Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Crit Care Med ; 52(3): e142-e151, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38193770

RESUMEN

OBJECTIVES: An association between physical inactivity and worse outcome during infectious disease has been reported. The effect of moderate exercise preconditioning on the immune response during an acute pneumonia in a murine model was evaluated. SETTING: Laboratory experiments. SUBJECTS: C57BL6/j male mice. INTERVENTIONS: Six-week-old C57BL/6J mice were divided in two groups: an exercise group and a control group. In the exercise group, a moderate, progressive, and standardized physical exercise was applied for 8 weeks. It consisted in a daily treadmill training lasting 60 minutes and with an intensity of 65% of the maximal theoretical oxygen uptake. Usual housing recommendation were applied in the control group during the same period. After 8 weeks, pneumonia was induced in both groups by intratracheal instillation of a fixed concentration of a Klebsiella pneumoniae (5 × 103 colony-forming unit) solution. MEASUREMENTS AND MAIN RESULTS: Mice preconditioned by physical exercise had a less sever onset of pneumonia as shown by a significant decrease of the Mouse Clinical Assessment Severity Score and had a significantly lower mortality compared with the control group (27% vs. 83%; p = 0.019). In the exercise group, we observed a significantly earlier but transient recruitment of inflammatory immune cells with a significant increase of neutrophils, CD4+ cells and interstitial macrophages counts compared with control group. Lung tumor necrosis factor-α, interleukin (IL)-1ß, IL-6, and IL-10 were significantly decreased at 48 hours after pneumonia induction in the exercise group compared with the control group. CONCLUSIONS: In our model, preconditioning by moderate physical exercise improves outcome by reducing the severity of acute pneumonia with an increased but transient activation of the innate immune response.


Asunto(s)
Neumonía , Ratones , Masculino , Humanos , Animales , Modelos Animales de Enfermedad , Ratones Endogámicos C57BL , Pulmón/patología , Factor de Necrosis Tumoral alfa
2.
Magn Reson Med ; 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38924176

RESUMEN

PURPOSE: To fully characterize the orientation dependence of magnetization transfer (MT) and inhomogeneous MT (ihMT) measures in the whole white matter (WM), for both single-fiber and crossing-fiber voxels. METHODS: A characterization method was developed using the fiber orientation obtained from diffusion MRI (dMRI) with diffusion tensor imaging (DTI) and constrained spherical deconvolution. This allowed for characterization of the orientation dependence of measures in all of WM, regardless of the number of fiber orientation in a voxel. Furthermore, the orientation dependence inside 31 different WM bundles was characterized to evaluate the homogeneity of the effect. Variation of the results within and between-subject was assessed from a 12-subject dataset. RESULTS: Previous results for single-fiber voxels were reproduced and a novel characterization was produced in voxels of crossing fibers, which seems to follow trends consistent with single-fiber results. Heterogeneity of the orientation dependence across bundles was observed, but homogeneity within similar bundles was also highlighted. Differences in behavior between MT and ihMT measures, as well as the ratio and saturation versions of these, were noted. CONCLUSION: Orientation dependence characterization was proven possible over the entirety of WM. The vast range of effects and subtleties of the orientation dependence on MT measures showed the need for, but also the challenges of, a correction method.

3.
Magn Reson Med ; 92(3): 1115-1127, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38730562

RESUMEN

PURPOSE: T1 mapping is a widely used quantitative MRI technique, but its tissue-specific values remain inconsistent across protocols, sites, and vendors. The ISMRM Reproducible Research and Quantitative MR study groups jointly launched a challenge to assess the reproducibility of a well-established inversion-recovery T1 mapping technique, using acquisition details from a seminal T1 mapping paper on a standardized phantom and in human brains. METHODS: The challenge used the acquisition protocol from Barral et al. (2010). Researchers collected T1 mapping data on the ISMRM/NIST phantom and/or in human brains. Data submission, pipeline development, and analysis were conducted using open-source platforms. Intersubmission and intrasubmission comparisons were performed. RESULTS: Eighteen submissions (39 phantom and 56 human datasets) on scanners by three MRI vendors were collected at 3 T (except one, at 0.35 T). The mean coefficient of variation was 6.1% for intersubmission phantom measurements, and 2.9% for intrasubmission measurements. For humans, the intersubmission/intrasubmission coefficient of variation was 5.9/3.2% in the genu and 16/6.9% in the cortex. An interactive dashboard for data visualization was also developed: https://rrsg2020.dashboards.neurolibre.org. CONCLUSION: The T1 intersubmission variability was twice as high as the intrasubmission variability in both phantoms and human brains, indicating that the acquisition details in the original paper were insufficient to reproduce a quantitative MRI protocol. This study reports the inherent uncertainty in T1 measures across independent research groups, bringing us one step closer to a practical clinical baseline of T1 variations in vivo.


Asunto(s)
Encéfalo , Colaboración de las Masas , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Fantasmas de Imagen , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador/métodos , Mapeo Encefálico/métodos , Masculino , Femenino , Adulto , Algoritmos
4.
J Pediatr ; 266: 113879, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38142044

RESUMEN

OBJECTIVE: To test feasibility and safety of administering sildenafil in neonates with neonatal encephalopathy (NE), developing brain injury despite therapeutic hypothermia (TH). STUDY DESIGN: We performed a randomized, double-blind, placebo-controlled phase Ib clinical trial between 2016 and 2019 in neonates with moderate or severe NE, displaying brain injury on day-2 magnetic resonance imaging (MRI) despite TH. Neonates were randomized (2:1) to 7-day sildenafil or placebo (2 mg/kg/dose enterally every 12 hours, 14 doses). Outcomes included feasibility and safety (primary outcomes), pharmacokinetics (secondary), and day-30 neuroimaging and 18-month neurodevelopment assessments (exploratory). RESULTS: Of the 24 enrolled neonates, 8 were randomized to sildenafil and 3 to placebo. A mild decrease in blood pressure was reported in 2 of the 8 neonates after initial dose, but not with subsequent doses. Sildenafil plasma steady-state concentration was rapidly reached, but decreased after TH discontinuation. Twelve percent of neonates (1/8) neonates died in the sildenafil group and 0% (0/3) in the placebo group. Among surviving neonates, partial recovery of injury, fewer cystic lesions, and less brain volume loss on day-30 magnetic resonance imaging were noted in 71% (5/7) of the sildenafil group and in 0% (0/3) of the placebo group. The rate of death or survival to 18 months with severe neurodevelopmental impairment was 57% (4/7) in the sildenafil group and 100% (3/3) in the placebo group. CONCLUSIONS: Sildenafil was safe and well-absorbed in neonates with NE treated with TH. Optimal dosing needs to be established. Evaluation of a larger number of neonates through subsequent phases II and III trials is required to establish efficacy. CLINICAL TRIAL REGISTRATION: ClinicalTrials.govNCT02812433.


Asunto(s)
Asfixia Neonatal , Lesiones Encefálicas , Hipotermia Inducida , Hipoxia-Isquemia Encefálica , Enfermedades del Recién Nacido , Recién Nacido , Humanos , Citrato de Sildenafil/efectos adversos , Asfixia/complicaciones , Estudios de Factibilidad , Asfixia Neonatal/terapia , Lesiones Encefálicas/complicaciones , Lesiones Encefálicas/tratamiento farmacológico , Enfermedades del Recién Nacido/terapia , Hipoxia-Isquemia Encefálica/terapia , Hipotermia Inducida/métodos , Método Doble Ciego
5.
J Mol Cell Cardiol ; 179: 47-59, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37003353

RESUMEN

Ca2+ transients (CaT) underlying cardiomyocyte (CM) contraction require efficient Ca2+ coupling between sarcolemmal Ca2+ channels and sarcoplasmic reticulum (SR) ryanodine receptor Ca2+ channels (RyR) for their generation; reduced coupling in disease contributes to diminished CaT and arrhythmogenic Ca2+ events. SR Ca2+ release also occurs via inositol 1,4,5-trisphosphate receptors (InsP3R) in CM. While this pathway contributes negligeably to Ca2+ handling in healthy CM, rodent studies support a role in altered Ca2+ dynamics and arrhythmogenic Ca2+ release involving InsP3R crosstalk with RyRs in disease. Whether this mechanism persists in larger mammals with lower T-tubular density and coupling of RyRs is not fully resolved. We have recently shown an arrhythmogenic action of InsP3-induced Ca2+ release (IICR) in end stage human heart failure (HF), often associated with underlying ischemic heart disease (IHD). How IICR contributes to early stages of disease is however not determined but highly relevant. To access this stage, we chose a porcine model of IHD, which shows substantial remodelling of the area adjacent to the infarct. In cells from this region, IICR preferentially augmented Ca2+ release from non-coupled RyR clusters that otherwise showed delayed activation during the CaT. IICR in turn synchronised Ca2+ release during the CaT but also induced arrhythmogenic delayed afterdepolarizations and action potentials. Nanoscale imaging identified co-clustering of InsP3Rs and RyRs, thereby allowing Ca2+-mediated channel crosstalk. Mathematical modelling supported and further delineated this mechanism of enhanced InsP3R-RyRs coupling in MI. Our findings highlight the role of InsP3R-RyR channel crosstalk in Ca2+ release and arrhythmia during post-MI remodelling.


Asunto(s)
Infarto del Miocardio , Isquemia Miocárdica , Animales , Arritmias Cardíacas/metabolismo , Calcio/metabolismo , Señalización del Calcio/fisiología , Mamíferos/metabolismo , Contracción Miocárdica , Infarto del Miocardio/metabolismo , Isquemia Miocárdica/metabolismo , Miocitos Cardíacos/metabolismo , Canal Liberador de Calcio Receptor de Rianodina/metabolismo , Retículo Sarcoplasmático/metabolismo , Porcinos
6.
Hum Brain Mapp ; 44(9): 3758-3780, 2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-37067096

RESUMEN

Assessing the consistency of quantitative MRI measurements is critical for inclusion in longitudinal studies and clinical trials. Intraclass coefficient correlation and coefficient of variation were used to evaluate the different consistency aspects of diffusion- and myelin-based MRI measures. Multi-shell diffusion and inhomogeneous magnetization transfer data sets were collected from 20 healthy adults at a high-frequency of five MRI sessions. The consistency was evaluated across whole bundles and the track-profile along the bundles. The impact of the fiber populations on the consistency was also evaluated using the number of fiber orientations map. For whole and profile bundles, moderate to high reliability of diffusion and myelin measures were observed. We report higher reliability of measures for multiple fiber populations than single. The overall portrait of the most consistent measurements and bundles drawn from a wide range of MRI techniques presented here will be particularly useful for identifying reliable biomarkers capable of detecting, monitoring and predicting white matter changes in clinical applications and has the potential to inform patient-specific treatment strategies.


Asunto(s)
Sustancia Blanca , Adulto , Humanos , Sustancia Blanca/diagnóstico por imagen , Vaina de Mielina , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética , Estudios Longitudinales , Encéfalo/diagnóstico por imagen
7.
Magn Reson Med ; 89(5): 1809-1824, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36511247

RESUMEN

PURPOSE: We investigated the correlation, reproducibility, and effect of white matter fiber orientation for three myelin-sensitive MRI techniques: magnetization transfer ratio (MTR), inhomogeneous magnetization transfer ratio (ihMTR), and gradient and spin echo-derived myelin water fraction (MWF). METHODS: We measured the three metrics in 17 white and three deep grey matter regions in 17 healthy adults at 3 T. RESULTS: We found a strong correlation between ihMTR and MTR (r = 0.70, p < 0.001) and ihMTR and MWF (r = 0.79, p < 0.001), and a weaker correlation between MTR and MWF (r = 0.54, p < 0.001). The dynamic range in white matter was greatest for MWF (2.0%-27.5%), followed by MTR (14.4%-23.2%) and then ihMTR (1.2%-5.4%). The average scan-rescan coefficient of variation for white matter regions was 0.6% MTR, 0.3% ihMTR, and 0.7% MWF in metric units; however, when adjusted by the dynamic range, these became 6.3%, 6.1% and 2.8%, respectively. All three metrics varied with fiber direction: MWF and ihMTR were lower in white matter fibers perpendicular to B0 by 6% and 1%, respectively, compared with those parallel, whereas MTR was lower by 0.5% at about 40°, with the highest values at 90°. However, separating the apparent orientation dependence by white matter region revealed large dissimilarities in the trends, suggesting that real differences in myelination between regions are confounding the apparent orientation dependence measured using this method. CONCLUSION: The strong correlation between ihMTR and MWF suggests that these techniques are measuring the same myelination; however, the larger dynamic range of MWF may provide more power to detect small differences in myelin.


Asunto(s)
Vaina de Mielina , Sustancia Blanca , Humanos , Adulto , Reproducibilidad de los Resultados , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sustancia Blanca/diagnóstico por imagen , Agua , Biomarcadores
8.
Neuroimage ; 264: 119750, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36379421

RESUMEN

The myelin concentration and the degree of myelination of nerve fibers can provide valuable information on the integrity of human brain tissue. Magnetic resonance imaging (MRI) of myelin-sensitive parameters can help to non-invasively evaluate demyelinating diseases such as multiple sclerosis (MS). Several different myelin-sensitive MRI methods have been proposed to determine measures of the degree of myelination, in particular the g-ratio. However, variability in underlying physical principles and different biological models influence measured myelin concentrations, and consequently g-ratio values. We therefore investigated similarities and differences between five different myelin-sensitive MRI measures and their effects on g-ratio mapping in the brains of both MS patients and healthy volunteers. We compared two different estimates of the myelin water fraction (MWF) as well as the inhomogeneous magnetization transfer ratio (ihMTR), magnetization transfer saturation (MTsat), and macromolecular tissue volume (MTV) in 13 patients with MS and 14 healthy controls. In combination with diffusion-weighted imaging, we derived g-ratio parameter maps for each of the five different myelin measures. The g-ratio values calculated from different myelin measures varied strongly, especially in MS lesions. While, compared to normal-appearing white matter, MTsat and one estimate of the MWF resulted in higher g-ratio values within lesions, ihMTR, MTV, and the second MWF estimate resulted in lower lesion g-ratio values. As myelin-sensitive measures provide rough estimates of myelin content rather than absolute myelin concentrations, resulting g-ratio values strongly depend on the utilized myelin measure and model used for g-ratio mapping. When comparing g-ratio values, it is, thus, important to utilize the same MRI methods and models or to consider methodological differences. Particular caution is necessary in pathological tissue such as MS lesions.


Asunto(s)
Esclerosis Múltiple , Sustancia Blanca , Humanos , Vaina de Mielina/patología , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología , Agua
9.
Hum Brain Mapp ; 43(11): 3545-3558, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35411995

RESUMEN

Brain injury and dysmaturation is common in fetuses and neonates with congenital heart disease (CHD) and is hypothesized to result in persistent myelination deficits. This study aimed to quantify and compare myelin content in vivo between youth born with CHD and healthy controls. Youth aged 16 to 24 years born with CHD and healthy age- and sex-matched controls underwent brain magnetic resonance imaging including multicomponent driven equilibrium single pulse observation of T1 and T2 (mcDESPOT). Average myelin water fraction (MWF) values for 33 white matter tracts, as well as a summary measure of average white matter MWF, the White Matter Myelination Index, were calculated and compared between groups. Tract-average MWF was lower throughout the corpus callosum and in many bilateral association tracts and left hemispheric projection tracts in youth with CHD (N = 44) as compared to controls (N = 45). The White Matter Myelination Index was also lower in the CHD group. As such, this study provides specific evidence of widespread myelination deficits in youth with CHD, likely representing a long-lasting consequence of early-life brain dysmaturation in this population. This deficient myelination may underlie the frequent neurodevelopmental impairments experienced by CHD survivors and could eventually serve as a biomarker of neuropsychological function.


Asunto(s)
Cardiopatías Congénitas , Sustancia Blanca , Adolescente , Encéfalo/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Recién Nacido , Imagen por Resonancia Magnética/métodos , Vaina de Mielina , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología
10.
Basic Res Cardiol ; 117(1): 60, 2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-36378362

RESUMEN

Dysregulated intracellular Ca2+ handling involving altered Ca2+ release from intracellular stores via RyR channels underlies both arrhythmias and reduced function in heart failure (HF). Mechanisms linking RyR dysregulation and disease are not fully established. Studies in animals support a role for InsP3 receptor Ca2+ channels (InsP3R) in pathological alterations in cardiomyocyte Ca2+ handling but whether these findings translate to the divergent physiology of human cardiomyocytes during heart failure is not determined. Using electrophysiological and Ca2+ recordings in human ventricular cardiomyocytes, we uncovered that Ca2+ release via InsP3Rs facilitated Ca2+ release from RyR and induced arrhythmogenic delayed after depolarisations and action potentials. InsP3R-RyR crosstalk was particularly increased in HF at RyR clusters isolated from the T-tubular network. Reduced SERCA activity in HF further facilitated the action of InsP3. Nanoscale imaging revealed co-localisation of InsP3Rs with RyRs in the dyad, which was increased in HF, providing a mechanism for augmented Ca2+ channel crosstalk. Notably, arrhythmogenic activity dependent on InsP3Rs was increased in tissue wedges from failing hearts perfused with AngII to promote InsP3 generation. These data indicate a central role for InsP3R-RyR Ca2+ signalling crosstalk in the pro-arrhythmic action of GPCR agonists elevated in HF and the potential for their therapeutic targeting.


Asunto(s)
Insuficiencia Cardíaca , Canal Liberador de Calcio Receptor de Rianodina , Humanos , Animales , Canal Liberador de Calcio Receptor de Rianodina/metabolismo , Calcio/metabolismo , Miocitos Cardíacos/metabolismo , Arritmias Cardíacas/metabolismo , Insuficiencia Cardíaca/metabolismo , Señalización del Calcio
11.
Magn Reson Med ; 88(2): 849-859, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35476875

RESUMEN

PURPOSE: Spinal cord gray-matter imaging is valuable for a number of applications, but remains challenging. The purpose of this work was to compare various MRI protocols at 1.5 T, 3 T, and 7 T for visualizing the gray matter. METHODS: In vivo data of the cervical spinal cord were collected from nine different imaging centers. Data processing consisted of automatically segmenting the spinal cord and its gray matter and co-registering back-to-back scans. We computed the SNR using two methods (SNR_single using a single scan and SNR_diff using the difference between back-to-back scans) and the white/gray matter contrast-to-noise ratio per unit time. Synthetic phantom data were generated to evaluate the metrics performance. Experienced radiologists qualitatively scored the images. We ran the same processing on an open-access multicenter data set of the spinal cord MRI (N = 267 participants). RESULTS: Qualitative assessments indicated comparable image quality for 3T and 7T scans. Spatial resolution was higher at higher field strength, and image quality at 1.5 T was found to be moderate to low. The proposed quantitative metrics were found to be robust to underlying changes to the SNR and contrast; however, the SNR_single method lacked accuracy when there were excessive partial-volume effects. CONCLUSION: We propose quality assessment criteria and metrics for gray-matter visualization and apply them to different protocols. The proposed criteria and metrics, the analyzed protocols, and our open-source code can serve as a benchmark for future optimization of spinal cord gray-matter imaging protocols.


Asunto(s)
Médula Cervical , Sustancia Blanca , Sustancia Gris/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Estudios Multicéntricos como Asunto , Médula Espinal/diagnóstico por imagen , Sustancia Blanca/diagnóstico por imagen
12.
Magn Reson Med ; 86(6): 3052-3066, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34268824

RESUMEN

PURPOSE: Accurately estimating the arterial input function for dynamic contrast-enhanced MRI is challenging. An arterial input function is typically determined from signal magnitude changes related to a contrast agent, often leading to underestimation of peak concentrations. Alternatively, signal phase recovers the accurate peak concentration for straight vessels but suffers from high noise. A recent method proposed to fit the signal in the complex plane by combining the advantages of the previous 2 methods. The purpose of this work is to refine this complex-based method to determine the venous output function (VOF), an arterial input function surrogate, from the superior sagittal sinus. METHODS: We propose a state-of-the-art complex-based method that includes direct compensation for blood inflow and signal phase correction accounting for the curvature of the superior sagittal sinus, generally assumed collinear with B0 . We compared the magnitude-, phase-, and complex-based VOF determination methods against various simulated biases as well as for 29 brain metastases patients. RESULTS: Angulation of the superior sagittal sinus relative to B0 varied widely within patients, and its effect on the signal phase caused an underestimation of peak concentrations of up to 65%. Correction significantly increased the VOF peak concentration for the phase- and complex-based VOFs in the cohort. The phase-based method recovered accurate peak concentrations but lacked precision in the tail of the VOF. Our complex-based VOF completely recovered the effect of inflow and resulted in a high-peak concentration with limited noise. CONCLUSION: The new complex-based method resulted in high-quality VOF robust against superior sagittal sinus curvature and variations in patient positioning.


Asunto(s)
Imagen por Resonancia Magnética , Seno Sagital Superior , Algoritmos , Encéfalo/diagnóstico por imagen , Medios de Contraste , Humanos , Seno Sagital Superior/diagnóstico por imagen
13.
NMR Biomed ; 34(9): e4567, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34076305

RESUMEN

The purpose of this study was to evaluate the use of a double delay alternating with nutation for tailored excitation (D-DANTE)-prepared sequence for banding-free isotropic high-resolution intracranial vessel wall imaging (IC-VWI) and to compare its performance with regular DANTE in terms of signal-to-noise ratio (SNR) as well as cerebrospinal fluid (CSF) and blood suppression efficiency. To this end, a D-DANTE-prepared 3D turbo spin echo sequence was implemented by interleaving two separate DANTE pulse trains with different RF phase-cycling schemes, but keeping all other DANTE parameters unchanged, including the total number of pulses and total preparation time. This achieved a reduction of the banding distance compared with regular DANTE enabling banding-free imaging up to higher resolutions. Bloch simulations assuming static vessel wall and flowing CSF spins were performed to compare DANTE and D-DANTE in terms of SNR and vessel wall/CSF contrast. Similar image quality measures were assessed from measurements on 13 healthy middle-aged volunteers. Both simulation and in vivo results showed that D-DANTE had only slightly lower vessel wall/CSF and vessel wall/blood contrast-to-noise ratio values compared with regular DANTE, which originated from a 10%-15% reduction in vessel wall SNR but not from reduced CSF or blood suppression efficiency. As anticipated, IC-VWI acquisitions showed that D-DANTE can successfully remove banding artifacts compared with regular DANTE with equal scan time or DANTE preparation length. Moreover, application was demonstrated in a patient with an intracranial aneurysm, indicating improved robustness to slow flow artifacts compared with clinically available 3D turbo spin echo scans. In conclusion, D-DANTE provides banding artifact-free IC-VWI up to higher isotropic resolutions compared with regular DANTE. This allows for a more flexible choice of DANTE preparation parameters in high-resolution IC-VWI protocols.


Asunto(s)
Algoritmos , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética , Líquido Cefalorraquídeo/metabolismo , Simulación por Computador , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Relación Señal-Ruido
14.
Eur Radiol ; 31(3): 1347-1358, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32876833

RESUMEN

OBJECTIVE: To evaluate the diagnostic performance of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) for grading hepatic inflammation. METHODS: In this retrospective cross-sectional dual-center study, 91 patients with chronic liver disease were recruited between September 2014 and September 2018. Patients underwent 3.0-T MRI examinations within 6 weeks from a liver biopsy. IVIM parameters, perfusion fraction (f), diffusion coefficient (D), and pseudo-diffusion coefficient (D*), were estimated using a voxel-wise nonlinear regression on DWI series (10 b-values from 0 to 800 s/mm2). The reference standard was histopathological analysis of hepatic inflammation grade, steatosis grade, and fibrosis stage. Intraclass correlation coefficients (ICC), univariate and multivariate correlation analyses, and areas under receiver operating characteristic curves (AUC) were assessed. RESULTS: Parameters f, D, and D* had ICCs of 0.860, 0.839, and 0.916, respectively. Correlations of f, D, and D* with inflammation grade were ρ = - 0.70, p < 0.0001; ρ = 0.10, p = 0.35; and ρ = - 0.27, p = 0.010, respectively. When adjusting for fibrosis and steatosis, the correlation between f and inflammation (p < 0.0001) remained, and that between f and fibrosis was also significant to a lesser extent (p = 0.002). AUCs of f, D, and D* for distinguishing inflammation grades 0 vs. ≥ 1 were 0.84, 0.53, and 0.70; ≤ 1 vs. ≥ 2 were 0.88, 0.57, and 0.60; and ≤ 2 vs. 3 were 0.86, 0.54, and 0.65, respectively. CONCLUSION: Perfusion fraction f strongly correlated, D very weakly correlated, and D* weakly correlated with inflammation. Among all IVIM parameters, f accurately graded inflammation and showed promise as a biomarker of hepatic inflammation. KEY POINTS: • IVIM parameters derived from DWI series with 10 b-values are reproducible for liver tissue characterization. • This retrospective two-center study showed that perfusion fraction provided good diagnostic performance for distinguishing dichotomized grades of inflammation. • Fibrosis is a significant confounder on the association between inflammation and perfusion fraction.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Hepatopatías , Estudios Transversales , Humanos , Inflamación/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Imagen por Resonancia Magnética , Movimiento (Física) , Estudios Retrospectivos
15.
Skeletal Radiol ; 50(11): 2221-2231, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33914122

RESUMEN

OBJECTIVE: To determine if T1- and T2*-mapping of the gluteal tendons can discriminate between participants with and without clinical findings of gluteal tendinopathy (GT) and if they correlate with clinical assessment. MATERIALS AND METHODS: This prospective study was conducted between January and December 2016. MRI of the hip included spin echo, short-T1 inversion recovery, variable-flip angle, and variable echo-time gradient echo sequences. MRI studies were reviewed independently by two radiologists. Two other readers segmented the gluteal tendons and T1, mono- (T2*m) and bi-exponential T2* (short (T2*s) and long (T2*l) components) were computed. RESULTS: Ten participants with GT (median age; interquartile range: 63 (57-67) years, all women) and 9 participants without GT (57 (55-59) years, 8 women) (P = 0.06) were enrolled. The sensitivity and specificity of reader 1 for disease classification were 40% (95% confidence interval (CI): 17-61%) and 70% (CI: 47-91%), and those of reader 2 were 70% (CI: 43-86%) and 80% (CI: 53-96%), with fair inter-reader agreement (Kappa = .38). T1 values could not discriminate between the two groups. The gluteal tendons T2*m and T2*s showed diagnostic accuracy ranging from .80 to .89. The posterior gluteus medius tendon T2*m and T2*s respectively showed sensitivity and specificity of 90%, and strong correlation (Spearman's rho = -.71; P = 0.02) with the Lower Extremity Functional Scale score. CONCLUSION: Quantitative MRI could help gain new insight into healthy and diseased gluteal tendons to allow better diagnosis and treatment stratification for patients.


Asunto(s)
Tendinopatía , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Tendinopatía/diagnóstico por imagen , Tendones
16.
J Physiol ; 598(14): 2875-2895, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31900932

RESUMEN

KEY POINTS: Ventricular arrhythmias are a major complication after myocardial infarction (MI), associated with sympathetic activation. The structurally heterogeneous peri-infarct zone is a known substrate, but the functional role of the myocytes is less well known. Recordings of monophasic action potentials in vivo reveal that the peri-infarct zone is a source of delayed afterdepolarizations (DADs) and has a high beat-to-beat variability of repolarization (BVR) during adrenergic stimulation (isoproterenol, ISO). Myocytes isolated from the peri-infarct region have more DADs and spontaneous action potentials, with spontaneous Ca2+ release, under ISO. These myocytes also have reduced repolarization reserve and increased BVR. Other properties of post-MI remodelling are present in both peri-infarct and remote myocytes. These data highlight the importance of altered myocyte adrenergic responses in the peri-infarct region as source and substrate of post-MI arrhythmias. ABSTRACT: Ventricular arrhythmias are a major early complication after myocardial infarction (MI). The heterogeneous peri-infarct zone forms a substrate for re-entry while arrhythmia initiation is often associated with sympathetic activation. We studied the mechanisms triggering these post-MI arrhythmias in vivo and their relation to regional myocyte remodelling. In pigs with chronic MI (6 weeks), in vivo monophasic action potentials were simultaneously recorded in the peri-infarct and remote regions during adrenergic stimulation with isoproterenol (isoprenaline; ISO). Sham animals served as controls. During infusion of ISO in vivo, the incidence of delayed afterdepolarizations (DADs) and beat-to-beat variability of repolarization (BVR) was higher in the peri-infarct than in the remote region. Myocytes isolated from the peri-infarct region, in comparison to myocytes from the remote region, had more DADs, associated with spontaneous Ca2+ release, and a higher incidence of spontaneous action potentials (APs) when exposed to ISO (9.99 ± 4.2 vs. 0.16 ± 0.05 APs/min, p = 0.004); these were suppressed by CaMKII inhibition. Peri-infarct myocytes also had reduced repolarization reserve and increased BVR (26 ± 10 ms vs. 9 ± 7 ms, P < 0.001), correlating with DAD activity. In contrast to these regional distinctions under ISO, alterations in Ca2+ handling at baseline and myocyte hypertrophy were present throughout the left ventricle (LV). Expression of some of the related genes was, however, different between the regions. In conclusion, altered myocyte adrenergic responses in the peri-infarct but not the remote region provide a source of triggered activity in vivo and of repolarization instability amplifying the substrate for re-entry. These findings stimulate further exploration of region-specific therapies targeting myocytes and autonomic modulation.


Asunto(s)
Infarto del Miocardio , Miocitos Cardíacos , Potenciales de Acción , Adrenérgicos , Animales , Arritmias Cardíacas/etiología , Porcinos
17.
Neuroimage ; 206: 116274, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31629826

RESUMEN

Phase correction (PC) is a preprocessing technique that exploits the phase of images acquired in Magnetic Resonance Imaging (MRI) to obtain real-valued images containing tissue contrast with additive Gaussian noise, as opposed to magnitude images which follow a non-Gaussian distribution, e.g. Rician. PC finds its natural application to diffusion-weighted images (DWIs) due to their inherent low signal-to-noise ratio and consequent non-Gaussianity that induces a signal overestimation bias that propagates to the calculated diffusion indices. PC effectiveness depends upon the quality of the phase estimation, which is often performed via a regularization procedure. We show that a suboptimal regularization can produce alterations of the true image contrast in the real-valued phase-corrected images. We propose adaptive phase correction (APC), a method where the phase is estimated by using MRI noise information to perform a complex-valued image regularization that accounts for the local variance of the noise. We show, on synthetic and acquired data, that APC leads to phase-corrected real-valued DWIs that present a reduced number of alterations and a reduced bias. The substantial absence of parameters for which human input is required favors a straightforward integration of APC in MRI processing pipelines.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neuroimagen/métodos , Adulto , Artefactos , Simulación por Computador , Imagen de Difusión por Resonancia Magnética/normas , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Neuroimagen/normas , Relación Señal-Ruido
18.
Neuroimage ; 205: 116255, 2020 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-31605826

RESUMEN

BACKGROUND: White matter alterations have previously been demonstrated in adolescents born with congenital heart disease (CHD) using diffusion tensor imaging (DTI). However, due to the non-specific nature of DTI metrics, it is difficult to interpret these findings in terms of their microstructural implications. This study investigated the use of neurite orientation dispersion and density imaging (NODDI), which involves the acquisition of advanced multiple b-value data over two shells and provides proxy measures of apparent axon density and orientation dispersion within white matter, as a complement to classic DTI measures. STUDY DESIGN: Youth aged 16 to 24 years born with complex CHD and healthy peers underwent brain magnetic resonance imaging. White matter tract volumes and tract-average values of DTI and NODDI metrics were compared between groups. Tract-average DTI and NODDI results were spatially confirmed using tract-based spatial statistics. RESULTS: There were widespread regions of lower tract-average neurite density index (NDI) in the CHD group as compared to the control group, particularly within long association tracts and in regions of the corpus callosum, accompanied by smaller white matter tract volumes and isolated clusters of lower fractional anisotropy (FA). There were no significant differences in orientation dispersion index (ODI) between groups. CONCLUSION: Lower apparent density of axonal packing, but not altered axonal orientation, is a key microstructural factor in the white matter abnormalities observed in youth born with CHD. These impairments in axonal packing may be an enduring consequence of early life brain injury and dysmaturation and may explain some of the long-term neuropsychological difficulties experienced by this at-risk group.


Asunto(s)
Axones/ultraestructura , Cuerpo Calloso/diagnóstico por imagen , Cardiopatías Congénitas , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología , Adolescente , Adulto , Imagen de Difusión Tensora/métodos , Femenino , Humanos , Masculino , Vías Nerviosas/diagnóstico por imagen , Neuritas/ultraestructura , Sustancia Blanca/citología , Adulto Joven
19.
Magn Reson Med ; 84(3): 1264-1279, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32065474

RESUMEN

PURPOSE: Myelin water imaging (MWI) provides a valuable biomarker for myelin, but clinical application has been restricted by long acquisition times. Accelerating the standard multi-echo T2 acquisition with gradient echoes (GRASE) or by 2D multi-slice data collection results in image blurring, contrast changes, and other issues. Compressed sensing (CS) can vastly accelerate conventional MRI. In this work, we assessed the use of CS for in vivo human MWI, using a 3D multi spin-echo sequence. METHODS: We implemented multi-echo T2 relaxation imaging with compressed sensing (METRICS) and METRICS with partial Fourier acceleration (METRICS-PF). Scan-rescan data were acquired from 12 healthy controls for assessment of repeatability. MWI data were acquired for METRICS in 9 m:58 s and for METRICS-PF in 7 m:25 s, both with 1.5 × 2 × 3 mm3 voxels, 56 echoes, 7 ms ΔTE, and 240 × 240 × 170 mm3 FOV. METRICS was compared with a novel multi-echo spin-echo gold-standard (MSE-GS) MWI acquisition, acquired for a single additional subject in 2 h:2 m:40 s. RESULTS: METRICS/METRICS-PF myelin water fraction had mean: repeatability coefficient 1.5/1.1, coefficient of variation 6.2/4.5%, and intra-class correlation coefficient 0.79/0.84. Repeatability metrics comparing METRICS with METRICS-PF were similar, and both sequences agreed with reference values from literature. METRICS images and quantitative maps showed excellent qualitative agreement with those of MSE-GS. CONCLUSION: METRICS and METRICS-PF provided highly repeatable MWI data without the inherent disadvantages of GRASE or 2D multi-slice acquisition. CS acceleration allows MWI data to be acquired rapidly with larger FOV, higher estimated SNR, more isotropic voxels and more echoes than with previous techniques. The approach introduced here generalizes to any multi-component T2 mapping application.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Vaina de Mielina , Benchmarking , Humanos , Imagen por Resonancia Magnética , Agua
20.
J Magn Reson Imaging ; 51(5): 1570-1580, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31605412

RESUMEN

BACKGROUND: MR elastography is a noninvasive technique that provides high diagnostic accuracy for the staging of liver fibrosis; however, it requires external hardware and mainly assesses the right lobe. PURPOSE: To evaluate the diagnostic performance of MRI cine-tagging for staging fibrosis in the left liver lobe, using biopsy as the reference standard. STUDY TYPE: Institutional Review Board (IRB)-approved two-center prospective study. POPULATION: Seventy-six patients with chronic liver disease who underwent an MRI cine-tagging examination and a liver biopsy within a 6-week interval. FIELD STRENGTH/SEQUENCE: 2D-GRE multislice sequence at 3.0T with spatial modulation of the magnetization preparation sequence and peripheral pulse-wave triggering on two coronal slices chosen underneath the heart apex to capture maximal deformation with consecutive breath-holds adapted to patient cardiac frequency. ASSESSMENT: A region of interest was selected in the liver close to the heart apex. Maximal strain was evaluated with the harmonic phase (HARP) technique. STATISTICAL TESTS: Spearman's correlation, Kruskal-Wallis test, Mann-Whitney U-test, and receiver operating characteristic (ROC) analysis were performed. RESULTS: Liver strain measured on tagged images decreased with higher histological fibrosis stage (ρ = -0.68, P < 0.0001). Strain values were significantly different between all fibrosis stages (P < 0.0001), and between groups of fibrosis stages ≤F3 vs. F4 (P < 0.05). Areas under the ROC curves were 0.95 (95% confidence interval: 0.89-1.00) to distinguish fibrosis stages F0 vs. F4, 0.81 (0.70-0.92) for stages F0 vs. ≥F1, 0.84 (0.76-0.93) for stages ≤F1 vs. ≥F2, 0.86 (0.78-0.94) for stages ≤F2 vs. ≥F3, and 0.87 (0.77-0.96) for stages ≤F3 vs. F4. DATA CONCLUSION: MRI cine-tagging is a promising technique for measuring liver strain without additional elastography hardware. It could be used to assess the left liver lobe as a complement to current techniques assessing the right lobe. LEVEL OF EVIDENCE: 1 Technical Efficacy: 3 J. Magn. Reson. Imaging 2020;51:1570-1580.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática , Biopsia , Humanos , Hígado/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Estudios Prospectivos , Curva ROC
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA