coronary artery. After a mean follow-up of 40 months, risk of MACE did not differ (OR 0.86 [0.63-1.18]) as that of all cause death (OR 0.86 [0.59-1.25]), MI (OR 0.57 [0.30-1.11]) and TVR (OR 1.10 [0.65-1.85]). FFR-driven CABG reduced on-pump procedures (OR 0.58 [0.35-0.93]) and number of anastomoses (-0.40 [-0.80: -0.01]) while incidence of graft occlusion at follow-up did not differ (OR 0.59 [0.30-1.15], all CI 95%). CONCLUSION: Fraction flow reserve driven CABG reduced the number of anastomoses and of on-pump procedures without increasing risk of MACE and without reducing graft occlusion at angiographic follow-up. ID CRD42020211945.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Anciano , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 97(4): 581-588, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32790145

RESUMEN

BACKGROUND: The optimal antithrombotic regimen in patients with a concomitant indication for oral anticoagulation (OAT) presenting with acute coronary syndrome (ACS) or undergoing percutaneous coronary intervention (PCI) remains unclear. OBJECTIVES: To perform a network meta-analysis of all randomized controlled trials (RCTs) evaluating different antithrombotic regimens among patients with ACS or undergoing PCI requiring OAT. METHODS: Network meta-analysis was performed in a frequentist framework. Antithrombotic regimens were categorized by OAC type (vitamin K antagonist-based [VKA]; non-VKA OAT [NOAC]) and antiplatelet agents (P2Y inhibitor only: dual therapy [DAT]; P2Y plus aspirin: triple therapy [TAT]). Safety outcomes were Thrombolysis in Myocardial Infarction (TIMI) major bleeding and intracranial hemorrhage (ICH). Efficacy outcomes were cardiovascular death, myocardial infarction, stroke and stent-thrombosis (ST). RESULTS: Five RCTs were included, encompassing 10,797 patients (atrial fibrillation 69-100%, ACS 28-62%, PCI 77-100%). Both VKA and NOAC-based DAT regimens reduced the occurrence of TIMI major bleeding compared to VKA TAT (VKA DAT: RR 0.62, 95% CI 0.39-0.98; NOAC DAT: RR 0.52, 95% CI 0.39-0.70). Nevertheless, only NOAC DAT significantly reduced the occurrence of ICH compared to VKA TAT (RR 0.33, 95% CI 0.17-0.64). Ischemic outcomes were similar among the four treatment regimens. However, numerical, potentially clinically important, higher ST occurrence was observed for NOAC DAT as compared to both VKA TAT (1.50, 95% confidence interval [CI] 0.96-2.33) and NOAC TAT (1.86, 95% CI 0.93-3.73). CONCLUSION: DAT regimens present the highest safety profile among antithrombotic strategies, with a NOAC-specific impact on ICH reduction. NOAC DAT might entail clinically important higher ST occurrence, warranting a case-by-case comprehensive evaluation that integrates patient- and procedure-related residual ischemic risk with the patient-specific bleeding risk.


Asunto(s)
Fibrilación Atrial , Intervención Coronaria Percutánea , Anticoagulantes/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrinolíticos/efectos adversos , Humanos , Metaanálisis en Red , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 97(2): E227-E236, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32438488

RESUMEN

BACKGROUND: The PARIS risk score (PARIS-rs) and percutaneous coronary intervention complexity (PCI-c) predict clinical and procedural residual ischemic risk following PCI. Their accuracy in patients undergoing unprotected left main (ULM) or bifurcation PCI has not been assessed. METHODS: The predictive performances of the PARIS-rs (categorized as low, intermediate, and high) and PCI-c (according to guideline-endorsed criteria) were evaluated in 3,002 patients undergoing ULM/bifurcation PCI with very thin strut stents. RESULTS: After 16 (12-22) months, increasing PARIS-rs (8.8% vs. 14.1% vs. 27.4%, p < .001) and PCI-c (15.2% vs. 11%, p = .025) were associated with higher rates of major adverse cardiac events ([MACE], a composite of death, myocardial infarction [MI], and target vessel revascularization), driven by MI/death for PARIS-rs and target lesion revascularization/stent thrombosis for PCI-c (area under the curves for MACE: PARIS-rs 0.60 vs. PCI-c 0.52, p-for-difference < .001). PCI-c accuracy for MACE was higher in low-clinical-risk patients; while PARIS-rs was more accurate in low-procedural-risk patients. ≥12-month dual antiplatelet therapy (DAPT) was associated with a lower MACE rate in high PARIS-rs patients, (adjusted-hazard ratio 0.42 [95% CI: 0.22-0.83], p = .012), with no benefit in low to intermediate PARIS-rs patients. No incremental benefit with longer DAPT was observed in complex PCI. CONCLUSIONS: In the setting of ULM/bifurcation PCI, the residual ischemic risk is better predicted by a clinical risk estimator than by PCI complexity, which rather appears to reflect stent/procedure-related events. Careful procedural risk estimation is warranted in patients at low clinical risk, where PCI complexity may substantially contribute to the overall residual ischemic risk.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Factores de Riesgo , Stents , Resultado del Tratamiento
10.
Am Heart J ; 220: 108-115, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31809991

RESUMEN

BACKGROUND: The risk of recurrent ischemia and bleeding after percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS) may vary during the first year of follow-up according to clinical presentation, and medical and interventional strategies. METHODS: BleeMACS and RENAMI are 2 multicenter registries enrolling patients with ACS treated with PCI and clopidogrel, prasugrel, or ticagrelor. The average daily ischemic and bleeding risks (ADIR and ADBR) in the first year after PCI were the primary end points. The difference between ADBR and ADIR was calculated to estimate the potential excess of bleeding/ischemic events in a given period or specific subgroup. RESULTS: A total of 19,826 patients were included. Overall, in the first year after PCI, the ADBR was 0.008085%, whereas ADIR was 0.008017% (P = .886). In the first 2 weeks ADIR was higher than ADBR (P = .013), especially in patients with ST-segment elevation myocardial infarction or incomplete revascularization. ADIR continued to be, albeit non-significantly, greater than ADBR up to the third month, whereas ADBR became higher, although not significantly, afterward. Patients with incomplete revascularization had an excess in ischemic risk (P = .003), whereas non-ST-segment elevation ACS patients and those on ticagrelor had an excess of bleeding (P = .012 and P = .022, respectively). CONCLUSIONS: In unselected ACS patients, ADIR and ADBR occurred at similar rates within 1 year after PCI. ADIR was greater than ADBR in the first 2 weeks, especially in ST-segment elevation myocardial infarction patients and those with incomplete revascularization. In the first year, ADIR was higher than ADBR in patients with incomplete revascularization, whereas ADBR was higher in non-ST-segment elevation ACS patients and in those discharged on ticagrelor.


Asunto(s)
Síndrome Coronario Agudo/terapia , Hemorragia/epidemiología , Isquemia/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Complicaciones Posoperatorias/epidemiología , Anciano , Clopidogrel/uso terapéutico , Femenino , Hemorragia/etiología , Humanos , Isquemia/etiología , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complicaciones Posoperatorias/etiología , Clorhidrato de Prasugrel/uso terapéutico , Recurrencia , Sistema de Registros , Infarto del Miocardio con Elevación del ST/complicaciones , Infarto del Miocardio con Elevación del ST/terapia , Ticagrelor/efectos adversos , Ticagrelor/uso terapéutico , Factores de Tiempo
11.
Catheter Cardiovasc Interv ; 95(7): 1259-1266, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-31400061

RESUMEN

BACKGROUND: The optimal approach to guide percutaneous coronary intervention (PCI) has yet to be defined. The aim of this study was to compare functional driven (fractional flow reserve) versus intravascular imaging (intravascular ultrasound, IVUS, and/or optical coherence tomography, OCT) versus standard (coronary angiography only, CA)-guided PCI. METHODS: Randomized controlled trials (RCTs) and propensity score weight-matched studies (PSWMs) comparing FFR versus IVUS versus OCT versus CA-guided PCI were included. Major adverse cardiovascular event (MACE; a composite end point of death or myocardial infarction [MI] or revascularization) was the primary endpoint, whereas definite stent thrombosis (ST) and single components of MACE were the secondary ones. Primary analyses were performed including only RCTs, secondary also with PSWMs. RESULTS: Thirty-three studies were included in the analysis, 16 RCTs and 17 PSWMs. After 2 (1-3) years, IVUS performed better for MACE than CA (odds ratio [OR] 0.75 0.52-0.88), whereas there was just a trend for FFR (OR 0.81, 0.64-1.02). These results were mainly driven by reduced risk of all cause death, MI (FFR OR 0.74:0.57-0.99 and IVUS OR 0.82:0.54-0.94) and revascularization. IVUS reduced ST while FFR did not, and at meta-regression analysis, there was a trend for superiority of IVUS versus FFR to reduce subsequent MI in acute coronary syndrome (ACS) patients. The present results were consistent also after adding studies with PSWMs. CONCLUSIONS: Functional and intravascular imaging approaches seem to perform similarly in term of clinical outcomes, while both performed better compared with the standard approach. Imaging showed a potential benefit for ACS patients. The present results stress the need for a wider use of functional or imaging driven PCI.


Asunto(s)
Cateterismo Cardíaco , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Anciano , Cateterismo Cardíaco/efectos adversos , Angiografía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Metaanálisis en Red , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Tomografía de Coherencia Óptica/efectos adversos , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos
12.
Catheter Cardiovasc Interv ; 96(1): E17-E26, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31478334

RESUMEN

AIMS: To establish the value of the SYNTAX Score-II (SS-II) in predicting long-term mortality of patients treated with left main PCI (LM-PCI) using second-generation drug-eluting stents (DES). METHODS AND RESULTS: The SYNTAX score (SS) and the SS-II were calculated in 804 patients included in the FAILS-2 registry (failure in left main study with 2nd generation stents). Patients were classified in low (SS-II ≤33; n = 278, 34.6%), intermediate (SS-II 34-43; n = 260, 32.3%) and high (SS-II ≥44; n = 266, 33.1%) SS-II tertiles. Primary endpoint was all-cause mortality. A significant difference in long-term mortality was noted (5.2 ± 3.6 years): 4.1, 7.5, and 16.7% in low, mid and high SS-II tertiles respectively (p < .001). SS-II score was more accurate in predicting mortality than SS (AUC = 0.73; 95%CI: 0.67-0.79 vs. AUC = 0.55; 95%CI: 0.48-0.63, respectively; p < .001). SS-II led to a reclassification in the risk of all-cause mortality re-allocating 73% of patients from the CABG-only indication to PCI or equipoise PCI-or-CABG indication. Using multiple Cox regression analysis, SS-II (HR: 1.07; 95%CI: 1.05-1.09; p < .001), along with Acute coronary syndrome (ACS) (HR: 1.66; 95%CI: 1.03-2.66; p = .07) and Cardiogenic shock (CS) (HR: 2.82 (95%CI: 1.41-5.64; p = .003) were independent predictors of long-term mortality. SS-II (HR: 1.05; 95%CI: 1.04-1.06; p < .001) along with Insulin dependent Type 2 DM (HR: 1.58, 95%CI: 1.09-2.30.; p < .05), ACS (HR: 1.58, 95%CI: 1.16-2.14; p < .001) and CS (HR: 2.02 95%CI 1.16-3.53; p < .05), were independent predictors of long-term MACE. CONCLUSION: The SS-II was superior to the SS in predicting outcomes associated with contemporary LM-PCI. In this real-world population, two clinical variables not included in the SS-II, ACS and T2DM, were identified as additional markers of poor outcome.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Valor Predictivo de las Pruebas , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 96(3): E248-E256, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32012453

RESUMEN

BACKGROUND: A large trial established the favorable profile of a new polymer-free biolimus A9-eluting stent (PF-BES) with a 1-month dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients. This is the first study comparing outcomes for a 1-month versus longer DAPT strategies following PF-BES-percutaneous coronary intervention (PCI). METHODS: All patients undergoing PF-BES-PCI (January 2016 to July 2018) were included in the multicenter CHANCE registry. Patients were stratified according to DAPT strategy at discharge (planned 1-month vs. planned >1-month). Primary outcomes were the 390-day estimates of a patient-oriented and of a device-oriented composite endpoints (POCE: death, myocardial infarction [MI] or target vessel revascularization; DOCE: cardiac death, target vessel-MI or ischemia-driven target lesion revascularization). Landmark analyses from 1-month post-PCI were carried. RESULTS: Following PF-BES-PCI, 328(40.3%) and 485(59.6%) patients were discharged with 1-month and longer DAPT (12 months [6-12]), respectively. Patients with a previous or index MI were less likely to be discharged on 1-month DAPT. Patients prescribed with 1-month DAPT were more likely to be at HBR than those with longer DAPT (90.2% vs. 69.9%, p = .001). No between-groups differences in the primary outcomes (planned 1-month vs. planned >1-month DAPT: POCE 11.9% vs. 13.2%, p = .747; DOCE: 4.8% vs. 8.1%, p = .500) were observed, also after adjusting for confoundings (POCE: adjusted-hazard ratio [adj-HR] 1.26, 95%CI 0.74-2.13; DOCE: adj-HR 1.00, 95%CI 0.49-1.99). Landmark analyses showed similar results. CONCLUSIONS: In a large all-comers registry of PF-BES PCI, no interaction of planned DAPT strategy (1-month vs. >1-month) with outcomes was found. This observation warrants investigation in adequately powered randomized studies (ClinicalTrials.gov NCT03622203).


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Terapia Antiplaquetaria Doble , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/administración & dosificación , Sirolimus/análogos & derivados , Anciano , Anciano de 80 o más Años , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Esquema de Medicación , Terapia Antiplaquetaria Doble/efectos adversos , Terapia Antiplaquetaria Doble/mortalidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/efectos adversos , Diseño de Prótesis , Sistema de Registros , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 96(1): 1-9, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31860158

RESUMEN

OBJECTIVES: To evaluate the independent clinical impact of stent structural features in a large cohort of patients undergoing unprotected left main (ULM) or coronary bifurcation percutaneous coronary intervention (PCI) with a range of very thin strut stents. BACKGROUND: Clinical impact of structural features of contemporary stents remains to be defined. METHODS: All consecutive patients enrolled in the veRy thin stents for patients with left mAIn or bifurcatioN in real life (RAIN) registry were included. The following stent structural features were studied: antiproliferative drugs (everolimus vs. sirolimus vs. zotarolimus), strut material (platinum-chromium vs. cobalt-chromium), polymer (bioresorbable vs. durable), number of crowns (<8 vs. ≥8) and number of connectors (<3 vs. ≥3). For small diameter stents (≤2.5 mm), struct thickness (74 vs. 80/81 µm) was also tested. Target lesion failure (TLF), a composite of target lesion revascularization and stent thrombosis, was the primary endpoint. Multivariate analysis was performed with Cox regression models. RESULTS: Out of 2,707 patients, 110 (4.1%) experienced a TLF event after 16 months (12-18). After adjustment for confounders, an increased number of connectors (adjusted hazard ratio [adj-HR] 0.62, 95% confidence interval (CI) 0.39-0.99, p = .04) reduced risk of TLF, driven by stents with ≥2.5 mm diameter (HR 0.54, 95% CI 0.32-0.93, p = .02). This independent relationship was lost for stents with diameter <2.5 mm, where only strut thickness appeared to impact. Conversely, no independent relationship of polymer type, number of crowns, and the specific limus-family eluted drug with outcomes was observed. CONCLUSIONS: Among a range of contemporary very thin stent models, an increased number of connectors improved device-related outcomes in this investigated high-risk procedural setting.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
BMC Cardiovasc Disord ; 20(1): 261, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32487051

RESUMEN

BACKGROUND: One out of seven patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) may be affected by transthyretin cardiac amyloidosis (ATTR-CA), mostly presenting with low-flow low-gradient AS with mildly reduced ejection fraction. The complex interaction of these two pathologies poses specific diagnostic and management challenges. The prognostic implications of this clinical intersection are not defined yet. Moreover, whether TAVR may have a prognostic benefit in ATTR-CA patients with symptomatic severe AS remains unclear, posing doubts on the best management strategy in this increasingly recognized subset of patients. CLINICAL CASE: We present a case of an 87-year old man with low-flow low-gradient severe AS, for whom a diagnosis of ATTR-CA was suspected based on clinical and echocardiographic criteria specific to coexisting AS and ATTR-CA. The diagnosis was eventually confirmed by positive bone tracer scintigraphy imaging. Following in-depth Heart team discussion, integrating frailty and prognostic information from combined cardiomyopathy states, a decision was made to manage the patient's severe AS conservatively. CONCLUSION: In the presented case, we deemed the natural history of ATTR-CA amyloidosis to negatively affect both the patient' prognosis and procedural risk, adversing TAVR indication despite symptomatic severe AS. No clear evidence is currently available to guide decision making in this setting, advocating for prospective studies to clarify if TAVR may have a prognostic benefit in ATTR-CA - and which ATTR-CA - patients.


Asunto(s)
Neuropatías Amiloides Familiares/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Cardiomiopatías/complicaciones , Anciano de 80 o más Años , Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/tratamiento farmacológico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/tratamiento farmacológico , Fármacos Cardiovasculares/uso terapéutico , Tratamiento Conservador , Humanos , Masculino , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
16.
N Engl J Med ; 383(1): 88-89, 2020 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-32343497
17.
Catheter Cardiovasc Interv ; 92(7): 1247-1255, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244520

RESUMEN

BACKGROUND: Covered stent (CS) implantation is considered a useful device in the setting of Grade III Coronary Perforation (G3CP), one of the most harmful PCI complication. However, data regarding efficacy of this device and clinical outcomes are still limited. METHODS AND RESULTS: From 1993 to 2015, among 97,779 patients from 9 European centres undergoing PCI, 224 patients had G3CP (0.23%), and 102 patients were managed with CS implantation (96 with PTFE, 6 with pericardium). Device oriented composite endpoint (DOCE), a composite of cardiac death, target lesion revascularization, and stent thrombosis (ST) in-hospital and at long term follow-up were evaluated. G3-CP perforations were successfully sealed with CS in 88 patients (86.3%) with need of intraprocedural pericardiocentesis in one-third of cases. Protamine as heparin reversal agent was administered in 36 (35%) of cases. The cumulative incidence of in-hospital DOCE were 16.6% (17/102): death 14.7%, TLR 2.9%, ST 3.9%. At long-term follow-up (mean 42 ± 38 months), DOCE rates occurred in 19.7%: death 7.4%, TLR 11%, and ST 6.2%. Indication to Dual Antiplatelet Therapy (DAPT) was lifelong in 20% of cases, 1 to 6 months in 22.5% and 12-months in 57.5% without differences in long-term DOCE before and after DAPT interruption (8.0 vs. 6.6%, respectively, P = 0.20). CONCLUSIONS: Use of CS was successful in sealing grade 3 coronary artery perforations in the majority of cases. Beside the high rate of clinical events at short and long-term, ST remains the leading cause of device failure.


Asunto(s)
Vasos Coronarios/lesiones , Lesiones Cardíacas/terapia , Intervención Coronaria Percutánea/instrumentación , Pericardio/trasplante , Politetrafluoroetileno , Stents , Lesiones del Sistema Vascular/terapia , Anciano , Anciano de 80 o más Años , Vasos Coronarios/diagnóstico por imagen , Europa (Continente) , Femenino , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/mortalidad
18.
J Interv Cardiol ; 31(6): 725-730, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30136420

RESUMEN

AIMS: Instantaneous free-wave ratio (iFR) has been recently demonstrated non-inferior to fractional flow reserve (FFR) to drive coronary revascularization; however, no study has compared iFR versus coronary angiography (CA). We performed a network meta-analysis to evaluate efficacy and safety of iFR- versus CA-guided strategy. METHODS AND RESULTS: We searched for randomized trials and studies with propensity score matching in The Cochrane Collaboration Central Register of Controlled Trials, EMBASE, and MEDLINE/Pubmed. CA, FFR, and iFR were the three competitive arms, MACE (a composite endpoint of death, myocardial infarction [MI], and target vessel revascularization [TVR]) was the primary endpoint, while its single components the secondary ones. Subgroup analysis was performed for patients presenting with stable coronary artery disease. Eight studies were selected: 4126 patients were evaluated with FFR, 2160 with iFR, and 2214 with CA, acute coronary syndrome (ACS) was the most frequent admission diagnosis. After 12 months, rates of MACE and all-cause death did not differ between groups (respectively OR 1.04 and OR 0.86 for iFR vs FFR). Both FFR and iFR reduced TVR compared to CA (respectively OR 0.68 and OR 0.70). In patients with stable CAD both FFR and iFR reduced risk of subsequent MI compared to CA (respectively OR 0.66 and OR 0.79). CONCLUSION: Compared to CA alone, both FFR and iFR are safe and effective in guiding coronary revascularization at 12 months. In patients with stable CAD, both FFR and iFR-guided revascularization reduce the risk of subsequent MI at 12 months.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Reserva del Flujo Fraccional Miocárdico/fisiología , Intervención Coronaria Percutánea/métodos , Anciano , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Metaanálisis en Red
19.
Eur Heart J ; 38(42): 3160-3172, 2017 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-29020300

RESUMEN

AIMS: The differential impact on ischaemic and bleeding events of the type of drug-eluting stent [durable polymer stents [DES] vs. biodegradable polymer stents vs. bioresorbable scaffolds (BRS)] and length of dual antiplatelet therapy (DAPT) remains to be defined. METHODS AND RESULTS: Randomized controlled trials comparing different types of DES and/or DAPT durations were selected. The primary endpoint was Major Adverse Cardiovascular Events (MACE) [a composite of death, myocardial infarction (MI), and target vessel revascularization]. Definite stent thrombosis (ST) and single components of MACE were secondary endpoints. The arms of interest were: BRS with 12 months of DAPT (12mDAPT), biodegradable polymer stent with 12mDAPT, durable polymer stent [everolimus-eluting (EES), zotarolimus-eluting (ZES)] with 12mDAPT, EES/ZES with <12 months of DAPT, and EES/ZES with >12 months of DAPT (DAPT > 12 m). Sixty-four studies with 150 arms and 102 735 patients were included. After a median follow-up of 20 months, MACE rates were similar in the different arms of interest. EES/ZES with DAPT > 12 m reported a lower incidence of MI than the other groups, while BRS showed a higher rate of ST when compared to EES/ZES, irrespective of DAPT length. A higher risk of major bleedings was observed for DAPT > 12 m as compared to shorter DAPT. CONCLUSION: Durable and biodegradable polymer stents along with BRS report a similar rate of MACE irrespective of DAPT length. Fewer MI are observed with EES/ZES with DAPT > 12 m, while a higher rate of ST is reported for BRS when compared to EES/ZES, independently from DAPT length. Stent type may partially affect the outcome together with DAPT length.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Implantes Absorbibles , Quimioterapia Combinada , Hemorragia/inducido químicamente , Humanos , Isquemia Miocárdica/terapia , Metaanálisis en Red , Intervención Coronaria Percutánea , Ensayos Clínicos Controlados Aleatorios como Asunto
20.
Catheter Cardiovasc Interv ; 89(6): 1100-1106, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27862874

RESUMEN

BACKGROUND: The risk/benefit balance of transcatheter aortic valve implantation (TAVI) in patients with low-gradient aortic stenosis (LGAS) remains to be well defined. Aim of the study was to investigate the impact of LGAS in patients undergoing TAVI. METHODS: Medline, Cochrane Library, and Scopus were searched for articles reporting outcome of patients with LGAS undergoing TAVI. The primary endpoint was 12-months all-cause mortality and the secondary endpoint was 30-day all-cause mortality. Using event-rates as dependent variable, a meta-regression was performed to test for interaction between baseline clinical features (age, gender, diabetes mellitus, coronary artery disease, left ventricular ejection fraction (LVEF) and type of implanted valve) and transaortic gradient for the primary endpoint. RESULTS: Eight studies with a total of 12,589 patients were included. Almost one-third of the patients presented with LGAS (27.3%: 24.4-29.2). Median LVEF was 48% in patients with LGAS and 56% in patients with high-gradient AS. Patients with LGAS were more likely to have diabetes mellitus, previous coronary artery disease, higher mean Logistic EuroSCORE, and lower EF. At 12 (12-16.6) months, low transaortic gradient emerged as independently associated with all-cause death, both if evaluated as a dichotomous and continuous value (respectively OR 1.17; 1.11-1.23 and OR 1.02; 1-1.04, all CI 95%). Clinical variables, including EF did not affect this result. CONCLUSIONS: In a population of TAVI patients, LGAS appears to be independently related to dismal prognosis. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Oportunidad Relativa , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA