Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(17)2022 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-36080972

RESUMEN

A novel and low-cost framework for food traceability, composed by commercial and proprietary sensing devices, for the remote monitoring of air, water, soil parameters and herbicide contamination during the farming process, has been developed and verified in real crop environments. It offers an integrated approach to food traceability with embedded systems supervision, approaching the problem to testify the quality of the food product. Moreover, it fills the gap of missing low-cost systems for monitoring cropping environments and pesticides contamination, satisfying the wide interest of regulatory agencies and final customers for a sustainable farming. The novelty of the proposed monitoring framework lies in the realization and the adoption of a fully automated prototype for in situ glyphosate detection. This device consists of a custom-made and automated fluidic system which, leveraging on the Molecularly Imprinted Polymer (MIP) sensing technology, permits to detect unwanted glyphosate contamination. The custom electronic mainboard, called ElectroSense, exhibits both the potentiostatic read-out of the sensor and the fluidic control to accomplish continuous unattended measurements. The complementary monitored parameters from commercial sensing devices are: temperature, relative humidity, atmospheric pressure, volumetric water content, electrical conductivity of the soil, pH of the irrigation water, total Volatile Organic Compounds (VOCs) and equivalent CO2. The framework has been validated during the olive farming activity in an Italian company, proving its efficacy for food traceability. Finally, the system has been adopted in a different crop field where pesticides treatments are practiced. This has been done in order to prove its capability to perform first level detection of pesticide treatments. Good correlation results between chemical sensors signals and pesticides treatments are highlighted.


Asunto(s)
Plaguicidas , Inocuidad de los Alimentos , Plaguicidas/análisis , Plaguicidas/toxicidad , Suelo/química , Tecnología , Agua
2.
Sensors (Basel) ; 21(5)2021 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-33800949

RESUMEN

The monitoring of some parameters, such as pressure loads, temperature, and glucose level in sweat on the plantar surface, is one of the most promising approaches for evaluating the health state of the diabetic foot and for preventing the onset of inflammatory events later degenerating in ulcerative lesions. This work presents the results of sensors microfabrication, experimental characterization and FEA-based thermal analysis of a 3D foot-insole model, aimed to advance in the development of a fully custom smart multisensory hardware-software monitoring platform for the diabetic foot. In this system, the simultaneous detection of temperature-, pressure- and sweat-based glucose level by means of full custom microfabricated sensors distributed on eight reading points of a smart insole will be possible, and the unit for data acquisition and wireless transmission will be fully integrated into the platform. Finite element analysis simulations, based on an accurate bioheat transfer model of the metabolic response of the foot tissue, demonstrated that subcutaneous inflamed lesions located up to the muscle layer, and ischemic damage located not below the reticular/fat layer, can be successfully detected. The microfabrication processes and preliminary results of functional characterization of flexible piezoelectric pressure sensors and glucose sensors are presented. Full custom pressure sensors generate an electric charge in the range 0-20 pC, proportional to the applied load in the range 0-4 N, with a figure of merit of 4.7 ± 1 GPa. The disposable glucose sensors exhibit a 0-6 mM (0-108 mg/dL) glucose concentration optimized linear response (for sweat-sensing), with a LOD of 3.27 µM (0.058 mg/dL) and a sensitivity of 21 µA/mM cm2 in the PBS solution. The technical prerequisites and experimental sensing performances were assessed, as preliminary step before future integration into a second prototype, based on a full custom smart insole with enhanced sensing functionalities.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Dispositivos Electrónicos Vestibles , Pie , Humanos , Zapatos , Sudor
3.
Biomed Chromatogr ; 32(4)2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29131420

RESUMEN

Cigarette smoking harms nearly every organ of the body and causes many diseases. The analysis of exhaled breath for exogenous and endogenous volatile organic compounds (VOCs) can provide fundamental information on active smoking and insight into the health damage that smoke is creating. Various exhaled VOCs have been reported as typical of smoking habit and recent tobacco consumption, but to date, no eligible biomarkers have been identified. Aiming to identify such potential biomarkers, in this pilot study we analyzed the chemical patterns of exhaled breath from 26 volunteers divided into groups of nonsmokers and subgroups of smokers sampled at different periods of withdrawal from smoking. Solid-phase microextraction technique and gas chromatography/mass spectrometry methods were applied. Many breath VOCs were identified and quantified in very low concentrations (ppbv range), but only a few (toluene, pyridine, pyrrole, benzene, 2-butanone, 2-pentanone and 1-methyldecyclamine) were found to be statistically significant variables by Mann-Whitney test. In our analysis, we did not consider the predictive power of individual VOCs, as well as the criterion of uniqueness for biomarkers suggests, but we used the patterns of the only statistically significant compounds. Probit prediction model based on statistical relevant VOCs-patterns showed that assessment of smoking status is heavily time dependent. In a two-class classifier model, it is possible to predict with high specificity and sensitivity if a subject is a smoker who respected 1 hour of abstinence from smoking (short-term exposure to tobacco) or a smoker (labelled "blank smoker") after a night out of smoking (long-term exposure to tobacco). On the other side, in our study "blank smokers" are more like non-smokers so that the two classes cannot be well distinguished and the corresponding prediction results showed a good sensitivity but low selectivity.


Asunto(s)
Biomarcadores/análisis , Pruebas Respiratorias/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Fumar/metabolismo , Compuestos Orgánicos Volátiles/análisis , Humanos , Fumadores/estadística & datos numéricos , Microextracción en Fase Sólida , Estadísticas no Paramétricas , Compuestos Orgánicos Volátiles/aislamiento & purificación , Compuestos Orgánicos Volátiles/metabolismo
4.
Micromachines (Basel) ; 14(3)2023 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-36984903

RESUMEN

Monitoring of ions in real-time directly in cell culture systems and in organ-on-a-chip platforms represents a significant investigation tool to understand ion regulation and distribution in the body and ions' involvement in biological mechanisms and specific pathologies. Innovative flexible sensors coupling electrochemical stripping analysis (square wave anodic stripping voltammetry, SWASV) with an ion selective membrane (ISM) were developed and integrated in Transwell™ cell culture systems to investigate the transport of zinc and copper ions across a human intestinal Caco-2 cell monolayer. The fabricated ion-selective sensors demonstrated good sensitivity (1 × 10-11 M ion concentration) and low detection limits, consistent with pathophysiological cellular concentration ranges. A non-invasive electrochemical impedance spectroscopy (EIS) analysis, in situ, across a selected spectrum of frequencies (10-105 Hz), and an equivalent circuit fitting were employed to obtain useful electrical parameters for cellular barrier integrity monitoring. Transepithelial electrical resistance (TEER) data and immunofluorescent images were used to validate the intestinal epithelial integrity and the permeability enhancer effect of ethylene glycol-bis(2-aminoethylether)-N,N,N',N'-tetraacetic acid (EGTA) treatment. The proposed devices represent a real prospective tool for monitoring cellular and molecular events and for studies on gut metabolism/permeability. They will enable a rapid integration of these sensors into gut-on-chip systems.

5.
Biology (Basel) ; 12(1)2022 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-36671729

RESUMEN

The dis(re)organization of the cytoskeletal actin in enterocytes mediates epithelial barrier dys(re)function, playing a key role in modulating epithelial monolayer's integrity and remodeling under transition from physiological to pathological states. Here, by fluorescence-based morphological and morphometric analyses, we detected differential responses of cytoskeletal actin in intestinal epithelial Caco-2 cell monolayers at two different stages of their spontaneous differentiation, i.e., undifferentiated cells at 7 days post-seeding (dps) and differentiated enterocyte-like cells at 21 dps, upon challenge in vitro with the inflammation-mimicking stimulus of phorbol-12-myristate-13-acetate (PMA). In addition, specific responses were found in the presence of the natural dipeptide carnosine detecting its potential counteraction against PMA-induced cytoskeletal alterations and remodeling in differentiated Caco-2 monolayers. In such an experimental context, by both immunocytochemistry and Western blot assays in Caco-2 monolayers, we identified the expression of the allograft inflammatory factor 1 (AIF-1) as protein functionally related to both inflammatory and cytoskeletal pathways. In 21 dps monolayers, particularly, we detected variations of its intracellular localization associated with the inflammatory stimulus and its mRNA/protein increase associated with the differentiated 21 dps enterocyte-like monolayer compared to the undifferentiated cells.

6.
Artículo en Inglés | MEDLINE | ID: mdl-34639537

RESUMEN

Environmental chemicals and contaminants coming from multiple external sources enter the human body, determining a potential risk for human health. Human biomonitoring (HBM), measuring the concentrations of biomarkers in human specimens, has become an emerging approach for assessing population-wide exposure to hazardous chemicals and health risk through large-scale studies in many countries. However, systematic mapping of HBM studies, including their characteristics, targeted hazardous pollutants, analytical techniques, and sample population (general population and occupationally exposed workers), has not been done so far. We conducted a systematic review of the literature related to airborne hazardous pollutants in biofluids to answer the following questions: Which main chemicals have been included in the literature, which bodily fluids have been used, and what are the main findings? Following PRISMA protocol, we summarized the publications published up to 4 February 2021 of studies based on two methods: gas-chromatography/mass spectrometry (GC/MS) and electronic noses (e-noses). We screened 2606 records and 117 publications were included in the analysis, the most based on GC/MS analysis. The selected HBM studies include measurements of biomarkers in different bodily fluids, such as blood, urine, breast milk, and human semen as well as exhaled air. The papers cover numerous airborne hazardous pollutants that we grouped in chemical classes; a lot of hazardous and noxious compounds, mainly persistent organic pollutants (POPs) and volatile organic compounds (VOCs), have been detected in biological fluids at alarming levels. The scenario that emerged from this survey demonstrates the importance of HBM in human exposure to hazardous pollutants and the need to use it as valid tool in health surveillance. This systematic review represents a starting point for researchers who focus on the world of pollutant biomonitoring in the human body and gives them important insights into how to improve the methods based on GC/MS. Moreover, it makes a first overview of the use of gas sensor array and e-noses in HBM studies.


Asunto(s)
Contaminantes Ambientales , Exposición Profesional , Compuestos Orgánicos Volátiles , Monitoreo Biológico , Monitoreo del Ambiente , Contaminantes Ambientales/análisis , Femenino , Cromatografía de Gases y Espectrometría de Masas , Humanos , Exposición Profesional/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA