Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nature ; 573(7772): 61-68, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31435019

RESUMEN

Elucidating the cellular architecture of the human cerebral cortex is central to understanding our cognitive abilities and susceptibility to disease. Here we used single-nucleus RNA-sequencing analysis to perform a comprehensive study of cell types in the middle temporal gyrus of human cortex. We identified a highly diverse set of excitatory and inhibitory neuron types that are mostly sparse, with excitatory types being less layer-restricted than expected. Comparison to similar mouse cortex single-cell RNA-sequencing datasets revealed a surprisingly well-conserved cellular architecture that enables matching of homologous types and predictions of properties of human cell types. Despite this general conservation, we also found extensive differences between homologous human and mouse cell types, including marked alterations in proportions, laminar distributions, gene expression and morphology. These species-specific features emphasize the importance of directly studying human brain.


Asunto(s)
Astrocitos/clasificación , Evolución Biológica , Corteza Cerebral/citología , Corteza Cerebral/metabolismo , Neuronas/clasificación , Adolescente , Adulto , Anciano , Animales , Astrocitos/citología , Femenino , Humanos , Masculino , Ratones , Persona de Mediana Edad , Inhibición Neural , Neuronas/citología , Análisis de Componente Principal , RNA-Seq , Análisis de la Célula Individual , Especificidad de la Especie , Transcriptoma/genética , Adulto Joven
2.
Epilepsia ; 61(8): 1749-1757, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32658325

RESUMEN

OBJECTIVE: The RNS System is a direct brain-responsive neurostimulation system that is US Food and Drug Administration-approved for adults with medically intractable focal onset seizures based on safety and effectiveness data from controlled clinical trials. The purpose of this study was to retrospectively evaluate the real-world safety and effectiveness of the RNS System. METHODS: Eight comprehensive epilepsy centers conducted a chart review of patients treated with the RNS System for at least 1 year, in accordance with the indication for use. Data included device-related serious adverse events and the median percent change in disabling seizure frequency from baseline at years 1, 2, and 3 of treatment and at the most recent follow-up. RESULTS: One hundred fifty patients met the criteria for analysis. The median reduction in seizures was 67% (interquartile range [IQR] = 33%-93%, n = 149) at 1 year, 75% (IQR = 50%-94%, n = 93) at 2 years, 82% (IQR = 50%-96%, n = 38) at ≥3 years, and 74% (IQR = 50%-96%, n = 150) at last follow-up (mean = 2.3 years). Thirty-five percent of patients had a ≥90% seizure frequency reduction, and 18% of patients reported being clinically seizure-free at last follow-up. Seizure frequency reductions were similar regardless of patient age, age at epilepsy onset, duration of epilepsy, seizure onset in mesial temporal or neocortical foci, magnetic resonance imaging findings, prior intracranial monitoring, prior epilepsy surgery, or prior vagus nerve stimulation treatment. The infection rate per procedure was 2.9% (6/150 patients); five of the six patients had an implant site infection, and one had osteomyelitis. Lead revisions were required in 2.7% (4/150), and 2.0% (3/150) of patients had a subdural hemorrhage, none of which had long-lasting neurological consequences. SIGNIFICANCE: In this real-world experience, safety was similar and clinical seizure outcomes exceeded those of the prospective clinical trials, corroborating effectiveness of this therapy and suggesting that clinical experience has informed more effective programming.


Asunto(s)
Epilepsia Refractaria/terapia , Terapia por Estimulación Eléctrica/métodos , Epilepsias Parciales/terapia , Neuroestimuladores Implantables , Adolescente , Adulto , Anciano , Electrocorticografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
3.
Epilepsia ; 61(3): 408-420, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32072621

RESUMEN

OBJECTIVE: To describe seizure outcomes in patients with medically refractory epilepsy who had evidence of bilateral mesial temporal lobe (MTL) seizure onsets and underwent MTL resection based on chronic ambulatory intracranial EEG (ICEEG) data from a direct brain-responsive neurostimulator (RNS) system. METHODS: We retrospectively identified all patients at 17 epilepsy centers with MTL epilepsy who were treated with the RNS System using bilateral MTL leads, and in whom an MTL resection was subsequently performed. Presumed lateralization based on routine presurgical approaches was compared to lateralization determined by RNS System chronic ambulatory ICEEG recordings. The primary outcome was frequency of disabling seizures at last 3-month follow-up after MTL resection compared to seizure frequency 3 months before MTL resection. RESULTS: We identified 157 patients treated with the RNS System with bilateral MTL leads due to presumed bitemporal epilepsy. Twenty-five patients (16%) subsequently had an MTL resection informed by chronic ambulatory ICEEG (mean = 42 months ICEEG); follow-up was available for 24 patients. After MTL resection, the median reduction in disabling seizures at last follow-up was 100% (mean: 94%; range: 50%-100%). Nine patients (38%) had exclusively unilateral electrographic seizures recorded by chronic ambulatory ICEEG and all were seizure-free at last follow-up after MTL resection; eight of nine continued RNS System treatment. Fifteen patients (62%) had bilateral MTL electrographic seizures, had an MTL resection on the more active side, continued RNS System treatment, and achieved a median clinical seizure reduction of 100% (mean: 90%; range: 50%-100%) at last follow-up, with eight of fifteen seizure-free. For those with more than 1 year of follow-up (N = 21), 15 patients (71%) were seizure-free during the most recent year, including all eight patients with unilateral onsets and 7 of 13 patients (54%) with bilateral onsets. SIGNIFICANCE: Chronic ambulatory ICEEG data provide information about lateralization of MTL seizures and can identify additional patients who may benefit from MTL resection.


Asunto(s)
Lobectomía Temporal Anterior/métodos , Epilepsia Refractaria/cirugía , Epilepsia del Lóbulo Temporal/cirugía , Lóbulo Temporal/cirugía , Adulto , Anciano , Epilepsia Refractaria/fisiopatología , Terapia por Estimulación Eléctrica , Electrocorticografía , Epilepsia del Lóbulo Temporal/fisiopatología , Femenino , Humanos , Neuroestimuladores Implantables , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio , Procedimientos Neuroquirúrgicos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
4.
Epilepsia ; 59(3): 555-561, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29336029

RESUMEN

OBJECTIVE: To study the incidence and clinical features of sudden unexpected death in epilepsy (SUDEP) in patients treated with direct brain-responsive stimulation with the RNS System. METHODS: All deaths in patients treated in clinical trials (N = 256) or following U.S. Food and Drug Administration (FDA) approval (N = 451) through May 5, 2016, were adjudicated for SUDEP. RESULTS: There were 14 deaths among 707 patients (2208 postimplantation years), including 2 possible, 1 probable, and 4 definite SUDEP events. The rate of probable or definite SUDEP was 2.0/1000 (95% confidence interval [CI] 0.7-5.2) over 2036 patient stimulation years and 2.3/1000 (95% CI 0.9-5.4) over 2208 patient implant years. Stored electrocorticograms around the time of death were available for 4 patients with probable/definite SUDEP and revealed the following: frequent epileptiform activity ending abruptly (n = 2), no epileptiform activity or seizures (n = 1), and an electrographic and witnessed seizure with cessation of postictal electrocorticography (ECoG) activity associated with apnea and pulselessness (n = 1). SIGNIFICANCE: The SUDEP rate of 2.0/1000 patient stimulation years among patients treated with the RNS System is favorable relative to treatment-resistant epilepsy patients randomized to the placebo arm of add-on drug studies or with seizures after resective surgery. Our findings support that treatments that reduce seizures reduce SUDEP risk and that not all SUDEPs follow seizures.


Asunto(s)
Encéfalo/fisiopatología , Muerte Súbita/epidemiología , Terapia por Estimulación Eléctrica/métodos , Epilepsia/fisiopatología , Neuroestimuladores Implantables , Adolescente , Adulto , Anciano , Muerte Súbita/prevención & control , Terapia por Estimulación Eléctrica/mortalidad , Terapia por Estimulación Eléctrica/tendencias , Electrocorticografía/tendencias , Epilepsia/mortalidad , Femenino , Humanos , Neuroestimuladores Implantables/tendencias , Masculino , Persona de Mediana Edad , Adulto Joven
5.
J Neurooncol ; 136(1): 181-188, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29098571

RESUMEN

Appropriate management of adult gliomas requires an accurate histopathological diagnosis. However, the heterogeneity of gliomas can lead to misdiagnosis and undergrading, especially with biopsy. We evaluated the role of preoperative relative cerebral blood volume (rCBV) analysis in conjunction with histopathological analysis as a predictor of overall survival and risk of undergrading. We retrospectively identified 146 patients with newly diagnosed gliomas (WHO grade II-IV) that had undergone preoperative MRI with rCBV analysis. We compared overall survival by histopathologically determined WHO tumor grade and by rCBV using Kaplan-Meier survival curves and the Cox proportional hazards model. We also compared preoperative imaging findings and initial histopathological diagnosis in 13 patients who underwent biopsy followed by subsequent resection. Survival curves by WHO grade and rCBV tier similarly separated patients into low, intermediate, and high-risk groups with shorter survival corresponding to higher grade or rCBV tier. The hazard ratio for WHO grade III versus II was 3.91 (p = 0.018) and for grade IV versus II was 11.26 (p < 0.0001) and the hazard ratio for each increase in 1.0 rCBV units was 1.12 (p < 0.002). Additionally, 3 of 13 (23%) patients initially diagnosed by biopsy were upgraded on subsequent resection. Preoperative rCBV was elevated at least one standard deviation above the mean in the 3 upgraded patients, suggestive of undergrading, but not in the ten concordant diagnoses. In conclusion, rCBV can predict overall survival similarly to pathologically determined WHO grade in patients with gliomas. Discordant rCBV analysis and histopathology may help identify patients at higher risk for undergrading.


Asunto(s)
Neoplasias Encefálicas/irrigación sanguínea , Volumen Sanguíneo Cerebral , Glioma/irrigación sanguínea , Adulto , Anciano , Biopsia , Determinación del Volumen Sanguíneo , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/patología , Femenino , Glioma/diagnóstico , Glioma/patología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Periodo Preoperatorio , Factores de Riesgo
6.
Epilepsia ; 58(6): 994-1004, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28398014

RESUMEN

OBJECTIVE: Evaluate the seizure-reduction response and safety of mesial temporal lobe (MTL) brain-responsive stimulation in adults with medically intractable partial-onset seizures of mesial temporal lobe origin. METHODS: Subjects with mesial temporal lobe epilepsy (MTLE) were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. RESULTS: There were 111 subjects with MTLE; 72% of subjects had bilateral MTL onsets and 28% had unilateral onsets. Subjects had one to four leads placed; only two leads could be connected to the device. Seventy-six subjects had depth leads only, 29 had both depth and strip leads, and 6 had only strip leads. The mean follow-up was 6.1 ± (standard deviation) 2.2 years. The median percent seizure reduction was 70% (last observation carried forward). Twenty-nine percent of subjects experienced at least one seizure-free period of 6 months or longer, and 15% experienced at least one seizure-free period of 1 year or longer. There was no difference in seizure reduction in subjects with and without mesial temporal sclerosis (MTS), bilateral MTL onsets, prior resection, prior intracranial monitoring, and prior vagus nerve stimulation. In addition, seizure reduction was not dependent on the location of depth leads relative to the hippocampus. The most frequent serious device-related adverse event was soft tissue implant-site infection (overall rate, including events categorized as device-related, uncertain, or not device-related: 0.03 per implant year, which is not greater than with other neurostimulation devices). SIGNIFICANCE: Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including patients with unilateral or bilateral MTLE who are not candidates for temporal lobectomy or who have failed a prior MTL resection.


Asunto(s)
Encéfalo/fisiopatología , Estimulación Encefálica Profunda/métodos , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/terapia , Terapia por Estimulación Eléctrica/métodos , Electroencefalografía , Epilepsias Parciales/fisiopatología , Epilepsias Parciales/terapia , Epilepsia del Lóbulo Temporal/fisiopatología , Epilepsia del Lóbulo Temporal/terapia , Adolescente , Adulto , Dominancia Cerebral/fisiología , Electrodos Implantados , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Cuidados a Largo Plazo , Masculino , Persona de Mediana Edad , Adulto Joven
7.
Epilepsia ; 58(6): 1005-1014, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28387951

RESUMEN

OBJECTIVE: Evaluate the seizure-reduction response and safety of brain-responsive stimulation in adults with medically intractable partial-onset seizures of neocortical origin. METHODS: Patients with partial seizures of neocortical origin were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. Additional analyses considered safety and seizure reduction according to lobe and functional area (e.g., eloquent cortex) of seizure onset. RESULTS: There were 126 patients with seizures of neocortical onset. The average follow-up was 6.1 implant years. The median percent seizure reduction was 70% in patients with frontal and parietal seizure onsets, 58% in those with temporal neocortical onsets, and 51% in those with multilobar onsets (last observation carried forward [LOCF] analysis). Twenty-six percent of patients experienced at least one seizure-free period of 6 months or longer and 14% experienced at least one seizure-free period of 1 year or longer. Patients with lesions on magnetic resonance imaging (MRI; 77% reduction, LOCF) and those with normal MRI findings (45% reduction, LOCF) benefitted, although the treatment response was more robust in patients with an MRI lesion (p = 0.02, generalized estimating equation [GEE]). There were no differences in the seizure reduction in patients with and without prior epilepsy surgery or vagus nerve stimulation. Stimulation parameters used for treatment did not cause acute or chronic neurologic deficits, even in eloquent cortical areas. The rates of infection (0.017 per patient implant year) and perioperative hemorrhage (0.8%) were not greater than with other neurostimulation devices. SIGNIFICANCE: Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including adults with seizures of neocortical onset, and those with onsets from eloquent cortex.


Asunto(s)
Corteza Cerebral/fisiopatología , Estimulación Encefálica Profunda/métodos , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/terapia , Terapia por Estimulación Eléctrica/métodos , Electroencefalografía , Neocórtex/fisiopatología , Adolescente , Adulto , Mapeo Encefálico , Estimulación Encefálica Profunda/instrumentación , Terapia por Estimulación Eléctrica/instrumentación , Electrodos Implantados , Epilepsias Parciales/fisiopatología , Epilepsias Parciales/terapia , Epilepsia Parcial Compleja/fisiopatología , Epilepsia Parcial Compleja/terapia , Epilepsia Parcial Motora/fisiopatología , Epilepsia Parcial Motora/terapia , Epilepsia Tónico-Clónica/fisiopatología , Epilepsia Tónico-Clónica/terapia , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
8.
Stereotact Funct Neurosurg ; 95(5): 325-329, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28910805

RESUMEN

BACKGROUND/AIMS: The RNS® System utilizes a cranially implanted neurostimulator attached to leads placed at the seizure focus to provide brain responsive stimulation for the treatment of medically intractable partial onset epilepsy. Infection and erosion rates related to the cranial implant site were assessed overall and by neurostimulator procedure to determine whether rates increased with additional procedures. METHODS: Infection and erosion rates were calculated as (1) chance per neurostimulator procedure, (2) incidence per patient implant year, and (3) rates for initial and each subsequent neurostimulator implant (generalized estimating equation). RESULTS: In 256 patients followed for an average of 7 years, the infection rate was 3.7% per neurostimulator procedure (n = 31/840), and the rate of erosions was 0.8% per neurostimulator procedure (n = 7/840). Rates did not increase with subsequent neurostimulator procedures (p = 0.66, infection; p = 0.70, erosion). A prior infection or erosion at the implant site did not significantly increase the risk at a later procedure (p ≥ 0.05 for all combinations). CONCLUSION: These data indicate that the risk for infection compares favorably to other neurostimulation devices and suggest that rates of infection and erosion do not increase with subsequent neurostimulator replacements.


Asunto(s)
Epilepsia Refractaria/terapia , Contaminación de Equipos , Neuroestimuladores Implantables/efectos adversos , Neuroestimuladores Implantables/tendencias , Epilepsia Refractaria/epidemiología , Contaminación de Equipos/prevención & control , Diseño de Equipo/efectos adversos , Diseño de Equipo/instrumentación , Diseño de Equipo/tendencias , Femenino , Humanos , Neuroestimuladores Implantables/microbiología , Masculino , Persona de Mediana Edad , Convulsiones/epidemiología , Convulsiones/terapia , Técnicas Estereotáxicas/efectos adversos , Técnicas Estereotáxicas/instrumentación , Técnicas Estereotáxicas/tendencias , Adulto Joven
9.
Epilepsia ; 56(6): 959-67, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25988840

RESUMEN

OBJECTIVE: Patients with suspected mesial temporal lobe (MTL) epilepsy typically undergo inpatient video-electroencephalography (EEG) monitoring with scalp and/or intracranial electrodes for 1 to 2 weeks to localize and lateralize the seizure focus or foci. Chronic ambulatory electrocorticography (ECoG) in patients with MTL epilepsy may provide additional information about seizure lateralization. This analysis describes data obtained from chronic ambulatory ECoG in patients with suspected bilateral MTL epilepsy in order to assess the time required to determine the seizure lateralization and whether this information could influence treatment decisions. METHODS: Ambulatory ECoG was reviewed in patients with suspected bilateral MTL epilepsy who were among a larger cohort with intractable epilepsy participating in a randomized controlled trial of responsive neurostimulation. Subjects were implanted with bilateral MTL leads and a cranially implanted neurostimulator programmed to detect abnormal interictal and ictal ECoG activity. ECoG data stored by the neurostimulator were reviewed to determine the lateralization of electrographic seizures and the interval of time until independent bilateral MTL electrographic seizures were recorded. RESULTS: Eighty-two subjects were implanted with bilateral MTL leads and followed for 4.7 years on average (median 4.9 years). Independent bilateral MTL electrographic seizures were recorded in 84%. The average time to record bilateral electrographic seizures in the ambulatory setting was 41.6 days (median 13 days, range 0-376 days). Sixteen percent had only unilateral electrographic seizures after an average of 4.6 years of recording. SIGNIFICANCE: About one third of the subjects implanted with bilateral MTL electrodes required >1 month of chronic ambulatory ECoG before the first contralateral MTL electrographic seizure was recorded. Some patients with suspected bilateral MTL seizures had only unilateral electrographic seizures. Chronic ambulatory ECoG in patients with suspected bilateral MTL seizures provides data in a naturalistic setting, may complement data from inpatient video-EEG monitoring, and can contribute to treatment decisions.


Asunto(s)
Ondas Encefálicas/fisiología , Electrocardiografía Ambulatoria , Epilepsia del Lóbulo Temporal/patología , Epilepsia del Lóbulo Temporal/fisiopatología , Lateralidad Funcional/fisiología , Adolescente , Adulto , Electrodos Implantados , Femenino , Hipocampo/patología , Hipocampo/fisiopatología , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
10.
Epilepsia ; 55(3): 432-41, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24621228

RESUMEN

OBJECTIVE: To demonstrate the safety and effectiveness of responsive stimulation at the seizure focus as an adjunctive therapy to reduce the frequency of seizures in adults with medically intractable partial onset seizures arising from one or two seizure foci. METHODS: Randomized multicenter double-blinded controlled trial of responsive focal cortical stimulation (RNS System). Subjects with medically intractable partial onset seizures from one or two foci were implanted, and 1 month postimplant were randomized 1:1 to active or sham stimulation. After the fifth postimplant month, all subjects received responsive stimulation in an open label period (OLP) to complete 2 years of postimplant follow-up. RESULTS: All 191 subjects were randomized. The percent change in seizures at the end of the blinded period was -37.9% in the active and -17.3% in the sham stimulation group (p = 0.012, Generalized Estimating Equations). The median percent reduction in seizures in the OLP was 44% at 1 year and 53% at 2 years, which represents a progressive and significant improvement with time (p < 0.0001). The serious adverse event rate was not different between subjects receiving active and sham stimulation. Adverse events were consistent with the known risks of an implanted medical device, seizures, and of other epilepsy treatments. There were no adverse effects on neuropsychological function or mood. SIGNIFICANCE: Responsive stimulation to the seizure focus reduced the frequency of partial-onset seizures acutely, showed improving seizure reduction over time, was well tolerated, and was acceptably safe. The RNS System provides an additional treatment option for patients with medically intractable partial-onset seizures.


Asunto(s)
Terapia por Estimulación Eléctrica/tendencias , Epilepsias Parciales/diagnóstico , Epilepsias Parciales/terapia , Neuroestimuladores Implantables/tendencias , Adolescente , Adulto , Anciano , Método Doble Ciego , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Epilepsias Parciales/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida/psicología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
Cell Rep ; 43(4): 114100, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38607921

RESUMEN

Hippocampal pyramidal neuron activity underlies episodic memory and spatial navigation. Although extensively studied in rodents, extremely little is known about human hippocampal pyramidal neurons, even though the human hippocampus underwent strong evolutionary reorganization and shows lower theta rhythm frequencies. To test whether biophysical properties of human Cornu Amonis subfield 1 (CA1) pyramidal neurons can explain observed rhythms, we map the morpho-electric properties of individual CA1 pyramidal neurons in human, non-pathological hippocampal slices from neurosurgery. Human CA1 pyramidal neurons have much larger dendritic trees than mouse CA1 pyramidal neurons, have a large number of oblique dendrites, and resonate at 2.9 Hz, optimally tuned to human theta frequencies. Morphological and biophysical properties suggest cellular diversity along a multidimensional gradient rather than discrete clustering. Across the population, dendritic architecture and a large number of oblique dendrites consistently boost memory capacity in human CA1 pyramidal neurons by an order of magnitude compared to mouse CA1 pyramidal neurons.


Asunto(s)
Región CA1 Hipocampal , Dendritas , Células Piramidales , Humanos , Células Piramidales/fisiología , Región CA1 Hipocampal/citología , Región CA1 Hipocampal/fisiología , Animales , Masculino , Ratones , Dendritas/fisiología , Femenino , Persona de Mediana Edad , Anciano , Ritmo Teta/fisiología , Adulto
13.
Elife ; 122023 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-37249212

RESUMEN

Rodent studies have demonstrated that synaptic dynamics from excitatory to inhibitory neuron types are often dependent on the target cell type. However, these target cell-specific properties have not been well investigated in human cortex, where there are major technical challenges in reliably obtaining healthy tissue, conducting multiple patch-clamp recordings on inhibitory cell types, and identifying those cell types. Here, we take advantage of newly developed methods for human neurosurgical tissue analysis with multiple patch-clamp recordings, post-hoc fluorescent in situ hybridization (FISH), machine learning-based cell type classification and prospective GABAergic AAV-based labeling to investigate synaptic properties between pyramidal neurons and PVALB- vs. SST-positive interneurons. We find that there are robust molecular differences in synapse-associated genes between these neuron types, and that individual presynaptic pyramidal neurons evoke postsynaptic responses with heterogeneous synaptic dynamics in different postsynaptic cell types. Using molecular identification with FISH and classifiers based on transcriptomically identified PVALB neurons analyzed by Patch-seq, we find that PVALB neurons typically show depressing synaptic characteristics, whereas other interneuron types including SST-positive neurons show facilitating characteristics. Together, these data support the existence of target cell-specific synaptic properties in human cortex that are similar to rodent, thereby indicating evolutionary conservation of local circuit connectivity motifs from excitatory to inhibitory neurons and their synaptic dynamics.


Asunto(s)
Neocórtex , Humanos , Neocórtex/fisiología , Transmisión Sináptica/fisiología , Hibridación Fluorescente in Situ , Estudios Prospectivos , Neuronas/fisiología , Células Piramidales/fisiología , Sinapsis/fisiología , Interneuronas/fisiología
14.
Elife ; 112022 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-35880860

RESUMEN

Serial-section electron microscopy (ssEM) is the method of choice for studying macroscopic biological samples at extremely high resolution in three dimensions. In the nervous system, nanometer-scale images are necessary to reconstruct dense neural wiring diagrams in the brain, so -called connectomes. The data that can comprise of up to 108 individual EM images must be assembled into a volume, requiring seamless 2D registration from physical section followed by 3D alignment of the stitched sections. The high throughput of ssEM necessitates 2D stitching to be done at the pace of imaging, which currently produces tens of terabytes per day. To achieve this, we present a modular volume assembly software pipeline ASAP (Assembly Stitching and Alignment Pipeline) that is scalable to datasets containing petabytes of data and parallelized to work in a distributed computational environment. The pipeline is built on top of the Render Trautman and Saalfeld (2019) services used in the volume assembly of the brain of adult Drosophila melanogaster (Zheng et al. 2018). It achieves high throughput by operating only on image meta-data and transformations. ASAP is modular, allowing for easy incorporation of new algorithms without significant changes in the workflow. The entire software pipeline includes a complete set of tools for stitching, automated quality control, 3D section alignment, and final rendering of the assembled volume to disk. ASAP has been deployed for continuous stitching of several large-scale datasets of the mouse visual cortex and human brain samples including one cubic millimeter of mouse visual cortex (Yin et al. 2020); Microns Consortium et al. (2021) at speeds that exceed imaging. The pipeline also has multi-channel processing capabilities and can be applied to fluorescence and multi-modal datasets like array tomography.


Asunto(s)
Algoritmos , Drosophila melanogaster , Animales , Encéfalo , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Ratones , Microscopía Electrónica , Programas Informáticos
15.
Science ; 375(6585): eabj5861, 2022 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-35271334

RESUMEN

We present a unique, extensive, and open synaptic physiology analysis platform and dataset. Through its application, we reveal principles that relate cell type to synaptic properties and intralaminar circuit organization in the mouse and human cortex. The dynamics of excitatory synapses align with the postsynaptic cell subclass, whereas inhibitory synapse dynamics partly align with presynaptic cell subclass but with considerable overlap. Synaptic properties are heterogeneous in most subclass-to-subclass connections. The two main axes of heterogeneity are strength and variability. Cell subclasses divide along the variability axis, whereas the strength axis accounts for substantial heterogeneity within the subclass. In the human cortex, excitatory-to-excitatory synaptic dynamics are distinct from those in the mouse cortex and vary with depth across layers 2 and 3.


Asunto(s)
Neocórtex/fisiología , Vías Nerviosas , Neuronas/fisiología , Sinapsis/fisiología , Transmisión Sináptica , Adulto , Animales , Conjuntos de Datos como Asunto , Potenciales Postsinápticos Excitadores , Femenino , Humanos , Potenciales Postsinápticos Inhibidores , Masculino , Ratones , Ratones Transgénicos , Modelos Neurológicos , Neocórtex/citología , Lóbulo Temporal/citología , Lóbulo Temporal/fisiología , Corteza Visual/citología , Corteza Visual/fisiología
16.
Seizure ; 85: 145-150, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33465639

RESUMEN

PURPOSE: There are multidien patterns of seizure occurrence. Predicting seizure risk may be easier with biomarker correlates to multidien patterns. We hypothesize multiday hyper or hypoglycemia contributes to seizure risk. METHODS: In a type I diabetic (T1D) with focal onset epilepsy with continuous glucose monitoring (CGM) and responsive neurostimulation (RNS) devices, we studied multiday interictal activities (IEA), seizures, and glucose. Hourly CGM data was matched to hourly RNS captures of interictal and ictal activities over 33 months. RNS detection settings were unchanged. Multidien cycles were analyzed, active blocks of IEA and ictal episodes defined, and tissue glucose averages studied. RESULTS: Average glucose was 161 mg/dl. A 40-day cycle of interictal and ictal activities occurred, though no similar glucose cycle was evident. Glucose elevations relative to patient average were associated with increases in IEA but not seizure. Frequent seizures were not associated with obvious elevations or decreases of glucose from baseline, most seizures occurred at +/- 10 mg/dl of average daily glucose (i.e. 150-170 mg/dl). CONCLUSION: Tissue glucose may influence IEA but may not influence multiday seizure activity or very frequent seizures. In an ambulatory T1D patient multiday hypo or hyperglycemic extremes do not appear to provoke seizure activities.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Electroencefalografía , Glucosa , Humanos , Convulsiones
17.
Neuron ; 109(18): 2914-2927.e5, 2021 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-34534454

RESUMEN

In the neocortex, subcerebral axonal projections originate largely from layer 5 (L5) extratelencephalic-projecting (ET) neurons. The unique morpho-electric properties of these neurons have been mainly described in rodents, where retrograde tracers or transgenic lines can label them. Similar labeling strategies are infeasible in the human neocortex, rendering the translational relevance of findings in rodents unclear. We leveraged the recent discovery of a transcriptomically defined L5 ET neuron type to study the properties of human L5 ET neurons in neocortical brain slices derived from neurosurgeries. Patch-seq recordings, where transcriptome, physiology, and morphology were assayed from the same cell, revealed many conserved morpho-electric properties of human and rodent L5 ET neurons. Divergent properties were often subtler than differences between L5 cell types within these two species. These data suggest a conserved function of L5 ET neurons in the neocortical hierarchy but also highlight phenotypic divergence possibly related to functional specialization of human neocortex.


Asunto(s)
Dendritas/fisiología , Morfogénesis/fisiología , Neocórtex/citología , Neocórtex/fisiología , Células Piramidales/fisiología , Transcriptoma/fisiología , Potenciales de Acción/fisiología , Adulto , Animales , Femenino , Humanos , Macaca nemestrina , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Persona de Mediana Edad , Técnicas de Cultivo de Órganos , Técnicas de Placa-Clamp/métodos
18.
Cell Rep ; 34(13): 108754, 2021 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-33789096

RESUMEN

Viral genetic tools that target specific brain cell types could transform basic neuroscience and targeted gene therapy. Here, we use comparative open chromatin analysis to identify thousands of human-neocortical-subclass-specific putative enhancers from across the genome to control gene expression in adeno-associated virus (AAV) vectors. The cellular specificity of reporter expression from enhancer-AAVs is established by molecular profiling after systemic AAV delivery in mouse. Over 30% of enhancer-AAVs produce specific expression in the targeted subclass, including both excitatory and inhibitory subclasses. We present a collection of Parvalbumin (PVALB) enhancer-AAVs that show highly enriched expression not only in cortical PVALB cells but also in some subcortical PVALB populations. Five vectors maintain PVALB-enriched expression in primate neocortex. These results demonstrate how genome-wide open chromatin data mining and cross-species AAV validation can be used to create the next generation of non-species-restricted viral genetic tools.


Asunto(s)
Elementos de Facilitación Genéticos , Regulación de la Expresión Génica , Neocórtex/metabolismo , Animales , Cromatina/genética , Cromatina/metabolismo , Bases de Datos Genéticas , Dependovirus/genética , Enfermedad/genética , Epigénesis Genética , Vectores Genéticos/metabolismo , Genoma , Humanos , Ratones , Neuronas/metabolismo , Parvalbúminas/metabolismo , Primates , Especificidad de la Especie
19.
Neurology ; 95(9): e1244-e1256, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32690786

RESUMEN

OBJECTIVE: To prospectively evaluate safety and efficacy of brain-responsive neurostimulation in adults with medically intractable focal onset seizures (FOS) over 9 years. METHODS: Adults treated with brain-responsive neurostimulation in 2-year feasibility or randomized controlled trials were enrolled in a long-term prospective open label trial (LTT) to assess safety, efficacy, and quality of life (QOL) over an additional 7 years. Safety was assessed as adverse events (AEs), efficacy as median percent change in seizure frequency and responder rate, and QOL with the Quality of Life in Epilepsy (QOLIE-89) inventory. RESULTS: Of 256 patients treated in the initial trials, 230 participated in the LTT. At 9 years, the median percent reduction in seizure frequency was 75% (p < 0.0001, Wilcoxon signed rank), responder rate was 73%, and 35% had a ≥90% reduction in seizure frequency. We found that 18.4% (47 of 256) experienced ≥1 year of seizure freedom, with 62% (29 of 47) seizure-free at the last follow-up and an average seizure-free period of 3.2 years (range 1.04-9.6 years). Overall QOL and epilepsy-targeted and cognitive domains of QOLIE-89 remained significantly improved (p < 0.05). There were no serious AEs related to stimulation, and the sudden unexplained death in epilepsy (SUDEP) rate was significantly lower than predefined comparators (p < 0.05, 1-tailed χ2). CONCLUSIONS: Adjunctive brain-responsive neurostimulation provides significant and sustained reductions in the frequency of FOS with improved QOL. Stimulation was well tolerated; implantation-related AEs were typical of other neurostimulation devices; and SUDEP rates were low. CLINICALTRIALSGOV IDENTIFIER: NCT00572195. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that brain-responsive neurostimulation significantly reduces focal seizures with acceptable safety over 9 years.


Asunto(s)
Epilepsia Refractaria/terapia , Terapia por Estimulación Eléctrica/métodos , Epilepsias Parciales/terapia , Neuroestimuladores Implantables , Calidad de Vida , Adolescente , Adulto , Anciano , Trastorno Depresivo/epidemiología , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/psicología , Epilepsias Parciales/fisiopatología , Epilepsias Parciales/psicología , Femenino , Estudios de Seguimiento , Humanos , Hemorragias Intracraneales/epidemiología , Masculino , Trastornos de la Memoria/epidemiología , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/epidemiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Estado Epiléptico/epidemiología , Muerte Súbita e Inesperada en la Epilepsia/epidemiología , Suicidio/estadística & datos numéricos , Resultado del Tratamiento , Adulto Joven
20.
Epilepsy Behav Case Rep ; 11: 14-17, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30591882

RESUMEN

OBJECTIVES: To examine outcome of bilateral extracranial to intracranial (EC-IC) bypass surgeries for a Down syndrome patient with hard-to-treat epilepsy and moyamoya. MATERIALS AND METHODS: Superficial temporal arteries were anastamosed using an indirect bypass technique to middle cerebral arteries bilaterally to help limit perfusion deficits and seizure controls. RESULTS: Two superficial temporal to middle cerebral artery indirect bypass surgeries were performed within 3 months. Post-revascularization improvements included seizure control, gait, perfusion, wakefulness, language and quality of life. CONCLUSION: In patients with Down syndrome and moyamoya, improvements in seizure control and quality of life may occur with EC-IC bypass procedures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA