RESUMEN
The application of hybrid equipments and fused techniques has increasing importance in the field of imaging diagnostics. The biggest advantage of these methods is the simultaneous use of several modalities which can give data about the morphological, functional as well as molecular changes of the different diseases at the same time. The facilities, advantages and the applicability of the SPECT/CT (single photon emission computer tomograph/computer tomograph) are summarized in this paper mainly in oncologic diseases, but also in other disorders. The multimodality equipments showing the function and morphology together increase the specificity and diagnostic accuracy of the nuclear medicine methods and were found to be more efficient in the therapy effectiveness, too.
Asunto(s)
Imagen Multimodal/métodos , Neoplasias/diagnóstico , Neoplasias/metabolismo , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X , Humanos , Neoplasias/radioterapia , Radiofármacos/metabolismo , Planificación de la Radioterapia Asistida por Computador , Receptores Adrenérgicos/metabolismo , Receptores de Somatostatina/metabolismo , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada de Emisión de Fotón Único/normas , Tomografía Computarizada de Emisión de Fotón Único/tendencias , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Tomografía Computarizada por Rayos X/tendencias , Resultado del TratamientoRESUMEN
Recently, the assessment of the muscles using limb MRI and whole body MRI has become widely available and more frequent. In cases of muscular dystrophies it may help to select the optimal muscles for biopsy, because the severely atrophic and degenerated muscles are not suitable for histological tests. It is also known that the pattern of muscle involvement is characteristic for a certain neuromuscular disease, and clinically silent muscle damage can be visualized, as well. Therefore, imaging of muscles is helpful in neuromuscular differential diagnosis and planning genetic tests.
Asunto(s)
Imagen por Resonancia Magnética , Músculos/patología , Enfermedades Neuromusculares/diagnóstico , Biopsia , Diagnóstico Diferencial , Humanos , Atrofia Muscular/patología , Distrofias Musculares/congénito , Distrofias Musculares/diagnóstico , Enfermedades Neuromusculares/patología , Imagen de Cuerpo EnteroRESUMEN
INTRODUCTION/AIMS: Prostheses use for lower limb amputees is difficult, while the socket is hard, the prosthesis is heavy. Drawbacks of conventional prosthesis are mainly associated with the socket, therefore osseointegration technique is a promising solution, since it doesn't require a socket. Our aim was to introduce this technique in Hungary and extend indication for vascular patients. METHODS: The method includes two operative and one rehabilitation phases: during first operation a titanium screw is fixed into the femoral bone marrow cavity, this connects to an abutment, which also penetrates the skin, making a direct connection between the femur and the prosthesis during the second intervention. During rehabilitation the patient makes loading exercises and learns to walk with new prosthesis. RESULTS: This method was launched in Hungary in 2005. Two female amputees were operated on initially, their second surgery was performed in 2006 (when titanium screw was applied in the male patients, as well). Incorporation of titanium screw was exquisite, and rehabilitation was successful. One of our male patients died eight months after his first operation due to myocardial infarction. CONCLUSION: Based on our experiences, the osseointegration technique facilitates rehabilitation of vascular patients for prostheses use. Adequate follow-up and stable vascular diseases are not contraindications, although further clinical trials are needed to determine its indication.
Asunto(s)
Amputación Quirúrgica , Miembros Artificiales , Oseointegración , Enfermedades Vasculares Periféricas/rehabilitación , Enfermedades Vasculares Periféricas/cirugía , Muslo/cirugía , Soporte de Peso , Tornillos Óseos , Terapia por Ejercicio/métodos , Femenino , Fémur , Humanos , Hungría , Masculino , Enfermedades Vasculares Periféricas/fisiopatología , Reoperación , TitanioRESUMEN
When treating pancreatic cancer using standard (ST) 3D conformal radiotherapy (3D-CRT) beam arrangements, the kidneys often receive a higher dose than their probable tolerance limit. Our aim was to elaborate a new planning method that--similarly to IMRT--effectively spares the kidneys without compromising the target coverage. Conformal kidneys sparing (CONKISS) 5-field, noncoplanar plans were compared with ST plans for 23 consecutive patients retrospectively. Optimal beam arrangements were used consisting of a left- and right-wedged beam-pair and an anteroposterior beam inclined in the caudal direction. The wedge direction determination (WEDDE) algorithm was developed to adjust the adequate direction of wedges. The aimed organs at risk (OARs) mean dose limits were: kidney <12 Gy, liver <25 Gy, small bowels <30 Gy, and spinal cord maximum <45 Gy. Conformity and homogeneity indexes with z-test were used to evaluate and compare the different planning approaches. The mean dose to the kidneys decreased significantly (p < 0.05): left kidney 7.7 vs. 10.7 Gy, right kidney 9.1 vs. 11.7 Gy. Meanwhile the mean dose to the liver increased significantly (18.1 vs. 15.0 Gy). The changes in the conformity, homogeneity, and in the doses to other OARs were not significant. The CONKISS method balances the load among the OARs and significantly reduces the dose to the kidneys, without any significant change in the conformity and homogeneity. Using 3D-CRT the CONKISS method can be a smart alternative to IMRT to enhance the possibility of dose escalation.
Asunto(s)
Algoritmos , Riñón/efectos de la radiación , Neoplasias Pancreáticas/radioterapia , Protección Radiológica/métodos , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Simulación por Computador , Humanos , Modelos Biológicos , Dosificación RadioterapéuticaRESUMEN
A pelvic phantom was developed for use in testing image-guided radiation therapy (IGRT) and adaptive applications in radiation therapy (ART) with simulating the anterior-posterior internal organ motions during prostate radiotherapy. Measurements could be done with an ionization chamber (IC) in the simulated prostate. The rectum was simulated by air-equivalent material (AEM). The volume superior to the IC placement was considered as the bladder. The extension of AEM volume could be varied. The vertical position of the IC placement could be shifted by ± 1 cm to simulate the prostate motion parallel to the changes in bladder volume. The reality of the simulation was inspected. Three-millimeter-slice-increment computed tomography (CT) scans were taken for irradiation planning. The structure set was adapted to the phantom from a treated patient. Planning target volume was delineated according to the RTOG 0126 study. IMRT and 3D conformal radiation therapy (3D-CRT) plans were made. Prostate motion and rectum volume changes were simulated in the phantom. IC displacement was corrected by phantom shifting. The delivered dose was measured with IC in 7 cases using intensity-modulated radiation therapy (IMRT) and 3D-CRT fractions, and single square-shaped beams: anteroposterior (AP), posteroanterior (PA), and lateral (LAT). Variations from the calculated doses were slightly below 1% at IMRT and around 1% at 3D-CRT; below 4.5% at square AP beam; up to 9% at square PA beam; and around 0.5% at square LAT beam. Other authors have already shown that by using planning systems and ultrasonic and cone beam CT guidance, correction of organ motions in a real patient during prostate cancer IGRT does not have a significant dosimetric effect. The inspection of our phantom--as described here-ended with similar results. Our team suggested that our model is sufficiently realistic and can be used for IGRT and ART testing.
Asunto(s)
Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Movimiento , Pelvis/efectos de la radiación , Dosificación RadioterapéuticaRESUMEN
PURPOSE: Using three-dimensional conformal radiation therapy (3D-CRT) and multisegmented conformal radiation therapy (MS-CRT) for breast cancer treatment, the dose coverage of the planning target volume (PTV) and the radiation burden on the organs at risk (OARs) were evaluated. MATERIAL AND METHODS: 3D-CRT and MS-CRT were planned for 436 unilateral breasts (217 left). All patients were treated with MS-CRT between 2005 and 2007. For PTV delineation and beam orientation, supportive structures were applied. The mean PTV was 1,130 cm3 (in ten patients > 2,200 cm3). Three-dimensional planning with weight-optimized medial and lateral open fields at a total dose of 50.4/1.8 Gy was followed by multisegmented planning with a reasonably high-dose-level dose cloud to define the medial subfield, and renewed optimization. This was repeated for the lateral subfield with a final optimization. For PTV coverage evaluation, the ICRU 50 was considered: the PTV portions receiving 95-107%, < 95% and > 107% of the prescribed dose (PTVD95- 107%, PTV
Asunto(s)
Neoplasias de la Mama/radioterapia , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos , Carga Corporal (Radioterapia) , Mama/efectos de la radiación , Femenino , Corazón/efectos de la radiación , Humanos , Pulmón/efectos de la radiación , Dosificación RadioterapéuticaRESUMEN
BACKGROUND: The diagnosis of analgesic nephropathy has improved significantly with modern imaging techniques. We reviewed a large portion of the Hungarian dialysis population to obtain additional insight into the problem. METHODS: Twenty-two participating dialysis units enrolled 1400 patients on renal replacement therapy between 1 January 1995 and 1 January 1998. Patients with no known aetiology (n = 284) were interviewed and studied with renal imaging. We assessed the presence of decreased renal mass combined with either bumpy contours, papillary calcification, or both. The subjects studied were interrogated extensively. RESULTS: Our survey suggested analgesic nephropathy in 47 of 1400 patients (3.3%), 3-fold higher than the EDTA database estimate for Hungary. The analgesics most commonly abused were phenacetin-containing mixtures. The driving symptoms were mainly headache and joint pain. Cardiovascular complications were more common than in the rest of the dialysis population, independent of smoking and lipid values (P<0.01). CONCLUSIONS: Phenacetin should be banned. Our study results support the need for longitudinal cohort and case-control studies in Hungary.