Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Heart Vessels ; 35(4): 544-554, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31531717

RESUMEN

We retrospectively assessed the rest-phase images of 300 contrast stress- echocardiograms, during which very-low mechanical index (VLMI) imaging with ultrasound enhancing agents (UEAs) was routinely acquired in addition to greyscale echocardiography; intra- and inter-reader variability for left ventricle (LV) volumes and ejection fraction (LVEF) at rest was established in the overall cohort and normal values were calculated in the subset of subjects with no cardiac risk factors or cardiac disease and a normal stress-echocardiogram. Current recommendations for chamber quantification using echocardiography advise the use of UEAs in case of insufficient quality of endocardial visualization, but normal values for LV volumes and LVEF using UEAs have never been published using currently recommended VLMI method. Single-centre retrospective study, enrolling subjects referred to contrast stress- echocardiography for suspect coronary artery disease, including the acquisition of both standard 2D greyscale and bolus UEAs with VLMI, regardless of the image quality. This enables offline measurement of the LV volumes and LVEF for both greyscale and UEAs-VLMI images at rest in all subjects. Images were allocated to 3 readers in random order. Normal range for LV volumes and LVEF was also derived in a subset of apparently healthy subjects. In the 298 exams finally assessed, measurement variability among the three readers was lower with UEAs-VLMI, in particular for end-systolic volumes (intra-class correlation coefficient for concordance improved from 0.855 to 0.916, for LVEF from 0.68 to 0.783, p < 0.01), intra- observer variability reduced (Lin's correlation coefficient for LVEF from 0.747 to 0.857, p < 0.01). Normal mean indexed LV end-diastolic volume with UEAs-VLMI, compared to greyscale imaging, was + 14 ml/m2, while LVEF was + 5 to + 6% points. This is the largest study specifically addressing UEAs-VLMI imaging and comparing data with standard greyscale imaging; it demonstrates a reduction in measurement variability of LV volumes and LVEF. Normal reference values for VLMI ultrasound are reported for the first time in comparison with greyscale values.


Asunto(s)
Volumen Cardíaco , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Algoritmos , Ecocardiografía de Estrés , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valores de Referencia , Estudios Retrospectivos
2.
Scand J Gastroenterol ; 53(7): 891-894, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29790800

RESUMEN

OBJECTIVES: Jejuno-ileal bypass (JIB) was a kind of bariatric surgery performed from 1960s to 1980s, able to induce sustainable weight loss by creating a surgical short bowel syndrome. MATERIALS AND METHODS: We report a case of an octogenarian woman who underwent in the early eighties this kind of surgery with consequent 40 kg weight loss. After 27 years, she first developed a reversible metabolic cardiomyopathy that began with signs and symptoms of heart failure. Thereafter, she was diagnosed with severe intractable liver insufficiency. RESULTS: Despite her old age, the patient underwent reversal of JIB with consequent early improvement of hepatic function. CONCLUSIONS: This case demonstrate that in case of long-term and life-threatening complications, it is possible to successfully reverse JIB surgery after upto 30 years. The hypothesis on pathophysiology of heart and liver insufficiency are discussed.


Asunto(s)
Insuficiencia Cardíaca/etiología , Derivación Yeyunoileal/efectos adversos , Fallo Hepático/etiología , Obesidad Mórbida/cirugía , Anciano de 80 o más Años , Ecocardiografía Doppler en Color , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Humanos , Pérdida de Peso
3.
G Ital Cardiol (Rome) ; 25(8): 608, 2024 Aug.
Artículo en Italiano | MEDLINE | ID: mdl-39072599

RESUMEN

Pulmonary artery dissection is a rare and fatal disease. Diagnosis is mainly made during autopsy because most patients die suddenly due to pulmonary artery dissection in the pericardium resulting in pericardial tamponade. The optimum management is not clearly defined because of the paucity of cases in the literature. We describe the case of an 81-year-old man, affected by rheumatoid arthritis and with history of aortic valve replacement surgery, who attended an emergency department for non-specific symptoms, started complaining of chest pain rapidly deteriorated into cardiac shock. Computed tomography scan, performed on suspicion of an acute aortic pathology and/or a pulmonary embolism, allowed the identification of pulmonary artery dissection associated with aorto-pulmonary fistula. Despite early diagnosis in the emergency department, the outcome was unfortunately fatal.


Asunto(s)
Disección Aórtica , Arteria Pulmonar , Humanos , Anciano de 80 o más Años , Masculino , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico , Disección Aórtica/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Resultado Fatal , Tomografía Computarizada por Rayos X , Fístula Vascular/cirugía , Fístula Vascular/diagnóstico , Fístula Vascular/diagnóstico por imagen
4.
J Cardiovasc Dev Dis ; 11(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38392266

RESUMEN

BACKGROUND: This case report outlines the presentation of an emerging complication arising from left bundle branch area pacing (LBBAP). CASE SUMMARY: A 43-year-old male with no history of cardiac problems experienced recurrent episodes of syncope with no prodromal symptoms. During monitoring in the emergency department, the patient underwent an episode of asystole, leading to LBBAP implantation. The procedure encountered technical challenges, resulting in an interventricular septal hematoma and subsequent ventricular arrhythmias. Despite initial concerns, conservative management led to resolution, demonstrated through echocardiographic follow-ups. DISCUSSION: This report underscores the significance of ventricular arrhythmias as indicators of interventricular septal hematoma, providing insights into its diagnosis, management, and implications for LBBAP procedures.

5.
J Am Soc Echocardiogr ; 35(10): 1018-1027.e6, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35636619

RESUMEN

BACKGROUND: Reduced global longitudinal strain (GLS) of the left ventricle is associated with adverse prognosis in healthy subjects and in different cardiovascular conditions. Resting GLS may enable risk assessment independently from stress echocardiography (SE). We assessed whether there is an association of GLS measured at rest before SE with long-term outcome, independent of clinical parameters or reversible wall motion abnormalities and Doppler coronary flow velocity reserve. METHODS: Five hundred thirty patients who underwent SE for ischemia evaluation between 2010 and 2012 and who had rest images available were selected. Resting GLS was measured off-line (absolute value <15% was considered abnormal). Cox models were used to examine the association between clinical variables, ejection fraction, SE variables, and resting GLS with mortality and cardiac events (cardiac death and nonfatal myocardial infarction). The independent prognostic value of GLS over known rest and stress variables was assessed. RESULTS: Over a median follow-up of 7.5 years, 137 patients died from any cause and 50 had a nonfatal myocardial infarction. Patients with resting GLS <15% had significantly lower event-free survival (log-rank P < .0001). Resting GLS was significantly associated with risk of all-cause death and hard cardiac events, after adjustment for clinical risk factors, reversible wall motion abnormalities, and coronary flow velocity reserve. Adding resting GLS into a model with clinical, rest, and stress imaging variables significantly increased the model C index (P = .031). CONCLUSIONS: In a large cohort of patients with suspected coronary artery disease referred for SE, resting GLS <15% was independently associated with mortality and hard cardiac events, incremental to SE data. Model discrimination including resting GLS measurement was comparable to discrimination including SE results.


Asunto(s)
Ecocardiografía de Estrés , Infarto del Miocardio , Ecocardiografía de Estrés/métodos , Humanos , Valor Predictivo de las Pruebas , Pronóstico , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Función Ventricular Izquierda
6.
Biomed Res Int ; 2019: 4861951, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31355264

RESUMEN

BACKGROUND: The RITMIA™ app (Heart Sentinel™, Parma, Italy) is a novel application that combined with a wearable consumer-grade chest-strap Bluetooth heart rate monitor, provides automated detection of atrial fibrillation (AF), and may be promising for sustainable AF screening programs, since it is known that prolonged monitoring leads to increased AF diagnosis. OBJECTIVE: The purpose of this study was to examine whether RITMIA™ could accurately differentiate sinus rhythm (SR) from AF compared with gold-standard physician-interpreted 12-lead electrocardiogram (ECG). DESIGN: In this observational prospective study consecutive patients presenting for elective cardioversion (ECV) of AF, from November 2017 to November 2018, were enrolled. Patients underwent paired 12-lead ECG and RITMIA™ recording, both before and after ECV procedure. The RITMIA™ automated interpretation was compared with 12-lead ECG interpreted by the agreement of two cardiologists. The latter were blinded to the results of the App automated diagnosis. Feasibility, sensitivity, specificity, and K coefficient for RITMIA™ automated diagnosis were calculated. RESULTS: A total of 100 consecutive patients were screened and enrolled. Five patients did not undergo ECV due to spontaneous restoration of SR. 95 patients who actually underwent ECV were included in the final analysis. Mean age was 66.2±10.7 years; female patients were 20 (21.1%). There were 190 paired ECGs and RITMIA™ recordings. The RITMIA™ app correctly detected AF with 97% sensitivity, 95.6% specificity, and a K coefficient of 0.93. CONCLUSIONS: The automated RITMIA™ algorithm very accurately differentiated AF from SR before and after elective ECV. The only hardware required by this method is a cheap consumer-grade Bluetooth heart rate monitor of the chest-strap type. This robust and affordable RITMIA™ technology could be used to conduct population-wide screening in patients at risk for silent AF, thanks to the long-term monitoring applicability.


Asunto(s)
Fibrilación Atrial , Cardioversión Eléctrica , Aplicaciones Móviles , Dispositivos Electrónicos Vestibles , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA