Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Radiology ; 311(2): e231386, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38713023

RESUMEN

Background Limited data are available on radiation segmentectomy (RS) for treatment of hepatocellular carcinoma (HCC) using yttrium 90 (90Y) resin microsphere doses determined by using a single-compartment medical internal radiation dosimetry (MIRD) model. Purpose To evaluate the efficacy and safety of RS treatment of HCC with 90Y resin microspheres using a single-compartment MIRD model and correlate posttreatment dose with outcomes. Materials and Methods This retrospective single-center study included adult patients with HCC who underwent RS with 90Y resin microspheres between July 2014 and December 2022. Posttreatment PET/CT and dosimetry were performed. Adverse events were assessed using the Common Terminology Criteria for Adverse Events, version 5.0. Per-lesion and overall response rates (ie, complete response [CR], objective response, disease control, and duration of response) were assessed at imaging using the Modified Response Evaluation Criteria in Solid Tumors, and overall survival (OS) was assessed using Kaplan-Meier analysis. Results Among 67 patients (median age, 69 years [IQR, 63-78 years]; 54 male patients) with HCC, median tumor absorbed dose was 232 Gy (IQR, 163-405 Gy). At 3 months, per-lesion and overall (per-patient) CR was achieved in 47 (70%) and 41 (61%) of 67 patients, respectively. At 6 months (n = 46), per-lesion rates of objective response and disease control were both 94%, and per-patient rates were both 78%. A total of 88% (95% CI: 79 99) and 72% (95% CI: 58, 90) of patients had a per-lesion and overall duration of response of 1 year or greater. At 1 month, a grade 3 clinical adverse event (abdominal pain) occurred in one of 67 (1.5%) patients. Median posttreatment OS was 26 months (95% CI: 20, not reached). Disease progression at 2 years was lower in the group that received 300 Gy or more than in the group that received less than 300 Gy (17% vs 61%; P = .047), with no local progression in the former group through the end of follow-up. Conclusion Among patients with HCC who underwent RS with 90Y resin microspheres, 88% and 72% achieved a per-lesion and overall duration of response of 1 year or greater, respectively, with one grade 3 adverse event. In patients whose tumors received 300 Gy or more according to posttreatment dosimetry, a disease progression benefit was noted. © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Microesferas , Radioisótopos de Itrio , Humanos , Masculino , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/diagnóstico por imagen , Femenino , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Persona de Mediana Edad , Radioisótopos de Itrio/uso terapéutico , Anciano , Estudios Retrospectivos , Resultado del Tratamiento , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
2.
Eur Radiol ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38483589

RESUMEN

OBJECTIVES: To determine whether international normalized ratio (INR), bilirubin, and creatinine predict bleeding risk following percutaneous liver biopsy. METHODS: A total of 870 consecutive patients (age 53 ± 14 years; 53% (459/870) male) undergoing non-targeted, ultrasound-guided, percutaneous liver biopsy at a single tertiary center from 01/2016 to 12/2019 were retrospectively reviewed. Results were analyzed using descriptive statistics and logistic regression models to evaluate the relationship between individual and combined laboratory values, and post-biopsy bleeding risk. Receiver operating characteristic (ROC) curves and area under ROC (AUC) curves were constructed to evaluate predictive ability. RESULTS: Post-biopsy bleeding occurred in 2.0% (17/870) of patients, with 0.8% (7/870) requiring intervention. The highest INR within 3 months preceding biopsy demonstrated the best predictive ability for post-biopsy bleeding and was superior to the most recent INR (AUC = 0.79 vs 0.61, p = 0.003). Total bilirubin is an independent predictor of bleeding (AUC = 0.73) and better than the most recent INR (0.61). Multivariate regression analysis of the highest INR and total bilirubin together yielded no improvement in predictive performance compared to INR alone (0.80 vs 0.79). The MELD score calculated using the highest INR (AUC = 0.79) and most recent INR (AUC = 0.74) were similar in their predictive performance. Creatinine is a poor predictor of bleeding (AUC = 0.61). Threshold analyses demonstrate an INR of > 1.8 to have the highest predictive accuracy for bleeding. CONCLUSION: The highest INR in 3 months preceding ultrasound-guided percutaneous liver biopsy is associated with, and a better predictor for, post-procedural bleeding than the most recent INR and should be considered in patient risk stratification. CLINICAL RELEVANCE STATEMENT: Despite correction of coagulopathic indices, the highest international normalized ratio within the 3 months preceding percutaneous liver biopsy is associated with, and a better predictor for, bleeding and should considered in clinical decision-making and determining biopsy approach. KEY POINTS: • Bleeding occurred in 2% of patients following ultrasound-guided liver biopsy, and was non-trivial in 41% of those patients who needed additional intervention and had an associated 23% 30-day mortality rate. • The highest INR within 3 months preceding biopsy (AUC = 0.79) is a better predictor of bleeding than the most recent INR (AUC = 0.61). • The MELD score is associated with post-procedural bleeding, but with variable predictive performance largely driven by its individual laboratory components.

3.
Int J Hepatol ; 2024: 8877130, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38274398

RESUMEN

Background and Aims: Nonalcoholic fatty liver disease is the leading cause of chronic liver disease globally and can progress to cirrhosis, liver failure, and liver cancer. Current AASLD, AGA, and ADA guidelines recommend assessment for liver fibrosis in all patients with NAFLD. Serum biomarkers for fibrosis, while widely available, have notable limitations. Imaging-based noninvasive testing for liver fibrosis/cirrhosis is more accurate and is becoming more widespread. Methods: We evaluated the feasibility of a novel shear wave absolute vibroelastography (S-WAVE) modality called Velacur® for assessing liver stiffness measurement (LSM) for fibrosis and attenuation coefficient estimation (ACE) in differentiating patients with chronic liver disease from normal healthy controls. Results: Fifty-four healthy controls and 89 patients with NAFLD or cured HCV with a prior known LSM of >8 kPa were enrolled, and all subjects were evaluated with FibroScan® and Velacur®. Velacur® was able to discriminate patients with increased liver stiffness as determined by a FibroScan® score of >8 kPa from healthy controls with an AUC of 0.938 (0.88-0.96). For assessment of steatosis in NAFLD patients only, Velacur® could identify patients with steatosis from healthy controls with an AUC of 0.831 (0.777-0.880). The Velacur® scan quality assessment was superior in healthy controls, as compared to patients, and the scan quality, as assessed by the quality factor (QF) and interquartile range (IQR)/median, was affected by BMI. Velacur® was safe and well tolerated by patients, and there were no adverse events. Conclusion: Velacur® assessment of liver stiffness measurement and liver attenuation is comparable to results obtained by FibroScan® and is an alternative technology for monitoring liver fibrosis progression in patients with chronic liver disease. This trial is registered with NCT03957070.

4.
Hepatol Commun ; 8(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38517204

RESUMEN

BACKGROUND: As the prevalence of metabolic dysfunction-associated steatotic liver disease increases, it is imperative to have noninvasive alternatives to liver biopsy. Velacur offers a non-invasive, point-of-care ultrasound-based method for the assessment of liver stiffness and attenuation. The aim of this study was to perform a head-to-head comparison of liver stiffness and liver fat determined by Velacur and FibroScan using MRI-based measurements as the reference standard. METHODS: This prospective cross-sectional study included 164 adult participants with well-characterized metabolic dysfunction-associated steatotic liver disease. Patients underwent a research exam including Velacur, FibroScan and contemporaneous magnetic resonance elastography, and magnetic resonance imaging proton density fat fraction (MRI-PDFF) scans. The primary outcome was the presence of advanced fibrosis (>F2) as measured by magnetic resonance elastography and the presence of liver fat (>5%) as measured by MRI-PDFF. RESULTS: The mean age and body mass index were 57±12 years and 30.6±4.8 kg/m2, respectively. The mean liver stiffness on magnetic resonance elastography was 3.22±1.39 kPa and the mean liver fat on MRI-PDFF was 14.2±8%. The liver stiffness assessments by Velacur and FibroScan were similar for the detection of advanced fibrosis (AUC 0.95 vs. 0.97) and were not statistically different (p=0.43). Velacur was significantly better than FibroScan (AUC 0.94 vs. 0.79, p=0.01), for the detection of MRI-PDFF >5% (diagnosis of metabolic dysfunction-associated liver disease). CONCLUSIONS: Velacur was superior to FibroScan for liver fat detection with MRI-PDFF as the reference. Velacur and FibroScan were not statistically different for liver stiffness assessment as defined by magnetic resonance elastography.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Adulto , Humanos , Estudios Transversales , Diagnóstico por Imagen de Elasticidad/métodos , Fibrosis , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA