Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Biomed Opt Express ; 11(9): 5297-5305, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-33014615

RESUMEN

Blood-induced shear stress influences gene expression. Abnormal shear stress patterns on the endocardium of the early-stage heart tube can lead to congenital heart defects. To have a better understanding of these mechanisms, it is essential to include shear stress measurements in longitudinal cohort studies of cardiac development. Previously reported approaches are computationally expensive and nonpractical when assessing many animals. Here, we introduce a new approach to estimate shear stress that does not rely on recording 4D image sets and extensive post processing. Our method uses two adjacent optical coherence tomography frames (B-scans) where lumen geometry and flow direction are determined from the structural data and the velocity is measured from the Doppler OCT signal. We validated our shear stress estimate by flow phantom experiments and applied it to live quail embryo hearts where observed shear stress patterns were similar to previous studies.

2.
J Biomed Opt ; 23(4): 1-8, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29704328

RESUMEN

We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (∼100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 µm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.


Asunto(s)
Tomografía de Coherencia Óptica/instrumentación , Tomografía de Coherencia Óptica/métodos , Animales , Efecto Doppler , Embrión no Mamífero/irrigación sanguínea , Embrión no Mamífero/diagnóstico por imagen , Diseño de Equipo , Análisis de Fourier , Hemodinámica/fisiología , Fantasmas de Imagen , Codorniz , Reproducibilidad de los Resultados , Relación Señal-Ruido
3.
J Alzheimers Dis ; 45(3): 921-31, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25633676

RESUMEN

BACKGROUND: Corpus callosum (CC) size and shape have been previously studied in Alzheimer's disease (AD) with the majority of studies having been cross-sectional. Due to the large variance in normal CC morphology, cross-sectional studies are limited in statistical power. Determining individual rates of change requires longitudinal data. Physiological changes are particularly relevant in mild cognitive impairment (MCI), in which CC morphology has not been previously studied longitudinally. OBJECTIVE: To study temporal rates of change in CC morphology in MCI patients over a one-year period, and to determine whether these rates differ between MCI subjects who converted to AD (MCI-C) and those who did not (MCI-NC) over an average (±SD) observation period of 5.4 (±1.6) years. METHODS: We used a novel multi-atlas based algorithm to segment the mid-sagittal cross-sectional area of the CC in longitudinal MRI scans. Rates of change of CC circularity, total area, and five sub-areas were compared between 57 MCI-NC and 81 MCI-C subjects. RESULTS: The CC became less circular (-0.89% per year in MCI-NC, -1.85% per year in MCI-C) with time, with faster decline in MCI-C (p = 0.0002). In females, atrophy rates were higher in MCI-C relative to MCI-NC in total CC area (p = 0.0006), genu/rostrum (p = 0.005), and splenium (0.002). In males, these rates did not differ between groups. CONCLUSION: A greater than normal decline in CC circularity was shown to be an indicator of prodromal AD in MCI subjects. This measure is potentially useful as an imaging biomarker of disease and a therapeutic target in clinical trials.


Asunto(s)
Enfermedad de Alzheimer/patología , Disfunción Cognitiva/patología , Cuerpo Calloso/patología , Síntomas Prodrómicos , Anciano , Anciano de 80 o más Años , Atrofia , Estudios Transversales , Femenino , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Masculino , Estadísticas no Paramétricas
4.
Int J Cardiovasc Imaging ; 31(3): 463-70, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25395364

RESUMEN

Accuracy of IVOCT for measurement of neointimal thickness and effect of neointima in the appearance of metallic struts in IVOCT images was investigated. Phantom vessels were constructed and coronary stents were deployed and covered with thick (250-400 µm) and thin (30-70 µm) phantom neointima. High resolution Micro-CT images of the stent struts were recorded as a gold standard. IVOCT images of the phantom vessels were acquired with various luminal blood scattering strengths and measured neointimal thicknesses from IVOCT and Micro-CT images were compared. In transparent lumen, comparison of IVOCT and Micro-CT neointima thickness measurements found no significant difference (p > 0.05) in the thick neointima phantom but a significant difference (p < 0.05) in the thin neointima phantom. For both thick and thin neointima, IVOCT neointimal thickness measurements varied from Micro-CT values by as much as ±35%. Increased luminal scattering due to presence of blood at concentrations <5% did not interfere with measurement of thin neointimas and was validated by ANOVA analysis (p = 0.95). IV-OCT measurement of strut feature size with an overlying thin neointima match true values determined with Micro-CT (p = 0.82). Presence of a thick neointima resulted in lateral elongation or merry-go-rounding of stent strut features in IVOCT images. Phantom IVOCT images suggest that thick neointimal layers can result in more than 40 % lateral elongation of stent strut features. Simulated IVOCT images of metallic stent struts with varying neointimal thickness suggest that neointimal light scattering can introduce the merry-go-round effect.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/patología , Metales , Neointima , Intervención Coronaria Percutánea/instrumentación , Stents , Tomografía de Coherencia Óptica , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Humanos , Modelos Cardiovasculares , Intervención Coronaria Percutánea/efectos adversos , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica/instrumentación , Microtomografía por Rayos X
5.
J Biomed Opt ; 19(12): 126017, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25545341

RESUMEN

We sought to elucidate the mechanisms underlying two common intravascular optical coherence tomography (IV-OCT) artifacts that occur when imaging metallic stents: "merry-go-rounding" (MGR), which is an increase in strut arc length (SAL), and "blooming," which is an increase in the strut reflection thickness (blooming thickness). Due to uncontrollable variables that occur in vivo, we performed an in vitro assessment of MGR and blooming in stented vessel phantoms. Using Xience V and Driver stents, we examined the effects of catheter offset, intimal strut coverage, and residual blood on SAL and blooming thickness in IV-OCT images. Catheter offset and strut coverage both caused minor MGR, while the greatest MGR effect resulted from light scattering by residual blood in the vessel lumen, with 1% hematocrit (Hct) causing a more than fourfold increase in SAL compared with saline (p<0.001 ). Residual blood also resulted in blooming, with blooming thickness more than doubling when imaged in 0.5% Hct compared with saline (p<0.001 ). We demonstrate that a previously undescribed mechanism, light scattering by residual blood in the imaging field, is the predominant cause of MGR. Light scattering also results in blooming, and a newly described artifact, three-dimensional-MGR, which results in "ghost struts" in B-scans.


Asunto(s)
Artefactos , Procedimientos Endovasculares/métodos , Tomografía de Coherencia Óptica/métodos , Animales , Fenómenos Fisiológicos Sanguíneos , Procesamiento de Imagen Asistido por Computador , Rayos Láser , Luz , Modelos Cardiovasculares , Fantasmas de Imagen , Reproducibilidad de los Resultados , Dispersión de Radiación , Stents , Porcinos
6.
Biomed Opt Express ; 4(10): 1876-82, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24156050

RESUMEN

Effect of beam size and catheter position on the apparent size and apposition of metallic stent struts in IVOCT images were examined. Micro-CT data was employed to determine light - stent strut interactions. Simulated results suggest that location of the reflecting regions depend on relative orientation and position of stent struts to the IVOCT beam. Erroneous stent apposition measurements can occur when the IVOCT catheter is at an eccentric position. A method that mitigates stent strut apposition measurement errors is proposed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA