Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Diabet Med ; 41(2): e15243, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37845186

RESUMEN

AIMS: The impact of maternal metformin use during pregnancy on fetal, infant, childhood and adolescent growth, development, and health remains unclear. Our objective was to systematically review the available evidence from animal experiments on the effects of intrauterine metformin exposure on offspring's anthropometric, cardiovascular and metabolic outcomes. METHODS: A systematic search was conducted in PUBMED and EMBASE from inception (searched on 12th April 2023). We extracted original, controlled animal studies that investigated the effects of maternal metformin use during pregnancy on offspring anthropometric, cardiovascular and metabolic measurements. Subsequently, risk of bias was assessed and meta-analyses using the standardized mean difference and a random effects model were conducted for all outcomes containing data from 3 or more studies. Subgroup analyses were planned for species, strain, sex and type of model in the case of 10 comparisons or more per subgroup. RESULTS: We included 37 articles (n = 3133 offspring from n = 716 litters, containing n = 51 comparisons) in this review, mostly (95%) on rodent models and 5% pig models. Follow-up of offspring ranged from birth to 2 years of age. Thirty four of the included articles could be included in the meta-analysis. No significant effects in the overall meta-analysis of metformin on any of the anthropometric, cardiovascular and metabolic offspring outcome measures were identified. Between-studies heterogeneity was high, and risk of bias was unclear in most studies as a consequence of poor reporting of essential methodological details. CONCLUSION: This systematic review was unable to establish effects of metformin treatment during pregnancy on anthropometric, cardiovascular and metabolic outcomes in non-human offspring. Heterogeneity between studies was high and reporting of methodological details often limited. This highlights a need for additional high-quality research both in humans and model systems to allow firm conclusions to be established. Future research should include focus on the effects of metformin in older offspring age groups, and on outcomes which have gone uninvestigated to date.


Asunto(s)
Diabetes Mellitus , Metformina , Embarazo , Animales , Femenino , Humanos , Embarazo/efectos de los fármacos , Experimentación Animal , Antropometría , Hipoglucemiantes/efectos adversos , Metformina/efectos adversos , Atención Prenatal , Porcinos , Ratones , Ratas , Modelos Animales , Diabetes Mellitus/tratamiento farmacológico
2.
Diabet Med ; 38(4): e14406, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32961611

RESUMEN

AIM: To describe the prevalence and characteristics of polypharmacy in a Dutch cohort of individuals with type 2 diabetes. METHODS: We included people with type 2 diabetes from the Diabetes Pearl cohort, of whom 3886 were treated in primary care and 2873 in academic care (secondary/tertiary). With multivariable multinomial logistic regression analyses stratified for line of care, we assessed which sociodemographic, lifestyle and cardiometabolic characteristics were associated with moderate (5-9 medications) and severe polypharmacy (≥10 medications) compared with no polypharmacy (0-4 medications). RESULTS: Mean age was 63 ± 10 years, and 40% were women. The median number of daily medications was 5 (IQR 3-7) in primary care and 7 (IQR 5-10) in academic care. The prevalence of moderate and severe polypharmacy was 44% and 10% in primary care, and 53% and 29% in academic care respectively. Glucose-lowering and lipid-modifying medications were most prevalent. People with severe polypharmacy used a relatively large amount of other (i.e. non-cardiovascular and non-glucose-lowering) medication. Moderate and severe polypharmacy across all lines of care were associated with higher age, low educational level, more smoking, longer diabetes duration, higher BMI and more cardiovascular disease. CONCLUSIONS: Severe and moderate polypharmacy are prevalent in over half of people with type 2 diabetes in primary care, and even more in academic care. People with polypharmacy are characterized by poorer cardiometabolic status. These results highlight the significance of polypharmacy in type 2 diabetes.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Polifarmacia , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/tratamiento farmacológico , Enfermedades Cardiovasculares/epidemiología , Estudios de Cohortes , Comorbilidad , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Polifarmacia/estadística & datos numéricos , Prevalencia , Factores Socioeconómicos
3.
Anaesthesia ; 74(7): 929-939, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30821852

RESUMEN

In the peri-operative period, dexamethasone is widely and effectively used for prophylaxis of postoperative nausea and vomiting. The objective of this meta-analysis was to assess the adverse effects of an incidental steroid load of dexamethasone in adult surgical patients. We searched in MEDLINE, Embase, the Cochrane Central Register of Controlled Trials and the Web of Science for randomised controlled trials comparing an incidental steroid load of dexamethasone with a control intervention in adult patients undergoing surgery. Two review authors independently screened studies for eligibility, extracted data and assessed all included studies for bias. Our primary outcomes were postoperative systemic or wound infection, delayed wound healing and glycaemic response within 24 h. We included 37 studies in this meta-analysis. The pooled results found no evidence that dexamethasone increased the risk of a postoperative wound infection, Peto OR (95%CI) 1.01 (0.80-1.27); 4603 participants, 26 studies; I² = 32%; moderate-quality evidence. Whether dexamethasone influenced wound healing was unclear due to the large confidence intervals, Peto OR (95%CI) 0.99 (0.28-3.43); 1072 participants, 8 studies; I² = 0%; low-quality evidence. Dexamethasone produced a mild increase in glucose levels among participants without diabetes during the first 12 h after surgery, mean difference (95%CI) 0.7 mmol.l-1 (0.3-1.2) 10 studies; 595 participants; I² = 50%; low-quality evidence. This article is an abridged version of a Cochrane Review.


Asunto(s)
Dexametasona/efectos adversos , Glucocorticoides/efectos adversos , Complicaciones Posoperatorias/inducido químicamente , Humanos
4.
Diabetes Obes Metab ; 20(3): 749-752, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28940961

RESUMEN

Historically, metformin was withheld before surgery for fear of metformin-associated lactic acidosis. Currently, however, this risk is deemed to be low and guidelines have moved towards the continuation of metformin. We hypothesized that continuing metformin peri-operatively would lower postoperative serum glucose level without an effect on plasma lactate levels. We performed a single-blind multicentre randomized controlled trial in people with type 2 diabetes mellitus scheduled for non-cardiac surgery and continued (MF+ group) or withheld (MF- group) metformin before surgery. The main outcome measures were the differences in peri-operative plasma glucose and lactate levels. We randomized 70 patients (37 MF+ group and 33 MF- group) with type 2 diabetes mellitus. Postoperative glucose levels were similar in the MF+ and the MF- groups (8.2 ± 1.8 vs 8.3 ± 2.3 mmol/L P = .95) Although preoperative lactate levels were slightly higher in the MF+ group compared with the MF- group (1.5 vs 1.2 mmol/L; P = .02), the postoperative lactate levels were not significantly different (1.2 vs 1.0 mmol/L; P = .18). In conclusion, continuation of metformin during elective non-cardiac surgery does not improve glucose control or raise lactate levels to a clinically relevant degree.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Metformina/uso terapéutico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Glucemia/metabolismo , Diabetes Mellitus Tipo 2/sangre , Femenino , Humanos , Cuidados Intraoperatorios , Tiempo de Internación/estadística & datos numéricos , Masculino , Cumplimiento de la Medicación , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Método Simple Ciego , Resultado del Tratamiento , Adulto Joven
5.
Oecologia ; 187(1): 305-318, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29627956

RESUMEN

According to theory, habitat selection by organisms should reflect underlying habitat-specific fitness consequences and, in birds, reproductive success has a strong impact on population growth in many species. Understanding processes affecting habitat selection also is critically important for guiding conservation initiatives. Northern pintails (Anas acuta) are migratory, temperate-nesting birds that breed in greatest concentrations in the prairies of North America and their population remains below conservation goals. Habitat loss and changing land use practices may have decoupled formerly reliable fitness cues with respect to nest habitat choices. We used data from 62 waterfowl nesting study sites across prairie Canada (1997-2009) to examine nest survival, a primary fitness metric, at multiple scales, in combination with estimates of habitat selection (i.e., nests versus random points), to test for evidence of adaptive habitat choices. We used the same habitat covariates in both analyses. Pintail nest survival varied with nest initiation date, nest habitat, pintail breeding pair density, landscape composition and annual moisture. Selection of nesting habitat reflected patterns in nest survival in some cases, indicating adaptive selection, but strength of habitat selection varied seasonally and depended on population density and landscape composition. Adaptive selection was most evident late in the breeding season, at low breeding densities and in cropland-dominated landscapes. Strikingly, at high breeding density, habitat choice appears to become maladaptive relative to nest predation. At larger spatial scales, the relative availability of habitats with low versus high nest survival, and changing land use practices, may limit the reproductive potential of pintails.


Asunto(s)
Ecosistema , Comportamiento de Nidificación , Animales , Aves , Canadá , América del Norte
6.
Anaesthesia ; 73(3): 332-339, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29230803

RESUMEN

In this open-label multicentre randomised controlled trial, we investigated three peri-operative treatment strategies to lower glucose and reduce the need for rescue insulin in patients aged 18-75 years with type-2 diabetes mellitus undergoing non-cardiac surgery. Patients were randomly allocated using a web-based randomisation program to premedication with liraglutide (liraglutide group), glucose-insulin-potassium infusion (insulin infusion group) or insulin bolus regimen (insulin bolus group), targeting a glucose < 8.0 mmol.l-1 . The primary outcome was the between group difference in median glucose levels 1 h after surgery. We analysed 150 patients (liraglutide group n = 44, insulin infusion group n = 53, insulin bolus group n = 53) according to the intention-to-treat principle. Median (IQR [range]) plasma glucose 1 h postoperatively was lower in the liraglutide group compared with the insulin infusion and insulin bolus groups (6.6 (5.6-7.7 [4.2-13.5]) mmol.l-1 vs. 7.5 (6.4-8.3 [3.9-16.6]) mmol.l-1 (p = 0.026) and 7.6 (6.4-8.9 [4.7-13.2]) mmol.l-1 ) p = 0.006, respectively). The incidence of hypoglycaemia and postoperative complications did not differ between the groups. Six patients had pre-operative nausea in the liraglutide group, of which two had severe nausea, compared with no patients in the insulin infusion and insulin bolus groups (p = 0.007). The pre-operative administration of liraglutide stabilised peri-operative plasma glucose levels and reduced peri-operative insulin requirements, at the expense of increased pre-operative nausea rates.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Liraglutida/uso terapéutico , Atención Perioperativa , Anciano , Glucemia/análisis , Diabetes Mellitus Tipo 2/sangre , Femenino , Glucosa/uso terapéutico , Humanos , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad , Potasio/uso terapéutico
7.
J Clin Monit Comput ; 32(5): 953-964, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29218549

RESUMEN

Subcutaneous continuous glucose monitoring (CGM) may have benefits in achieving glycemic control in critically ill patients. The aim of this study was to assess the accuracy and reliability of the FreeStyle Navigator I in critically ill patients and to assess patient related factors influencing the accuracy and reliability. This study is a retrospective analysis of data from a randomized controlled trial conducted in a 20-bed mixed intensive care unit. Analytical accuracy, clinical accuracy and reliability were assessed against arterial blood glucose samples as reference. Assessment was according to recent consensus recommendations with median absolute relative difference (median ARD), Bland-Altman plots, the ISO system accuracy standards (ISO 15197:2013) and Clarke error grid analysis (CEG). We analyzed 2840 paired measurements from 155 critically ill patients. The median ARD of all paired values was 13.3 [6.9-22.1]%. The median ARD was significantly higher in both the hypoglycemic and the hyperglycemic range (32.4 [12.1-53.4]% and 18.7 [10.7-28.3]% respectively, p < 0.001). The Bland-Altman analysis showed a mean bias of - 0.82 mmol/L with a lower limit of agreement (LOA) of - 3.88 mmol/L and an upper LOA of 2.24 mmol/L. A total of 1626 (57.3%) values met the ISO-2013, standards and 1,334 (47%) CGM values were within 12.5% from the reference value. CEG: 71.0% zone A, 25.8% zone B, 0.5% zone C, 2.5% zone D, 0.3% zone E. The median overall real-time data display time was 94.0 ± 14.9% and in 23% of the patients, the sensor measured < 95% of the time. Additionally, data gaps longer than 30 min were found in 48% of the patients. The analytical accuracy of the FreeStyle Navigator I in critically ill patients was suboptimal. Furthermore, the clinical accuracy, did not meet the required standards. The reliability was satisfactory, however, in almost a quarter of the patients the realtime data display was < 95%. The accuracy was considerably and significantly lower in hyper- and hypoglycemic ranges.


Asunto(s)
Glucemia/análisis , Monitoreo Fisiológico/instrumentación , Anciano , Enfermedad Crítica/enfermería , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/enfermería , Monitoreo Fisiológico/estadística & datos numéricos , Reproducibilidad de los Resultados , Estudios Retrospectivos
8.
Diabet Med ; 34(2): 262-271, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27696520

RESUMEN

AIM: To assess the impact on fear of hypoglycaemia and treatment satisfaction with an artificial pancreas system used for 2 consecutive months, as well as participant acceptance of the artificial pancreas system. METHODS: In a randomized crossover trial patient-related outcomes associated with an evening-and-night artificial pancreas and sensor-augmented pump therapy were compared. Both intervention periods lasted 8 weeks. The artificial pancreas acceptance questionnaire (range 0-90, higher scores better), Hypoglycaemia Fear Survey II (range 0-72, higher scores worse) and Diabetes Treatment Satisfaction Questionnaire (range 0-36, higher scores better) were completed by 32 participants. Semi-structured interviews were conducted after study completion in a subset of six participants. Outcomes were compared using a repeated-measures anova model or paired t-test when appropriate. RESULTS: The total artificial pancreas acceptance questionnaire score at the end of the artificial pancreas period was 69.1 (sd 14.7; 95% CI 63.5, 74.7), indicating a positive attitude towards the artificial pancreas. No significant differences were found among the scores at baseline, end of sensor-augmented pump therapy period or end of the artificial pancreas period with regard to fear of hypoglycaemia [28.2 (sd 17.5), 23.5 (sd 16.6) and 23.5 (sd 16.7), respectively; P = 0.099] or diabetes treatment satisfaction [29.0 (sd 3.9), 28.2 (sd 5.2) and 28.0 (sd 7.1), respectively; P = 0.43]. Themes frequently mentioned in the interviews were 'positive effects at work', 'improved blood glucose', 'fewer worries about blood glucose', but also 'frequent alarms', 'technological issues' and 'demand for an all-in-one device'. CONCLUSIONS: The psychological outcomes of artificial pancreas and sensor-augmented pump therapy were similar. Current artificial pancreas technology is promising but user concerns should be taken into account to ensure utility of these systems.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Miedo/psicología , Hipoglucemia/psicología , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Satisfacción del Paciente , Adulto , Glucemia/metabolismo , Estudios Cruzados , Diabetes Mellitus Tipo 1/metabolismo , Femenino , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios
9.
Diabet Med ; 34(11): 1623-1628, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28703888

RESUMEN

AIMS: Individual indicators of socio-economic status have been associated with glycaemic control in people with Type 2 diabetes, but little is known about the association between partner's socio-economic status and HbA1c levels. We therefore examined the cross-sectional association between individual and partner's level of occupation on HbA1c levels in people with Type 2 diabetes in the Netherlands. METHODS: We included people with Type 2 diabetes with a partner who were treated in primary, secondary and tertiary care in the Diabetes Pearl cohort. Occupational level was classified according to International Standard Classification of Occupations (ISCO)-08 skill levels. Linear regression analyses were performed stratified for sex, and corrected for age, recruitment centre and diabetes medication. RESULTS: In total, 3257 participants (59.8% men, mean 62.2±9.4 years) were included. For men, having a partner with an intermediate level of occupation was associated with lower HbA1c levels [e.g. ISCO level 3: -2 mmol/mol (95% CI -4;-1) or -0.2% (95% CI -0.4;-0.1)], compared with having a partner of the highest occupational level (ISCO level 4). In women, having an unemployed partner was associated with higher HbA1c levels [14 mmol/mol (95% CI 6; 22) or 1.3% (95% CI 0.6; 2.0)], compared with having a partner of the highest occupational level. CONCLUSIONS: Partner's occupational status provided additional information on the association between socio-economic status and HbA1c levels in people with Type 2 diabetes. Women seemed to benefit from a partner with a higher occupational status, while men seemed to benefit from a partner with a lower status. Because of the cross-sectional nature of the present study, more research is necessary to explore this association.


Asunto(s)
Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/epidemiología , Hemoglobina Glucada/análisis , Ocupaciones , Esposos , Adulto , Anciano , Anciano de 80 o más Años , Glucemia/análisis , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Ocupaciones/estadística & datos numéricos , Clase Social , Apoyo Social , Esposos/estadística & datos numéricos , Adulto Joven
10.
Diabetes Obes Metab ; 18(1): 34-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26343550

RESUMEN

AIMS: To evaluate the pharmacokinetics and pharmacodynamics of different doses of glucagon administered subcutaneously (s.c.) at different blood glucose levels. METHODS: This study was an open-label, randomized, three-period, cross-over experiment in 6 patients with type 1 diabetes. During each of the three periods, different blood glucose levels were established in four consecutive steps (8, 6, 4 and 2.8 mmol/l) and glucagon was given at each blood glucose level in doses from 0.11 to 0.44 mg and 0.33, 0.66 and 1 mg at the lowest glucose concentration. RESULTS: Maximum glucagon concentration and area under the curve increased with increasing glucagon dose. Maximum glucagon concentration was reached after 10-20 min. Glucagon raised blood glucose in a dose-dependent manner at different baseline blood glucose levels. The median glucose excursion ranged from 2.6 to 6.2 mmol/l. Time to maximum glucose concentration was dose-dependent for the glucagon doses at 2.8 mmol/l, with median values from 40 to 80 min. CONCLUSIONS: Glucagon administered s.c. produces a stable pharmacokinetic and pharmacodynamic response at lower doses than the usual rescue dose and across a range of hypo- to hyperglycaemic blood glucose levels. This supports the use of small glucagon doses in the artificial pancreas to correct and prevent hypoglycaemia.


Asunto(s)
Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucagón/farmacocinética , Hipoglucemiantes/farmacocinética , Adulto , Glucemia/análisis , Estudios Cruzados , Relación Dosis-Respuesta a Droga , Femenino , Fármacos Gastrointestinales/administración & dosificación , Fármacos Gastrointestinales/farmacocinética , Glucagón/administración & dosificación , Técnica de Clampeo de la Glucosa , Humanos , Hipoglucemiantes/administración & dosificación , Masculino , Persona de Mediana Edad
11.
Diabetes Obes Metab ; 18(7): 671-7, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26996542

RESUMEN

AIMS: To assess the performance and safety of an integrated bihormonal artificial pancreas system consisting of one wearable device and two wireless glucose sensor transmitters during short-term daily use at home. METHODS: Adult patients with type 1 diabetes using an insulin pump were invited to enrol in this randomized crossover study. Treatment with the artificial pancreas started with a day and night in the clinical research centre, followed by 3 days at home. The control period consisted of 4 days of insulin pump therapy at home with blinded continuous glucose monitoring for data collection. Days 2-4 were predefined as the analysis period, with median glucose as the primary outcome. RESULTS: A total of 10 patients completed the study. The median [interquartile range (IQR)] glucose level was similar for the two treatments [7.3 (7.0-7.6) mmol/l for the artificial pancreas vs. 7.7 (7.0-9.0) mmol/l for the control; p = 0.123]. The median (IQR) percentage of time spent in euglycaemia (3.9-10 mmol/l) was longer during use of the artificial pancreas [84.7 (82.2-87.8)% for the artificial pancreas vs. 68.5 (57.9-83.6)% for the control; p = 0.007]. Time in hypoglycaemia was 1.3 (0.2-3.2)% for the artificial pancreas and 2.4 (0.4-10.3)% for the control treatment (p = 0.139). Separate analysis of daytime and night-time showed that the improvements were mainly achieved during the night. CONCLUSIONS: The results of this pilot study suggest that our integrated artificial pancreas provides better glucose control than insulin pump therapy in patients with type 1 diabetes at home and that the treatment is safe.


Asunto(s)
Diabetes Mellitus Tipo 1/terapia , Páncreas Artificial , Adolescente , Adulto , Anciano , Glucemia/metabolismo , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Femenino , Glucagón/administración & dosificación , Glucagón/efectos adversos , Servicios de Atención de Salud a Domicilio , Humanos , Hiperglucemia/inducido químicamente , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Sistemas de Infusión de Insulina , Insulinas/administración & dosificación , Insulinas/efectos adversos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Resultado del Tratamiento , Adulto Joven
12.
Diabetes Obes Metab ; 17(5): 445-51, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25376600

RESUMEN

Biosimilar insulins are likely to enter clinical practice in Europe in the near future. It is important that clinicians are familiar with and understand the concept of biosimilarity and how a biosimilar drug may differ from its reference product. The present article provides an overview of biosimilars, the European regulatory requirements for biosimilars and safety issues. It also summarizes the current biosimilars approved in Europe and the key clinical issues associated with the use of biosimilar insulins.


Asunto(s)
Biosimilares Farmacéuticos/normas , Insulinas/normas , Biosimilares Farmacéuticos/uso terapéutico , Medicamentos Genéricos/normas , Europa (Continente) , Humanos , Insulinas/uso terapéutico , Legislación de Medicamentos
13.
Diabetes Obes Metab ; 17(4): 343-9, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25132320

RESUMEN

AIMS: To assess the accuracy and reliability of the two most widely used continuous glucose monitoring (CGM) systems. METHODS: We studied the Dexcom®G4 Platinum (DG4P; Dexcom, San Diego, CA, USA) and Medtronic Paradigm Veo Enlite system (ENL; Medtronic, Northridge, CA, USA) CGM systems, in 24 patients with type 1 diabetes. The CGM systems were tested during 6-day home use and a nested 6-h clinical research centre (CRC) visit. During the CRC visit, frequent venous blood glucose samples were used as reference while patients received a meal with an increased insulin bolus to induce an aggravated postprandial glucose nadir. At home, patients performed at least six reference capillary blood measurements per day. A Wilcoxon signed-rank test was performed using all data points ≥15 min apart. RESULTS: The overall mean absolute relative difference (MARD) value [standard deviation (s.d.)] measured at the CRC was 13.6 (11.0)% for the DG4P and 16.6 (13.5)% for the ENL [p < 0.0002, confidence interval of difference (CI Δ) 1.7-4.3%, n = 530]. The overall MARD assessed at home was 12.2 (12.0)% for the DG4P and 19.9 (20.5)% for the ENL (p < 0.0001, CI Δ = 5.8-8.7%, n = 839). During the CRC visit, the MARD in the hypoglycaemic range [≤3.9 mmol/l (70 mg/dl)], was 17.6 (12.2)% for the DG4P and 24.6 (18.8)% for the ENL (p = 0.005, CI Δ 3.1-10.7%, n = 117). Both sensors showed higher MARD values during hypoglycaemia than during euglycaemia [3.9-10 mmol/l (70-180 mg/dl)]: for the DG4P 17.6 versus 13.0% and for the ENL 24.6 versus 14.2%. CONCLUSIONS: During circumstances of intended use, including both a CRC and home phase, the ENL was noticeably less accurate than the DG4P sensor. Both sensors showed lower accuracy in the hypoglycaemic range. The DG4P was less affected by this negative effect of hypoglycaemia on sensor accuracy than was the ENL.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Hiperglucemia/diagnóstico , Hipoglucemia/diagnóstico , Monitoreo Ambulatorio/instrumentación , Actividades Cotidianas , Adulto , Austria , Investigación Biomédica/instrumentación , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Francia , Humanos , Hiperglucemia/prevención & control , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Inyecciones Subcutáneas , Insulina/administración & dosificación , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Italia , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Países Bajos , Reproducibilidad de los Resultados
14.
Diabetes Obes Metab ; 17(5): 468-76, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25600304

RESUMEN

AIMS: To test in an outpatient setting the safety and efficacy of continuous subcutaneous insulin infusion (CSII) driven by a modular model predictive control (MMPC) algorithm informed by continuous glucose monitoring (CGM) measurement. METHODS: 13 patients affected by type 1 diabetes participated to a non-randomized outpatient 42-h experiment that included two evening meals and overnight periods (in short, dinner & night periods). CSII was patient-driven during dinner & night period 1 and MMPC-driven during dinner&night period 2. The study was conducted in hotels, where patients could move around freely. A CGM system (G4 Platinum; Dexcom Inc., San Diego, CA, USA) and insulin pump (AccuChek Combo; Roche Diagnostics, Mannheim, Germany) were connected wirelessly to a smartphone-based platform (DiAs, Diabetes Assistant; University of Virginia, Charlottesville, VA, USA) during both periods. RESULTS: A significantly lower percentage of time spent with glucose levels <3.9 mmol/l was achieved in period 2 compared with period 1: 1.96 ± 4.56% vs 12.76 ± 15.84% (mean ± standard deviation, p < 0.01), together with a greater percentage of time spent in the 3.9-10 mmol/l target range: 83.56 ± 14.02% vs 62.43 ± 29.03% (p = 0.04). In addition, restricting the analysis to the overnight phases, a lower percentage of time spent with glucose levels <3.9 mmol/l (1.92 ± 4.89% vs 12.7 ± 19.75%; p = 0.03) was combined with a greater percentage of time spent in 3.9-10 mmol/l target range in period 2 compared with period 1 (92.16 ± 8.03% vs 63.97 ± 2.73%; p = 0.01). Average glucose levels were similar during both periods. CONCLUSIONS: The results suggest that MMPC managed by a wearable system is safe and effective during evening meal and overnight. Its sustained use during this period is currently being tested in an ongoing randomized 2-month study.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Adulto , Anciano , Algoritmos , Atención Ambulatoria , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/sangre , Cronoterapia de Medicamentos , Femenino , Humanos , Hipoglucemia/sangre , Masculino , Comidas , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento
15.
Diabet Med ; 31(2): 122-5, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24152416

RESUMEN

Evidence for continuous glucose monitoring is mounting. Meta-analyses consistently show lowering of HbA1c , and the first trial reporting a reduction in severe hypoglycaemic events in patients with hypoglycaemia unawareness has recently been presented. The more recent trials studied larger numbers of patients and may have shown better results because of improved technology. The various combinations of pump and sensor, with automated bolus calculators and low glucose suspend features, make evaluation more challenging from a reimbursement point of view, but evidence seems convincing enough to justify reimbursement for selected patient groups, including those who have shown a substantial improvement in HbA1c during a trial period, and those with hypoglycaemia unawareness who encountered severe hypoglycaemia in the recent past. More data on cost-efficacy are needed.


Asunto(s)
Diabetes Mellitus/sangre , Diabetes Mellitus/economía , Reembolso de Seguro de Salud , Automonitorización de la Glucosa Sanguínea/economía , Automonitorización de la Glucosa Sanguínea/métodos , Análisis Costo-Beneficio , Diabetes Mellitus/tratamiento farmacológico , Práctica Clínica Basada en la Evidencia , Humanos , Insulina/administración & dosificación , Insulina/economía , Sistemas de Infusión de Insulina/economía
17.
Eur J Obstet Gynecol Reprod Biol ; 296: 371-375, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38552506

RESUMEN

OBJECTIVE: The WHO 2013 guidelines recommend screening for gestational diabetes mellitus (GDM) by 3-point oral glucose tolerance test (OGTT). The objective of this retrospective cohort study was to evaluate GDM diagnosed by an isolated high glucose. STUDY DESIGN: We included pregnant women deemed at risk for GDM were offered GDM screening. We examined the records of 1939 consecutively screened pregnancies at two teaching hospitals in Amsterdam during 2016-2020. Using the WHO 2013 diagnostic criteria, we calculated the proportion of GDM cases diagnosed by isolated abnormal glucose values. RESULTS: Among those screened in our high risk cohort, GDM incidence was 31.5%. Of the GDM diagnoses, 57.0% were based on an isolated fasting glucose value, 30.9% based on multiple raised glucose measurements, 7.4% on an isolated raised 2-hour glucose and 4.7% on an isolated raised 1-hour glucose. For 1-hour glucose, the number needed to screen was 67 persons for one additional GDM case. CONCLUSION: The 1-hour glucose in the 3 point OGTT, as suggested by the WHO 2013 guidelines for GDM, contributes only small numbers of GDM cases and a high number needed to screen (67 for 1 additional case in a selective high risk GDM screening strategy), and is likely even less effective in universally screened populations.


Asunto(s)
Glucemia , Diabetes Gestacional , Embarazo , Femenino , Humanos , Prueba de Tolerancia a la Glucosa , Estudios Retrospectivos , Diabetes Gestacional/epidemiología , Organización Mundial de la Salud
18.
Lancet Digit Health ; 6(4): e272-e280, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38443309

RESUMEN

BACKGROUND: Management of insulin administration for intake of carbohydrates and physical activity can be burdensome for people with type 1 diabetes on hybrid closed-loop systems. Bihormonal fully closed-loop (FCL) systems could help reduce this burden. In this trial, we assessed the long-term performance and safety of a bihormonal FCL system. METHODS: The FCL system (Inreda AP; Inreda Diabetic, Goor, Netherlands) that uses two hormones (insulin and glucagon) was assessed in a 1 year, multicentre, prospective, single-arm intervention trial in adults with type 1 diabetes. Participants were recruited in eight outpatient clinics in the Netherlands. We included adults with type 1 diabetes aged 18-75 years who had been using flash glucose monitoring or continuous glucose monitors for at least 3 months. Study visits were integrated into standard care, usually every three months, to evaluate glycaemic control, adverse events, and person-reported outcomes. The primary endpoint was time in range (TIR; glucose concentration 3·9-10·0 mmol/L) after 1 year. The study is registered in the Dutch Trial Register, NL9578. FINDINGS: Between June 1, 2021, and March 2, 2022, we screened 90 individuals and enrolled 82 participants; 78 were included in the analyses. 79 started the intervention and 71 were included in the 12 month analysis. Mean age was 47.7 (SD 12·4) years and 38 (49%) were female participants. The mean preintervention TIR of participants was 55·5% (SD 17·2). After 1 year of FCL treatment, mean TIR was 80·3% (SD 5·4) and median time below range was 1·36% (IQR 0·80-2·11). Questionnaire scores improved on Problem Areas in Diabetes (PAID) from 30·0 (IQR 18·8-41·3) preintervention to 10·0 (IQR 3·8-21·3; p<0·0001) at 12 months and on World Health Organization-Five Well-Being Index (WHO-5) from 60·0 (IQR 44·0-72·0) preintervention to 76·0 (IQR 60·0-80·0; p<0·0001) at 12 months. Five serious adverse events were reported (one cerebellar stroke, two severe hypoglycaemic, and two hyperglycaemic events). INTERPRETATION: Real-world data obtained in this trial demonstrate that use of the bihormonal FCL system was associated with good glycaemic control in patients who completed 1 year of treatment, and could help relieve these individuals with type 1 diabetes from making treatment decisions and the burden of carbohydrate counting. FUNDING: Inreda Diabetic.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Países Bajos , Estudios Prospectivos
19.
Diabet Med ; 30(5): 603-9, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23324032

RESUMEN

AIMS: The Hypoglycemia Fear Survey (HFS)-II Behaviour and Worry subscales were developed to measure behaviours and anxiety related to hypoglycaemia in diabetes. However, previous studies found lower reliability in the HFS Behaviour subscale and inconsistent relationships with glucose control. The purpose of this study was to conduct extensive analyses of the internal structure of the HFS Behaviour subscale's internal structure and its relationships with diabetes outcomes, including HbA1c and episodes of severe hypoglycaemia. METHODS: HFS-II survey data from 1460 adults with Type 1 diabetes were collected from five countries. This aggregated sample underwent exploratory factor analysis and item analysis to determine the internal structure of the survey and subscales. RESULTS: A three-factor solution showed the best fit for the HFS, with two subscales emerging from the HFS Behaviour representing tendencies towards (1) maintenance of high blood glucose and (2) avoidance of hypoglycaemic risks by other behaviours, and a third single HFS Worry subscale. Subscale item analysis showed excellent fit, separation and good point-measure correlations. All subscales demonstrated acceptable (0.75) to excellent (0.94) internal reliability. HbA(1c) correlated with Maintain High Blood Glucose subscale scores, r = 0.14, P < 0.001, and severe hypoglycaemia frequency correlated with all subscales. CONCLUSIONS: The HFS Worry subscale measures one construct of anxiety about various aspects of hypoglycaemia. In contrast, the HFS Behaviour subscale appears to measure two distinct aspects of behavioural avoidance to prevent hypoglycaemia, actions which maintain high blood glucose and other behaviours to avoid hypoglycaemic risk. These results demonstrate the clinical importance of the HFS Behaviour subscales and their differential relationships with measures of diabetes outcome such as HbA1c .


Asunto(s)
Ansiedad , Miedo , Hipoglucemia/psicología , Hipoglucemiantes/efectos adversos , Adulto , Ansiedad/epidemiología , Ansiedad/psicología , Automonitorización de la Glucosa Sanguínea , Miedo/psicología , Femenino , Alemania/epidemiología , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Cooperación del Paciente , Psicometría , Calidad de Vida , Reproducibilidad de los Resultados , Autocuidado , Eslovenia/epidemiología , Encuestas y Cuestionarios , Turquía/epidemiología , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA