RESUMEN
Beginning in May 2022, a rising number of monkeypox cases were reported in non-monkeypox-endemic countries in the Northern Hemisphere. We adapted 2 published quantitative PCRs for use as a dual-target monkeypox virus test on widely used automated high-throughput PCR systems. We determined analytic performance by serial dilutions of monkeypox virus reference material, which we quantified by digital PCR. We found the lower limit of detection for the combined assays was 4.795 (95% CI 3.6-8.6) copies/mL. We compared clinical performance against a commercial manual orthopoxvirus research use only PCR kit by using clinical remnant swab samples. Our assay showed 100% positive (n = 11) and 100% negative (n = 56) agreement. Timely and scalable PCR tests are crucial for limiting further spread of monkeypox. The assay we provide streamlines high-throughput molecular testing for monkeypox virus on existing broadly established platforms used for SARS-CoV-2 diagnostic testing.
Asunto(s)
COVID-19 , Mpox , Humanos , Técnicas de Diagnóstico Molecular , Mpox/diagnóstico , Mpox/epidemiología , Monkeypox virus/genética , SARS-CoV-2/genética , Sensibilidad y EspecificidadRESUMEN
Sensitive and specific serological tests are mandatory for epidemiological studies evaluating severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) prevalence as well as coronavirus disease 2019 (COVID-19) morbidity and mortality rates. The accuracy of results is challenged by antibody waning after convalescence and by cross-reactivity induced by previous infections with other pathogens. By employing a patented platform technology based on capturing antigen-antibody complexes with a solid-phase-bound Fcγ receptor (FcγR) and truncated nucleocapsid protein as the antigen, two SARS-CoV-2 IgG enzyme-linked immunosorbent assays (ELISAs), featuring different serum and antigen dilutions, were developed. Validation was performed using a serum panel comprising 213 longitudinal samples from 35 COVID-19 patients and a negative-control panel consisting of 790 pre-COVID-19 samples from different regions of the world. While both assays show similar diagnostic sensitivities in the early convalescent phase, ELISA 2 (featuring a higher serum concentration) enables SARS-CoV-2 IgG antibody detection for a significantly longer time postinfection (≥15 months). Correspondingly, analytical sensitivity referenced to indirect immunofluorescence testing (IIFT) is significantly higher for ELISA 2 in samples with a titer of ≤1:640; for high-titer samples, a prozone effect is observed for ELISA 2. The specificities of both ELISAs were excellent not only for pre-COVID-19 serum samples from Europe, Asia, and South America but also for several challenging African sample panels. The SARS-CoV-2 IgG FcγR ELISAs, methodically combining antigen-antibody binding in solution and isotype-specific detection of immune complexes, are valuable tools for seroprevalence studies requiring the (long-term) detection of anti-SARS-CoV-2 IgG antibodies in populations with a challenging immunological background and/or in which spike-protein-based vaccine programs have been rolled out.
Asunto(s)
COVID-19 , Receptores de IgG , Anticuerpos Antivirales , COVID-19/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Inmunoglobulina G , Proteínas de la Nucleocápside , SARS-CoV-2 , Sensibilidad y Especificidad , Estudios Seroepidemiológicos , Glicoproteína de la Espiga del CoronavirusRESUMEN
We aimed to provide in vitro data on the neutralization capacity of different monoclonal antibody (mAb) preparations against the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) delta and omicron variant, respectively, and describe the in vivo RNA kinetics of coronavirus disease 2019 (COVID-19) patients treated with the respective mAbs. Virus neutralization assays were performed to assess the neutralizing effect of the mAb formulations casirivimab/imdevimab and sotrovimab on the SARS-CoV-2 delta and omicron variant. Additionally, respiratory tract SARS-CoV-2 RNA kinetics are provided for 25 COVID-19 patients infected with either delta variant (n = 18) or omicron variant (n = 7) treated with the respective mAb formulations during their hospital stay. In the virus neutralization assay, sotrovimab exhibits neutralizing capacity at therapeutically achievable concentrations against the SARS-CoV-2 delta and omicron variant. In contrast, casivirimab/imdevimab had neutralizing capacity against the delta variant but failed neutralization against the omicron variant except for a very high concentration above the currently recommended therapeutic dosage. In patients with delta variant infections treated with casivirimab/imdevimab, we observed a rapid decrease of respiratory viral RNA at day 3 after mAb therapy. In contrast, no such prompt decline was observed in patients with delta variant or omicron variant infections receiving sotrovimab.
Asunto(s)
Antineoplásicos Inmunológicos , Tratamiento Farmacológico de COVID-19 , Anticuerpos Monoclonales/uso terapéutico , Anticuerpos Monoclonales Humanizados , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Humanos , Glicoproteínas de Membrana/genética , Pruebas de Neutralización , ARN Viral , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Resultado del Tratamiento , Proteínas del Envoltorio Viral/genéticaRESUMEN
Serological testing for anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies is used to detect ongoing or past SARS-CoV-2 infections. To study the kinetics of anti-SARS-CoV-2 antibodies and to assess the diagnostic performances of eight serological assays, we used 129 serum samples collected on known days post symptom onset (dpso) from 42 patients with polymerase chain reaction-confirmed coronavirus disease 2019 (COVID-19) and 54 serum samples from healthy blood donors, and children infected with seasonal coronaviruses. The sera were analyzed for the presence of immunoglobulin G (IgG), immunoglobulin M (IgM), and immunoglobulin A (IgA) antibodies using indirect immunofluorescence testing (IIFT) based on SARS-CoV-2-infected cells. They were further tested for antibodies against the S1 domain of the SARS-CoV-2 spike protein (IgG, IgA) and against the viral nucleocapsid protein (IgG, IgM) using enzyme-linked immunosorbent assays. The assay specificities were 94.4%-100%. The sensitivities varied largely between assays, reflecting their respective purposes. The sensitivities of IgA and IgM assays were the highest between 11 and 20 dpso, whereas the sensitivities of IgG assays peaked between 20 and 60 dpso. IIFT showed the highest sensitivities due to the use of the whole SARS-CoV-2 as substrate and provided information on whether or not the individual has been infected with SARS-CoV-2. Enzyme-linked immunosorbent assays provided further information about both the prevalence and concentration of specific antibodies against selected antigens of SARS-CoV-2.
Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19 , COVID-19/sangre , SARS-CoV-2/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antivirales/inmunología , COVID-19/diagnóstico , Proteínas de la Nucleocápside de Coronavirus/inmunología , Ensayo de Inmunoadsorción Enzimática , Femenino , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Isotipos de Inmunoglobulinas/sangre , Cinética , Masculino , Persona de Mediana Edad , Fosfoproteínas/inmunología , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/inmunologíaRESUMEN
OBJECTIVES: Specific serological tests are mandatory for reliable SARS-CoV-2 diagnostics and seroprevalence studies. Here, we assess the specificities of four commercially available SARS-CoV-2 IgG ELISAs in serum/plasma panels originating from Africa, South America, and Europe. METHODS: 882 serum/plasma samples collected from symptom-free donors before the COVID-19 pandemic in three African countries (Ghana, Madagascar, Nigeria), Colombia, and Germany were analysed with three nucleocapsid-based ELISAs (Euroimmun Anti-SARS-CoV-2-NCP IgG, EDI™ Novel Coronavirus COVID-19 IgG, Mikrogen recomWell SARS-CoV-2 IgG), one spike/S1-based ELISA (Euroimmun Anti-SARS-CoV-2 IgG), and in-house common cold CoV ELISAs. RESULTS: High specificity was confirmed for all SARS-CoV-2 IgG ELISAs for Madagascan (93.4-99.4%), Colombian (97.8-100.0%), and German (95.9-100.0%) samples. In contrast, specificity was much lower for the Ghanaian and Nigerian serum panels (Ghana: NCP-based assays 77.7-89.7%, spike/S1-based assay 94.3%; Nigeria: NCP-based assays 39.3-82.7%, spike/S1-based assay 90.7%). 15 of 600 African sera were concordantly classified as positive in both the NCP-based and the spike/S1-based Euroimmun ELISA, but did not inhibit spike/ACE2 binding in a surrogate virus neutralisation test. IgG antibodies elicited by previous infections with common cold CoVs were found in all sample panels, including those from Madagascar, Colombia, and Germany and thus do not inevitably hamper assay specificity. Nevertheless, high levels of IgG antibodies interacting with OC43 NCP were found in all 15 SARS-CoV-2 NCP/spike/S1 ELISA positive sera. CONCLUSIONS: Depending on the chosen antigen and assay protocol, SARS-CoV-2 IgG ELISA specificity may be significantly reduced in certain populations probably due to interference of immune responses to endemic pathogens like other viruses or parasites.
Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Inmunoglobulina G/sangre , Adolescente , Adulto , COVID-19/virología , Niño , Preescolar , Colombia , Proteínas de la Nucleocápside de Coronavirus/inmunología , Femenino , Alemania , Ghana , Humanos , Madagascar , Masculino , Persona de Mediana Edad , Nigeria , SARS-CoV-2/inmunología , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/inmunología , Adulto JovenRESUMEN
IntroductionNumerous CE-marked SARS-CoV-2 antigen rapid diagnostic tests (Ag RDT) are offered in Europe, several of them with unconfirmed quality claims.AimWe performed an independent head-to-head evaluation of the sensitivity of SARS-CoV-2 Ag RDT offered in Germany.MethodsWe addressed the sensitivity of 122 Ag RDT in direct comparison using a common evaluation panel comprised of 50 specimens. Minimum sensitivity of 75% for panel specimens with a PCR quantification cycle (Cq) ≤ 25 was used to identify Ag RDT eligible for reimbursement in the German healthcare system.ResultsThe sensitivity of different SARS-CoV-2 Ag RDT varied over a wide range. The sensitivity limit of 75% for panel members with Cq ≤ 25 was met by 96 of the 122 tests evaluated; 26 tests exhibited lower sensitivity, few of which failed completely. Some RDT exhibited high sensitivity, e.g. 97.5 % for Cq < 30.ConclusionsThis comparative evaluation succeeded in distinguishing less sensitive from better performing Ag RDT. Most of the evaluated Ag RDT appeared to be suitable for fast identification of acute infections associated with high viral loads. Market access of SARS-CoV-2 Ag RDT should be based on minimal requirements for sensitivity and specificity.
Asunto(s)
COVID-19 , SARS-CoV-2 , Antígenos Virales , Pruebas Diagnósticas de Rutina , Alemania , Humanos , Sensibilidad y EspecificidadRESUMEN
IntroductionThe detection of SARS-CoV-2 with rapid diagnostic tests (RDT) has become an important tool to identify infected people and break infection chains. These RDT are usually based on antigen detection in a lateral flow approach.AimWe aimed to establish a comprehensive specimen panel for the decentralised technical evaluation of SARS-CoV-2 antigen rapid diagnostic tests.MethodsWhile for PCR diagnostics the validation of a PCR assay is well established, there is no common validation strategy for antigen tests, including RDT. In this proof-of-principle study we present the establishment of a panel of 50 pooled clinical specimens that cover a SARS-CoV-2 concentration range from 1.1â¯×â¯109 to 420 genome copies per mL of specimen. The panel was used to evaluate 31 RDT in up to six laboratories.ResultsOur results show that there is considerable variation in the detection limits and the clinical sensitivity of different RDT. We show that the best RDT can be applied to reliably identify infectious individuals who present with SARS-CoV-2 loads down to 106 genome copies per mL of specimen. For the identification of infected individuals with SARS-CoV-2 loads corresponding to less than 106 genome copies per mL, only three RDT showed a clinical sensitivity of more than 60%.ConclusionsSensitive RDT can be applied to identify infectious individuals with high viral loads but not to identify all infected individuals.
Asunto(s)
COVID-19 , SARS-CoV-2 , Antígenos Virales , Pruebas Diagnósticas de Rutina , Humanos , Sensibilidad y Especificidad , Pruebas SerológicasRESUMEN
Crimean-Congo hemorrhagic fever (CCHF) is a widely distributed, viral, tickborne disease. In Europe, cases have been reported only in the southeastern part of the continent. We report two autochthonous cases in Spain. The index patient acquired the disease through a tick bite in the province of Ávila - 300 km away from the province of Cáceres, where viral RNA from ticks was amplified in 2010. The second patient was a nurse who became infected while caring for the index patient. Both were infected with the African 3 lineage of this virus. (Funded by Red de Investigación Cooperativa en Enfermedades Tropicales [RICET] and Efficient Response to Highly Dangerous and Emerging Pathogens at EU [European Union] Level [EMERGE].).
Asunto(s)
Virus de la Fiebre Hemorrágica de Crimea-Congo/aislamiento & purificación , Fiebre Hemorrágica de Crimea , Colon/patología , Trazado de Contacto , Resultado Fatal , Femenino , Virus de la Fiebre Hemorrágica de Crimea-Congo/clasificación , Virus de la Fiebre Hemorrágica de Crimea-Congo/genética , Fiebre Hemorrágica de Crimea/patología , Fiebre Hemorrágica de Crimea/transmisión , Fiebre Hemorrágica de Crimea/virología , Humanos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional , Hígado/patología , Masculino , Persona de Mediana Edad , Necrosis , Reacción en Cadena de la Polimerasa , EspañaRESUMEN
During 2013-2016, a total of 32 patients were treated for Crimean-Congo hemorrhagic fever in Prishtina, Kosovo; 11 died. In the 11 patients who died, findings included viral loads >1 × 108.5/mL, lactate dehydrogenase >2,700 U/mL, bleeding, and impaired consciousness. Ribavirin therapy had no noticeable effect in this small patient sample.
Asunto(s)
Virus de la Fiebre Hemorrágica de Crimea-Congo , Fiebre Hemorrágica de Crimea/epidemiología , Fiebre Hemorrágica de Crimea/virología , Adolescente , Adulto , Anciano , Biomarcadores , Niño , Preescolar , Femenino , Geografía , Fiebre Hemorrágica de Crimea/historia , Historia del Siglo XXI , Humanos , Lactante , Recién Nacido , Kosovo/epidemiología , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Carga Viral , Adulto JovenRESUMEN
BACKGROUND: The cellular surface molecule HsTOSO/FAIM3/HsFcµR has been identified as an IgM-specific Fc receptor expressed on lymphocytes. Here, we show that its extracellular immunoglobulin-like domain (HsFcµR-Igl) specifically binds to IgM/antigen immune complexes (ICs) and exploit this property for the development of novel detection systems for IgM antibodies directed against Crimean-Congo hemorrhagic fever virus (CCHFV) and Zika virus (ZIKV). METHODS: His-tagged HsFcµR-Igl was expressed in Escherichia coli and purified by affinity chromatography, oxidative refolding, and size-exclusion chromatography. Specific binding of HsFcµR-Igl to IgM/antigen ICs was confirmed, and 2 prototypic ELISAs for the detection of anti-CCHFV and anti-ZIKV IgM antibodies were developed. Thereby, patient sera and virus-specific recombinant antigens directly labeled with horseradish peroxidase (HRP) were coincubated on HsFcµR-Igl-coated ELISA plates. Bound ICs were quantified by measuring turnover of a chromogenic HRP substrate. RESULTS: Assay validation was performed using paired serum samples from 15 Kosovar patients with a PCR-confirmed CCHFV infection and 28 Brazilian patients with a PCR-confirmed ZIKV infection, along with a panel of a priori CCHFV/ZIKV-IgM-negative serum samples. Both ELISAs were highly reproducible. Sensitivity and specificity were comparable with or even exceeded in-house gold standard testing and commercial kits. Furthermore, latex beads coated with HsFcµR-Igl aggregated upon coincubation with an IgM-positive serum and HRP-labeled antigen but not with either component alone, revealing a potential for use of HsFcµR-Igl as a capture molecule in aggregation-based rapid tests. CONCLUSIONS: Recombinant HsFcµR-Igl is a versatile capture molecule for IgM/antigen ICs of human and animal origin and can be applied for the development of both plate- and bead-based serological tests.
Asunto(s)
Anticuerpos Antivirales/sangre , Virus de la Fiebre Hemorrágica de Crimea-Congo/inmunología , Inmunoglobulina M/sangre , Virus Zika/inmunología , Animales , Anticuerpos Antivirales/metabolismo , Proteínas Reguladoras de la Apoptosis/metabolismo , Secuencia de Bases , Ensayo de Inmunoadsorción Enzimática/métodos , Fiebre Hemorrágica de Crimea/diagnóstico , Humanos , Dominios de Inmunoglobulinas , Inmunoglobulina M/metabolismo , Proteínas de la Membrana/metabolismo , Unión Proteica , Pruebas Serológicas/métodos , Infección por el Virus Zika/diagnósticoRESUMEN
The newly identified tick-borne Alongshan virus (ALSV), a segmented Jingmen virus group flavivirus, was recently associated with human disease in China. We report the detection of ALSV RNA in Ixodes ricinus ticks in south-eastern Finland. Screening of sera from patients suspected for tick-borne encephalitis for Jingmen tick virus-like virus RNA and antibodies revealed no human cases. The presence of ALSV in common European ticks warrants further investigations on its role as a human pathogen.
Asunto(s)
Virus de la Encefalitis Transmitidos por Garrapatas/genética , Virus de la Encefalitis Transmitidos por Garrapatas/aislamiento & purificación , Encefalitis Transmitida por Garrapatas/virología , Ixodes/virología , ARN Viral/genética , Suero/virología , Animales , Secuencia de Bases , Finlandia , Humanos , Datos de Secuencia Molecular , Filogenia , ARN Viral/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Análisis de SecuenciaRESUMEN
We describe a strain of Lassa virus representing a putative new lineage that was isolated from a cluster of human infections with an epidemiologic link to Togo. This finding extends the known range of Lassa virus to Togo.
Asunto(s)
Fiebre de Lassa/epidemiología , Fiebre de Lassa/virología , Virus Lassa/clasificación , Animales , Chlorocebus aethiops , Genes Virales , Historia del Siglo XXI , Humanos , Fiebre de Lassa/historia , Filogenia , Togo/epidemiología , Células VeroRESUMEN
During 2006-2015, we analyzed 70 dengue virus (DENV) strains isolated from febrile travelers returning to Germany. High genetic diversity, including multiple co-circulating DENV lineages and emerging new lineages of DENV-3 and DENV-4, was demonstrated. Our passive surveillance system based on returning travelers yielded substantial information on DENV diversity.
Asunto(s)
Virus del Dengue/clasificación , Virus del Dengue/genética , Dengue/epidemiología , Dengue/virología , Variación Genética , Viaje , Dengue/historia , Dengue/transmisión , Virus del Dengue/aislamiento & purificación , Genotipo , Geografía Médica , Alemania/epidemiología , Historia del Siglo XXI , Humanos , Filogenia , Vigilancia en Salud Pública , SerogrupoRESUMEN
Ebola virus disease (EVD) developed in a patient who contracted the disease in Sierra Leone and was airlifted to an isolation facility in Hamburg, Germany, for treatment. During the course of the illness, he had numerous complications, including septicemia, respiratory failure, and encephalopathy. Intensive supportive treatment consisting of high-volume fluid resuscitation (approximately 10 liters per day in the first 72 hours), broad-spectrum antibiotic therapy, and ventilatory support resulted in full recovery without the use of experimental therapies. Discharge was delayed owing to the detection of viral RNA in urine (day 30) and sweat (at the last assessment on day 40) by means of polymerase-chain-reaction (PCR) assay, but the last positive culture was identified in plasma on day 14 and in urine on day 26. This case shows the challenges in the management of EVD and suggests that even severe EVD can be treated effectively with routine intensive care.
Asunto(s)
Antiinfecciosos/uso terapéutico , Bacteriemia/etiología , Infecciones por Bacterias Gramnegativas/etiología , Fiebre Hemorrágica Ebola/terapia , Adulto , Bacteriemia/tratamiento farmacológico , Cuidados Críticos , Diarrea/etiología , Diarrea/terapia , Ebolavirus/genética , Ebolavirus/aislamiento & purificación , Fluidoterapia , Infecciones por Bacterias Gramnegativas/tratamiento farmacológico , Fiebre Hemorrágica Ebola/complicaciones , Hepatitis B Crónica/complicaciones , Humanos , Masculino , Nutrición Parenteral , ARN Viral/sangre , Sierra Leona , Carga ViralRESUMEN
The recent spread of Zika virus (ZIKV) in the Americas and Asia necessitates an increased preparedness for improved maternal and perinatal health and blood safety. However, serological cross-reactions, especially to Dengue virus (DENV), complicate ZIKV antibody serodiagnosis. A novel "pan-Flavi" suspension multiplex immunoassay (PFSMIA) using 25 antigens, whole virus (WV), non-structural protein 1 (NS1), and envelope (E) proteins, from 7 zoonotic flaviviruses for specific detection of ZIKV and DENV IgM and IgG was developed. Patterns of antibody cross-reactivity, avidity, and kinetics were established in 104 sera from returning travelers with known ZIKV and DENV infections. PFSMIA gave IgM- and IgG-sensitivities for both viruses of 96-100%, compared to an immunofluorescence assay. Main IgM cross-reactions were to NS1, for IgG to the E and WV antigens. Infecting virus yielded reactivity to several antigens of the homologous virus, while cross-reactions tended to occur only to a single antigen from heterologous virus(es). A specificity-enhancing computer procedure took into account antibody isotype, number of antibody-reactive antigens per virus, avidity, average degree of cross-reactivity to heterologous flavivirus antigens, and reactivity changes in serial sera. It classified all 50 cases correctly. Applied to sera from 200 pregnant women and 173 blood donors from Sweden, one blood donor was found ZIKV NS1 IgM positive, and another as ZIKV NS1 IgG positive. These samples did not react with other ZIKV antigens and were thereby judged as false-positives. PFSMIA provided sensitive and specific ZIKV and DENV serology, warranting high-throughput serological surveillance and a minimized need for laborious and expensive virus neutralization assays.
Asunto(s)
Anticuerpos Antivirales/sangre , Reacciones Cruzadas , Pruebas Diagnósticas de Rutina/métodos , Inmunoensayo/métodos , Pruebas Serológicas/métodos , Infección por el Virus Zika/diagnóstico , Afinidad de Anticuerpos , Femenino , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Embarazo , Sensibilidad y Especificidad , Programas InformáticosRESUMEN
In a patient transferred from Togo to Cologne, Germany, Lassa fever was diagnosed 12 days post mortem. Sixty-two contacts in Cologne were categorised according to the level of exposure, and gradual infection control measures were applied. No clinical signs of Lassa virus infection or Lassa specific antibodies were observed in the 62 contacts. Thirty-three individuals had direct contact to blood, other body fluids or tissue of the patients. Notably, with standard precautions, no transmission occurred between the index patient and healthcare workers. However, one secondary infection occurred in an undertaker exposed to the corpse in Rhineland-Palatinate, who was treated on the isolation unit at the University Hospital of Frankfurt. After German authorities raised an alert regarding the imported Lassa fever case, an American healthcare worker who had cared for the index patient in Togo, and who presented with diarrhoea, vomiting and fever, was placed in isolation and medevacked to the United States. The event and the transmission of Lassa virus infection outside of Africa underlines the need for early diagnosis and use of adequate personal protection equipment (PPE), when highly contagious infections cannot be excluded. It also demonstrates that larger outbreaks can be prevented by infection control measures, including standard PPE.
Asunto(s)
Trazado de Contacto , Brotes de Enfermedades/prevención & control , Control de Infecciones/métodos , Fiebre de Lassa/diagnóstico , Viaje , Alemania , Humanos , Masculino , Persona de Mediana Edad , Cuarentena , Gestión de Riesgos , TogoRESUMEN
Serological diagnosis of Zika virus (ZIKV) infections is challenging due to high cross-reactivity between flaviviruses. We evaluated the diagnostic performance of a novel anti-ZIKV ELISA based on recombinant ZIKV non-structural protein 1 (NS1). Assay sensitivity was examined using sera from 27 patients with reverse transcription (RT)-PCR-confirmed and 85 with suspected ZIKV infection. Specificity was analysed using sera from 1,015 healthy individuals. Samples from 252 patients with dengue virus (n = 93), West Nile virus (n = 34), Japanese encephalitis virus (n = 25), chikungunya virus (n = 19) or Plasmodium spp. (n = 69) infections and from 12 yellow fever-vaccinated individuals were also examined. In confirmed ZIKV specimens collected ≥ 6 days after symptom onset, ELISA sensitivity was 58.8% (95% confidence interval (CI): 36.0-78.4) for IgM, 88.2% (95% CI: 64.4-98.0) for IgG, and 100% (95% CI: 78.4-100) for IgM/IgG, at 99.8% (95% CI: 99.2-100) specificity. Cross-reactivity with high-level dengue virus antibodies was not detected. Among patients with potentially cross-reactive antibodies anti-ZIKV positive rates were 0.8% (95% CI: 0-3.0) and 0.4% (95% CI: 0-2.4) for IgM and IgG, respectively. Providing high specificity and low cross-reactivity, the NS1-based ELISA has the potential to aid in counselling patients, pregnant women and travellers after returning from ZIKV-endemic areas.
Asunto(s)
Anticuerpos Antivirales/sangre , Ensayo de Inmunoadsorción Enzimática/métodos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Pruebas Serológicas/métodos , Infección por el Virus Zika/diagnóstico , Virus Zika/aislamiento & purificación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Estudios de Cohortes , Reacciones Cruzadas , Humanos , Lactante , Recién Nacido , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Proteínas no Estructurales Virales/genética , Proteínas no Estructurales Virales/inmunología , Adulto Joven , Virus Zika/inmunología , Infección por el Virus Zika/sangre , Infección por el Virus Zika/inmunologíaRESUMEN
Serodiagnostic tests for antibody detection to estimate the immunoprotective status regarding SARS-CoV-2 support diagnostic management. This study aimed to investigate the performance of serological assays for COVID-19 and elaborate on test-specific characteristics. Sequential samples (n = 636) of four panels (acute COVID-19, convalescent COVID-19 (partly vaccinated post-infection), pre-pandemic, and cross-reactive) were tested for IgG by indirect immunofluorescence test (IIFT) and EUROIMMUN EUROLINE Anti-SARS-CoV-2 Profile (IgG). Neutralizing antibodies were determined by a virus neutralization test (VNT) and two surrogate neutralization tests (sVNT, GenScript cPass, and EUROIMMUN SARS-CoV-2 NeutraLISA). Analysis of the acute and convalescent panels revealed high positive (78.3% and 91.6%) and negative (91.6%) agreement between IIFT and Profile IgG. The sVNTs revealed differences in their positive (cPass: 89.4% and 97.0%, NeutraLISA: 71.5% and 72.1%) and negative agreement with VNT (cPass: 92.3% and 50.0%, NeutraLISA: 95.1% and 92.5%) at a diagnostic specificity of 100% for all tests. The cPass showed higher inhibition rates than NeutraLISA at VNT titers below 1:640. Cross-reactivities were only found by cPass (57.1%). Serodiagnostic tests, which showed substantial agreement and fast runtime, could provide alternatives for cell-based assays. The findings of this study suggest that careful interpretation of serodiagnostic results obtained at different times after SARS-CoV-2 antigen exposure is crucial to support decision-making in diagnostic management.
Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , Inmunidad Humoral , SARS-CoV-2 , Pruebas Serológicas , Inmunoglobulina G , Prueba de COVID-19RESUMEN
Objectives: We report prolonged mpox (>14 weeks) in a patient with HIV complicated by deep tissue MPXV infection despite two courses of tecovirimat treatment. Methods: MPXV-DNA levels in lesional swabs, blood and tissue were quantified by qPCR. Anti-MPXV antibodies were analyzed by IF and VNT. Infectivity was assessed by virus isolation. Sequencing was performed to assess for tecovirimat resistance mutations and quantitative results were obtained by digital SNP PCR (A288P). Results: The patient's clinical condition improved significantly during both tecovirimat treatment courses (each 14 days), yet we observed persistent MPXV-DNA in lesions accompanied by viremia (mean 1.4 × 104 copies/ml) for >14 weeks. A deep tissue infection driven by MPXV complicated the clinical course (week 9). Presence of infectious virus within the tissue and high infectious titers (>106 PFU/ml) were observed. The VP37 protein sequence revealed A288P substitutions. Digital PCR showed 1 % and less abundance (A288P) during first treatment course (blood and swabs), with increasing proportion during second course (week 8-9; 28 % in blood and swabs), however the mutation was absent in samples from deep tissue infection and MPXV isolates (week 9) indicating compartimentalization. Morphological fully enveloped MPXV partices visualized by TEM in necrotic areas suggesting tecovirimat treatment failure in the deep tissue compartment. Conclusion: Our data provide evidence that Tecovirimat treatment selects for compartimentalized viral mutations (A288P). While the patient clinically benefited from repeated tecovirimat course, emergence of viral muations and deep tissue infection emphasizes the challenge and importance of infectious disease monitoring in mpox patient management.
RESUMEN
OBJECTIVES: To assess the public health relevance of Lassa arenavirus and hantavirus infections in a subpopulation of recently febrile patients. METHODS: In a human seroprevalence study, we enrolled 253 participants on the basis of reported high fever during the last 3 months. They represented roughly 20% of the population of Bantou and Tanganya villages. Comprehensive serological screening and confirmatory assays (enzyme-linked immunosorbent assay, immunofluorescence assay, Western blot analysis) with several Lassa virus and hantavirus antigens were used to ensure high specificity and broad detection capacity. RESULTS: We found a Lassa IgG prevalence of 40.3% (102/253) and a hantavirus IgG prevalence of 1.2% (3/253). The Lassa IgM prevalence reached 2.8% (7/253). CONCLUSIONS: High Lassa virus seroprevalence in recently febrile patients indicates that Lassa fever is a significant public health problem in the region. Human hantavirus infections also occur in the region but their public health relevance remains to be determined.