Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
AJR Am J Roentgenol ; 221(4): 460-470, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37132550

RESUMEN

BACKGROUND. Estimation of fractional flow reserve from coronary CTA (FFR-CT) is an established method of assessing the hemodynamic significance of coronary lesions. However, clinical implementation has progressed slowly, partly because of off-site data transfer with long turnaround times for results. OBJECTIVE. The purpose of this study was to evaluate the diagnostic performance of FFR-CT computed on-site with a high-speed deep learning-based algorithm with invasive hemodynamic indexes as the reference standard. METHODS. This retrospective study included 59 patients (46 men, 13 women; mean age, 66.5 ± 10.2 years) who underwent coronary CTA (including calcium scoring) followed within 90 days by invasive angiography with invasive fractional flow reserve (FFR) and/or instantaneous wave-free ratio measurements from December 2014 to October 2021. Coronary artery lesions were considered to have hemodynamically significant stenosis in the presence of invasive FFR of 0.80 or less and/or instantaneous wave-free ratio of 0.89 or less. A single cardiologist evaluated the CTA images using an on-site deep learning-based semiautomated algorithm entailing a 3D computational flow dynamics model to determine FFR-CT for coronary artery lesions detected with invasive angiography. Time for FFR-CT analysis was recorded. FFR-CT analysis was repeated by the same cardiologist in 26 randomly selected examinations and by a different cardiologist in 45 randomly selected examinations. Diagnostic performance and agreement were assessed. RESULTS. A total of 74 lesions were identified with invasive angiography. FFR-CT and invasive FFR had strong correlation (r = 0.81) and, in Bland-Altman analysis, bias of 0.01 and 95% limits of agreement of -0.13 to 0.15. FFR-CT had AUC for hemodynamically significant stenosis of 0.975. At a cutoff of 0.80 or less, FFR-CT had 95.9% accuracy, 93.5% sensitivity, and 97.7% specificity. In 39 lesions with severe calcifications (≥ 400 Agatston units), FFR-CT had AUC of 0.991 and at a cutoff of 0.80, 94.7% sensitivity, 95.0% specificity, and 94.9% accuracy. Mean analysis time per patient was 7 minutes 54 seconds. Intraobserver agreement (intraclass correlation coefficient, 0.85; bias, -0.01; 95% limits of agreement, -0.12 and 0.10) and interobserver agreement (intraclass correlation coefficient, 0.94; bias, -0.01; 95% limits of agreement, -0.08 and 0.07) were good to excellent. CONCLUSION. A high-speed on-site deep learning-based FFR-CT algorithm had excellent diagnostic performance for hemodynamically significant stenosis with high reproducibility. CLINICAL IMPACT. The algorithm should facilitate implementation of FFR-CT technology into routine clinical practice.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Aprendizaje Profundo , Reserva del Flujo Fraccional Miocárdico , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Angiografía Coronaria/métodos , Estudios Retrospectivos , Constricción Patológica , Reproducibilidad de los Resultados , Angiografía por Tomografía Computarizada/métodos , Valor Predictivo de las Pruebas , Algoritmos , Estándares de Referencia
2.
Radiol Med ; 120(7): 611-7, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25656039

RESUMEN

PURPOSE: The authors sought to evaluate the effect of model-based iterative reconstruction (MBIR) on the sensitivity of ground-glass nodule (GGN) detection at different dose levels. MATERIALS AND METHODS: Fifty-four artificial GGN were randomly divided into three sets, each positioned in an anthropomorphic phantom. The three sets were evaluated on standard-dose (SD, 350 mA), low-dose (LD, 35 mA) and ultra-low-dose (ULD, 10 mA) CT scans (100 kV, 64 × 0.625 mm, 0.5 s), and each scan was reconstructed twice with filtered back projection (FBP) and MBIR. Three radiologists independently evaluated the scans for GGN presence and size. SD + FBP was considered the reference standard. A region of interest (ROI) was used to calculate signal-to-noise ratio (SNR) and contrast-to-noise ratio normalised to dose (CNRD). McNemar's test, Bland-Altman analysis and t test were used for statistical assessment (p < 0.05). RESULTS: The mean diameter of the 54 GGNs was 9.2 mm (range 3.7-17.3 mm). For the three readers, no statistically significant differences were observed in the sensitivity of GGN detection between LD + MBIR, ULD + MBIR and SD + FBP (p > 0.05). Bland-Altman analysis showed a good reader agreement (±1.5 mm) for GGN size between SD + FBP and ULD + MBIR. For low dose and ultra-low dose, the SNR and CNRD were significantly higher with MBIR (p < 0.0001). The effective dose was 97.1 % lower with ultra-low dose (0.15 mSv) than standard dose (5.15 mSv). CONCLUSIONS: The detection of GGN with MBIR at low-dose and ultra-low-dose CT does not differ significantly from standard-dose CT with FBP in an anthropomorphic phantom.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Modelos Anatómicos , Nódulos Pulmonares Múltiples/diagnóstico por imagen
3.
Acad Radiol ; 31(2): 572-581, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37563023

RESUMEN

RATIONALE AND OBJECTIVES: To demonstrate the feasibility and potential of using a second-generation prototype photon-counting computed tomography (CT) system to provide simultaneous high spatial resolution images and high spectral resolution material information across a range of routine imaging tasks using clinical patient exposure levels. MATERIALS AND METHODS: The photon-counting system employs an innovative silicon-based photon-counting detector to provide a balanced approach to ultra-high-resolution spectral CT imaging. An initial cohort of volunteer subjects was imaged using the prototype photon-counting system. Acquisition technique parameters and radiation dose exposures were guided by routine clinical exposure levels used at the institution. Images were reconstructed in native slice thickness using an early version of a spectral CT reconstruction algorithm Samples of images across a range of clinical tasks were selected and presented for review. RESULTS: Clinical cases are presented across inner ear, carotid angiography, chest, and musculoskeletal imaging tasks. Initial reconstructed images illustrate ultra-high spatial resolution imaging. The fine detail of small structures and pathologies is clearly visualized, and structural boundaries are well delineated. The prototype system additionally provides concomitant spectral information with high spatial resolution. CONCLUSION: This initial study demonstrates that routine imaging at clinically appropriate patient exposure levels is feasible using a novel deep-silicon photon-counting detector CT system. Furthermore, a deep-silicon detector may provide a balanced approach to photon-counting CT, providing high spatial resolution imaging with simultaneous high-fidelity spectral information.


Asunto(s)
Silicio , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Fotones
4.
J Imaging ; 9(3)2023 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-36976116

RESUMEN

We compared the image quality and quantification parameters through bayesian penalized likelihood reconstruction algorithm (Q.Clear) and ordered subset expectation maximization (OSEM) algorithm for 2-[18F]FDG-PET/CT scans performed for response monitoring in patients with metastatic breast cancer in prospective setting. We included 37 metastatic breast cancer patients diagnosed and monitored with 2-[18F]FDG-PET/CT at Odense University Hospital (Denmark). A total of 100 scans were analyzed blinded toward Q.Clear and OSEM reconstruction algorithms regarding image quality parameters (noise, sharpness, contrast, diagnostic confidence, artefacts, and blotchy appearance) using a five-point scale. The hottest lesion was selected in scans with measurable disease, considering the same volume of interest in both reconstruction methods. SULpeak (g/mL) and SUVmax (g/mL) were compared for the same hottest lesion. There was no significant difference regarding noise, diagnostic confidence, and artefacts within reconstruction methods; Q.Clear had significantly better sharpness (p < 0.001) and contrast (p = 0.001) than the OSEM reconstruction, while the OSEM reconstruction had significantly less blotchy appearance compared with Q.Clear reconstruction (p < 0.001). Quantitative analysis on 75/100 scans indicated that Q.Clear reconstruction had significantly higher SULpeak (5.33 ± 2.8 vs. 4.85 ± 2.5, p < 0.001) and SUVmax (8.27 ± 4.8 vs. 6.90 ± 3.8, p < 0.001) compared with OSEM reconstruction. In conclusion, Q.Clear reconstruction revealed better sharpness, better contrast, higher SUVmax, and higher SULpeak, while OSEM reconstruction had less blotchy appearance.

5.
Eur Radiol Exp ; 7(1): 23, 2023 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-37097376

RESUMEN

BACKGROUND: In this study, stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype was compared with a conventional energy-integrating detector CT (EIDCT) system. METHODS: An ex vivo phantom was created, consisting of a 2% agar-water mixture, in which human-resected and stented arteries were individually embedded. Using similar technique parameters, helical scan data was acquired using a novel prototype Si-PCCT and a conventional EIDCT system at a volumetric CT dose index (CTDIvol) of 9 mGy. Reconstructions were made at 502 and 1502 mm2 field-of-views (FOVs) using a bone kernel and adaptive statistical iterative reconstruction with 0% blending. Using a 5-point Likert scale, reader evaluations were performed on stent appearance, blooming and inter-stent visibility. Quantitative image analysis was performed on stent diameter accuracy, blooming and inter-stent distinction. Qualitative and quantitative differences between Si-PCCT and EIDCT systems were tested with a Wilcoxon signed-rank test and a paired samples t-test, respectively. Inter- and intra-reader agreement was assessed using the intraclass correlation coefficient (ICC). RESULTS: Qualitatively, Si-PCCT images were rated higher than EIDCT images at 150-mm FOV, based on stent appearance (p = 0.026) and blooming (p = 0.015), with a moderate inter- (ICC = 0.50) and intra-reader (ICC = 0.60) agreement. Quantitatively, Si-PCCT yielded more accurate diameter measurements (p = 0.001), reduced blooming (p < 0.001) and improved inter-stent distinction (p < 0.001). Similar trends were observed for the images reconstructed at 50-mm FOV. CONCLUSIONS: When compared to EIDCT, the improved spatial resolution of Si-PCCT yields enhanced stent appearance, more accurate diameter measurements, reduced blooming and improved inter-stent distinction. KEY POINTS: • This study evaluated stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype. • Compared to standard CT, Si-PCCT resulted in more accurate stent diameter measurements. • Si-PCCT also reduced blooming artefacts and improved inter-stent visibility.


Asunto(s)
Fotones , Silicio , Humanos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Stents
6.
Eur Radiol ; 22(3): 569-78, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21984448

RESUMEN

OBJECTIVES: To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. METHODS: Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. RESULTS: Estimates for mean relative ED was 7.1 ± 2.1 mSv/100 mAs for TCM and 12.5 ± 5.3 mSv/100 mAs for CTC (P < 0.001). Relative dose reduction at low HR (≤60 bpm) was highest (49 ± 5%) compared to intermediate (60-70 bpm, 33 ± 12%) and high HR (>70 bpm, 29 ± 12%). However lowest ED is achieved at high HR (5.2 ± 1.5 mSv/100 mAs), compared with intermediate (6.7 ± 1.6 mSv/100 mAs) and low (8.3 ± 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. CONCLUSIONS: Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. KEY POINTS: • Monte Carlo simulations allow for individual radiation dose calculations. • ECG-triggered tube current modulation (TCM) can effectively reduce radiation dose. • Slow and regular heart rates allow for highest dose reductions by TCM. • Adaptive pitch accounts for lowest radiation dose at high heart rates. • Women receive higher effective dose than men undergoing spiral coronary CT-angiography.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Método de Montecarlo , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada Espiral/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Electrocardiografía , Femenino , Humanos , Yopamidol/análogos & derivados , Modelos Lineales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores Sexuales
7.
Phys Med ; 81: 86-93, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33445125

RESUMEN

PURPOSE: To assess whether a deep learning image reconstruction algorithm (TrueFidelity) can preserve the image texture of conventional filtered back projection (FBP) at reduced dose levels attained by ASIR-V in chest CT. METHODS: Phantom images were acquired using a clinical chest protocol (7.6 mGy) and two levels of dose reduction (60% and 80%). Images were reconstructed with FBP, ASIR-V (50% and 100% blending) and TrueFidelity (low (DL-L), medium (DL-M) and high (DL-H) strength). Noise (SD), noise power spectrum (NPS) and task-based transfer function (TTF) were calculated. Noise texture was quantitatively compared by computing root-mean-square deviations (RMSD) of NPS with respect to FBP. Four experienced readers performed a contrast-detail evaluation. The dose reducing potential of TrueFidelity compared to ASIR-V was assessed by fitting SD and contrast-detail as a function of dose. RESULTS: DL-M and DL-H reduced noise and NPS area compared to FBP and 50% ASIR-V, at all dose levels. At 7.6 mGy, NPS of ASIR-V 50/100% was shifted towards lower frequencies (fpeak = 0.22/0.13 mm-1, RMSD = 0.14/0.38), with respect to FBP (fpeak = 0.30 mm-1). Marginal difference was observed for TrueFidelity: fpeak = 0.33/0.30/0.30 mm-1 and RMSD = 0.03/0.04/0.07 for L/M/H strength. Values of TTF50% were independent of DL strength and higher compared to FBP and ASIR-V, at all dose and contrast levels. Contrast-detail was highest for DL-H at all doses. Compared to 50% ASIR-V, DL-H had an estimated dose reducing potential of 50% on average, without impairing noise, texture and detectability. CONCLUSIONS: TrueFidelity preserves the image texture of FBP, while outperforming ASIR-V in terms of noise, spatial resolution and detectability at lower doses.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Procesamiento de Imagen Asistido por Computador , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X
8.
Radiology ; 257(1): 158-66, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20851940

RESUMEN

PURPOSE: To determine conversion factors for the new International Commission on Radiological Protection (ICRP) publication 103 recommendations for adult and pediatric patients and to compare the effective doses derived from Monte Carlo calculations with those derived from dose-length product (DLP) for different body regions and computed tomographic (CT) scanning protocols. MATERIALS AND METHODS: Effective dose values for the Oak Ridge National Laboratory phantom series, including phantoms for newborns; 1-, 5-, and 10-year-old children; and adults were determined by using Monte Carlo methods for a 64-section multidetector CT scanner. For each phantom, five anatomic regions (head, neck, chest, abdomen, and pelvis) were considered. Monte Carlo simulations were performed for spiral scanning protocols with different voltages. Effective dose was computed by using ICRP publication 60 and publication 103 recommendations. The calculated effective doses were compared with those derived from the DLP by using previously published conversion factors. RESULTS: In general, conversion factors determined on the basis of Monte Carlo calculations led to lower values for adults with both ICRP publications. Values up to 33% and 32% lower than previously published data were found for ICRP publication 60 and ICRP publication 103, respectively. For pediatric individuals, effective doses based on the Monte Carlo calculations were higher than those obtained from DLP and previously published conversion factors (eg, for chest CT scanning in 5-year-old children, an increase of about 76% would be expected). For children, a variation in conversion factors of up to 15% was observed when the tube voltage was varied. For adult individuals, no dependence on voltage was observed. CONCLUSION: Conversion factors from DLP to effective dose should be specified separately for both sexes and should reflect the new ICRP recommendations. For pediatric patients, new conversion factors specific for the spectrum used should be established.


Asunto(s)
Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X , Factores de Edad , Humanos , Agencias Internacionales , Modelos Estadísticos , Fantasmas de Imagen , Traumatismos por Radiación/prevención & control , Protección Radiológica/métodos , Efectividad Biológica Relativa , Factores Sexuales
9.
EJNMMI Phys ; 7(1): 30, 2020 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-32399647

RESUMEN

INTRODUCTION: Quantitative imaging biomarkers are becoming usual in oncology for assessing therapy response. The harmonization of image quantitation reporting has become of utmost importance due to the multi-center trials increase. The NEMA image quality test is often considered for the evaluation of quantitation and is more accurate with a radioactive solid phantom that reduces variability. The goal of this project is to determine the level of variability among imaging centers if acquisition and imaging protocol parameters are left to the center's preference while all other parameters are fixed including the scanner type. METHODS: A NEMA-IQ phantom filled with radioactive 68Ge solid resin was imaged in five clinical sites throughout Europe. Sites reconstructed data with OSEM and BSREM algorithms applying the sites' clinical parameters. Images were analyzed according with the NEMA-NU2-2012 standard using the manufacturer-provided NEMA tools to calculate contrast recovery (CR) and background variability (BV) for each sphere and the lung error (LE) estimation. In addition, a 18F-filled NEMA-IQ phantom was also evaluated to obtain a gauge for variability among centers when the sites were provided with identical specific instructions for acquisition and reconstruction protocol (the aggregate of data from 12 additional sites is presented). RESULTS: The data using the 68Ge solid phantom showed no statistical differences among different sites, proving a very good reproducibility among the PET center models even if dispersion of data is higher with OSEM compared to BSREM. Furthermore, BSREM shows better CR and comparable BV, while LE is slightly reduced. Two centers exhibit significant differences in CR and BV values for the 18F NEMA NU2-2012 experiments; these outlier results are explained. CONCLUSION: The same PET system type from the various sites produced similar quantitative results, despite allowing each site to choose their clinical protocols with no restriction on data acquisition and reconstruction parameters. BSREM leads to lower dispersion of quantitative data among different sites. A solid radioactive phantom may be recommended to qualify the sites to perform quantitative imaging.

10.
Radiology ; 252(1): 140-7, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19561253

RESUMEN

PURPOSE: To evaluate the potential effectiveness of adaptive collimation in reducing computed tomographic (CT) radiation dose owing to z-overscanning by using dose measurements and Monte Carlo (MC) dose simulations. MATERIALS AND METHODS: Institutional review board approval was not necessary. Dose profiles were measured with thermoluminescent dosimeters in CT dose index phantoms and in an Alderson-Rando phantom without and with adaptive section collimation for spiral cardiac and chest CT protocols and were compared with the MC simulated dose profiles. Additional dose measurements were performed with an ionization chamber for scan ranges of 5-50 cm and pitch factors of 0.5-1.5. RESULTS: The measured and simulated dose profiles agreed to within 3%. By using adaptive section collimation, a substantial dose reduction of up to 10% was achieved for cardiac and chest CT when measurements were performed free in air and of 7% on average when measurements were performed in phantoms. For scan ranges smaller than 12 cm, ionization chamber measurements and simulations indicated a dose reduction of up to 38%. CONCLUSION: Adaptive section collimation allows substantial reduction of unnecessary exposure owing to z-overscanning in spiral CT. It can be combined in synergy with other means of dose reduction, such as spectral optimization and automatic exposure control.


Asunto(s)
Carga Corporal (Radioterapia) , Modelos Biológicos , Radiometría/métodos , Tomografía Computarizada Espiral , Simulación por Computador , Humanos , Dosis de Radiación , Efectividad Biológica Relativa
11.
Med Phys ; 36(11): 4881-9, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19994496

RESUMEN

PURPOSE: Tube current modulation (TCM) is one of the recent developments in multislice CT that has proven to reduce the patient radiation dose without affecting the image quality. Presently established methods and published coefficients for estimating organ doses from the dose measured free in air on the axis of rotation or in the CT dose index (CTDI) dosimetry phantoms do not take into account this relatively new development in CT scanner design and technology. Based on these organ dose coefficients effective dose estimates can be made. The estimates are not strictly valid for CT scanning protocols utilizing TCM. In this study, the authors investigated the need to take TCM into account when estimating organ and effective dose values. METHODS: A whole-body adult anthropomorphic phantom (Alderson Rando) was scanned with a multislice CT scanner (Somatom Definition, Siemens, Forchheim, Germany) utilizing TCM (CareDose4D). Tube voltage was 120 kV, beam collimation 19.2 mm, and pitch 1. A voxelized patient model was used to define the tissues and organs in the phantom. Tube current values as a function of tube angle were obtained from the raw data for each individual tube rotation of the scan. These values were used together with the Monte Carlo dosimetry tool IMPACTMC (VAMP GmbH, Erlangen, Germany) to calculate organ dose values both with and without account of TCM. Angular and longitudinal modulations were investigated separately. Finally, corresponding effective dose conversion coefficients were determined for both cases according to the updated 2007 recommendations of the ICRP. RESULTS: TCM amplitude was greatest in the shoulder and pelvic regions. Consequently, dose distributions and organ dose values for particular cross sections changed considerably when taking angular modulation into account. The effective dose conversion coefficients were up to 11% lower for a single rotation in the shoulder region and 17% lower in the pelvis when taking angular TCM into account. In the head, neck, thorax, and upper abdominal regions, conversion coefficients changed similarly by only 5% or less. Conversion coefficients for estimating effective doses for scans of complete regions, e.g., chest or abdomen, were approximately 8% lower when taking angular and longitudinal TCMs into account. CONCLUSIONS: The authors conclude that for accurate organ and effective dose estimates in individual cross sections in the shoulder or pelvic regions, the angular tube current modulation should be taken into account. In general, using the average of the modulated tube current causes an overestimation of the effective dose.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Humanos , Modelos Biológicos , Método de Montecarlo , Pelvis/diagnóstico por imagen , Fantasmas de Imagen , Radiometría/métodos , Hombro/diagnóstico por imagen , Programas Informáticos
12.
Med Phys ; 36(3): 993-1007, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19378760

RESUMEN

Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) for various diagnostic tasks can be minimized. The authors used cylindrical water phantoms and quasianthropomorphic phantoms of the thorax and the abdomen with inserts of 13 mm diameter mimicking soft tissue, bone, and iodine for simulations and measurements. To provide clearly defined contrasts, these inserts were made of solid water with a 1% difference in density (DD) to represent an energy-independent soft-tissue contrast of 10 Hounsfield units (HU), calcium hydroxyapatite (Ca) representing bone, and iodine (I) representing the typical contrast medium. To evaluate CT of the thorax, an adult thorax phantom (300 x 200 mm2) plus extension rings up to a size of 460 x 300 mm2 to mimic different patient cross sections were used. For CT of the abdomen, we used a phantom of 360 x 200 mm2 and an extension ring of 460 x 300 mm2. The CT scanner that the authors used was a SOMATOM Definition (Siemens Healthcare, Forchheim, Germany) at 80, 100, 120, and 140 kV. Further voltage settings of 60, 75, 90, and 105 kV were available in an experimental mode. The authors determined contrast for the density difference, calcium, and iodine, and noise and 3D dose distributions for the available voltages by measurements. Additional voltage values and monoenergetic sources were evaluated by simulations. The dose-weighted contrast-to-noise ratio (CNRD) was used as the parameter for optimization. Simulations and measurements were in good agreement with respect to absolute values and trends regarding the dependence on energy for the parameters investigated. For soft-tissue imaging, the standard settings of 120-140 kV were found as adequate choices with optimal values increasing for larger cross sections, e.g., for large abdomens voltages higher than 140 kV may be indicated. For bone and iodine imaging the optimum values were generally found at significantly lower voltages of typically below 80 kV. This offers a potential for dose reduction of up to 50%, but demands significantly higher power values in most cases. The authors concluded that voltage settings in CT should be varied more often than is common in practice today and should be chosen not only according to patient size but also according to the substance imaged in order to minimize dose while not compromising image quality. A reduction from 120 to 80 kV, for example, would yield a reduction in patient dose by more than half for coronary CT angiography. The use of lower voltages has to be recommended for contrast medium studies in cardiac and pediatric CT.


Asunto(s)
Tomografía Computarizada por Rayos X/métodos , Adulto , Fenómenos Biofísicos , Tamaño Corporal , Simulación por Computador , Durapatita , Corazón/diagnóstico por imagen , Humanos , Método de Montecarlo , Fantasmas de Imagen , Radiografía Abdominal/métodos , Radiografía Abdominal/estadística & datos numéricos , Radiografía Torácica/métodos , Radiografía Torácica/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Agua
13.
Phys Med Biol ; 53(13): 3551-66, 2008 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-18552416

RESUMEN

Flat-detector computed tomography (FD-CT) scanners provide large irradiation fields of typically 200 mm in the cranio-caudal direction. In consequence, dose assessment according to the current definition of the computed tomography dose index CTDI(L=100 mm), where L is the integration length, would demand larger ionization chambers and phantoms which do not appear practical. We investigated the usefulness of the CTDI concept and practical dosimetry approaches for FD-CT by measurements and Monte Carlo (MC) simulations. An MC simulation tool (ImpactMC, VAMP GmbH, Erlangen, Germany) was used to assess the dose characteristics and was calibrated with measurements of air kerma. For validation purposes measurements were performed on an Axiom Artis C-arm system (Siemens Medical Solutions, Forchheim, Germany) equipped with a flat detector of 40 cm x 30 cm. The dose was assessed for 70 kV and 125 kV in cylindrical PMMA phantoms of 160 mm and 320 mm diameter with a varying phantom length from 150 to 900 mm. MC simulation results were compared to the values obtained with a calibrated ionization chambers of 100 mm and 250 mm length and to thermoluminesence (TLD) dose profiles. The MCs simulations were used to calculate the efficiency of the CTDI(L) determination with respect to the desired CTDI(infinity). Both the MC simulation results and the dose distributions obtained by MC simulation were in very good agreement with the CTDI measurements and with the reference TLD profiles, respectively, to within 5%. Standard CTDI phantoms which have a z-extent of 150 mm underestimate the dose at the center by up to 55%, whereas a z-extent of 600 mm appears to be sufficient for FD-CT; the baseline value of the respective profile was within 1% to the reference baseline. As expected, the measurements with ionization chambers of 100 mm and 250 mm offer a limited accuracy, whereas an increased integration length of 600 mm appeared to be necessary to approximate CTDI(infinity) in within 1%. MC simulations appear to offer a practical and accurate way of assessing conversion factors for arbitrary dosimetry setups using a standard pencil chamber to provide estimates of CTDI(infinity). This would eliminate the need for extra-long phantoms and ionization chambers or excessive amounts of TLDs.


Asunto(s)
Método de Montecarlo , Fantasmas de Imagen , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Calibración , Simulación por Computador , Cabeza , Dosis de Radiación , Radiometría/instrumentación , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/instrumentación , Irradiación Corporal Total
14.
Phys Med ; 24(2): 71-9, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18331808

RESUMEN

This paper reviews current technical approaches to the optimisation of CT practice, i.e. approaches to reduce patient dose to the necessary minimum. The most important step towards this goal appears to be the technology of tube current modulation (TCM), which came into practice in the early 2000s and has become the standard approach recently. Anatomy- or attenuation-based TCM allows for a dose reduction between 10 and 60% as compared to scans with constant tube current. Automatic exposure control (AEC) approaches are the next step; based on TCM technology, AEC adapts the tube current both with the rotation angle alpha (alpha-modulation) and along the z-axis (z-modulation) to achieve a pre-selected image quality level at minimal dose. To pre-select the image quality level, i.e. primarily the pixel noise level, tools for simulation are important to investigate the necessary noise levels pro- and retrospectively for given cases and diagnostic tasks. Respective "dose tutor" approaches have become available recently and are presented. The most recent technical innovation which may lead to substantial dose reduction is the investigation of optimal spectra taking the type of contrast and 3D dose distributions into account. A high potential has been shown especially for pediatric CT and for thoracic CT where dose reduction of a factor of 2 and more is possible when using reduced tube voltages.


Asunto(s)
Tomografía Computarizada por Rayos X/métodos , Biofisica/métodos , Biofisica/tendencias , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/tendencias
15.
Eur J Radiol ; 107: 143-148, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30292259

RESUMEN

OBJECTIVE: To evaluate a dynamic contrast-enhanced CT-protocol and compare this method with standard of care monophasic portovenous CT for detection of colorectal liver metastases. MATERIALS AND METHODS: A dynamic contrast-enhanced CT protocol was developed to detect liver metastasis in patients suffering from colorectal cancer, in clinical practice. The study was approved by the Hospital Ethics Committee. Written informed consent was obtained from all patients. 135 patients were included in this prospective study. All patients were naive to treatment. A dynamic contrast-enhanced CT was performed, followed by routine monophasic portovenous CT of thorax-abdomen-pelvis. 42 of these patients presented with liver metastasis. The number and lesion conspicuity of detected liver metastasis on dynamic contrast-enhanced CT using perfusion maps, was compared to monophasic CT. RESULTS: 135 patients were included, of which 42 presented with metastases to the liver. Dynamic contrast-enhanced CT outperformed portovenous CT for detection as well as conspicuity of colorectal liver metastasis, at a relatively low dose increment. Wilcoxon Signed Rank test had a p-value of 0.016 and <0.001 respectively for detection and conspicuity of colorectal liver metastasis. CONCLUSION: Dynamic contrast-enhanced CT increases the detection of colorectal liver metastasis, especially for lesions smaller than 15 mm, when compared to monophasic portovenous CT. Dynamic contrast-enhanced CT also has the added advantage of improved lesion conspicuity, which can positively influence reader confidence and clinical workflow.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas/diagnóstico por imagen , Adolescente , Adulto , Anciano , Medios de Contraste , Humanos , Neoplasias Hepáticas/secundario , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Estudios Prospectivos , Tomografía Computarizada Espiral/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
16.
Eur J Radiol ; 81(12): 3711-8, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21420812

RESUMEN

PURPOSE: Computed tomography pulmonary angiography (CTPA) is considered as clinical gold standard for diagnosing pulmonary embolism (PE). Whereas conventional CTPA only offers anatomic information, dual energy CT (DECT) provides functional information on blood volume as surrogate of perfusion by assessing the pulmonary iodine distribution. The purpose of this study was to evaluate the feasibility of lung perfusion imaging using a single-tube DECT scanner with rapid kVp switching. MATERIALS AND METHODS: Fourteen patients with suspicion of acute PE underwent DECT. Two experienced radiologists assessed the CTPA images and lung perfusion maps regarding the presence of PE. The image quality was rated using a semi-quantitative 5-point scale: 1 (=excellent) to 5 (=non-diagnostic). Iodine concentrations were quantified by a ROI analysis. RESULTS: Seventy perfusion defects were identified in 266 lung segments: 13 (19%) were rated as consistent with PE. Five patients had signs of PE at CTPA. All patients with occlusive clots were correctly identified by DECT perfusion maps. On a per patient basis the sensitivity and specificity were 80.0% and 88.9%, respectively, while on a per segment basis it was 40.0% and 97.6%, respectively. None of the patients with a homogeneous perfusion map had an abnormal CTPA. The overall image quality of the perfusion maps was rated with a mean score of 2.6 ± 0.6. There was a significant ventrodorsal gradient of the median iodine concentrations (1.1mg/cm(3) vs. 1.7 mg/cm(3)). CONCLUSION: Lung perfusion imaging on a DE CT-system with fast kVp-switching is feasible. DECT might be a helpful adjunct to assess the clinical severity of PE.


Asunto(s)
Algoritmos , Angiografía/métodos , Aumento de la Imagen/métodos , Embolia Pulmonar/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Enfermedad Aguda , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Invest Radiol ; 46(2): 116-23, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20856124

RESUMEN

OBJECTIVES: computed tomography (CT) is considered the method of choice in thoracic imaging for a variety of indications. Sedation is usually necessary to enable CT and to avoid deterioration of image quality because of patient movement in small children. We evaluated a new, subsecond high-pitch scan mode (HPM), which obviates the need of sedation and to hold the breath. MATERIAL AND METHODS: a total of 60 patients were included in this study. 30 patients (mean age, 14 ± 17 month; range, 0-55 month) were examined with a dual source CT system in an HPM. Scan parameters were as follows: pitch = 3.0, 128 × 0.6 mm slice acquisition, 0.28 seconds gantry rotation time, ref. mAs adapted to the body weight (50-100 mAs) at 80 kV. Images were reconstructed with a slice thickness of 0.75 mm. None of the children was sedated for the CT examination and no breathing instructions were given. Image quality was assessed focusing on motion artifacts and delineation of the vascular structures and lung parenchyma. Thirty patients (mean age, 15 ± 17 month; range, 0-55 month) were examined under sedation on 2 different CT systems (10-slice CT, n = 18; 64-slice CT, n = 13 patients) in conventional pitch mode (CPM). Dose values were calculated from the dose length product provided in the patient protocol/dose reports, Monte Carlo simulations were performed to assess dose distribution for CPM and HPM. RESULTS: all scans were performed without complications. Image quality was superior with HPM, because of a significant reduction in motion artifacts, as compared to CPM with 10- and 64-slice CT. In the control group, artifacts were encountered at the level of the diaphragm (n = 30; 100%), the borders of the heart (n = 30; 100%), and the ribs (n = 20; 67%) and spine (n = 6; 20%), whereas motion artifacts were detected in the HPM-group only in 6 patients in the lung parenchyma next to the diaphragm or the heart (P < 0,001). Dose values were within the same range in the patient examinations (CPM, 1.9 ± 0.6 mSv; HPM, 1.9 ± 0.5 mSv; P = 0.95), although z-overscanning increased with the increase of detector width and pitch-value. CONCLUSION: high-pitch chest CT is a robust method to provide highest image quality making sedation or controlled ventilation for the examination of infants, small or uncooperative children unnecessary, whereas maintaining low radiation dose values.


Asunto(s)
Pediatría/métodos , Intensificación de Imagen Radiográfica/instrumentación , Radiografía Torácica/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Factores de Edad , Protección a la Infancia , Preescolar , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Intensificación de Imagen Radiográfica/métodos , Radiografía Torácica/métodos , Estadísticas no Paramétricas , Tomografía Computarizada por Rayos X/métodos
18.
Invest Radiol ; 44(11): 728-33, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19809339

RESUMEN

OBJECTIVES: Chest pain is one of the most frequent symptoms in the emergency department. A variety of different diseases, some of them acutely life threatening, can be the underlying cause. Electrocardiogram (ECG)-gated computed tomography angiography of the thorax has been proposed as a cost and time effective imaging technique for these patients. We describe a new high-pitch scan mode, which has been developed specifically for low-dose ECG-triggered computed tomography angiography using dual source computed tomography (CT). MATERIAL AND METHODS: Twenty-four patients were examined with this technique on a second generation dual source CT system. The scan mode uses a pitch of 3.2 to acquire a spiral CT data set of the complete thorax in less than 1 second with a temporal resolution of 75 ms (scan parameters: 128 x 0.6 mm collimation, 0.28 seconds gantry rotation time, 370 mAs at 100 kV [15 patients] and 320 mAs at 120 kV [9 patients], reconstructed slice thickness 0.6 mm, increment 0.4 mm). Data acquisition was prospectively triggered at 50% to 60% of the RR interval to cover the range over the heart in diastole. A triple phase contrast injection protocol (total volume: 80 mL) was used to optimize enhancement of the pulmonary and systemic arterial vessels. Image quality was evaluated using a 4-point scale (1 = absence of motion artifacts; 2 = slight motion artifacts, fully evaluable; 3 = motion artifacts, but evaluable; 4 = unevaluable) on a per-segment basis. RESULTS: The patients had an average heart rate of 68 +/- 15 bpm (range: 43-111 bpm) during data acquisition. Motion artifact free visualization of the aorta and pulmonary vessels was possible in each case, of 344 coronary artery segments, 242 (70%) had an image quality score of 1, 60 segments (17%) a score of 2, 28 segments (8%) a score of 3, and 14 segments (4%) were rated as "unevaluable." In 17 patients (10 patients with a heart rate < or =60 bpm) all segments were evaluable. The average dose length product was 113 +/- 11 mGy x cm per scan (mean effective dose 1.6 +/- 0.2 mSv) at 100 kV and 229 +/- 31 mGy x cm per scan (mean effective dose 3.2 +/- 0.4 mSv) at 120 kV. CONCLUSION: Our initial results indicate that this high-pitch scan mode allows motion artifact free and accurate visualization of the thoracic vessels, and diagnostic image quality of the coronary arteries in patients with low and stable heart rates at a very low radiation exposure.


Asunto(s)
Algoritmos , Artefactos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Radiografía Torácica/métodos , Técnica de Sustracción , Adulto , Anciano , Anciano de 80 o más Años , Inteligencia Artificial , Análisis por Conglomerados , Gráficos por Computador , Simulación por Computador , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Modelos Estadísticos , Análisis Numérico Asistido por Computador , Proyectos Piloto , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Interfaz Usuario-Computador
19.
Eur Radiol ; 18(4): 759-72, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18066555

RESUMEN

Estimating the dose delivered to the patient in X-ray computed tomography (CT) examinations is not a trivial task. Monte Carlo (MC) methods appear to be the method of choice to assess the 3D dose distribution. The purpose of this work was to extend an existing MC-based tool to account for arbitrary scanners and scan protocols such as multi-slice CT (MSCT) scanners and to validate the tool in homogeneous and heterogeneous phantoms. The tool was validated by measurements on MSCT scanners for different scan protocols under known conditions. Quantitative CT Dose Index (CTDI) measurements were performed in cylindrical CTDI phantoms and in anthropomorphic thorax phantoms of various sizes; dose profiles were measured with thermoluminescent dosimeters (TLD) in the CTDI phantoms and compared with the computed dose profiles. The in-plane dose distributions were simulated and compared with TLD measurements in an Alderson-Rando phantom. The calculated dose values were generally within 10% of measurements for all phantoms and all investigated conditions. Three-dimensional dose distributions can be accurately calculated with the MC tool for arbitrary scanners and protocols including tube current modulation schemes. The use of the tool has meanwhile also been extended to further scanners and to flat-detector CT.


Asunto(s)
Método de Montecarlo , Fantasmas de Imagen , Radiometría/métodos , Tomografía Computarizada por Rayos X/instrumentación , Simulación por Computador , Humanos , Dosis de Radiación , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Protección Radiológica/métodos , Medición de Riesgo , Factores de Riesgo , Dosimetría Termoluminiscente , Tomografía Computarizada por Rayos X/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA