Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 546
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 60(6)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38929496

RESUMEN

Background and Objectives: Determinants of long-term outcomes after surgery for native mitral valve endocarditis have not been thoroughly investigated. The aim of this study was to assess anatomical, disease, and surgical risk factors for long-term mortality and need of reintervention, in patients undergoing mitral valve surgery for active endocarditis. Materials and Methods: Patients who underwent surgery for active native mitral valve endocarditis at three academic centres, between 2000 and 2022, were analysed. The primary outcome was long-term survival. The secondary outcome was the freedom from mitral reoperation. Survival curves were constructed with Kaplan-Meier methodology. Multivariable Cox regression was used to identify demographic, anatomical, disease, and surgical factors associated with late mortality and reoperation. Results: 335 consecutive patients with active mitral endocarditis were analysed. Two hundred and one patients (70.5%) had infection confined to the valve cusp whereas 89 (25.6%) had invasive disease extended to the annulus and surrounding tissues. Preoperative neurological events occurred at the diagnosis in 52 cases. Streptococci were the most common causative organisms followed by Staphylococcus aureus, Coagulase-negative Staphylococcus, and Enterococcus. Valve repair was performed in 108 patients (32.2%). Survival at 5 and 10 years was 70.1% and 59.2%, respectively. Staphylococcus emerged as an independent predictor of late mortality, along with age, chronic obstructive pulmonary disease, and previous cardiac surgery. Survival was considerably reduced in patients with S. aureus compared with those without (log rank p < 0.001). The type of surgery (repair vs. replacement) did not emerge as a risk factor for late mortality and reoperation. Seventeen patients underwent mitral reoperation during the follow-up. The 5- and 10-year freedom from reoperation was 94.7% and 91.8%, respectively. Conclusions: Active mitral valve endocarditis remains a life-threatening disease with impaired survival. While lesion characteristics influenced surgical decision-making and intraoperative management, their impact on long-term survival and freedom from reintervention appears to be moderated by other factors such as infecting pathogens and patient comorbidities.


Asunto(s)
Válvula Mitral , Humanos , Femenino , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Anciano , Reoperación/estadística & datos numéricos , Factores de Riesgo , Resultado del Tratamiento , Estudios Retrospectivos , Endocarditis/cirugía , Endocarditis/mortalidad , Adulto , Modelos de Riesgos Proporcionales , Estimación de Kaplan-Meier
2.
J Cardiovasc Electrophysiol ; 34(3): 728-737, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36477909

RESUMEN

INTRODUCTION: Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. METHODS: A total of 441 leads (median: 159 months [135-197]; range: 120-487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. RESULTS: The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003-1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow-up of 31 ± 27 months, 21 patients (11%) died. No procedure-related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99-21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04-62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48-9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17-8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow-up. CONCLUSION: Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Remoción de Dispositivos/métodos , Electrodos Implantados , Estudios Retrospectivos , Resultado del Tratamiento
3.
J Vasc Surg ; 77(4): 1182-1191.e1, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36464015

RESUMEN

OBJECTIVE: In the present report, we have described the prevalence, risk factors, and clinical effects of coronary artery disease (CAD) for patients with asymptomatic bilateral carotid stenosis. METHODS: We conducted a single-center, retrospective cohort study of consecutive patients referred for bilateral carotid stenosis >70% (2014-2021). All the patients had undergone systematic coronary angiography. Depending on the anatomic and clinical characteristics, the patients had undergone combined carotid endarterectomy (CEA) plus coronary artery bypass grafting, coronary percutaneous intervention followed by CEA or carotid artery stenting (CAS), or staged bilateral CEA with cardiac best medical therapy. The cumulative 30-day stroke/myocardial infarction (MI) rate after cardiac and bilateral carotid interventions and long-term survival and freedom from cardiovascular mortality were assessed. RESULTS: A total of 167 patients with bilateral carotid stenosis >70% had undergone preoperative coronary angiography, identifying severe CAD in 108 patients (65.1%). Echocardiographic abnormalities (odds ratio [OR], 2.07; 95% confidence interval [CI], 1.03-5.78; P = .04) and prior coronary intervention (OR, 11.94; 95% CI, 2.99-63.81; P = .001) were significantly associated with severe CAD. CAD was treatable in 91 patients (84%) and untreatable in 17 (16%). The cumulative MI rate was 4.8%; 5.6% for the patients with severe CAD and 1.7% for those without severe CAD (P = .262). The cumulative stroke rate was 1.8%; 1.8% for those with severe CAD and 1.7% for those without severe CAD (P = 1.00). The overall stroke/MI rate was 6.6%; 8.3% for those with severe CAD and 3.3% for patients without severe CAD (P = .33). Patients with severe CAD deemed untreatable for coronary bypass or percutaneous intervention had a higher risk of perioperative stroke/MI (OR, 1.24; 95% CI, 1.00-2.83; P = .04). At 10 years, overall survival was 67.1% (95% CI, 57%-79%), and freedom from cardiovascular mortality was 78.5% (95% CI, 69%-89%). Patients with untreatable CAD maintained a higher risk of 10-year mortality (hazard ratio, 5.5; 95% CI, 1.6-19.9; P < .01). CONCLUSIONS: In the present study, the prevalence of CAD in patients with bilateral carotid stenosis was high, especially for those with abnormal echocardiographic findings. CAD was potentially treatable in 80% of patients, and staged or simultaneous CAD treatment was performed with an acceptable stroke/MI complication rate for these patients. The presence of untreatable CAD was associated with worsened early and long-term outcomes, questioning the benefit of carotid interventions for this subset of patients.


Asunto(s)
Estenosis Carotídea , Enfermedad de la Arteria Coronaria , Endarterectomía Carotidea , Humanos , Estenosis Carotídea/complicaciones , Estenosis Carotídea/epidemiología , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/terapia , Endarterectomía Carotidea/efectos adversos , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Stents/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
4.
Pacing Clin Electrophysiol ; 46(8): 960-968, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36951180

RESUMEN

BACKGROUND: Outcomes of transvenous lead extraction (TLE) are well reported in the general population, However, data on safety, efficacy of TLE in octogenarians with a long lead dwell time, using powered extraction tools are limited. The aim of this multicenter study was to evaluate the safety, effectiveness of TLE in octogenarians using the bidirectional rotational mechanical sheaths and mid-term outcome after TLE. METHODS: The study population comprised 83 patients (78.3% male; mean age 85 ± 3 years; [range 80-94 years]) with 181 target leads. All the leads (mean implant duration 112 ± 77 months [range 12-377]) were extracted exclusively using the Evolution RL sheaths (Cook Medical, Bloomington, IN, USA). RESULTS: The main indication for TLE was infection in 84.3% of cases. Complete procedural success rate, clinical success rate, per lead were 93.9% and 98.3%, respectively. Failure of lead extraction was seen in 1.7% of leads. The additional use of a snare was required in 8.4% of patients. Major complications occurred in one patient (1.2%). Thirty-day mortality after TLE was 6%. During a mean time follow-up of 22 ± 21 months, 24 patients (29%) died. No procedure-related mortality occurred. Predictors of mortality included ischemic cardiomyopathy (HR 4.35; 95% CI 1.87-10.13; p = .001), left ventricularejection fraction ≤35% (HR 7.89; 95% CI 3.20-19.48; p < .001), and TLE for systemic infection (HR 4.24; 95% CI 1.69-10.66; p = .002). CONCLUSIONS: At experienced centers bidirectional rotational mechanical sheaths combined with different mechanical tools and femoral approach allowreasonable success and safety in octogenarian with long lead dwell time. Patient's age should not influence the decision to extract or not the leads, although the 30-day and mid-term mortality are significant, especially in the present of specific comorbidities.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Anciano de 80 o más Años , Humanos , Masculino , Femenino , Desfibriladores Implantables/efectos adversos , Octogenarios , Resultado del Tratamiento , Comorbilidad , Remoción de Dispositivos/efectos adversos , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos
5.
Int J Mol Sci ; 24(3)2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36769254

RESUMEN

The covalent functionalization of synthetic peptides allows the modification of different biomaterials (metallic, polymeric, and ceramic), which are enriched with biologically active sequences to guide cell behavior. Recently, this strategy has also been applied to decellularized biological matrices. In this study, the covalent anchorage of a synthetic peptide (REDV) to a pericardial matrix decellularized via Schiff base is realized starting from concentrated peptide solutions (10-4 M and 10-3 M). The use of a labeled peptide demonstrated that as the concentration of the working solution increased, the surface density of the anchored peptide increased as well. These data are essential to pinpointing the concentration window in which the peptide promotes the desired cellular activity. The matrices were extensively characterized by Water Contact Angle (WCA) analysis, Differential Scanning Calorimetry (DSC) analysis, geometric feature evaluation, biomechanical tests, and preliminary in vitro bioassays.


Asunto(s)
Péptidos , Pericardio , Materiales Biocompatibles
6.
Pacing Clin Electrophysiol ; 45(1): 92-102, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34699079

RESUMEN

BACKGROUND: Recent studies have shown that Evolution RL bidirectional rotational mechanical sheath (Cook Medical, USA) is an effective and safe technique for transvenous lead extraction (TLE). We reported our experience with the bidirectional rotational mechanical tools using a multidisciplinary approach highlighting the value of a joint cardiac surgeon and electrophysiologist collaboration. METHODS: The study population comprised 84 patients (77% male; mean age 65 ± 18 years) undergoing TLE. After a multidisciplinary evaluation, a combined procedure was considered. RESULTS: The main indication for TLE was infection in 54 cases (64%). Overall, 152 leads were extracted with a mean implant duration of 94 ± 63 months (range 12-421). Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 91.6% (77/84), 97.6% (82/84), and 98.6% (150/152), respectively. Eighteen combined procedures were performed in 12 patients (14%), such as "hybrid approach" (n = 2) or TLE concomitant to: 1) transcatheter aspiration procedure for large vegetation (n = 8); 2) left ventricular assistance device implantation as bridge to cardiac transplantation (n = 1); 3) permanent pacing with epicardial leads (n = 6); 4) tricuspid valve replacement (n = 1). One major complication (1.2%) and 11 (13%) minor complications were encountered. No injury to the superior vena cava occurred and no procedure-related deaths were reported. During a mean time follow-up of 21 ± 18 months, 17 patients (20%) died. They were more often diabetics (p = .02), and they underwent TLE more often for infection (p = .004). CONCLUSIONS: Our results support the finding that excellent outcomes can be achieved in performing TLE of chronically implanted leads by using the Evolution RL bidirectional rotational mechanical sheath and a multidisciplinary team approach involving both electrophysiologist and cardiac surgeon as first line operators.


Asunto(s)
Cardiólogos , Remoción de Dispositivos/métodos , Electrodos Implantados , Relaciones Interprofesionales , Infecciones Relacionadas con Prótesis/terapia , Cirujanos , Anciano , Electrofisiología Cardíaca , Desfibriladores Implantables , Femenino , Humanos , Masculino , Marcapaso Artificial
7.
Artif Organs ; 46(12): 2486-2492, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35866429

RESUMEN

BACKGROUND: We investigated the synergistic effect of the new cone-bearing design of Jarvik 2000 (Jarvik Heart Inc., NY) together with a minimally-invasive approach to outcomes of LVAD patients. METHODS: We retrospectively reviewed all patients from 5 institutions involved in the Jarvik 2000 Italian Registry, from October 2008 to October 2016. Patients were divided into three groups according to pump design and implantation technique: pin-bearing design and conventional approach (Group 1); cone-bearing and conventional approach (Group 2); cone-bearing and minimally-invasive implantation (Group 3). RESULTS: A total of 150 adult patients with end-stage heart failure were enrolled: 26 subjects in Group 1, 74 in Group 2, and 50 in Group 3. Nineteen patients (73%) in Group 1, 51 (69%) in Group 2, and 36 (72%) in Group 3 were discharged. During follow-up, 22 patients underwent transplantation, while in 3 patients the LVAD was explanted. The overall 1-year survival was 58 ± 10%, 64 ± 6%, and 74% ± 7% in Groups 1, 2, and 3, respectively (p = 0.034). The competing-risks-adjusted cumulative incidence rate for adverse events was 42.1 [27-62.7] per 100 patient-years in Group 1, 35.4 [25.3-48.2] in Group 2, and 22.1 [12.4-36.4] in Group 3 (p = 0.046 for Group 1 vs. 3). CONCLUSIONS: The association of the modern cone-bearing configuration of Jarvik 2000 and minimally invasive surgery improved survival and minimized the risk for cardiovascular events, as a result of combining technology and technique.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Adulto , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Insuficiencia Cardíaca/cirugía , Sistema de Registros , Tecnología , Resultado del Tratamiento
8.
Aging Clin Exp Res ; 34(3): 643-652, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34448150

RESUMEN

BACKGROUND: Surgical aortic valve replacement (SAVR) is still the gold standard for treating aortic valve stenosis (AVS). Its effectiveness has been extensively examined in terms of perioperative mortality, but its impact on overall health has received much less attention. AIMS: To assess the physical performance, cognitive status, and health-related quality of life of elderly patients undergoing SAVR, in the short, medium and long term. METHODS: This single-center prospective study enrolled patients aged > 70 years who underwent isolated SAVR for severe AVS. Data were collected on each participant's clinical status, physical performance, cognitive status, mood, and health-related quality of life. This multidimensional geriatric assessment was performed before surgery (T0), and again at 45 days (T1), 3 months (T2), 6 months (T3), and 12 months (T4) post-surgery. Baseline (T0) and follow-up (T2-T4) data were compared separately for patients grouped by gender using paired t-tests. RESULTS: Data from a total of 35 patients were analyzed. Compared with the baseline (T0), nutritional status worsened at T1, then gradually improved through to T4. Physical performance, mood, and health-related quality of life improved significantly after surgery. Cognitive function showed no change through to T3, but then deteriorated at T4. CONCLUSIONS: Our results show that SAVR in patients over 70 years of age has a positive impact on nutrition, mood, and health-related quality of life. Cognitive function was not negatively affected in the short and medium term, although it deteriorated in the long term. SAVR also had a positive impact on the physical performance of our sample.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Cognición , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Rendimiento Físico Funcional , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Resultado del Tratamiento
9.
J Card Surg ; 37(12): 4053-4061, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34550618

RESUMEN

INTRODUCTION: Nowadays micro-invasive-procedures (off-pump, beating-heart) for mitral valve repair (MVRe) are abruptly expanding with the potential to be adopted as a valuable alternative to surgery. In the present manuscript, the authors review the available technologies intended to treat mitral regurgitation (MR) through transapical approach, including annuloplasty and chordal-repair options. ANNULOPLASTY: To date, Valcare Amend is the only transapical MV ring to have been implanted in patients. The device allows for stabilization of the annulus through a complete semirigid d-shaped ring. The first-in-human successful procedure was performed in 2016 by our Group and subsequent clinical experience included a total of 14 implanted patients. Currently, the technology is under clinical trial evaluation to validate the efficacy and safety profile of the device. CHORDAL REPAIR: Beating-heart chordal implantation via transapical approach is a current feasible, safe and reproducible option. Neochord DS1000 is the most widely used technology in the field, with a solid procedural experience and good results in well-selected patients. Its clinical use has been validated in Europe since 2012, while it is still under clinical investigation in the United States. Harpoon MVRe system is a novel technology, recently CE-mark approved for clinical use. DISCUSSION AND CONCLUSIONS: Transapical micro-invasive technologies are current viable therapies to treat MR in selected patients. Although there are still several limitations that preclude an extensive use of such procedures, their results are promising in well-selected patients. Embracing transcatheter MVRe therapies should guide the cardiac surgeon through the new revolution of micro-invasive MV tailored repair.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/métodos
10.
J Card Surg ; 37(5): 1413-1415, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35152492

RESUMEN

We report an unusual case of black discoloration of an aortic root aneurysm and aortic valve cusps due to homogentisic acid deposition in a patient suffering from alkaptonuria. The patient underwent a valve-sparing aortic root replacement after careful and objective evaluation of the valve cusps. Despite alkaptonuria is classically associated with aortic valve stenosis and replacement, in the present case, the affected valve cusps were suitable for repair. To our knowledge, this is the first reported case of aortic valve-sparing procedure performed in a patient with alkaptonuria.


Asunto(s)
Alcaptonuria , Aneurisma de la Aorta Torácica , Estenosis de la Válvula Aórtica , Alcaptonuria/complicaciones , Aorta , Aneurisma de la Aorta Torácica/complicaciones , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Humanos
11.
J Card Surg ; 37(1): 165-173, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34717007

RESUMEN

OBJECTIVE: To analyze Italian Cardiac Surgery experience during the pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) identifying risk factors for overall mortality according to coronavirus disease 2019 (COVID-19) status. METHODS: From February 20 to May 31, 2020, 1354 consecutive adult patients underwent cardiac surgery at 22 Italian Centers; 589 (43.5%), patients came from the red zone. Based on COVID-19 status, 1306 (96.5%) were negative to SARS-CoV-2 (COVID-N), and 48 (3.5%) were positive to SARS-CoV-2 (COVID-P); among the COVID-P 11 (22.9%) and 37 (77.1%) become positive, before and after surgery, respectively. Surgical procedures were as follows: 396 (29.2%) isolated coronary artery bypass grafting (CABG), 714 (52.7%) isolated non-CABG procedures, 207 (15.3%) two associate procedures, and three or more procedures in 37 (2.7%). Heart failure was significantly predominant in group COVID-N (10.4% vs. 2.5%, p = .01). RESULTS: Overall in-hospital mortality was 1.6% (22 cases), being significantly higher in COVID-P group (10 cases, 20.8% vs. 12, 0.9%, p < .001). Multivariable analysis identified COVID-P condition as a predictor of in-hospital mortality together with emergency status. In the COVID-P subgroup, the multivariable analysis identified increasing age and low oxygen saturation at admission as risk factors for in-hospital mortality. CONCLUSION: As expected, SARS-CoV-2 infection, either before or soon after cardiac surgery significantly increases in-hospital mortality. Moreover, among COVID-19-positive patients, older age and poor oxygenation upon admission seem to be associated with worse outcomes.


Asunto(s)
COVID-19 , SARS-CoV-2 , Adulto , Anciano , Puente de Arteria Coronaria , Humanos , Pronóstico
12.
Surg Technol Int ; 412022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35920336

RESUMEN

BACKGROUND: Transplantation in the management of end-stage organ failure in patients with Anderson- Fabry disease is still a matter of debate due to a lack of data regarding long-term outcomes and prognosis. OBSERVATIONS: Most of the cases in the literature did not receive enzyme-replacement therapy (ERT), or received it only years after transplantation. Based on our experience, we describe here the long-term results of heart transplant in combination with early ERT. CONCLUSIONS: Transplantation combined with lifelong ERT should be considered to offer patients a chance of good long-term outcomes and quality of life.

13.
Int J Mol Sci ; 23(5)2022 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-35269969

RESUMEN

Bladder cancer (BC) is among the most common malignancies in the world and a relevant cause of cancer mortality. BC is one of the most frequent causes for bladder removal through radical cystectomy, the gold-standard treatment for localized muscle-invasive and some cases of high-risk, non-muscle-invasive bladder cancer. In order to restore urinary functionality, an autologous intestinal segment has to be used to create a urinary diversion. However, several complications are associated with bowel-tract removal, affecting patients' quality of life. The present study project aims to develop a bio-engineered material to simplify this surgical procedure, avoiding related surgical complications and improving patients' quality of life. The main novelty of such a therapeutic approach is the decellularization of a porcine small intestinal submucosa (SIS) conduit to replace the autologous intestinal segment currently used as urinary diversion after radical cystectomy, while avoiding an immune rejection. Here, we performed a preliminary evaluation of this acellular product by developing a novel decellularization process based on an environmentally friendly, mild detergent, i.e., Tergitol, to replace the recently declared toxic Triton X-100. Treatment efficacy was evaluated through histology, DNA, hydroxyproline and elastin quantification, mechanical and insufflation tests, two-photon microscopy, FTIR analysis, and cytocompatibility tests. The optimized decellularization protocol is effective in removing cells, including DNA content, from the porcine SIS, while preserving the integrity of the extracellular matrix despite an increase in stiffness. An effective sterilization protocol was found, and cytocompatibility of treated SIS was demonstrated from day 1 to day 7, during which human fibroblasts were able to increase in number and strongly organize along tissue fibres. Taken together, this in vitro study suggests that SIS is a suitable candidate for use in urinary diversions in place of autologous intestinal segments, considering the optimal results of decellularization and cell proliferation. Further efforts should be undertaken in order to improve SIS conduit patency and impermeability to realize a future viable substitute.


Asunto(s)
Neoplasias de la Vejiga Urinaria , Animales , ADN , Humanos , Mucosa Intestinal , Intestino Delgado , Calidad de Vida , Porcinos , Ingeniería de Tejidos/métodos , Neoplasias de la Vejiga Urinaria/cirugía
14.
Medicina (Kaunas) ; 58(3)2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35334549

RESUMEN

The gold-standard therapy for the treatment of aortic arch pathologies is conventional open surgery. Recently, total endovascular aortic arch replacement with branched stent-grafts has been introduced into clinical practice with the aim of reducing invasiveness especially in selected high-risk patients. The aim of this review is to describe the two most commonly used branched devices for endovascular arch stent-grafting: Nexus (Endospan, Herzlia, Israle) and RelayBranch (Terumo Aortic, Glasgow, United Kingdom). Nexus is a CE-certified off-the-shelf, single branch, double stent graft system. It consists of two different components: a main module for the aortic arch and the descending aorta with a side-branch for the brachiocephalic artery (BCA), and a curved module for the ascending aorta that lands into the sino-tubular junction and connects to the main module through a side-facing self-protecting sleeve. Nexus may be used in urgent-emergency cases and also in patients with only one suitable supra-aortic target vessel but, on the other hand, it makes cerebral blood flow dependent on one source vessel only. The RelayBranch Thoracic Stent-Graft System is a custom made, double branched endograft with a wide window on its superior portion to accommodate two inner tunnels for BCA and left common carotid artery connection; bilateral cervical accesses are generally used to advance guidewires for catheterization of the inner tunnels in a retrograde fashion. RelayBranch can be customized on every patient's specific anatomy and provides a double blood source for the brain, but it cannot be used in urgent-emergency conditions. Therefore, in order to optimize outcomes, the choice of the most appropriate device should be made considering pros and cons of each system and patient's anatomy by an experienced aortic team. In conclusion, total endovascular aortic arch exclusion is a promising reality in selected high-risk patients.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Humanos
15.
J Cardiovasc Electrophysiol ; 32(6): 1778-1781, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33825266

RESUMEN

AngioVac system (AngioDynamics) has already proved to be a useful tool in the treatment of thrombotic and endocarditic formations concerning the venous district. Herein, the AngioVac aspiration system combined with the bidirectional rotational Evolution mechanical sheath lead extraction was used for an effective and safety cardiac-device-related-infective-endocarditis removal in a grown-up congenital heart disease patient through a totally peripheral approach.


Asunto(s)
Desfibriladores Implantables , Endocarditis , Trombosis , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Humanos
16.
Catheter Cardiovasc Interv ; 97(4): 714-722, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33048438

RESUMEN

BACKGROUND: Redo surgical mitral valve replacement (SMVR) is the current standard of care for patients with failed bioprosthetic mitral valve (MV). Transcatheter mitral valve-in-valve replacement (TMViV) is arising as an alternative to SMVR in high risk patients. We sought to evaluate procedural safety, early and mid-term outcomes of patients who underwent transseptal TMViV (TS-TMViV), transapical TMViV (TA-TMViV), or redo-SMVR. METHODS: We identified patients with failed bioprosthetic MV who underwent TS-TMViV, TA-TMViV, or SMVR at four Italian Centers. Clinical and echocardiographic data were codified according to Mitral Valve Academic Research Consortium definition (MVARC), except for significant valve stenosis. RESULTS: Between December 2012 and September 27, 2019 patients underwent TS-TMViV, 22 TA-TMViV, and 29 redo-SMVR. TS-TMViV and TA-TMViV patients presented higher mean age and surgical risk scores compared with SMVR group (77.8 ± 12 years, 77.3 ± 7.3 years, 67.8 ± 9.4 years, p < .001; STS PROM 8.5 ± 7.2; 8.9 ± 4.7; 3.6 ± 2.6, p < .001). TS-TMViV procedure was associated with shorter intensive care unit time and total length of stay (LOS) compared with TA-TMViV and SMVR group. There were no differences in MVARC procedural success at 30-days (74.1, 72.7, and 51.7%, p = .15) and one-year all-cause mortality between groups (14.8, 18.2, and 17.2%, p = 1.0). MV mean gradient was similar between TS-TMViV, TA-TMViV, and SMVR groups at 30 days and 12 months. CONCLUSIONS: For the selected patients, TS-TMViV and TA-TMViV are to be considered a valid alternative to redo-SMVR with comparable 1-year survival. TS-TMViV is the less invasive strategy and has the advantage of shortening the LOS compared with TA-TMViV.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento
17.
BMC Med Res Methodol ; 21(1): 256, 2021 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-34809559

RESUMEN

BACKGROUND: Propensity score matching is a statistical method that is often used to make inferences on the treatment effects in observational studies. In recent years, there has been widespread use of the technique in the cardiothoracic surgery literature to evaluate to potential benefits of new surgical therapies or procedures. However, the small sample size and the strong dependence of the treatment assignment on the baseline covariates that often characterize these studies make such an evaluation challenging from a statistical point of view. In such settings, the use of propensity score matching in combination with oversampling and replacement may provide a solution to these issues by increasing the initial sample size of the study and thus improving the statistical power that is needed to detect the effect of interest. In this study, we review the use of propensity score matching in combination with oversampling and replacement in small sample size settings. METHODS: We performed a series of Monte Carlo simulations to evaluate how the sample size, the proportion of treated, and the assignment mechanism affect the performances of the proposed approaches. We assessed the performances with overall balance, relative bias, root mean squared error and nominal coverage. Moreover, we illustrate the methods using a real case study from the cardiac surgery literature. RESULTS: Matching without replacement produced estimates with lower bias and better nominal coverage than matching with replacement when 1:1 matching was considered. In contrast to that, matching with replacement showed better balance, relative bias, and root mean squared error than matching without replacement for increasing levels of oversampling. The best nominal coverage was obtained by using the estimator that accounts for uncertainty in the matching procedure on sets of units obtained after matching with replacement. CONCLUSIONS: The use of replacement provides the most reliable treatment effect estimates and that no more than 1 or 2 units from the control group should be matched to each treated observation. Moreover, the variance estimator that accounts for the uncertainty in the matching procedure should be used to estimate the treatment effect.


Asunto(s)
Puntaje de Propensión , Sesgo , Humanos , Método de Montecarlo , Tamaño de la Muestra
18.
Pacing Clin Electrophysiol ; 44(3): 557-558, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33404090

RESUMEN

Bidirectional rotational mechanical sheath is an effective and safe technique for transvenous lead extraction of chronically implanted leads. However, data about powered mechanical sheath through jugular vein are lacking. Our report demonstrated that bidirectional rotational mechanical sheath represents an effective and safe approach for removal of chronically implanted jugular leads.


Asunto(s)
Cardiomiopatía Hipertrófica/terapia , Desfibriladores Implantables , Remoción de Dispositivos , Electrodos Implantados , Venas Yugulares , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Tracción
19.
Ann Vasc Surg ; 73: 529-531, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33503499

RESUMEN

Kommerell diverticulum can be associated to several types of vascular rings, including double aortic arch. Surgical indications for vascular rings and Kommerell diverticulum include bulging symptoms onto trachea and esophagus too. Moreover, the aneurysmal enlargement over time can eventually cause acute aortic syndromes. Management of this pathology in adulthood is challenging and many techniques have been proposed, notably hybrid solutions. Herein, we report the case of a patient, who underwent redo surgery with frozen elephant trunk technique, caused by persisting symptoms after a previous operation of vascular ring interruption.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular , Divertículo/cirugía , Procedimientos Endovasculares , Reoperación , Anillo Vascular/cirugía , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Divertículo/diagnóstico por imagen , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Persona de Mediana Edad , Resultado del Tratamiento , Anillo Vascular/diagnóstico por imagen
20.
Artif Organs ; 45(3): 236-243, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32860268

RESUMEN

Continuous flow left ventricular assist devices (LVADs) have become a valuable therapy for end-stage heart failure. In vitro research highlighted a role of outflow cannula position on the pattern of blood flow in the aorta. However, the clinical effects of the alterations of flow remain unclear. We investigate short- and long-term outcomes of patients implanted with Jarvik 2000 LVAD, according to the ascending (Group 1) versus descending (Group 2) outflow graft connection to the aorta in a multicenter study. From May 2008 to October 2014, 140 consecutive end-stage heart failure patients underwent Jarvik 2000 LVAD implantation in 17 Italian centers. According with a preliminary multivariate analysis, we selected the 90 patients implanted in the four high-volume centers to avoid bias (Group 1 n = 39, Group 2 n = 51). Among the groups, no differences were recorded in the hospital mortality and the main complications occurring after LVAD implantation were similar. In multivariable analysis, the ascending aorta outflow cannula position and higher creatinine at discharge were significant predictors for long-term survival. Postimplant hemolysis was more pronounced in descending aorta outflow graft anastomosis. Outflow graft anastomosis to the ascending aorta is associated with better long-term survival, independent of age and perfusion techniques, reflecting the previous in vitro results.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis/efectos adversos , Anciano , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Aorta/fisiopatología , Aorta/cirugía , Creatinina/sangre , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Hemodinámica/fisiología , Hemólisis/fisiología , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA