Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo de estudio
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(4)2023 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-36850867

RESUMEN

Compressive sensing (CS) has been proposed as a disruptive approach to developing a novel class of optical instrumentation used in diverse application domains. Thanks to sparsity as an inherent feature of many natural signals, CS allows for the acquisition of the signal in a very compact way, merging acquisition and compression in a single step and, furthermore, offering the capability of using a limited number of detector elements to obtain a reconstructed image with a larger number of pixels. Although the CS paradigm has already been applied in several application domains, from medical diagnostics to microscopy, studies related to space applications are very limited. In this paper, we present and discuss the instrumental concept, optical design, and performances of a CS imaging spectrometer for ultraviolet-visible (UV-Vis) stellar spectroscopy. The instrument-which is pixel-limited in the entire 300 nm-650 nm spectral range-features spectral sampling that ranges from 2.2 nm@300 nm to 22 nm@650 nm, with a total of 50 samples for each spectrum. For data reconstruction quality, the results showed good performance, measured by several quality metrics chosen from those recommended by CCSDS. The designed instrument can achieve compression ratios of 20 or higher without a significant loss of information. A pros and cons analysis of the CS approach is finally carried out, highlighting main differences with respect to a traditional system.

2.
Opt Express ; 18(11): 11622-49, 2010 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-20589022

RESUMEN

Recent investigations have induced relevant advancements of imaging interferometry, which is becoming a viable option for Earth remote sensing. Various research programs have chosen the Sagnac configuration for new imaging interferometers. Due to the growing diffusion of this technique, we have developed a self-contained theory for describing the signal produced by triangular FTSs and its optimal processing. We investigate the relevant disadvantages of multiplexing, and compare dispersive with FTS instruments. The paper addresses some methods for correcting the phase error, and the non-unitary transformation performed by a Sagnac interferometer. The effect of noise on spectral estimations is discussed.


Asunto(s)
Interferometría/instrumentación , Espectroscopía Infrarroja por Transformada de Fourier/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
3.
Appl Opt ; 49(28): 5366-73, 2010 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-20885473

RESUMEN

Recent theoretical investigations have shown important radiometric disadvantages of interferential multiplexing in Fourier transform spectrometry that apparently can be applied even to coded aperture spectrometers. We have reexamined the methods of noninterferential multiplexing in order to assess their signal-to-noise ratio (SNR) performance, relying on a theoretical modeling of the multiplexed signals. We are able to show that quite similar SNR and radiometric disadvantages affect multiplex dispersive spectrometry. The effect of noise on spectral estimations is discussed.

4.
J Environ Manage ; 90(7): 2278-86, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-18423842

RESUMEN

The San Rossore Natural Park, located on the Tuscany (Italy) coast, has been utilized over the last 10 years for many remote sensing campaigns devoted to coastal zone monitoring. A wet area is located in the south-west part of the Natural Park and it is characterized by a system of ponds and dunes formed by sediment deposition occurring at the Arno River estuary. The considerable amount of collected data has permitted us to investigate the evolution of wetland spreading and land coverage as well as to retrieve relevant biogeochemical parameters, e.g. green biomass, from remote sensing images and products. This analysis has proved that the monitoring of coastal wetlands, characterized by shallow waters, moor and dunes, demands dedicated aerospace sensors with high spatial and spectral resolution. The outcomes of the processing of images gathered during several remote sensing campaigns by airborne and spaceborne hyperspectral sensors are presented and discussed. A particular effort has been devoted to sensor response calibration and data validation due to the complex heterogeneity of the observed natural surfaces.


Asunto(s)
Conservación de los Recursos Naturales/métodos , Monitoreo del Ambiente/métodos , Humedales , Geografía , Italia , Comunicaciones por Satélite
5.
Appl Opt ; 43(29): 5552-63, 2004 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-15508614

RESUMEN

A new algorithm for the retrieval of columnar water vapor content is presented. The proposed procedure computes the area of the H2O absorption centered about 940 nm to allow its integrated columnar abundance as well as its density at ground level to be assessed. The procedure utilizes the HITRAN 2000 database as the source of H2O cross-section spectra. Experimental results were derived from radiometrically calibrated hyperspectral images collected by the Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) sensor over the Cuprite mining district in Nevada. Numerical simulations based on the MODTRAN 4 radiative transfer code were also employed for investigating the algorithm's performance. An additional empirical H2O retrieval procedure was tested by use of data gathered by the VIRS-200 imaging spectrometer.

6.
Appl Opt ; 43(1): 183-95, 2004 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-14714661

RESUMEN

A new solar spectral irradiometer that operates in the visible and near-infrared spectral ranges has been developed. This instrument takes advantage of a new concept optical head that collects the light that impinges on a hemispheric surface, thus improving the instrument angular response with respect to traditional devices. The technical characteristics of the instrument are investigated and detailed, and its radiometric calibration, performed by means of a Langley-like method, is discussed. A new simplified theoretical model that accounts for the diffuse irradiance observed in an optically thin plane-parallel atmosphere has been developed to improve the fit of the irradiance diurnal evolution. An alternative polynomial parametric representation of monochromatic diffuse irradiance evolution has been attempted, but satisfactory results were not obtained from the fitting of experimental data. The new instrument could be useful to carry out remote-sensing validation campaigns.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA