Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Respir Res ; 24(1): 215, 2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37649012

RESUMEN

RATIONALE: X-ray velocimetry (XV) has been utilized in preclinical models to assess lung motion and regional ventilation, though no studies have compared XV-derived physiologic parameters to measures derived through conventional means. OBJECTIVES: To assess agreement between XV-analysis of fluoroscopic lung images and pitot tube flowmeter measures of ventilation. METHODS: XV- and pitot tube-derived ventilatory parameters were compared during tidal breathing and with bilevel-assisted breathing. Levels of agreement were assessed using the Bland-Altman analysis. Mixed models were used to characterize the association between XV- and pitot tube-derived values and optimize XV-derived values for higher ventilatory volumes. MEASUREMENTS AND MAIN RESULTS: Twenty-four healthy volunteers were assessed during tidal breathing and 11 were reassessed with increased minute ventilation with bilevel-assisted breathing. No clinically significant differences were observed between the two methods for respiratory rate (average Δ: 0.58; 95% limits of agreement: -1.55, 2.71) or duty cycle (average Δ: 0.02; 95% limits of agreement: 0.01, 0.03). Tidal volumes and flow rates measured using XV were lower than those measured using the pitot tube flowmeter, particularly at the higher volume ranges with bilevel-assisted breathing. Under these conditions, a mixed-model based adjustment was applied to the XV-derived values of tidal volume and flow rate to obtain closer agreement with the pitot tube-derived values. CONCLUSION: Radiographically obtained measures of ventilation with XV demonstrate a high degree of correlation with parameters of ventilation. If the accuracy of XV were also confirmed for assessing the regional distribution of ventilation, it would provide information that goes beyond the scope of conventional pulmonary function tests or static radiographic assessments.


Asunto(s)
Pulmón , Respiración , Adulto , Humanos , Rayos X , Radiografía , Volumen de Ventilación Pulmonar , Pulmón/diagnóstico por imagen
2.
Am J Respir Cell Mol Biol ; 67(4): 423-429, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35687482

RESUMEN

The current standard for lung function evaluation in murine models is based on forced oscillation technology, which provides a measure of the total airway function but cannot provide information on regional heterogeneity in function. Limited detection of regional airflow may contribute to a discontinuity between airway inflammation and airflow obstruction in models of asthma. Here, we describe quantification of regional airway function using novel dynamic quantitative imaging and analysis to quantify and visualize lung motion and regional pulmonary airflow in four dimensions (4D). Furthermore, temporo-spatial specific ventilation (ml/ml) is used to determine ventilation heterogeneity indices for lobar and sublobar regions, which are directly compared to ex vivo biological analyses in the same sublobar regions. In contrast, oscillation-based technology in murine genetic models of asthma have failed to demonstrate lung function change despite altered inflammation, whereas 4D functional lung imaging demonstrated diminished regional lung function in genetic models relative to wild-type mice. Quantitative functional lung imaging assists in localizing the regional effects of airflow. Our approach reveals repeatable and consistent differences in regional airflow between lung lobes in all models of asthma, suggesting that asthma is characterized by regional airway dysfunctions that are often not detectable in composite measures of lung function. 4D functional lung imaging technology has the potential to transform discovery and development in murine models by mapping out regional areas heterogeneously affected by the disease, thus deciphering pathobiology with greater precision.


Asunto(s)
Asma , Pulmón , Animales , Asma/diagnóstico por imagen , Modelos Animales de Enfermedad , Inflamación , Pulmón/diagnóstico por imagen , Ratones , Respiración
3.
Respir Res ; 23(1): 35, 2022 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-35183181

RESUMEN

BACKGROUND: Lung inhomogeneity plays a pivotal role in the development of ventilator-induced lung injury (VILI), particularly in the context of pre-existing lung injury. The mechanisms that underlie this interaction are poorly understood. We aimed to elucidate the regional transcriptomic response to mechanical ventilation (MV), with or without pre-existing lung injury, and link this to the regional lung volume response to MV. METHODS: Adult female BALB/c mice were randomly assigned into one of four groups: Saline, MV, lipopolysaccharide (LPS) or LPS/MV. Lung volumes (tidal volume, Vt; end-expiratory volume, EEV) were measured at baseline or after 2 h of ventilation using four-dimensional computed tomography (4DCT). Regional lung tissue samples corresponding to specific imaging regions were analysed for the transcriptome response by RNA-Seq. Bioinformatics analyses were conducted and the regional expression of dysregulated gene clusters was then correlated with the lung volume response. RESULTS: MV in the absence of pre-existing lung injury was associated with regional variations in tidal stretch. The addition of LPS also caused regional increases in EEV. We identified 345, 141 and 184 region-specific differentially expressed genes in response to MV, LPS and LPS/MV, respectively. Amongst these candidate genes, up-regulation of genes related to immune responses were positively correlated with increased regional tidal stretch in the MV group, while dysregulation of genes associated with endothelial barrier related pathways were associated with increased regional EEV and Vt when MV was combined with LPS. Further protein-protein interaction analysis led to the identification of two protein clusters representing the PI3K/Akt and MEK/ERK signalling hubs which may explain the interaction between MV and LPS exposure. CONCLUSION: The biological pathways associated with lung volume inhomogeneity during MV, and MV in the presence of pre-existing inflammation, differed. MV related tidal stretch induced up-regulation of immune response genes, while LPS combined with MV disrupted PI3K/Akt and MEK/ERK signalling.


Asunto(s)
Lesión Pulmonar/genética , Mediciones del Volumen Pulmonar/métodos , Respiración Artificial/métodos , Volumen de Ventilación Pulmonar/fisiología , Transcriptoma/genética , Animales , Modelos Animales de Enfermedad , Femenino , Lesión Pulmonar/fisiopatología , Lesión Pulmonar/terapia , Ratones , Ratones Endogámicos BALB C , Transducción de Señal
4.
Respirology ; 27(10): 818-833, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35965430

RESUMEN

In recent years, pulmonary imaging has seen enormous progress, with the introduction, validation and implementation of new hardware and software. There is a general trend from mere visual evaluation of radiological images to quantification of abnormalities and biomarkers, and assessment of 'non visual' markers that contribute to establishing diagnosis or prognosis. Important catalysts to these developments in thoracic imaging include new indications (like computed tomography [CT] lung cancer screening) and the COVID-19 pandemic. This review focuses on developments in CT, radiomics, artificial intelligence (AI) and x-ray velocimetry for imaging of the lungs. Recent developments in CT include the potential for ultra-low-dose CT imaging for lung nodules, and the advent of a new generation of CT systems based on photon-counting detector technology. Radiomics has demonstrated potential towards predictive and prognostic tasks particularly in lung cancer, previously not achievable by visual inspection by radiologists, exploiting high dimensional patterns (mostly texture related) on medical imaging data. Deep learning technology has revolutionized the field of AI and as a result, performance of AI algorithms is approaching human performance for an increasing number of specific tasks. X-ray velocimetry integrates x-ray (fluoroscopic) imaging with unique image processing to produce quantitative four dimensional measurement of lung tissue motion, and accurate calculations of lung ventilation.


Asunto(s)
COVID-19 , Neoplasias Pulmonares , Inteligencia Artificial , COVID-19/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Pandemias , Reología , Tomografía Computarizada por Rayos X/métodos , Rayos X
5.
Am J Physiol Lung Cell Mol Physiol ; 318(3): L494-L499, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31940217

RESUMEN

Both overdistension and atelectasis contribute to lung injury and mortality during mechanical ventilation. It has been proposed that combinations of tidal volume and end-expiratory lung volume exist that minimize lung injury linked to mechanical ventilation. The aim of this study was to examine this at the regional level in the healthy and endotoxemic lung. Adult female BALB/c mice were injected intraperitoneally with 10 mg/kg lipopolysaccharide (LPS) in saline or with saline alone. Four hours later, mice were mechanically ventilated for 2 h. Regional specific end-expiratory volume (sEEV) and tidal volume (sVt) were measured at baseline and after 2 h of ventilation using dynamic high-resolution four-dimensional computed tomography images. The regional expression of inflammatory genes was quantified by quantitative PCR. There was a heterogenous response in regional sEEV whereby endotoxemia increased gas trapping at end-expiration in some lung regions. Within the healthy group, there was a relationship between sEEV, sVt, and the expression of Tnfa, where high Vt in combination with high EEV or very low EEV was associated with an increase in gene expression. In endotoxemia there was an association between low sEEV, particularly when this was combined with moderate sVt, and high expression of IL6. Our data suggest that preexisting systemic inflammation modifies the relationship between regional lung volumes and inflammation and that although optimum EEV-Vt combinations to minimize injury exist, further studies are required to identify the critical inflammatory mediators to assess and the effect of different injury types on the response.


Asunto(s)
Endotoxemia/complicaciones , Inflamación/etiología , Pulmón/fisiopatología , Lesión Pulmonar Inducida por Ventilación Mecánica/etiología , Animales , Femenino , Perfilación de la Expresión Génica , Inflamación/metabolismo , Inflamación/patología , Ratones , Ratones Endogámicos BALB C , Respiración Artificial , Volumen de Ventilación Pulmonar , Lesión Pulmonar Inducida por Ventilación Mecánica/metabolismo , Lesión Pulmonar Inducida por Ventilación Mecánica/patología
6.
Am J Respir Cell Mol Biol ; 60(5): 569-577, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30428271

RESUMEN

The aim of this study was to assess the association between regional tidal volume (Vt), regional functional residual capacity (FRC), and the expression of genes linked with ventilator-induced lung injury. Two groups of BALB/c mice (n = 8 per group) were ventilated for 2 hours using a protective or injurious ventilation strategy, with free-breathing mice used as control animals. Regional Vt and FRC of the ventilated mice was determined by analysis of high-resolution four-dimensional computed tomographic images taken at baseline and after 2 hours of ventilation and corrected for the volume of the region (i.e., specific [s]Vt and specific [s]FRC). RNA concentrations of 21 genes in 10 different lung regions were quantified using a quantitative PCR array. sFRC at baseline varied regionally, independent of ventilation strategy, whereas sVt varied regionally depending on ventilation strategy. The expression of IL-6 (P = 0.04), Ccl2 (P < 0.01), and Ang-2 (P < 0.05) was associated with sVt but not sFRC. The expression of seven other genes varied regionally (IL-1ß and RAGE [receptor for advanced glycation end products]) or depended on ventilation strategy (Nfe2l2 [nuclear factor erythroid-derived 2 factor 2], c-fos, and Wnt1) or both (TNF-α and Cxcl2), but it was not associated with regional sFRC or sVt. These observations suggest that regional inflammatory responses to mechanical ventilation are driven primarily by tidal stretch.


Asunto(s)
Fenómenos Biomecánicos/inmunología , Regulación de la Expresión Génica/inmunología , Pulmón/inmunología , Respiración Artificial/métodos , Lesión Pulmonar Inducida por Ventilación Mecánica/genética , Animales , Líquido del Lavado Bronquioalveolar/química , Líquido del Lavado Bronquioalveolar/inmunología , Quimiocina CCL2/genética , Quimiocina CCL2/inmunología , Quimiocina CXCL2/genética , Quimiocina CXCL2/inmunología , Tomografía Computarizada Cuatridimensional , Interpretación de Imagen Asistida por Computador , Interleucina-1beta/genética , Interleucina-1beta/inmunología , Interleucina-6/genética , Interleucina-6/inmunología , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Masculino , Ratones , Ratones Endogámicos BALB C , Factor 2 Relacionado con NF-E2/genética , Factor 2 Relacionado con NF-E2/inmunología , Proteínas Proto-Oncogénicas c-fos/genética , Proteínas Proto-Oncogénicas c-fos/inmunología , Receptor para Productos Finales de Glicación Avanzada/genética , Receptor para Productos Finales de Glicación Avanzada/inmunología , Ribonucleasa Pancreática/genética , Ribonucleasa Pancreática/inmunología , Transducción de Señal , Volumen de Ventilación Pulmonar/genética , Volumen de Ventilación Pulmonar/inmunología , Factor de Necrosis Tumoral alfa/genética , Factor de Necrosis Tumoral alfa/inmunología , Lesión Pulmonar Inducida por Ventilación Mecánica/diagnóstico por imagen , Lesión Pulmonar Inducida por Ventilación Mecánica/inmunología , Lesión Pulmonar Inducida por Ventilación Mecánica/fisiopatología , Proteína Wnt1/genética , Proteína Wnt1/inmunología
7.
Pediatr Res ; 82(3): 536-543, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28399114

RESUMEN

BackgroundA congenital diaphragmatic hernia (DH) can result in severe lung hypoplasia that increases the risk of morbidity and mortality after birth; however, little is known about the cardiorespiratory transition at birth.MethodsUsing phase-contrast X-ray imaging and angiography, we examined the cardiorespiratory transition at birth in rabbit kittens with DHs. Surgery was performed on pregnant New Zealand white rabbits (n=18) at 25 days' gestation to induce a left-sided DH. Kittens were delivered at 30 days' gestation, intubated, and ventilated to achieve a tidal volume (Vt) of 8 ml/kg in control and 4 ml/kg in DH kittens while they were imaged.ResultsFunctional residual capacity (FRC) recruitment and Vt in the hypoplastic left lung were markedly reduced, resulting in a disproportionate distribution of FRC into the right lung. Following lung aeration, relative pulmonary blood flow (PBF) increased equally in both lungs, and the increase in pulmonary venous return was similar in both control and DH kittens.ConclusionThese findings indicate that nonuniform lung hypoplasia caused by DH alters the distribution of ventilation away from hypoplastic and into normally grown lung regions. During transition, the increase in PBF and pulmonary venous return, which is vital for maintaining cardiac output, is not affected by lung hypoplasia.


Asunto(s)
Hernias Diafragmáticas Congénitas/fisiopatología , Pulmón/irrigación sanguínea , Ventilación Pulmonar , Animales , Animales Recién Nacidos , Femenino , Hernias Diafragmáticas Congénitas/diagnóstico por imagen , Hernias Diafragmáticas Congénitas/patología , Embarazo , Conejos , Flujo Sanguíneo Regional , Volumen de Ventilación Pulmonar
8.
J Physiol ; 594(5): 1389-98, 2016 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-26278276

RESUMEN

Lung aeration stimulates the increase in pulmonary blood flow (PBF) at birth, but the spatial relationships between PBF and lung aeration and the role of increased oxygenation remain unclear. Using simultaneous phase-contrast X-ray imaging and angiography, we have investigated the separate roles of lung aeration and increased oxygenation in PBF changes at birth using near-term (30 days of gestation) rabbit kits (n = 18). Rabbits were imaged before ventilation, then the right lung was ventilated with 100% nitrogen (N2), air or 100% O2 (oxygen), before all kits were switched to ventilation in air, followed by ventilation of both lungs using air. Unilateral ventilation of the right lung with 100% N2 significantly increased heart rate (from 69.4 ± 4.9 to 93.0 ± 15.0 bpm), the diameters of both left and right pulmonary axial arteries, number of visible vessels in both left and right lungs, relative PBF index in both pulmonary arteries, and reduced bolus transit time for both left and right axial arteries (from 1.34 ± 0.39 and 1.81 ± 0.43 s to 0.52 ± 0.17 and 0.89 ± 0.21 s in the left and right axial arteries, respectively). Similar changes were observed with 100% oxygen, but increases in visible vessel number and vessel diameter of the axial arteries were greater in the ventilated right lung during unilateral ventilation. These findings confirm that PBF increase at birth is not spatially related to lung aeration and that the increase in PBF to unventilated regions is unrelated to oxygenation, although oxygen can potentiate this increase.


Asunto(s)
Pulmón/fisiología , Oxígeno/metabolismo , Circulación Pulmonar , Ventilación Pulmonar , Animales , Animales Recién Nacidos , Femenino , Frecuencia Cardíaca , Pulmón/irrigación sanguínea , Embarazo , Arteria Pulmonar/fisiología , Intercambio Gaseoso Pulmonar , Conejos
9.
J Synchrotron Radiat ; 23(1): 324-30, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26698080

RESUMEN

This work utilized synchrotron imaging to achieve a regional assessment of the lung's response to imparted oscillations. The forced oscillation technique is increasingly being used in clinical and research settings for the measurement of lung function. During the forced oscillation technique, pressure oscillations are imparted to the lungs via the subjects' airway opening and the response is measured. This provides information about the mechanical properties of the airways and lung tissue. The quality of measurements is dependent upon the input signal penetrating uniformly throughout the lung. However, the penetration of these signals is not well understood. The development and use of a novel image-processing technique in conjunction with synchrotron-based imaging was able to regionally assess the lungs' response to input pressure oscillation signals in anaesthetized mice. The imaging-based technique was able to quantify both the power and distribution of lung tissue oscillations during forced oscillations of the lungs. It was observed that under forced oscillations the apices had limited lung tissue expansion relative to the base. This technique could be used to optimize input signals used for the forced oscillation technique or potentially as a diagnostic tool itself.


Asunto(s)
Pulmón/metabolismo , Reología/métodos , Rayos X , Animales , Pulmón/diagnóstico por imagen , Masculino , Ratones , Ratones Endogámicos BALB C , Radiografía
10.
Pediatr Res ; 80(1): 85-91, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26991259

RESUMEN

BACKGROUND: A sustained inflation (SI) facilitates lung aeration, but the most effective pressure and duration are unknown. We investigated the effect of gestational age (GA) and airway liquid volume on the required inflation pressure and SI duration. METHODS: Rabbit kittens were delivered at 27, 29, and 30 d gestation, intubated and airway liquid was aspirated. Either no liquid (control) or 30 ml/kg of liquid was returned to the airways. Lung gas volumes were measured by plethysmography and phase-contrast X-ray-imaging. Starting at 22 cmH2O, airway pressure was increased until airflow commenced and pressure was then held constant. The SI was truncated when 20 ml/kg air had entered the lung and ventilation continued with intermittent positive pressure ventilation (iPPV). RESULTS: Higher SI pressures and longer durations were required in 27-d kittens compared to 30-d kittens. During iPPV, 27-d kittens needed higher pressures and had lower functional residual capacity (FRC) compared to 30-d kittens. Adding lung liquid increased SI duration, reduced FRC, and increased resistance and pressures during iPPV in 29- and 30-d kittens. CONCLUSION: Immature kittens required higher starting pressures and longer SI durations to achieve a set inflation volume. Larger airway liquid volumes adversely affected lung function during iPPV in older but not young kittens.


Asunto(s)
Capacidad Residual Funcional , Pulmón/fisiopatología , Respiración con Presión Positiva/métodos , Volumen de Ventilación Pulmonar , Animales , Animales Recién Nacidos , Peso al Nacer , Femenino , Edad Gestacional , Pletismografía , Embarazo , Preñez , Presión , Conejos , Pruebas de Función Respiratoria , Factores de Tiempo
11.
J Synchrotron Radiat ; 22(4): 1049-55, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26134810

RESUMEN

The high flux and coherence produced at long synchrotron beamlines makes them well suited to performing phase-contrast X-ray imaging of the airways and lungs of live small animals. Here, findings of the first live-animal imaging on the Imaging and Medical Beamline (IMBL) at the Australian Synchrotron are reported, demonstrating the feasibility of performing dynamic lung motion measurement and high-resolution micro-tomography. Live anaesthetized mice were imaged using 30 keV monochromatic X-rays at a range of sample-to-detector propagation distances. A frame rate of 100 frames s(-1) allowed lung motion to be determined using X-ray velocimetry. A separate group of humanely killed mice and rats were imaged by computed tomography at high resolution. Images were reconstructed and rendered to demonstrate the capacity for detailed, user-directed display of relevant respiratory anatomy. The ability to perform X-ray velocimetry on live mice at the IMBL was successfully demonstrated. High-quality renderings of the head and lungs visualized both large structures and fine details of the nasal and respiratory anatomy. The effect of sample-to-detector propagation distance on contrast and resolution was also investigated, demonstrating that soft tissue contrast increases, and resolution decreases, with increasing propagation distance. This new capability to perform live-animal imaging and high-resolution micro-tomography at the IMBL enhances the capability for investigation of respiratory diseases and the acceleration of treatment development in Australia.


Asunto(s)
Pulmón/diagnóstico por imagen , Pulmón/fisiología , Animales , Australia , Masculino , Ratones , Ratones Endogámicos C57BL , Microtomografía por Rayos X
12.
J Synchrotron Radiat ; 21(Pt 2): 430-45, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24562566

RESUMEN

Propagation-based phase-contrast X-ray imaging (PB-PCXI) using synchrotron radiation has achieved high-resolution imaging of the lungs of small animals both in real time and in vivo. Current studies are applying such imaging techniques to lung disease models to aid in diagnosis and treatment development. At the Australian Synchrotron, the Imaging and Medical beamline (IMBL) is well equipped for PB-PCXI, combining high flux and coherence with a beam size sufficient to image large animals, such as sheep, due to a wiggler source and source-to-sample distances of over 137 m. This study aimed to measure the capabilities of PB-PCXI on IMBL for imaging small animal lungs to study lung disease. The feasibility of combining this technique with computed tomography for three-dimensional imaging and X-ray velocimetry for studies of airflow and non-invasive lung function testing was also investigated. Detailed analysis of the role of the effective source size and sample-to-detector distance on lung image contrast was undertaken as well as phase retrieval for sample volume analysis. Results showed that PB-PCXI of lung phantoms and mouse lungs produced high-contrast images, with successful computed tomography and velocimetry also being carried out, suggesting that live animal lung imaging will also be feasible at the IMBL.


Asunto(s)
Pulmón/diagnóstico por imagen , Sincrotrones , Aire , Algoritmos , Animales , Estudios de Factibilidad , Vidrio , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Ratones , Microesferas , Fantasmas de Imagen , Reología/métodos , Sefarosa , Tomografía Computarizada por Rayos X/métodos
13.
J Synchrotron Radiat ; 21(Pt 4): 768-73, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24971973

RESUMEN

To assess potential therapies for respiratory diseases in which mucociliary transit (MCT) is impaired, such as cystic fibrosis and primary ciliary dyskinesia, a novel and non-invasive MCT quantification method has been developed in which the transit rate and behaviour of individual micrometre-sized deposited particles are measured in live mice using synchrotron phase-contrast X-ray imaging. Particle clearance by MCT is known to be a two-phase process that occurs over a period of minutes to days. Previous studies have assessed MCT in the fast-clearance phase, ∼20 min after marker particle dosing. The aim of this study was to non-invasively image changes in particle presence and MCT during the slow-clearance phase, and simultaneously determine whether repeat synchrotron X-ray imaging of mice was feasible over periods of 3, 9 and 25 h. All mice tolerated the repeat imaging procedure with no adverse effects. Quantitative image analysis revealed that the particle MCT rate and the number of particles present in the airway both decreased with time. This study successfully demonstrated for the first time that longitudinal synchrotron X-ray imaging studies are possible in live small animals, provided appropriate animal handling techniques are used and care is taken to reduce the delivered radiation dose.


Asunto(s)
Microesferas , Depuración Mucociliar/fisiología , Mucosa Respiratoria/diagnóstico por imagen , Mucosa Respiratoria/fisiología , Sincrotrones , Tomografía Computarizada por Rayos X/métodos , Animales , Femenino , Ratones , Ratones Endogámicos C57BL , Tamaño de la Partícula , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Pediatr Res ; 73(6): 734-41, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23478642

RESUMEN

BACKGROUND: We investigated the effects of positive end-expiratory pressure (PEEP) and tidal volume (VT) on lung aeration, pulmonary mechanics, and the distribution of ventilation immediately after birth using a preterm rabbit model. METHODS: Sixty preterm rabbits (27 d) received volume-targeted positive pressure ventilation from birth, with one of the 12 combinations of PEEP (0, 5, 8, or 10 cm H2O) and VT (4, 8, or 12 ml/kg). Outcomes included functional residual capacity (FRC), peak inflating pressure (PIP), dynamic compliance (Cd), and distribution of ventilation. RESULTS: Increasing PEEP from 0 to 10 cm H2O increased FRC by 4 ml/kg, increased Cd by 0.2 ml/kg/cm H2O, and reduced PIP by 5 cm H2O. Increasing VT from 4 to 12 ml/kg increased FRC by 2 ml/kg, increased Cd by 0.3 ml/kg/cm H2O, and increased PIP by 4 cmH2O. No effect of VT on FRC occurred at 0 or 5 PEEP, and no effect of PEEP occurred at VT = 4 ml/kg. At 0 PEEP, increasing VT increased the proportion of gas entering the smaller apical regions, whereas at 10 PEEP, increasing VT increased the proportion of gas entering basal regions, from 47% to 63%. CONCLUSION: Both PEEP and VT have independent, additive effects on FRC, lung mechanics, and the distribution of ventilation during the immediate newborn period.


Asunto(s)
Pulmón/fisiopatología , Oxígeno/metabolismo , Respiración con Presión Positiva , Volumen de Ventilación Pulmonar , Capacidad Pulmonar Total , Animales , Animales Recién Nacidos , Conejos
15.
Pediatr Res ; 73(4 Pt 1): 443-9, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23269118

RESUMEN

BACKGROUND: Recent phase-contrast X-ray imaging studies suggest that inspiration primarily drives lung aeration and airway liquid clearance at birth, which questions the role of adrenaline-induced activation of epithelial sodium channels (ENaCs). We hypothesized that pressures generated by inspiration have a greater role in airway liquid clearance than do ENaCs after birth. METHODS: Rabbit pups (30 d of gestation) were delivered and sedated, and 0.1 ml of saline (S) or amiloride (Am; an ENaC inhibitor) was instilled into the lungs before mechanical ventilation. Two other groups (30 d of gestation) were treated similarly but were also given adrenaline (S/Ad and Am/Ad) before mechanical ventilation. RESULTS: Amiloride and adrenaline did not affect functional residual capacity (FRC) recruitment (P > 0.05). Amiloride increased the rate of FRC loss between inflations (Am: -5.2 ± 0.6 ml/kg/s), whereas adrenaline reduced the rate of FRC loss (S/Ad: -1.9 ± 0.3 ml/kg/s) as compared with saline-treated controls (S: -3.5 ± -0.6 ml/kg/s; P < 0.05). CONCLUSION: These data indicate that inspiration is a major determinant of airway liquid clearance and FRC development during positive pressure ventilation. Although ENaC inhibition and adrenaline administration had no detectable effect on FRC development, ENaC may help to prevent liquid from re-entering the airways during expiration.


Asunto(s)
Canales Epiteliales de Sodio/metabolismo , Inhalación , Pulmón/metabolismo , Depuración Mucociliar , Respiración Artificial , Mucosa Respiratoria/metabolismo , Sodio/metabolismo , Amilorida/administración & dosificación , Animales , Animales Recién Nacidos , Epinefrina/administración & dosificación , Bloqueadores del Canal de Sodio Epitelial/administración & dosificación , Canales Epiteliales de Sodio/efectos de los fármacos , Capacidad Residual Funcional , Edad Gestacional , Presión Hidrostática , Pulmón/diagnóstico por imagen , Pulmón/efectos de los fármacos , Mediciones del Volumen Pulmonar , Pletismografía , Conejos , Radiografía , Mucosa Respiratoria/efectos de los fármacos , Cloruro de Sodio/administración & dosificación , Factores de Tiempo
16.
Front Med Technol ; 5: 1148310, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37440838

RESUMEN

Introduction: X-ray Velocimetry (XV) ventilation analysis is a 4-dimensional imaging-based method for quantifying regional ventilation, aiding in the assessment of lung function. We examined the performance characteristics of XV ventilation analysis by examining correlation to spirometry and measurement repeatability. Methods: XV analysis was assessed in 27 patients receiving thoracic radiotherapy for non-lung cancer malignancies. Measurements were obtained pre-treatment and at 4 and 12-months post-treatment. XV metrics such as ventilation defect percent (VDP) and regional ventilation heterogeneity (VH) were compared to spirometry at each time point, using correlation analysis. Repeatability was assessed between multiple runs of the analysis algorithm, as well as between multiple breaths in the same patient. Change in VH and VDP in a case series over 12 months was used to determine effect size and estimate sample sizes for future studies. Results: VDP and VH were found to significantly correlate with FEV1 and FEV1/FVC (range: -0.36 to -0.57; p < 0.05). Repeatability tests demonstrated that VDP and VH had less than 2% variability within runs and less than 8% change in metrics between breaths. Three cases were used to illustrate the advantage of XV over spirometry, where XV indicated a change in lung function that was either undetectable or delayed in detection by spirometry. Case A demonstrated an improvement in XV metrics over time despite stable spirometric values. Case B demonstrated a decline in XV metrics as early as 4-months, although spirometric values did not change until 12-months. Case C demonstrated a decline in XV metrics at 12 months post-treatment while spirometric values remained normal throughout the study. Based on the effect sizes in each case, sample sizes ranging from 10 to 38 patients would provide 90% power for future studies aiming to detect similar changes. Conclusions: The performance and safety of XV analysis make it ideal for both clinical and research applications across most lung indications. Our results support continued research and provide a basis for powering future studies using XV as an endpoint to examine lung health and determine therapeutic efficacy.

17.
Front Med (Lausanne) ; 10: 1160292, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37261124

RESUMEN

Dynamic heterogeneity in lung ventilation is an important measure of pulmonary function and may be characteristic of early pulmonary disease. While standard indices like spirometry, body plethysmography, and blood gases have been utilized to assess lung function, they do not provide adequate information on regional ventilatory distribution nor function assessments of ventilation during the respiratory cycle. Emerging technologies such as xenon CT, volumetric CT, functional MRI and X-ray velocimetry can assess regional ventilation using non-invasive radiographic methods that may complement current methods of assessing lung function. As a supplement to current modalities of pulmonary function assessment, functional lung imaging has the potential to identify respiratory disease phenotypes with distinct natural histories. Moreover, these novel technologies may offer an optimal strategy to evaluate the effectiveness of novel therapies and therapies targeting localized small airways disease in preclinical and clinical research. In this review, we aim to discuss the features of functional lung imaging, as well as its potential application and limitations to adoption in research.

18.
J Synchrotron Radiat ; 19(Pt 6): 1050-5, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23093769

RESUMEN

X-ray velocimetry offers a non-invasive method by which blood flow, blood velocity and wall shear stress can be measured in arteries prone to atherosclerosis. Analytical tools for measuring haemodynamics in artificial arteries have previously been developed and here the first quantification of haemodynamics using X-ray velocimetry in a living mammalian artery under physiologically relevant conditions is demonstrated. Whole blood seeded with a clinically used ultrasound contrast agent was pumped with a steady flow through live carotid arterial tissue from a rat, which was kept alive in a physiological salt solution. Pharmacological agents were then used to produce vascular relaxation. Velocity measurements were acquired with a spatial resolution of 14 µm × 14 µm and at a rate of 5000 acquisitions per second. Subtle velocity changes that occur are readily measurable, demonstrating the ability of X-ray velocimetry to sensitively and accurately measure haemodynamics ex vivo. Future applications and possible limitations of the technique are discussed, which allows for detailed living tissue investigations to be carried out for various disease models, including atherosclerosis and diabetic vasculopathy.


Asunto(s)
Arterias Carótidas/fisiología , Humanos , Técnicas In Vitro , Rayos X
19.
Pediatr Res ; 70(1): 50-5, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21451432

RESUMEN

Surfactant deficiency is a major cause of respiratory failure in newborns. We have investigated the roles of surfactant and positive end-expiratory pressure (PEEP) in the development of a functional residual capacity (FRC) and the distribution of ventilation at birth. Preterm rabbit pups (28 d GA) were delivered and received either saline or surfactant and then ventilated with (3PEEP) or without (0PEEP) 3 cm H2O PEEP (groups: saline/0PEEP, surfactant/0PEEP, saline/3PEEP, surfactant/3PEEP). Lung gas volumes were measured using plethysmography, and the uniformity of ventilation was analyzed using phase contrast (PC) x-ray imaging. Surfactant/0PEEP pups had greater FRCs and the lungs were more uniformly ventilated than saline/0PEEP pups; FRC at inflation 19-21 was 2.46 ± 0.52 mL/kg versus 0.91 ± 0.95 mL/kg (p < 0.05). Saline/3PEEP pups developed an FRC of 7.54 ± 1.68 mL/kg at inflation 19-21 (p < 0.05), but the distribution of ventilation was initially nonuniform. Surfactant/3PEEP pups had an FRC of 8.50 ± 0.80 mL/kg (at inflation 19-21), and the distribution of ventilation was more uniform than with saline/3PEEP (p < 0.05). In ventilated preterm newborn rabbits, PEEP has a greater effect on FRC than surfactant, although the two are additive. Surfactant, administered at birth, markedly improved the uniformity of ventilation irrespective of whether PEEP was applied.


Asunto(s)
Productos Biológicos/farmacología , Pulmón/efectos de los fármacos , Fosfolípidos/farmacología , Respiración con Presión Positiva , Nacimiento Prematuro , Surfactantes Pulmonares/farmacología , Ventilación Pulmonar/efectos de los fármacos , Animales , Animales Recién Nacidos , Capacidad Residual Funcional/efectos de los fármacos , Edad Gestacional , Pulmón/diagnóstico por imagen , Rendimiento Pulmonar/efectos de los fármacos , Pletismografía , Conejos , Radiografía , Mecánica Respiratoria/efectos de los fármacos
20.
J Synchrotron Radiat ; 17(5): 624-30, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20724784

RESUMEN

A high-repetition-rate mechanical shutter with asynchronous control and sub-millisecond operation has been developed and tested for specialist X-ray systems in the field of medical diagnostics and radiation therapy. Capacitor-coupled linear voice coil actuators are utilized to achieve opening and closing speeds as fast as 700 micros for an aperture height of 4 mm. The design allows for asynchronous control, permitting slave operation of the shutter, a feature that is distinctly suitable for a number of applications including particle image velocimetry, where high-frame-rate operation must be accurately synchronized and triggered by the image acquisition sequence of the detector or timing device. The design and construction of the shutter also makes it ideal, with simple and limited modifications, for applications requiring larger apertures, in particular wide beams as found in many synchrotron beamlines.


Asunto(s)
Sincrotrones/instrumentación , Arquitectura y Construcción de Instituciones de Salud , Óptica y Fotónica , Reología , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA