Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Hand Surg Am ; 42(8): 630-638, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28666676

RESUMEN

PURPOSE: The ARPE joint arthroplasty was introduced in 1991 for the treatment of symptomatic trapeziometacarpal (TMC) osteoarthritis. The primary outcome of this prospective study is to report the medium- to long-term joint survival of this prosthesis. Our secondary outcomes are the clinical and functional results. METHODS: A prospective, consecutive case series study was done at our hand unit. Patients included in the study had at least 5 years follow-up after a total joint arthroplasty for osteoarthritis of the TMC joint using the ARPE implant. The Kaplan-Meier method was used to estimate implant survival over time. Clinical and radiological assessment was recorded prospectively: before surgery and at 1 year and 5 years or more after surgery. We compared the means of the Kapandji index (assessing the thumb range of motion and opposition), the grip strength, and the pinch strength before surgery and at the latest follow-up. RESULTS: We included all 166 prostheses in the survival analysis with a mean follow-up of 80 months. Five prostheses (3%) required revision surgery and 1 implant (0.6%) failed. Therefore, Kaplan-Meier survival probability was 96% with a mean follow-up of 80 months (95% confidence interval, 91-98). A total of 120 arthroplasties from 115 patients were included in the clinical analysis. At 5 years' follow-up, the median Disabilities of the Arm, Shoulder, and Hand (DASH) score was 4.6 (range, 0-86.6). There was a significant improvement of the mean opposition and grip strength of the affected thumb at final follow-up in comparison with the preoperative values. There was also a significant improvement in the mean pinch strength at 1 year and 5 years after surgery compared with preoperative measurements. CONCLUSIONS: In our series, the ARPE prosthesis of the thumb TMC joint has proven to be a reliable and effective implant. Mean motion and strength increased whereas pain decreased after surgery and these results remained constant within the follow-up period. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Asunto(s)
Articulaciones Carpometacarpianas , Prótesis Articulares , Osteoartritis/fisiopatología , Osteoartritis/cirugía , Femenino , Estudios de Seguimiento , Fuerza de la Mano , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Rango del Movimiento Articular , Recuperación de la Función , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
2.
J Hand Surg Glob Online ; 2(1): 61-65, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35415472

RESUMEN

An unstable distal ulnar stump after Darrach resection, alongside pathology of the radiocarpal joint, is difficult to manage without fusion of at least one joint. Currently, no standard 2-in-1 arthroplasty is available. We report the case of a 72-year-old woman with loosening of the radial stem of a Universal 2 total wrist prosthesis combined with radioulnar impingement after a Darrach procedure. Because of poor radial bone stock, the standard fixation technique of a semi-constrained distal radioulnar joint prosthesis (Aptis) was not possible. We present a technique to fix the semi-constrained distal radioulnar joint prosthesis as well as a total wrist prosthesis by a custom 3-dimensional printed flange prosthesis to the ulnar border of the radius. Three years after surgery, the patient remained pain-free, with 60° flexion, 75° extension, 80° pronation, and 80° supination.

3.
Prosthet Orthot Int ; 41(1): 78-84, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26447140

RESUMEN

BACKGROUND: Flexor tendon repair in the hand remains challenging in avoiding tendon rupture and adhesion formation. Post-operative mobilization has been shown to be critical in regaining functional range of motion. OBJECTIVES: The objective of this study is 2-fold: to assess the influence of wrist position on maximum grip force generated in a post-operative orthosis and to determine the correlation between this maximum grip force and an individual's grip strength. STUDY DESIGN: Clinical measurement Methods: A total of 30 uninjured wrists of right-handed men were given a post-operative orthosis with an incorporated Caroli-hinge. The maximum grip force was measured according to a different wrist position ranging from -30° extension until 80° of flexion using a 10° interval. These measurements were plotted out on a graph for regression analysis. A correlation was determined between measurements in a neutral wrist position and maximum grip strength generated without an orthosis. To assess the coherence of the measurements, a mean intraclass correlation coefficient was used. RESULTS: The maximum grip force values were statistically significantly different in every wrist position and decreased progressively with an increasing flexion angle ( p < 0.05). This relationship is expressed in a logistic regression curve f( x) = -4.98 + 16.92/(1 + (x/8.59))2.24. A wrist position of 4.4° of flexion was derived from this function to cause a maximum grip force reduction of 33%. Further analysis showed a force decrease of 50% at 23.2° and 66% at 51.8° of wrist flexion. The grip strength measured without an orthosis showed a positive correlation with previous measurements (Spearman's correlation coefficient = 0.74 for the right hand and 0.72 for the left hand ( p < 0.001)). CONCLUSIONS: The obtained logistic function allowed to derive the wrist position needed in a post-operative orthosis to obtain a desired amount of maximum grip force reduction. Clinical relevance Measuring a high grip force in a clinical setting of flexor tendon repair on the contralateral non-affected hand could indicate the use of an increased flexion angle in a post-operative orthosis. This reduces the load transferred on the tendon repair when involuntary contractions take place, for example, during sleeping when positioned in a post-operative orthosis.


Asunto(s)
Fuerza de la Mano/fisiología , Aparatos Ortopédicos , Articulación de la Muñeca/fisiología , Adulto , Diseño de Equipo , Humanos , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios , Rango del Movimiento Articular/fisiología , Adulto Joven
4.
Strategies Trauma Limb Reconstr ; 10(1): 1-4, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25697273

RESUMEN

Exposure of the distal humerus in case of an articular fracture is often performed through a Chevron osteotomy of the olecranon. Several options have been described for re-fixation of the Chevron osteotomy. Pull-out of the hard-wear is often seen as complication. In this study, an evaluation of the re-fixation of the Chevron osteotomy through a cancellous screw and suture tension band was performed. The data of 19 patients in whom a Chevron osteotomy was re-fixated with a cancellous screw in combination with a suture tension band were used. Evaluation was performed by assessment of the post-operative X-rays and documentation of complications. In all 19 cases, evaluation of the post-operative X-rays showed complete consolidation without dislocation or other complications. Re-fixation of a Chevron osteotomy of the olecranon with a large cancellous screw with a suture tension band provides adequate stability to result in proper healing of the osteotomy in primary cases when early post-operative mobilisation is allowed. Complications as pull-out of the hard-wear were not reported.

5.
Hand (N Y) ; 10(1): 147-51, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25762890

RESUMEN

Although airbags are designed to save lives and protect victims from serious injuries, airbag deployment can cause unwanted lesions. In this case report, two cases are presented of young women who sustained an important fracture dislocation of the first carpometacarpal joint (CMC I joint) caused by airbag deployment during a car collision.

6.
J Wrist Surg ; 2(4): 306-14, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24436834

RESUMEN

Corrective osteotomies of the distal radius for symptomatic malunion are time-tested procedures that rely on accurate corrections. Patients with combined intra- and extra-articular malunions present a challenging deformity. Virtual planning and patient-specific instruments (PSIs) to transfer the planning into the operating room have been used both to simplify the surgery and to make it more accurate. This report focuses on the clinically achieved accuracy in four patients treated between 2008 and 2012 with virtual planning and PSIs for a combined intra- and extraarticular malunion of the distal radius. The accuracy of the correction is quantified by comparing the virtual three-dimensional (3D) planning model with the postoperative 3D bone model. For the extraarticular malunion the 3D volar tilt, 3D radial inclination and 3D ulnar variance are measured. The volar tilt is undercorrected in all cases with an average of -6 ± 6°. The average difference between the postoperative and planned 3D radial inclination was -1 ± 5°. The average difference between the postoperative and planned 3D ulnar variances is 0 ± 1 mm. For the evaluation of the intraarticular malunion, both the arc method of measurement and distance map measurement are used. The average postoperative maximum gap is 2.1 ± 0.9 mm. The average maximum postoperative step-off is 1.3 ± 0.4 mm. The average distance between the postoperative and planned articular surfaces is 1.1 ± 0.6 mm as determined in the distance map measurement. There is a tendency to achieve higher accuracy as experience builds up, both on the surgeon's side and on the design engineering side. We believe this technology holds the potential to achieve consistent accuracy of very complex corrections.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA