RESUMEN
BACKGROUND: The role of circulating progenitor cells (CPC) in vascular repair following everolimus-eluting stent (EES) implantation is largely unknown. The aim of the study was to investigate the relationship between temporal variation in CPC levels following EES implantation and the degree of peri-procedural vascular damage, and stent healing, as measured by optical coherence tomography (OCT).MethodsâandâResults: CPC populations (CD133+/KDR+/CD45low) included patients with stable coronary artery disease undergoing stent implantation, and were evaluated using a flow cytometry technique both at baseline and at 1 week. OCT evaluation was performed immediately post-implantation to quantify the stent-related injury and at a 9-month follow up to assess the mid-term vascular response. Twenty patients (mean age 66±9 years; 80% male) with EES-treated stenoses (n=24) were included in this study. Vascular injury score was associated with the 1-week increase of CD133+/KDR+/CD45low (ß 0.28 [95% CI 0.15; 0.41]; P<0.001) and with maximum neointimal thickness at a 9-month follow up (ß 0.008 [95% CI 0.0004; 0.002]; P=0.04). Inverse relationships between numbers of uncoated and apposed struts for the 9-month and the 1-week delta values of CD133+/KDR+/CD45low (ß -12.53 [95% CI -22.17; -2.90]; P=0.011), were also found. CONCLUSIONS: The extent of vessel wall injury influences early changes in the levels of CPC and had an effect on mid-term vascular healing after EES implantation. Early CPC mobilisation was associated with mid-term strut coverage.
Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Anciano , Vasos Coronarios , Stents Liberadores de Fármacos/efectos adversos , Everolimus , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neointima , Intervención Coronaria Percutánea/efectos adversos , Sirolimus , Tomografía de Coherencia Óptica , Resultado del TratamientoRESUMEN
BACKGROUND: Percutaneous coronary intervention (PCI) of left main (LM) disease in patients with cardiogenic shock (CS) represents a clinical challenge. Evidence on clinical outcomes according to revascularization strategies in this scenario remains scarce. The objective was to investigate the short-term outcomes according to treatment strategies for this population. METHODS: We retrospectively analyzed 78 consecutive patients who underwent PCI of LM in established CS at two experienced centers. Characteristics of PCI and short-term clinical outcomes were assessed. RESULTS: LM stenosis was considered the culprit lesion in 49 patients (62.8%). In the remaining cases, LM stenosis was treated after successful PCI of the culprit vessel because of persistent CS. The majority of patients presented complex coronary anatomy (43.6% had Syntax score > 32). Complete revascularization was performed in 34.6%; a 2-stents technique in the LM bifurcation was used in 12.8% and intra-aortic balloon pump (IABP) in 73.1%. In-hospital mortality was 48.7%. At 90 days follow-up it was 50% without differences between 1 or 2 stent LM bifurcation-techniques (p = .319). Mortality was higher in patients with partial revascularization and residual Syntax score ≥ 15 (p < .05 by univariate analysis), and in those with TIMI flow<3 in the left coronary artery at the end of PCI (p < .05 by multivariate analysis). There were no significant differences in the use of IABP in relation to 90-day mortality (p = .92). CONCLUSIONS: In patients presenting with cardiogenic shock and LM disease, neither 2-stents strategy in the LM nor use of IABP displayed a reduced short-term mortality. However, patients with final TIMI flow <3 presented higher short-term mortality in our series.
Asunto(s)
Estenosis Coronaria/terapia , Contrapulsador Intraaórtico , Intervención Coronaria Percutánea , Choque Cardiogénico/terapia , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Estenosis Coronaria/fisiopatología , Femenino , Mortalidad Hospitalaria , Humanos , Contrapulsador Intraaórtico/efectos adversos , Contrapulsador Intraaórtico/mortalidad , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/mortalidad , Choque Cardiogénico/fisiopatología , España , Stents , Factores de Tiempo , Resultado del TratamientoRESUMEN
OBJECTIVES: Our purpose was to describe the prevalence, distribution, extension, and prognostic value of coronary artery disease (CAD) in patients resuscitated from sudden cardiac arrest (SCA) with non-diagnostic electrocardiogram (ECG). BACKGROUND: The impact of CAD and the indication for cardiac catheterization (CC) in patients resuscitated from SCA with non-diagnostic ECG are uncertain. METHODS: We included prospectively and consecutively 545 patients resuscitated from SCA with at least one CC during hospitalization. From them, 203 patients with a non-diagnostic ECG formed our study population. Patients were followed-up 5 years after discharge. RESULTS: Overall, 125 (61.6%) patients had significant CAD, and at least one acute culprit lesion was found in 25 (12.4%). Regarding the burden and complexity of CAD, 78 (38.4%) patients had a CAD Prognostic Index of 0 and a SYNTAX score of 0. There was higher 5-year mortality only in patients with very high burden of CAD: three vessels with severe stenosis (P = 0.015) and CAD Prognostic Index Score ≥ 56 (P < 0.001). Tertiles of SYNTAX score did not predict higher 5-year mortality. CONCLUSIONS: In survivors from SCA with a non-diagnostic ECG, significant CAD is highly prevalent. SYNTAX score was not associated with a different long-term prognosis in this patient population. Patients with severe disease in the three main coronary vessels and patients with higher (≥56) CAD Prognostic Index Score had a worse long-term prognosis.
Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Resucitación , Anciano , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Bases de Datos Factuales , Muerte Súbita Cardíaca/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico , Estudios Prospectivos , Resucitación/efectos adversos , Resucitación/mortalidad , Medición de Riesgo , Factores de Riesgo , España/epidemiología , Factores de TiempoRESUMEN
BACKGROUND: Long-term outcomes of diabetic patients suffering from ST-segment elevation myocardial infarction (STEMI) and treated with second-generation drug-eluting stent have been scarcely evaluated. The aim of this posthoc subanalysis of the EXAMINATION trial was to compare 5-year outcomes according to the presence of diabetes mellitus. METHODS: From a total of 1,497 patients included in the trial, 258 were diabetics (n = 137, received everolimus-eluting stent (EES) and n = 121 bare-metal stent (BMS); whereas 1,239 were nondiabetics (n = 613 treated with EES and n = 626 with BMS). Patient-oriented combined endpoint (POCE) defined as all-cause death, any MI or any revascularization, and other clinical parameters were collected up to 5-years. All results were adjusted for various potential confounders. RESULTS: At 5-years, patients with diabetes showed similar rates of POCE between diabetics treated with EES and those treated with BMS (32.8% vs. 32.2%; p = 0.88). However, rates of TLR were significantly lower in the EES group (4.4% vs. 9.9%; HR 0.52 (0.29-0.94); P = 0.03). In non-diabetics, the use of EES was associated with a significant improvement in all-clinical parameters except for MI rate: POCE: [10.0% vs. 12.6%; HR 0.78(0.62-0.98); P = 0.038], all cause death: [7.0% vs. 12.1%; HR 0.62(0.42-0.90); P = 0.014], and [TLR: 4.2 vs. 6.7; HR 0.60 (0.37-0.98); P = 0.04]. Overall, diabetics showed higher rate of POCE at 5-years (32.6% vs. 21.5% in nondiabetics HR1.45[1.03-2.04];p = 0.03) driven by increased rates of MI and the need for revascularization that occurred in coronary segments remote from target lesions [2.7% vs. 1.1%; HR: 2.27 (1.12-5.23); P = 0.02 and 14% vs. 6.2%; HR: 2.11 (1.38-3.22); P = 0.001, respectively]. CONCLUSIONS: Diabetics had worse clinical outcomes than nondiabetics after STEMI mainly due to atherosclerosis progression. At 5-years, the treatment with EES did not reduce the rate of POCE in diabetics but reduced the need for revascularization compared with BMS.
Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus/epidemiología , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/terapia , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/epidemiología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Stents Liberadores de Fármacos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Recurrencia , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/mortalidad , España/epidemiología , Factores de Tiempo , Resultado del TratamientoRESUMEN
Aims: Techniques for identifying specific microcirculatory structural changes are desirable. As such, capillary rarefaction constitutes one of the earliest changes of cardiac allograft vasculopathy (CAV) in cardiac allograft recipients, but its identification with coronary flow reserve (CFR) or intracoronary resistance measurements is hampered because of non-selective interrogation of the capillary bed. We therefore investigated the potential of wave intensity analysis (WIA) to assess capillary rarefaction and thereby predict CAV. Methods and results: Fifty-two allograft patients with unobstructed coronary arteries and normal left ventricular (LV) function were assessed. Adequate aortic pressure and left anterior descending artery flow measurements at rest and with intracoronary adenosine were obtained in 46 of which 2 were lost to follow-up. In a subgroup of 15 patients, simultaneous RV biopsies were obtained and analysed for capillary density. Patients were followed up with 1-3 yearly screening angiography. A significant relationship with capillary density was noted with CFR (r = 0.52, P = 0.048) and the backward decompression wave (BDW) (r = -0.65, P < 0.01). Over a mean follow-up of 9.3 ± 5.2 years patients with a smaller BDW had an increased risk of developing angiographic CAV (hazard ratio 2.89, 95% CI 1.12-7.39; P = 0.03). Additionally, the index BDW was lower in those who went on to have a clinical CAV-events (P = 0.04) as well as more severe disease (P = 0.01). Conclusions: Within cardiac transplant patients, WIA is able to quantify the earliest histological changes of CAV and can predict clinical and angiographic outcomes. This proof-of-concept for WIA also lends weight to its use in the assessment of other disease processes in which capillary rarefaction is involved.
Asunto(s)
Trasplante de Corazón , Rarefacción Microvascular/diagnóstico por imagen , Adulto , Anciano , Biopsia , Velocidad del Flujo Sanguíneo/fisiología , Capilares/patología , Angiografía Coronaria/métodos , Circulación Coronaria/fisiología , Femenino , Estudios de Seguimiento , Humanos , Flujometría por Láser-Doppler/métodos , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Miocardio/patología , Complicaciones Posoperatorias/diagnóstico por imagen , Periodo Posoperatorio , Pronóstico , Adulto JovenRESUMEN
BACKGROUND: At present, there are no objective data specifically examining the clinical impact of variations in exercise capacity post-transcatheter aortic valve replacement (TAVR). We describe the changes in exercise capacity between baseline and 6 months post-TAVR, and ascertain factors associated with and clinical implications of a lack of improvement in exercise capacity post-TAVR. METHODS: A total of 305 patients (mean age, 79±9 years; 44% men; Society of Thoracic Surgeons predicted risk mortality score, 6.7±4.2%) undergoing TAVR completed both baseline and follow-up exercise capacity assessments at 6 months post-TAVR. Exercise capacity was evaluated by the 6-minute walk test (6MWT). Clinical outcomes were compared between patients displaying greater than (n=152; improving group) versus less than (n=153; nonimproving group) the median percentage change in distance walked between baseline and 6-month follow-up examinations. The primary outcome measure was clinical event rates, measured from the 6-month post-TAVR period onward. Further dichotomization according to baseline 6MWT distance (less than versus more than median walking distance, or slow walker versus fast walker) was also assessed. RESULTS: The mean overall distances walked pre- and post-TAVR (6 months post-TAVR) were 204±119 and 263±116 m, respectively (Δ6MWT=60±106 m), with 219 (72%) patients demonstrating an increase in their walking distance (median percentage increase of the entire population was 20% [interquartile range, 0%-80%]). Factors independently correlated with reduced exercise capacity improvement included a range of baseline clinical characteristics (older age, female sex, chronic obstructive pulmonary disease; P<0.05 for all), periprocedural major or life-threatening bleeding (P=0.009) and new-onset anemia at 6 months post-TAVR (P=0.009). Failure to improve the 6MWT distance by at least 20% was independently associated with all-cause mortality (P=0.002) and cardiovascular death or rehospitalization for cardiovascular causes (P=0.001). Baseline slow walkers who were able to improve the 6MWT distance presented with significantly better outcomes than nonimprovers (P=0.01 for all-cause mortality; P=0.001 for cardiovascular end point). CONCLUSIONS: Approximately one-third of patients undergoing TAVR did not improve their exercise capacity postprocedure. The lack of functional improvement post-TAVR was predicted by a mix of baseline and periprocedural factors translating into poorer clinical outcomes. These results suggest that systematically implementing exercise capacity assessment pre- and post-TAVR may help to improve patient risk stratification.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Terapia por Ejercicio , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/terapia , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Análisis Multivariante , Pronóstico , Análisis de Supervivencia , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del TratamientoRESUMEN
BACKGROUND: In patients with heart failure, interventions to reduce elevated left atrial pressure improve symptoms and reduce the risk of hospital admission. We aimed to assess the safety and potential efficacy of therapeutic left-to-right interatrial shunting in patients with heart failure with reduced ejection fraction. METHODS: We did this proof-of-principle cohort study at one centre in Canada. Patients (aged ≥18 years) with New York Heart Association (NYHA) class III chronic heart failure with reduced ejection fraction were enrolled under the Canadian special access programme. Shunt implants were done after transseptal catheterisation with transoesophageal echocardiographic guidance under general anaesthesia. Patients had clinical and echocardiography evaluations at baseline and months 1 and 3 after shunt implantation. FINDINGS: Between Oct 10, 2013, and March 27, 2015, we enrolled ten patients. The device was successfully implanted in all patients; no device-related or procedural adverse events occurred during follow-up. Transoesophageal echocardiography at 1 month showed that all shunts were patent, with no thrombosis or migration. From baseline to 3 month follow-up, we recorded improvements in NYHA classification (from class III to class II in seven [78%] of nine patients, from class III to class I in one [11%] patient, and no change in one [11%] patient; p=0·0004); quality of life, as assessed by the Duke Activity Status Index (from a mean score of 13 [SD 6·2] to 24·8 [12·9]; p=0·016) and the Kansas City Cardiomyopathy Questionnaire (from a mean score of 44·3 [SD 9·8] to 79·1 [13·0]; p=0·0001); and 6 min walk test distance (from a mean of 244 m [SD 112] to 318 m [134]; p=0·016). Pulmonary capillary wedge pressure was reduced from a mean of 23 mm Hg (SD 5) at baseline to 17 mm Hg (8) at 3 months (p=0·035), with no changes in right atrial pressure, pulmonary arterial pressure, or pulmonary resistance. No patient was admitted to hospital for worsening heart failure. One (10%) patient was admitted to hospital with gastrointestinal bleeding at month 1; one (10%) patient died after incessant ventricular tachycardia storm, which led to terminal heart failure 2 months post-procedure. INTERPRETATION: This first-in-man experience with an implanted left-to-right interatrial shunt demonstrates initial safety and early beneficial clinical and haemodynamic outcomes in patients with heart failure with reduced ejection fraction. Further large-scale randomised studies are warranted. FUNDING: V-Wave.
Asunto(s)
Insuficiencia Cardíaca/cirugía , Canadá , Procedimientos Quirúrgicos Cardíacos/métodos , Estudios de Cohortes , Femenino , Atrios Cardíacos/cirugía , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Prótesis e Implantes , Diseño de Prótesis , Volumen SistólicoRESUMEN
OBJECTIVES: To evaluate the feasibility, safety, and efficacy of direct transcatheter aortic valve replacement (TAVR), that is, TAVR without balloon predilation (BPD), by performing a systematic review and meta-analysis of available evidence. BACKGROUND: Avoiding BPD during TAVR was shown to be feasible in previous studies but the risks and benefits of this technique are unknown owing to the limited number of patients included in these studies. METHODS: We performed a systematic search for studies comparing direct TAVR vs TAVR performed with BPD. Crude risk ratios (RRs) or mean differences and 95% confidence intervals (CI) for each endpoint were calculated using random effects models. RESULTS: Twenty studies including 3586 patients (1606 undergoing direct TAVR) were selected for the analysis. Mean device success with direct TAVR was 88% with <5% of bail-out techniques. There were no differences between direct and BPD-TAVR in short-term (in-hospital or 30-day) mortality (RR: 1.06; 95% CI: 0.78-1.43) or cerebrovascular events (RR: 0.92; 95% CI: 0.58-1.46). Direct TAVR associated with reduced moderate or severe paravalvular leak post-TAVR (RR: 0.59; 95% CI: 0.36-0.98) but not with a reduced risk of permanent pacemaker implantation (RR: 0.85, 95% CI: 0.71-1.02). A slight increase in postdilation was observed in direct transfemoral-TAVR recipients (RR: 1.2; 95% CI: 1.00-1.44). CONCLUSION: Direct TAVR is feasible and safe. However, given the unadjusted nature of our results, uncertainties remain regarding the independent effect of direct TAVR on outcomes post-TAVR. Randomized studies are warranted to determine the potential benefits of direct TAVR. © 2017 Wiley Periodicals, Inc.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Oportunidad Relativa , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del TratamientoRESUMEN
BACKGROUND: Transcatheter mitral valve implantation (TMVI) for severely calcified native mitral valve disease recently emerged as a treatment option in patients deemed inoperable by conventional techniques. Yet no systematic appraisal currently exists characterizing this novel treatment paradigm. METHODS: A systematic literature review summarizing the clinical, anatomical, peri- and post-procedural characteristics underscoring the technical feasibility of this procedure was performed. RESULTS: Nine publications describing 11 patients [mean age 68 ± 10 years, 82% female, 82% severe mitral stenosis (MS), 18% severe mitral regurgitation (MR)] were identified. Mean STS score, trans-mitral gradient and effective orifice area were 10.5 ± 4.6%, 12 ± 2.4 mm Hg and 0.93 ± 0.06 cm(2) respectively. All patients had severe, circumferential mitral annular calcification on imaging. Dedicated balloon-expanding transcatheter aortic valves were used in 10/11 cases, with 8/11 cases involving a true percutaneous approach with peri-procedural 3D trans-esophageal echocardiographic guidance; 3/11 cases involved an open left atrial approach. Following initial balloon inflation and valve deployment, procedural success rate was 73%, without residual paravalvular leaks (PVL). Successful immediate re-deployment of a 2nd valve was needed in 2 instances following significant PVL detection. Residual trans-valvular gradients ranged from 3 to 7 mm Hg, with no patient demonstrating >grade 2 MR. All patients survived the procedure, with 2 reported deaths on days 10- and 41 post-TMVI being non-cardiac-related. Mid-term clinical follow-up, reported in 8 patients, revealed 6 patients to be alive at 3-months with much improved functional status. CONCLUSIONS: TMVI for native severely calcified mitral valve disease appears technically feasible with acceptable initial acute and mid-term hemodynamic and clinical outcomes. The outcomes of an ongoing, dedicated global Sapien TMVI registry will shed further light on this evolving treatment paradigm.
Asunto(s)
Calcinosis/terapia , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/terapia , Estenosis de la Válvula Mitral/terapia , Válvula Mitral , Anciano , Valvuloplastia con Balón , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Recuperación de la Función , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Resultado del TratamientoRESUMEN
RATIONALE: Refractory angina constitutes a clinical problem. OBJECTIVE: The aim of this study was to assess the safety and the feasibility of transendocardial injection of CD133(+) cells to foster angiogenesis in patients with refractory angina. METHODS AND RESULTS: In this randomized, double-blinded, multicenter controlled trial, eligible patients were treated with granulocyte colony-stimulating factor, underwent an apheresis and electromechanical mapping, and were randomized to receive treatment with CD133(+) cells or no treatment. The primary end point was the safety of transendocardial injection of CD133(+) cells, as measured by the occurrence of major adverse cardiac and cerebrovascular event at 6 months. Secondary end points analyzed the efficacy. Twenty-eight patients were included (n=19 treatment; n=9 control). At 6 months, 1 patient in each group had ventricular fibrillation and 1 patient in each group died. One patient (treatment group) had a cardiac tamponade during mapping. There were no significant differences between groups with respect to efficacy parameters; however, the comparison within groups showed a significant improvement in the number of angina episodes per month (median absolute difference, -8.5 [95% confidence interval, -15.0 to -4.0]) and in angina functional class in the treatment arm but not in the control group. At 6 months, only 1 simple-photon emission computed tomography (SPECT) parameter: summed score improved significantly in the treatment group at rest and at stress (median absolute difference, -1.0 [95% confidence interval, -1.9 to -0.1]) but not in the control arm. CONCLUSIONS: Our findings support feasibility and safety of transendocardial injection of CD133(+) cells in patients with refractory angina. The promising clinical results and favorable data observed in SPECT summed score may set up the basis to test the efficacy of cell therapy in a larger randomized trial.
Asunto(s)
Angina de Pecho/terapia , Antígenos CD/metabolismo , Células Progenitoras Endoteliales/trasplante , Glicoproteínas/metabolismo , Neovascularización Fisiológica , Péptidos/metabolismo , Trasplante de Células Madre/métodos , Antígeno AC133 , Anciano , Angina de Pecho/diagnóstico por imagen , Antígenos CD/genética , Método Doble Ciego , Células Progenitoras Endoteliales/citología , Células Progenitoras Endoteliales/metabolismo , Femenino , Glicoproteínas/genética , Humanos , Masculino , Persona de Mediana Edad , Péptidos/genética , Estudios Prospectivos , Trasplante de Células Madre/efectos adversos , Tomografía Computarizada de Emisión de Fotón ÚnicoRESUMEN
AIMS: To review the safety and feasibility of a transradial (TR) approach during transcatheter structural or congenital heart disease interventions when utilized as either as a primary or secondary arterial access site. METHODS AND RESULTS: Studies and case reports published between 2002 and 2014 utilizing the TR access during transcatheter structural and congenital heart disease interventions during alcohol septal ablation (ASA), ventricular septal defect (VSD), renal denervation (RD), paravalvular leak (PVL) closure, transcatheter aortic valve implantation (TAVI, secondary access) and endovascular repair of aortic coarctation (ERAC, secondary access) were evaluated. Access-site (femoral vs. TR) vascular and bleeding complications were assessed. Femoral access complications ranged from 0.16% to 40%, with an overall incidence of 2.2% (56/2521). There were 18 reports or studies specifically evaluating the utility of TR access in the context of transcatheter structural heart disease interventions (ASA: 3; VSD: 1; RD: 3; PVL closure: 1; TAVI: 7, ERAC: 3). The use of TR access either as primary or secondary access site was feasible and allowed the completion of the procedure in all cases. The overall incidence of access-site complications following a TR approach was 0.5% (2/406 patients), with no major vascular or bleeding complications. CONCLUSIONS: A TR approach during transcatheter structural heart disease interventions appears to be a safe, effective means of delivering high procedural success accompanied by lower bleeding complications compared with the transfemoral approach.
Asunto(s)
Angioplastia/métodos , Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/cirugía , Técnicas de Ablación/métodos , Angioplastia/efectos adversos , Cateterismo Cardíaco/efectos adversos , Cardiomiopatía Hipertrófica/terapia , Etanol/uso terapéutico , Estudios de Factibilidad , Femenino , Defectos del Tabique Interatrial/cirugía , Humanos , Riñón/inervación , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Solventes/uso terapéutico , Simpatectomía/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodosRESUMEN
BACKGROUND: Several T2-mapping sequences have been recently proposed to quantify myocardial edema by providing T2 relaxation time values. However, no T2-mapping sequence has ever been validated against actual myocardial water content for edema detection. In addition, these T2-mapping sequences are either time-consuming or require specialized software for data acquisition and/or post-processing, factors impeding their routine clinical use. Our objective was to obtain in vivo validation of a sequence for fast and accurate myocardial T2-mapping (T2 gradient-spin-echo [GraSE]) that can be easily integrated in routine protocols. METHODS: The study population comprised 25 pigs. Closed-chest 40 min ischemia/reperfusion was performed in 20 pigs. Pigs were sacrificed at 120 min (n = 5), 24 h (n = 5), 4 days (n = 5) and 7 days (n = 5) after reperfusion, and heart tissue extracted for quantification of myocardial water content. For the evaluation of T2 relaxation time, cardiovascular magnetic resonance (CMR) scans, including T2 turbo-spin-echo (T2-TSE, reference standard) mapping and T2-GraSE mapping, were performed at baseline and at every follow-up until sacrifice. Five additional pigs were sacrificed after baseline CMR study and served as controls. RESULTS: Acquisition of T2-GraSE mapping was significantly (3-fold) faster than conventional T2-TSE mapping. Myocardial T2 relaxation measurements performed by T2-TSE and T2-GraSE mapping demonstrated an almost perfect correlation (R(2) = 0.99) and agreement with no systematic error between techniques. The two T2-mapping sequences showed similarly good correlations with myocardial water content: R(2) = 0.75 and R(2) = 0.73 for T2-TSE and T2-GraSE mapping, respectively. CONCLUSIONS: We present the first in vivo validation of T2-mapping to assess myocardial edema. Given its shorter acquisition time and no requirement for specific software for data acquisition or post-processing, fast T2-GraSE mapping of the myocardium offers an attractive alternative to current CMR sequences for T2 quantification.
Asunto(s)
Edema Cardíaco/patología , Imagen por Resonancia Cinemagnética/métodos , Infarto del Miocardio/patología , Daño por Reperfusión Miocárdica/patología , Miocardio/patología , Animales , Agua Corporal/metabolismo , Modelos Animales de Enfermedad , Edema Cardíaco/metabolismo , Interpretación de Imagen Asistida por Computador , Masculino , Infarto del Miocardio/metabolismo , Daño por Reperfusión Miocárdica/metabolismo , Miocardio/metabolismo , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Porcinos , Factores de TiempoRESUMEN
INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.
RESUMEN
BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Función Ventricular Izquierda , Resultado del Tratamiento , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugíaRESUMEN
BACKGROUND: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. METHODS: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm2. A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. RESULTS: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39-3.65; P=0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11-3.09]; P=0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41-1.45]; P=0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. CONCLUSIONS: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de PrótesisRESUMEN
AIMS: In heart failure (HF), implantable haemodynamic monitoring devices have been shown to optimize therapy, anticipating clinical decompensation and preventing hospitalization. Direct left-sided haemodynamic sensors offer theoretical benefits beyond pulmonary artery pressure monitoring systems. We evaluated the safety, usability, and performance of a novel left atrial pressure (LAP) monitoring system in HF patients. METHODS AND RESULTS: The VECTOR-HF study (NCT03775161) was a first-in-human, prospective, multicentre, single-arm, clinical trial enrolling 30 patients with HF. The device consisted of an interatrial positioned leadless sensor, able to transmit LAP data wirelessly. After 3 months, a right heart catheterization was performed to correlate mean pulmonary capillary wedge pressure (PCWP) with simultaneous mean LAP obtained from the device. Remote LAP measurements were then used to guide patient management. The miniaturized device was successfully implanted in all 30 patients, without acute major adverse cardiac and neurological events (MACNE). At 3 months, freedom from short-term MACNE was 97%. Agreement between sensor-calculated LAP and PCWP was consistent, with a mean difference of -0.22 ± 4.92 mmHg, the correlation coefficient and the Lin's concordance correlation coefficient values were equal to 0.79 (p < 0.0001) and 0.776 (95% confidence interval 0.582-0.886), respectively. Preliminary experience with V-LAP-based HF management was associated with significant improvements in New York Heart Association (NYHA) functional class (32% of patients reached NYHA class II at 6 months, p < 0.005; 60% of patients at 12 months, p < 0.005) and 6-min walk test distance (from 244.59 ± 119.59 m at baseline to 311.78 ± 129.88 m after 6 months, p < 0.05, and 343.95 ± 146.15 m after 12 months, p < 0.05). CONCLUSION: The V-LAP™ monitoring system proved to be generally safe and provided a good correlation with invasive PCWP. Initial evidence also suggests possible improvement in HF clinical symptoms.
Asunto(s)
Presión Atrial , Insuficiencia Cardíaca , Humanos , Cateterismo Cardíaco/métodos , Estudios Prospectivos , Presión Esfenoidal PulmonarRESUMEN
Acute ischaemic mitral regurgitation (IMR) is an increasingly rare and challenging complication following acute myocardial infarction. Despite recent technical advances in both surgical and percutaneous interventions, a poor prognosis is often associated with this challenging patient cohort. In this review, we revisit the diagnosis and typical echocardiographic features, and evaluate current surgical and percutaneous treatment options for patients with acute IMR.
RESUMEN
INTRODUCTION AND OBJECTIVES: In patients with tricuspid regurgitation (TR), edge-to-edge transcatheter tricuspid valve repair (TTVR) is the strategy with the highest penetration worldwide. A dedicated edge-to-edge TTVR system has recently become available in Europe. The present study describes the initial experience with the system in Spain. METHODS: This multicenter study collected individual data from the centers accepted for the use of the novel system within an initial limited release. Between June 2020 and March 2021, all patients undergoing an edge-to-edge TTVR using the TriClip system in Spain were included in the study. The primary endpoint was the achievement of a TR reduction of at least 1 grade at discharge. RESULTS: We included 34 patients. Most of them reported a previous history of atrial fibrillation (91%) and only 1 had a pacemaker lead. The primary endpoint (TR reduction of at least 1 grade at discharge) was met in all patients. Most of the patients required 1 (47%) or 2 clips (44%) with a clear predominance of XT (87%) over NT (13%). The location of the first clip was anteroseptal in >90% of the patients. Only 1 patient had a partial detachment, which was stabilized with additional clips in the same procedure. At discharge, TR severity was≤2 in 91% of patients. At 3 months, mortality was nil. Overall, 88% of patients were in New York Heart Association functional class≤2 and 80% had residual TR≤2. CONCLUSIONS: Edge-to-edge TTVR seemed to be effective and safe with a sustained TR reduction at 3 months. Further studies will be needed to confirm our findings.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugíaRESUMEN
BACKGROUND: Preprocedural right ventricular-to-pulmonary artery (RV-PA) coupling is a major predictor of outcome in patients with secondary mitral regurgitation (SMR) undergoing transcatheter edge-to-edge mitral valve repair (M-TEER). However, clinical significance of changes in RV-PA coupling after M-TEER is unknown. OBJECTIVES: The aim of this study was to evaluate changes in RV-PA coupling after M-TEER, their prognostic value, and predictors of improvement. METHODS: This was a retrospective observational study, including patients undergoing successful M-TEER (residual mitral regurgitation ≤2+ at discharge) for SMR at 13 European centers and with complete echocardiographic data at baseline and short-term follow-up (30-180 days). RV-PA coupling was assessed with the use of echocardiography as the ratio of tricuspid annular plane systolic excursion to pulmonary artery systolic pressure (TAPSE/PASP). All-cause death was assessed at the longest available follow-up starting from the time of the echocardiographic reassessment. RESULTS: Among 501 patients included, 331 (66%) improved their TAPSE/PASP after M-TEER (responders) at short-term follow-up (median: 89 days; IQR: 43-159 days), whereas 170 (34%) did not (nonresponders). Lack of previous cardiac surgery, low postprocedural mitral mean gradient, low baseline TAPSE, high baseline PASP, and baseline tricuspid regurgitation were independently associated with TAPSE/PASP improvement after M-TEER. Compared with nonresponders, responders had lower New York Heart Association functional class and less heart failure hospitalizations at short-term follow-up. Improvement in TAPSE/PASP was independently associated with reduced risk of mortality at long-term follow-up (584 days; IQR: 191-1,243 days) (HR: 0.65 [95% CI: 0.42-0.92]; P = 0.017). CONCLUSIONS: In patients with SMR, improvement in TAPSE/PASP after successful M-TEER is predicted by baseline clinical and echocardiographic variables and postprocedural mitral gradient, and is associated with a better outcome.
Asunto(s)
Arteria Pulmonar , Humanos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Valor Predictivo de las PruebasRESUMEN
AIM: To evaluate short-term changes in tricuspid regurgitation (TR) after transcatheter edge-to-edge mitral valve repair (M-TEER) in secondary mitral regurgitation (SMR), their predictors and impact on mortality. METHODS AND RESULTS: This is a retrospective analysis of SMR patients undergoing successful M-TEER (post-procedural mitral regurgitation ≤2+) at 13 European centres. Among 503 patients evaluated 79 (interquartile range [IQR] 40-152) days after M-TEER, 173 (35%) showed ≥1 degree of TR improvement, 97 (19%) had worsening of TR, and 233 (46%) remained unchanged. Smaller baseline left atrial diameter and residual mitral regurgitation 0/1+ were independent predictors of TR ≤2+ after M-TEER. There was a significant association between TR changes and New York Heart Association class and pulmonary artery systolic pressure decrease at echocardiographic re-assessment. At a median follow-up of 590 (IQR 209-1103) days from short-term echocardiographic re-assessment, all-cause mortality was lower in patients with improved compared to those with unchanged/worsened TR (29.6% vs. 42.3% at 3 years; log-rank p = 0.034). Baseline TR severity was not associated with mortality, whereas TR 0/1+ and 2+ at short-term follow-up was associated with lower all-cause mortality compared to TR 3/4+ (30.6% and 35.6% vs. 55.6% at 3 years; p < 0.001). A TR ≤2+ after M-TEER was independently associated with a 42% decreased risk of mortality (p = 0.011). CONCLUSION: More than one third of patients with SMR undergoing successful M-TEER experienced an improvement in TR. Pre-procedural TR was not associated with outcome, but a TR ≤2+ at short-term follow-up was independently associated with long-term mortality. Optimal M-TEER result and a small left atrium were associated with a higher likelihood of TR ≤2+ after M-TEER.