RESUMEN
AIMS: Differentiating near-field (NF) and far-field (FF) electrograms (EGMs) is crucial in identifying critical arrhythmogenic substrate during ventricular tachycardia (VT) ablation. A novel algorithm annotates NF-fractionated signals enabling EGM peak frequency (PF) determination using wavelet transformation. This study evaluated the algorithms' effectiveness in identifying critical components of the VT circuit during substrate mapping. METHODS AND RESULTS: A multicentre, international cohort undergoing VT ablation was investigated. VT activation maps were used to demarcate the isthmus zone (IZ). Offline analysis was performed to evaluate the diagnostic performance of low-voltage area (LVA) PF substrate mapping. A total of 30 patients encompassing 198 935 EGMs were included. The IZ PF was significantly higher in sinus rhythm (SR) compared to right ventricular paced (RVp) substrate maps (234â Hz (195-294) vs. 197â Hz (166-220); P = 0.010). Compared to LVA PF, the IZ PF was significantly higher in both SR and RVp substrate maps (area under curve, AUC: 0.74 and 0.70, respectively). The LVA PF threshold of ≥200â Hz was optimal in SR maps (sensitivity 69%; specificity 64%) and RVp maps (sensitivity 60%; specificity 64%) in identifying the VT isthmus. In amiodarone-treated patients (n = 20), the SR substrate map IZ PF was significantly lower (222â Hz (186-257) vs. 303â Hz (244-375), P = 0.009) compared to amiodarone-naïve patients (n = 10). The ≥200â Hz LVA PF threshold resulted in an 80% freedom from VT with a trend towards reduced ablation lesions and radiofrequency times. CONCLUSION: LVA PF substrate mapping identifies critical components of the VT circuit with an optimal threshold of ≥200â Hz. Isthmus PF is influenced by chronic amiodarone therapy with lower values observed during RV pacing.
Asunto(s)
Algoritmos , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Masculino , Femenino , Persona de Mediana Edad , Técnicas Electrofisiológicas Cardíacas/métodos , Ablación por Catéter/métodos , Anciano , Frecuencia Cardíaca , Potenciales de Acción , Análisis de Ondículas , Valor Predictivo de las Pruebas , Estimulación Cardíaca ArtificialRESUMEN
AIMS: Since the introduction of direct oral anticoagulant (DOAC) for atrial fibrillation (AF) therapy, inappropriate and/or underdosing of these drugs has been a major clinical challenge. We evaluated the characteristics of patients with AF treated with inappropriate and low-dose DOACs. METHODS AND RESULTS: Patients with AF treated with inappropriate and low-dose DOACs from October 2021 to December 2021 were evaluated from the French National Prospective Registry (PAFF). We evaluated 1890 patients with AF receiving DOACs (apixaban 55%, dabigatran 7%, and rivaroxaban 38%). Inappropriate dosing was noted in 18% of the population. Patients with appropriate dosing had less comorbidities: younger age (75 ± 10 vs. 82 ± 8 years old, P < 0.0001), reduced chronic renal failure (26 vs. 61%, P < 0.0001), and lower CHA2DS2VASc and HASBLED scores (3 ± 2 vs. 4 ± 3, P < 0.0001; 2 ±1 vs. 2 ± 2, P < 0.0001), respectively. In multivariate analysis, older age (P < 0.0001) and a higher CHA2DS2VASc score (P = 0.0056) were independently associated with inappropriate DOAC dosing. Among 472 patients (27%) treated with low-dose rivaroxaban or apixaban, 46% were inappropriately underdosed. Patients inappropriately underdosed were younger (82.3 ± 8.4 vs. 85.9 ± 5.9 years, P < 0.0001) with less chronic renal disease (47 vs. 98%, P < 0.0001). However, these patients had higher rates of prior haemorrhagic events (18 vs. 10%, P = 0.01), clopidogrel use (11 vs. 3%, P = 0.0002), and apixaban prescription (74 vs. 50%, P < 0.0001). CONCLUSION: Within this large registry, DOACs were associated with inappropriate dosing in 18% of cases. Independent predictors of inappropriate dosing were high CHA2DS2VASc scores and older age. Moreover, 46% of patients treated with low-dose DOACs were inappropriately underdosed and more frequently in patients treated with apixaban.
Asunto(s)
Fibrilación Atrial , Fallo Renal Crónico , Accidente Cerebrovascular , Humanos , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/complicaciones , Rivaroxabán , Anticoagulantes , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Estudios Retrospectivos , Dabigatrán , Sistema de Registros , Fallo Renal Crónico/complicaciones , Administración OralRESUMEN
BACKGROUND: Percutaneous left atrial appendage (LAA) closure is an alternative to oral anticoagulation (OAC) for atrial fibrillation (AF) patients with high thromboembolism risk, particularly with contraindications to OAC. The LAA itself could possess proarrhythmogenic properties. As patients undergoing LAA closure could be candidates for cardioversion or ablation, we aimed to evaluate AF disease progression following LAA closure and the outcome of patients undergoing a rhythm control strategy after the procedure. METHODS: The prospective multicenter French Nationwide Observational LAA Closure Registry (FLAAC) comprises 33 French interventional cardiology departments. Patients were included if they fulfilled the following criteria: history of non-valvular AF, successful LAA closure and long-term ECG follow-up. RESULTS: A total of 331 patients with successful LAA closure were enrolled in the study. Patients mean age was 75.4 ± 0.5 years. The study population was characterized by a high thromboembolic risk (CHA2DS2-VASc score: 4.5 ± 0.1) and frequent comorbidities. The median follow-up was 11.9 months. One hundred and nineteen (36.0%) patients were in sinus rhythm (SR) at baseline. Among SR patients, documented AF was observed in 16 (13.4%) patients whereas 15 (7.1%) patients in AF at baseline restored SR, at the end of follow up. Finally, only 13 patients (4%) underwent procedures to restore SR without complications during the follow-up. CONCLUSIONS: The vast majority of patients undergoing LAA closure have the same AF status at baseline and one year after the index procedure. During the follow-up, a very small proportion (4%) of our population underwent procedures to restore SR without complications whatever the post-procedural antithrombotic strategy was.
Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Función del Atrio Izquierdo , Frecuencia Cardíaca , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Ablación por Catéter , Cardioversión Eléctrica , Electrocardiografía , Femenino , Francia , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Sistema de Registros , Retratamiento , Factores de Tiempo , Resultado del TratamientoRESUMEN
Implantable cardioverter-defibrillators (ICDs) have revolutionized the primary and secondary prevention of patients with ventricular arrhythmias. However, the adverse effects of appropriate or inappropriate shocks may require the adjunctive use of anti-arrhythmic drugs (AADs). Beta blockers are the cornerstone of pharmacological primary and secondary prevention of ventricular arrhythmias. In addition to their established efficacy at reducing the incidence of ventricular arrhythmias, beta-blockers are safe with few side effects. Amiodarone is superior to beta blockers and sotalol for the prevention of ventricular arrhythmia recurrence. However, long-term amiodarone use is associated with significant side effects that limit its utility. Sotalol and mexiletine are the main alternatives to amiodarone with a better side effect profile though they are less efficacious at preventing ventricular arrhythmia recurrence. Dofetilide, azimilide and ranolazine are emerging as therapeutic options for secondary prevention; more studies are needed to assess efficacy and safety in comparison to currently used agents. Beta blockers and amiodarone are the mainstay of therapy in patients experiencing electrical storm; their use reduces the frequency of ventricular arrhythmias and ICD intervention as well as affording time until catheter ablation can be considered.
Asunto(s)
Antiarrítmicos/uso terapéutico , Desfibriladores Implantables , Fibrilación Ventricular/terapia , Antiarrítmicos/efectos adversos , Cardiomiopatías/terapia , Ablación por Catéter , Humanos , Isquemia Miocárdica/terapiaRESUMEN
INTRODUCTION: Reversible premature ventricular complexes-induced cardiomyopathy (PVC-CMP) is a well-described, multi-factorial entity. Single predictors, such as PVC burden or QRS duration, may not apply equally to all patients in contemporary unselected populations including patients with structural heart disease (SHD) or with particular origin such as epicardial (EPI) PVC. We sought to evaluate clinical criteria associated with PVC-CMP notably focusing on the EPI origin impact and ECG recognition and the value of a new composite predictor of PVC-CMP, the PVC-CMP-Index. METHODS AND RESULTS: We studied 107 consecutive patients (69 men; mean age = 56 ± 16 years) with frequent PVC (23.1 ± 11.5%) referred for PVC ablation. Thirty-six patients (33.6%) had an underlying SHD and 25 patients (23.4%) an EPI PVC origin. After a mean follow-up of 22.7 ± 15.3 months, 72.9% achieved a long-term successful ablation and 54.2% had PVC-CMP. PVC-CMP prevalence was significantly higher in patients with an EPI compared to endocardial PVC focus (84.0% vs. 45.1%, respectively, P < 0.001). EPI PVC origin (OR = 68.7 IC95% [3.5-1363], P = 0.005), as well as SHD (OR = 12.3 IC95% [1.6-92.6], P = 0.015), was independent predictor of PVC-CMP. While PVC burden (AUC = 0.78) or PVC-QRS width (AUC = 0.68) independently predicted PVC-CMP, the PVC-CMP-Index (values ≥39) defined as: PVC burden (0-1) × PVC-QRS width (milliseconds) × a constant C (1.28 for SHD or 2 for ECG suggesting EPI origin based on our ECG 3-step algorithm), highly correlated with PVC-CMP (AUC = 0.91, sensitivity = 93%, specificity = 80%). CONCLUSION: We developed a new index, which incorporates PVC burden, QRS width, and presence of SHD or suspected EPI origin that best predicted PVC-CMP.
Asunto(s)
Cardiomiopatías/complicaciones , Electrocardiografía , Pericardio/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico , Potenciales de Acción , Adulto , Anciano , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Ablación por Catéter , Distribución de Chi-Cuadrado , Femenino , Frecuencia Cardíaca , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Complejos Prematuros Ventriculares/etiología , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugíaRESUMEN
BACKGROUND: The DiamondTemp ablation (DTA) system is a novel temperature-controlled irrigated radiofrequency (RF) ablation system that accurately measures tip-tissue temperatures for real-time power modulation. Lesion morphologies from longer RF durations with the DTA system have not been previously described. We sought to evaluate lesion characteristics of the DTA system when varying the application durations. METHODS: A bench model using porcine myocardium was used to deliver discrete lesions in a simulated clinical environment. The DTA system was power-limited at 50 W with temperature set-points of 50 °C and 60 °C (denoted Group_50 and Group_60). Application durations were randomized with a range of 5-120 s. RESULTS: In total, 280 applications were performed. Steam pops were observed in five applications: two applications at 90 s and three applications at 120 s. Lesion size (depth and maximum width) increased significantly with longer applications, until 60 s for both Group_50 and Group_60 (depth: 4.5 ± 1.2 mm and 5.6 ± 1.3 mm; maximum width: 9.3 ± 2.7mm and 11.2 ± 1.7mm, respectively). As lesions transition from resistive to conductive heating (longer than 10 s), the maximum width progressed in a sub-surface propagation. Using a "Time after Temperature 60 °C" (TaT60) analysis, depths of 2-3 mm occur in 0-5 s and depths plateau at 4.6 ± 0.8 mm between 20 and 30 s. CONCLUSIONS: The DTA system rapidly creates wide lesions with lesion depth increasing over time with application durations up to 60 s. Using a TaT60 approach is a promising ablation guidance that would benefit from further investigation.
Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Animales , Porcinos , Temperatura , Irrigación Terapéutica , Catéteres , Diseño de EquipoRESUMEN
BACKGROUND: Atrial arrhythmias (AA) commonly affect patients with cardiac amyloidosis (CA) and are a contributing risk factor for the development of heart failure (HF). This study sought to investigate the long-term efficacy and impact of catheter ablation on HF progression in patients with CA and AA. METHODS: Thirty-one patients with CA and AA undergoing catheter ablation were retrospectively included (transthyretin-ATTR CA 61% and light chain-AL CA 39%). AA subtypes included atrial fibrillation (AFib) in 22 (paroxysmal in 10 and persistent in 12), atrial flutter (AFl) in 17 and atrial tachycardia (AT) in 11 patients. Long-term AA recurrence rates were evaluated along with the impact of sinus rhythm (SR) maintenance on HF and mortality. RESULTS: AA recurrence was observed in 14 patients (45%) at a median of 3.5 months (AFib n = 8, AT n = 6, AFl = 0). Post-cardioversion, medical therapy or catheter ablation, 10 patients (32%) remained in permanent AA. Over a median follow-up of 19 months, all-cause mortality was 39% (n = 12): 3 with end-stage HF, 5 due to late complications of CA, 1 sudden cardiac death, 1 stroke, 1 COVID 19 (and one unknown). With maintenance of SR following catheter ablation, significant reductions in serum creatinine and natriuretic peptide levels were observed with improvements in NYHA class. Two patients required hospitalization for HF in the SR maintenance cohort compared to 5 patients in the AA recurrence cohort (p = 0.1). All 3 patients with deaths secondary to HF had AA recurrence compared to 11 out of the 28 patients whom were long-term survivors or deaths not related to HF (p = 0.04). All-cause mortality was not associated with AA recurrence. CONCLUSION: This study demonstrates moderate long-term efficacy of SR maintenance with catheter ablation for AA in patients with CA. Improvements in clinical and biological status with positive trends in HF mortality are observed if SR can be maintained.
Asunto(s)
Amiloidosis , Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Taquicardia Supraventricular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Recurrencia Local de Neoplasia/cirugía , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Amiloidosis/complicaciones , Amiloidosis/cirugía , Ablación por Catéter/efectos adversosRESUMEN
BACKGROUND: The DiamondTemp ablation (DTA) catheter system delivers high power, open-irrigated, temperature-controlled radiofrequency (RF) ablation. This novel ablation system has not been previously used for ventricular tachycardia (VT) ablation. OBJECTIVE: Feasibility of using the DTA catheter system for VT ablation in ischaemic cardiomyopathy (ICM) patients. METHOD: Ten ICM patients with optimal anti-arrhythmic drug therapy and implantable cardiac defibrillators (ICD) were recruited. VT inducibility testing was performed at the end of the procedure. ICD data for device detected VT episodes and device treated VT episodes were collected for 6-months pre- and post-ablation. RESULTS: Substrate analysis demonstrated reductions in the borderzone area of 4.4 cm2 (p = 0.026) and late potential area of 3.5 cm2 (p = 0.0449) post-ablation, with reductions in the mean bipolar and unipolar voltages of the ablation target areas (0.14 mV (p = 0.0007); 0.59 mV (p = 0.0072) respectively). Complete procedural success was achieved in 9 procedures. Post-ablation VT inducibility testing was not performed in 1 procedure due to a steam pop complication resulting in pericardial tamponade requiring drainage. Mean follow-up of 214 ± 33 days revealed an 88% reduction in total VT episodes (n = 266 median 16 [IQR 3-57] to n = 33 median 0; p = 0.0164) and 77% reduction in ICD therapies (n = 128 median 5 [IQR 2-15] to n = 30 median 0; p = 0.0181). CONCLUSION: The DTA system resulted in adequate lesion characteristics with effective substrate modification, acute procedural success and improved outcomes at intermediate-term follow-up. Randomised controlled trials are required to compare the performance of the DTA system against conventional ablation catheters.
Asunto(s)
Cardiomiopatías , Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Resultado del Tratamiento , Temperatura , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Ablación por Catéter/métodosRESUMEN
Migration of megakaryocytes (MKs) from the proliferative osteoblastic niche to the capillary-rich vascular niche is essential for proplatelet formation and platelet release. In this study, we explore the role of surface glycoprotein receptors and signaling proteins in regulating MK migration and platelet recovery after immune-induced thrombocytopenia. We show that spreading and migration of mouse primary bone marrow-derived MKs on a fibronectin matrix are abolished by the Src family kinases inhibitor PP1, the Syk kinase inhibitor R406 and the integrin alphaIIbbeta3 antagonist lotrafiban. We also demonstrate that these responses are inhibited in primary phospholipase C gamma2 (PLCgamma2)-deficient MKs. Conversely, MK spreading and migration were unaltered in the absence of the collagen receptor, the glycoprotein VI-FcRgamma-chain complex. We previously reported a correlation between a defect in MK migration and platelet recovery in the absence of platelet endothelial cell adhesion molecule-1 and the tyrosine phosphatase CD148. This correlation also holds for mice deficient in PLCgamma2. This study identifies a model in which integrin signaling via Src family kinases and Syk kinase to PLCgamma2 is required for MK spreading, migration, and platelet formation.
Asunto(s)
Plaquetas/citología , Péptidos y Proteínas de Señalización Intracelular/fisiología , Megacariocitos/citología , Fosfolipasa C gamma/fisiología , Proteínas Tirosina Quinasas/fisiología , Proteínas Proto-Oncogénicas pp60(c-src)/fisiología , Trombopoyesis/fisiología , Animales , Benzodiazepinas/farmacología , Movimiento Celular/efectos de los fármacos , Movimiento Celular/fisiología , Forma de la Célula , Células Cultivadas/citología , Células Cultivadas/enzimología , Péptidos y Proteínas de Señalización Intracelular/antagonistas & inhibidores , Megacariocitos/enzimología , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Oxazinas/farmacología , Fosfolipasa C gamma/antagonistas & inhibidores , Fosfolipasa C gamma/deficiencia , Fosforilación/efectos de los fármacos , Piperidinas/farmacología , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/fisiología , Inhibidores de Proteínas Quinasas/farmacología , Procesamiento Proteico-Postraduccional/efectos de los fármacos , Proteínas Tirosina Quinasas/antagonistas & inhibidores , Proteínas Proto-Oncogénicas pp60(c-src)/antagonistas & inhibidores , Púrpura Trombocitopénica Idiopática/inducido químicamente , Púrpura Trombocitopénica Idiopática/patología , Pirazoles/farmacología , Piridinas/farmacología , Pirimidinas/farmacología , Transducción de Señal/efectos de los fármacos , Transducción de Señal/fisiología , Quinasa SykRESUMEN
AIMS: This study sought to describe and evaluate the impact of a routine in-hospital cardiac resynchronization therapy (CRT) programme, including comprehensive heart failure (HF) evaluation and systematic echo-guided CRT optimization. METHODS AND RESULTS: CRT implanted patients were referred for optimization programme at 3 to 12 months from implantation. The program included clinical and biological status, standardized screening for potential cause of CRT non-response and systematic echo-guided atrioventricular and interventricular delays (AVd and VVd) optimization. Initial CRT-response and improvement at 6 months post-optimization were assessed with a clinical composite score (CCS). Major HF events were tracked during 1 year after optimization. A total of 227 patients were referred for CRT optimization and enrolled (71 ± 11 years old, 77% male, LVEF 30.6 ± 7.9%), of whom 111 (48.9%) were classified as initial non-responders. Left ventricular lead dislodgement was noted in 4 patients (1.8%), and loss or ≤90% biventricular capture in 22 (9.7%), mostly due to arrhythmias. Of the 196 patients (86%) who could undergo echo-guided CRT optimization, 71 (36.2%) required VVd modification and 50/144 (34.7%) AVd modification. At 6 months post-optimization, 34.3% of the initial non-responders were improved according to the CCS, but neither AVd nor VVd echo-guided modification was significantly associated with CCS-improvement. After one-year follow-up, initial non-responders maintained a higher rate of major HF events than initial responders, with no significant difference between AVd/VVd modified or not. CONCLUSIONS: Our study supports the necessity of a close, comprehensive and multidisciplinary follow-up of CRT patients, without arguing for routine use of echo-guided CRT optimization.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Terapia de Resincronización Cardíaca/métodos , Ecocardiografía , Resultado del Tratamiento , Dispositivos de Terapia de Resincronización CardíacaRESUMEN
AIMS: Atrial fibrillation (AF)/atrial flutter is common during cardiac amyloidosis (CA). Electrical cardioversion (EC) is a strategy to restore sinus rhythm (SR). However, left atrial thrombus (LAT) represents a contraindication for EC. CA patients with AF/atrial flutter have a high prevalence of LAT. We aimed to evaluate EC characteristics, LAT prevalence and risk factors, and AF/atrial flutter outcome in CA patients undergoing EC, predominantly treated with direct oral anticoagulants (DOACs). METHODS AND RESULTS: All patients with CA and AF/atrial flutter referred for the first time to our national referral centre of amyloidosis for EC from June 2017 to February 2021 were included in this study. In total, 66 patients (median age 74.5 [70;80.75] years, 67% male) were included with anticoagulation consisted of DOAC in 74% of cases. All patients underwent cardiac imaging before EC to rule out LAT. EC was cancelled due to LAT in 14% of cases. Complete thrombus resolution was observed in only 17% of cases. The two independent parameters associated with LAT were creatinine [hazard ratio (HR) = 1.01; confidence interval (CI) = 1.00-1.03, P = 0.036] and the use of antiplatelet agents (HR = 13.47; CI = 1.85-98.02). EC acute success rate was 88%, and we observed no complication after EC. With 64% of patients under amiodarone, AF/atrial flutter recurrence rate following EC was 51% after a mean follow-up of 30 ± 27 months. CONCLUSIONS: Left atrial thrombus was observed in 14% of CA patients listed for EC and mainly treated with DOAC. The acute EC success rate was high with no complication. The long-term EC success rate was acceptable (49%).
Asunto(s)
Amiloidosis , Fibrilación Atrial , Aleteo Atrial , Cardiopatías , Trombosis , Humanos , Masculino , Anciano , Femenino , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/métodos , Aleteo Atrial/complicaciones , Aleteo Atrial/terapia , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Trombosis/etiología , Amiloidosis/complicaciones , Amiloidosis/diagnóstico , Amiloidosis/terapiaRESUMEN
Platelets play a fundamental role in hemostasis and thrombosis. They are also involved in pathologic conditions resulting from blocked blood vessels, including myocardial infarction and ischemic stroke. Platelet adhesion, activation, and aggregation at sites of vascular injury are regulated by a diverse repertoire of tyrosine kinase-linked and G protein-coupled receptors. Src family kinases (SFKs) play a central role in initiating and propagating signaling from several platelet surface receptors; however, the underlying mechanism of how SFK activity is regulated in platelets remains unclear. CD148 is the only receptor-like protein tyrosine phosphatase identified in platelets to date. In the present study, we show that mutant mice lacking CD148 exhibited a bleeding tendency and defective arterial thrombosis. Basal SFK activity was found to be markedly reduced in CD148-deficient platelets, resulting in a global hyporesponsiveness to agonists that signal through SFKs, including collagen and fibrinogen. G protein-coupled receptor responses to thrombin and other agonists were also marginally reduced. These results highlight CD148 as a global regulator of platelet activation and a novel antithrombotic drug target.
Asunto(s)
Activación Plaquetaria/genética , Trombosis/genética , Animales , Antígenos de Superficie/metabolismo , Plaquetas/metabolismo , Adhesión Celular/efectos de los fármacos , Células Cultivadas , Fibrinógeno/farmacología , Humanos , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Agregación Plaquetaria/efectos de los fármacos , Glicoproteínas de Membrana Plaquetaria/metabolismo , Glicoproteínas de Membrana Plaquetaria/fisiología , Proteínas Tirosina Fosfatasas/genética , Proteínas Tirosina Fosfatasas/fisiología , Proteínas Tirosina Fosfatasas Clase 3 Similares a Receptores/genética , Proteínas Tirosina Fosfatasas Clase 3 Similares a Receptores/metabolismo , Proteínas Tirosina Fosfatasas Clase 3 Similares a Receptores/fisiología , Receptores de IgG/genética , Transducción de Señal/inmunologíaRESUMEN
Radiofrequency catheter ablation has become an established treatment for ventricular tachycardia. The exponential increase in procedures has provided further insights into mechanisms causing arrhythmias and identification of ablation targets with the development of new mapping strategies. Since the definition of criteria to identify myocardial dense scar, borderzone and normal myocardium, and the description of isolated late potentials, local abnormal ventricular activity and decrementing evoked potential mapping, substrate-guided ablation has progressively become the method of choice to guide procedures. Accordingly, a wide range of ablation strategies have been developed from scar homogenization to scar dechanneling or core isolation using increasingly complex and precise tools such as multipolar or omnipolar mapping catheters. Despite these advances long-term success rates for VT ablation have remained static and lower in nonischemic than ischemic heart disease because of the more patchy distribution of myocardial scar. Ablation aims to deliver an irreversible loss of cellular excitability by myocardial heating to a temperatures exceeding 50°C. Many indicators of ablation efficacy have been developed such as contact force, impedance drop, force-time integral and ablation index, mostly validated in atrial fibrillation ablation. In ventricular procedures there is limited data and ablation lesion parameters have been scarcely investigated. Since VT arrhythmia recurrence can be related to inadequate RF lesion formation, it seems reasonable to establish robust markers of ablation efficacy.
RESUMEN
Implantable cardiac defibrillators (ICDs) can prevent sudden cardiac death, but the risk of recurrent ventricular arrhythmia (VA) and ICD shocks persist. Strategies to minimise such risks include medication optimisation, device programming and ventricular tachycardia (VT) ablation. Whether the choice of these interventions at follow-up are influenced by factors such as the type of arrhythmia or ICD therapy remains unclear. To investigate this, we evaluated ICD follow-up strategies in a real-world population with primary and secondary prevention ICDs. REFINE-VT (Real-world Evaluation of Follow-up strategies after Implantable cardiac-defibrillator therapies in patients with Ventricular Tachycardia) is an observational study of 514 ICD recipients recruited between 2018 and 2019. We found that 77 patients (15%) suffered significant VA and/or ICD therapies, of whom 26% experienced a second event; 31% received no intervention. We observed an inconsistent approach to the choice of strategies across different types of arrhythmias and ICD therapies. Odds of intervening were significantly higher if ICD shock was detected compared with anti-tachycardia pacing (odds ratio [OR] 8.4, 95% confidence interval [CI] 1.7 to 39.6, p=0.007). Even in patients with two events, the rate of escalation of antiarrhythmics or referral for VT ablation were as low as patients with single events. This is the first contemporary study evaluating how strategies that reduce the risk of recurrent ICD events are executed in a real-world population. Significant inconsistencies in the choice of interventions exist, supporting the need for a multi-disciplinary approach to provide evidence-based care to this population.
RESUMEN
BACKGROUND: Substrate mapping has highlighted the importance of targeting diastolic conduction channels and late potentials during ventricular tachycardia (VT) ablation. State-of-the-art multipolar mapping catheters have enhanced mapping capabilities. The purpose of this study was to investigate whether long-term outcomes were improved with the use of a HD Grid mapping catheter combining complementary mapping strategies in patients with structural heart disease VT. METHODS: Consecutive patients underwent VT ablation assigned to either HD Grid, Pentaray, Duodeca, or point-by-point (PbyP) RF mapping catheters. Clinical endpoints included recurrent anti-tachycardia pacing (ATP), appropriate shock, asymptomatic non-sustained VT, or all-cause death. RESULTS: Seventy-three procedures were performed (33 HD Grid, 22 Pentaray, 12 Duodeca, and 6 PbyP) with no significant difference in baseline characteristics. Substrate mapping was performed in 97% of cases. Activation maps were generated in 82% of HD Grid cases (Pentaray 64%; Duodeca 92%; PbyP 33% (p = 0.025)) with similar trends in entrainment and pace mapping. Elimination of all VTs occurred in 79% of HD Grid cases (Pentaray 55%; Duodeca 83%; PbyP 33% (p = 0.04)). With a mean follow-up of 372 ± 234 days, freedom from recurrent ATP and shock was 97% and 100% respectively in the HD Grid group (Pentaray 64%, 82%; Duodeca 58%, 83%; PbyP 33%, 33% (log rank p = 0.0042, p = 0.0002)). CONCLUSIONS: This study highlights a step-wise improvement in survival free from ICD therapies as the density of mapping capability increases. By using a high-density mapping catheter and combining complementary mapping strategies in a strict procedural workflow, long-term clinical outcomes are improved.
Asunto(s)
Ablación por Catéter , Cardiopatías , Taquicardia Ventricular , Catéteres , Electrodos , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Resultado del TratamientoRESUMEN
BACKGROUND: Defining diastolic slow-conduction channels within the borderzone (BZ) of scar-dependent re-entrant ventricular tachycardia (VT) is key for effective mapping and ablation strategies. Understanding wavefront propagation is driving advances in high-density (HD) mapping. The newly developed Advisor™ HD Grid Mapping Catheter (HD GRID) has equidistant spacing of 16, 1 mm electrodes in a 4 × 4 3 mm interspaced arrangement allowing bipolar recordings along and uniquely across the splines (orthogonal vector) to facilitate substrate mapping in a WAVE configuration (WAVE). The purpose of this study was to determine the relative importance of the WAVE configuration compared to the STANDARD linear-only bipolar configuration (STANDARD) in defining VT substrate. METHODS: Thirteen patients underwent VT ablation at our institution. In all cases, a substrate map was constructed with the HD GRID in the WAVE configuration (conWAVE) to guide ablation strategy. At the end of the procedure, the voltage map was remapped in the STANDARD configuration (conSTANDARD) using the turbo-map function. Detailed post-hoc analysis of the WAVE and STANDARD maps was performed blinded to the configuration. Quantification of total scar area, BZ and dense scar area with assessment of conduction channels (CC) was performed. RESULTS: The substrate maps conSTANDARD vs conWAVE showed statistically significant differences in the total scar area (56 ± 32 cm2 vs 51 ± 30 cm2; p = 0.035), dense scar area (36 ± 25 cm2 vs 29 ± 22 cm2; p = 0.002) and number of CC (3.3 ± 1.6 vs 4.8 ± 2.5; p = 0.026). conWAVE collected more points than the conSTANDARD settings (p = 0.001); however, it used fewer points in map construction (p = 0.023). CONCLUSIONS: The multipolar Advisor™ HD Grid Mapping Catheter in conWAVE provides more efficient point acquisition and greater VT substrate definition of the borderzone particularly at the low-voltage range compared to conSTANDARD. This greater resolution within the low-voltage range facilitated CC definition and quantification within the scar, which is essential in guiding the ablation strategy.
Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Catéteres , Cicatriz , Frecuencia Cardíaca , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugíaRESUMEN
BACKGROUND: Re-entrant ventricular tachycardia may be non-inducible or haemodynamically compromising, requiring assessment of the electrophysiological properties of the myocardium during sinus rhythm (i.e., substrate mapping). Areas of heart tissue with slow conduction can act as a critical isthmus for re-entrant electrical excitation and are a potential target for ablation therapy. AIM: To develop and validate a novel metric of local conduction delay in the heart, the amplitude-normalized electrogram area (norm_EA). METHODS: A computational model of a propagating mouse action potential was used to establish the impact of altering sodium channel conductance, intracellular conductivity, fibrosis density, and electrode size/orientation on bipolar electrogram morphology. Findings were then validated in experimental studies in mouse and guinea pig hearts instrumented for the recording of bipolar electrograms from a multipolar linear mapping catheter. norm_EA was calculated by integrating the absolute area of a bipolar electrogram divided by the electrogram amplitude. Electrogram metrics were correlated with the local conduction delay during sodium channel block, gap junction inhibition, and acute ischemia. RESULTS: In computational simulations, reducing sodium channel conductance and intracellular conductivity resulted in a decrease in signal amplitude and increase in norm_EA (reflecting a broadening of electrogram morphology). For larger electrodes (3 mm diameter/7.1 mm2 area), the change in norm_EA was essentially linear with the change in local conduction delay. Experimental studies supported this finding, showing that the magnitude of change in norm_EA induced by flecainide (1-4 µM), carbenoxolone (10-50 µM), and low-flow ischemia (25% of initial flow rate) was linearly correlated with the local conduction delay in each condition (r 2 = 0.92). Qualitatively similar effects were observed in guinea pig hearts perfused with flecainide. Increasing fibrosis density in the computational model also resulted in a decrease in signal amplitude and increase in norm_EA. However, this remains to be validated using experimental/clinical data of chronic infarct. CONCLUSION: norm_EA is a quantitative measure of local conduction delay between the electrode pair that generates a bipolar electrogram, which may have utility in electrophysiological substrate mapping of non-inducible or haemodynamically compromising tachyarrhythmia.