Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-35189581

RESUMEN

The binary mixtures of the novel oral anticoagulants (NOACs); Apixaban (APX), Edoxaban tosylate (EDX) and Rivaroxaban (RIV) with the lipid lowering statin; Rosuvastatin calcium were analyzed using a validated HPLC-DAD method. This method was suitable for the quantitative assay of the targeted mixtures in tablets and human plasma. The analysis in dosage form was a stability indicating one where the drugs were separated from possible degradation products arising from applying different stress conditions. For analysis in human plasma, EDX was used as internal standard in APX/ROS and RIV/ROS mixtures, while APX was used as internal standard in EDX/ROS mixture and the method was validated according to FDA regulation for analysis in biological fluids. A ZORBAX Eclipse column C18 (4.6 × 150 mm × 5 µm) was used as stationary phase with a gradient eluting mobile phase composed of acidified water and acetonitrile. The method selectivity was demonstrated by its ability to simultaneously analyze the drugs in presence of possible forced degradation products and dosage form excipients and in presence of plasma interferences (analysis in biological fluid) at a single wavelength (291 nm) with the use of the internal standard. The simplicity of the method emphasizes its capability to analyze the drugs in pharmaceutical preparations and human plasma. This is very important in regular clinical monitoring of the drugs plasma concentrations for cardiovascular patients medicated with either of these combinations, as prophylaxis from stroke, in order to prevent severe bleeding and to achieve optimum dose adjustment.

2.
J AOAC Int ; 94(2): 503-12, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21563684

RESUMEN

A simple, rapid, and selective HPLC-diode array detector method was developed for the simultaneous determination of lidocaine hydrochloride (LD) and cetylpyridinium chloride (CPC) in two combined pharmaceutical formulations. Effective chromatographic separation was achieved on a Zorbax SB-C8 (4.6 x 250 mm, 5 microm particle size) column with gradient elution using a mobile phase composed of 0.05 M phosphoric acid and acetonitrile. The gradient elution started with 25% (v/v) acetonitrile, ramped up linearly to 85% in 5 min, and then was constant until the end of the run. The mobile phase was pumped at a flow rate of 1.2 mL/min. The multiple wavelength detector was set at 214 and 258 nm, and quantification of the analytes was based on measuring their peak areas. The retention times for LD and CPC were about 3.4 and 7.3 min, respectively. The reliability and analytical performance of the proposed HPLC procedure were statistically validated with respect to linearity, range, precision, accuracy, selectivity, robustness, LOD, and LOQ. Calibration curves were linear in the range of 5-200 and 10-400 microg/mL for LD and CPC, respectively, with correlation coefficients > 0.999. The proposed method was proven to be stability-indicating by the resolution of the two analytes from the related substance and potential impurity (2,6-dimethylaniline) as well as from forced-degradation products. The validated HPLC method was extended to the analysis of LD and CPC in two combined oral gel preparations for which the two analytes were successfully resolved from the pharmaceutical adjuvants and quantified with recoveries not less than 97.9%.


Asunto(s)
Cetilpiridinio/química , Cromatografía Líquida de Alta Presión/métodos , Geles/química , Lidocaína/química , Anestésicos Locales/química , Antiinfecciosos Locales/química , Formas de Dosificación , Estabilidad de Medicamentos , Almacenaje de Medicamentos , Estructura Molecular
3.
J AOAC Int ; 93(4): 1192-200, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20922951

RESUMEN

Simple, rapid, and selective RP-HPLC methods with UV detection were developed for simultaneous determination of chlordiazepoxide hydrochloride and mebeverine hydrochloride (Mixture I) and carvedilol and hydrochlorothiazide (Mixture II). The chromatographic separation in both mixtures was achieved by using an RP-C8 (octylsilyl) analytical column. For Mixture I, a mobile phase composed of acetonitrile-0.05 M disodium hydrogen phosphate-triethylamine (50 + 50 + 0.2, v/v/v), pH 2.5, was used; the detector wavelength was 247 nm. For Mixture II, the mobile phase consisted of acetonitrile-0.05 M disodium hydrogen phosphate (50 + 50, v/v), pH 4.0, and the detector was set at 220 nm. Quantification of the analytes was based on measuring their peak areas. Both mixtures were resolved in less than 6 min. The reliability and analytical performance of the proposed HPLC procedures were statistically validated with respect to linearity, range, precision, accuracy, selectivity, robustness, LOD, and LOQ. The linear dynamic ranges were 2.5-150 and 2.5-500 microg/mL for chlordiazepoxide HCI and mebeverine HCI, respectively, and 0.25-200 and 0.25-150 microg/mL for carvedilol and hydrochlorothiazide, respectively. The validated HPLC methods were successfully applied to the analysis of their commercial tablet dosage forms, for which no interfering peaks were encountered from common pharmaceutical adjuvants.


Asunto(s)
Carbazoles/análisis , Clordiazepóxido/análisis , Cromatografía Líquida de Alta Presión/métodos , Hidroclorotiazida/análisis , Fenetilaminas/análisis , Propanolaminas/análisis , Carvedilol , Combinación de Medicamentos , Comprimidos
4.
J AOAC Int ; 91(4): 720-30, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18727529

RESUMEN

Four simple, rapid, sensitive, and selective analytical procedures were developed for determination of mexiletine hydrochloride (MX) and/or its related substance: 2,6-dimethylphenol (DMP). The latter is a synthetic impurity for which a maximum pharmacopeial limit is defined. The first method depends on derivative-ratio spectrophotometry, for which the first-derivative signals of the ratio spectra at 259 nm (Deltalambda = 3 nm) are selected for the determination of MX. The second method is based on the spectrofluorometric measurement of MX in alkaline solution in the presence of 15 mM sodium dodecyl sulfate micellar medium at 292 nm (lambdaEx 260 nm). The third method is based on liquid chromatographic (LC) separation of MX and DMP on an RP-C8 column with a mobile phase consisting of 50 mM Na2HPO4-acetonitrile (60 + 40, adjusted to pH 2.4), and quantification of the analytes is achieved with UV detection at 212 nm based on peak area. The fourth method uses the coupling reaction of DMP with 2,6-dibromo-quinone-4-chlorimide (DBQC) in borate buffer to form an intensely colored product that was spectrophotometrically measured using first-derivative amplitudes at 670 nm (Deltalambda = 6 nm) for the determination of DMP. Different variables affecting each method were carefully investigated and optimized. The reliability and analytical performance of the proposed methods, including linearity, range, precision, accuracy, and detection and quantitation limits, were statistically validated. The first 3 methods were successfully applied for the stability-indicating determination of MX in laboratory-prepared mixtures with DMP, as well as for the determination of MX in capsules. Also, the LC and the DBQC spectrophotometric methods permitted the selective determination of DMP in the presence of a large excess of the parent drug at or near the pharmacopeial limit (0.1-1%).


Asunto(s)
Antiarrítmicos/análisis , Mexiletine/análisis , Xilenos/análisis , Calibración , Cápsulas/análisis , Cromatografía Líquida de Alta Presión , Colorimetría , Estabilidad de Medicamentos , Fluorometría , Indicadores y Reactivos , Espectrofotometría Ultravioleta
5.
Artículo en Inglés | MEDLINE | ID: mdl-29524696

RESUMEN

A direct, eco-friendly, stability-indicating GC method was developed for the determination of Lacosamide (LCM) in tablet dosage forms in presence of its degradation products as well as in human urine in presence of the co-administered drug Zonisamide (ZON). The assay method in tablets was validated according to the ICH guidelines, while the method for determination of LCM in urine was validated according to FDA; Bioanalytical Method Validation guidance. Linear response (r = 0.9998) was observed over the range of 20-280 µg/mL of LCM, with detection and quantitation limits of 5.871 and 19.57 µg/mL, respectively for the tablet assay method. While (r = 0.9999) was observed over the range of 0.5-20 µg/mL of LCM, with detection and quantitation limits of 67 and 233 ng mL-1, respectively for the urine analysis method. Under various stress conditions, the investigation of LCM forced degradation behaviour was carried out. Furthermore, monitoring of the drug in urine followed by construction of its urine profile was done after the administration of 50 mg tablet of LCM to three healthy volunteers so as to prove the ability of the method to be applied in assaying LCM in human urine. The method showed also successful separation of LCM and the co-administered drug ZON in urine. Finally, the greenness of the method was assessed using National Environmental Methods Index label and Eco scale methods.


Asunto(s)
Acetamidas/química , Acetamidas/orina , Cromatografía de Gases/métodos , Acetamidas/farmacocinética , Adulto , Estabilidad de Medicamentos , Tecnología Química Verde , Humanos , Lacosamida , Límite de Detección , Modelos Lineales , Masculino , Reproducibilidad de los Resultados , Comprimidos
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 199: 328-339, 2018 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-29627618

RESUMEN

A green, simple and cost effective chemometric UV-Vis spectrophotometric method has been developed and validated for correcting interferences that arise during conducting biowaiver studies. Chemometric manipulation has been done for enhancing the results of direct absorbance, resulting from very low concentrations (high incidence of background noise interference) of earlier points in the dissolution timing in case of dissolution profile using first and second derivative (D1 & D2) methods and their corresponding Fourier function convoluted methods (D1/FF& D2/FF). The method applied for biowaiver study of Donepezil Hydrochloride (DH) as a representative model was done by comparing two different dosage forms containing 5mg DH per tablet as an application of a developed chemometric method for correcting interferences as well as for the assay and dissolution testing in its tablet dosage form. The results showed that first derivative technique can be used for enhancement of the data in case of low concentration range of DH (1-8µgmL-1) in the three different pH dissolution media which were used to estimate the low drug concentrations dissolved at the early points in the biowaiver study. Furthermore, the results showed similarity in phosphate buffer pH6.8 and dissimilarity in the other 2pH media. The method was validated according to ICH guidelines and USP monograph for both assays (HCl of pH1.2) and dissolution study in 3pH media (HCl of pH1.2, acetate buffer of pH4.5 and phosphate buffer of pH6.8). Finally, the assessment of the method greenness was done using two different assessment techniques: National Environmental Method Index label and Eco scale methods. Both techniques ascertained the greenness of the proposed method.


Asunto(s)
Química Farmacéutica/métodos , Inhibidores de la Colinesterasa/química , Liberación de Fármacos , Indanos/química , Piperidinas/química , Espectrofotometría Ultravioleta/métodos , Comprimidos/química , Bioensayo , Inhibidores de la Colinesterasa/análisis , Donepezilo , Formas de Dosificación , Humanos , Indanos/análisis , Piperidinas/análisis , Solubilidad , Comprimidos/análisis
7.
J Chromatogr Sci ; 50(5): 401-9, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22407005

RESUMEN

The pharmaceutical combination of miconazole nitrate (MZ) and lidocaine hydrochloride (LD) is used in the curative and prophylactic therapy of the oral and gastro-intestinal infections caused by Candida albicans. To the best of our knowledge, no attempts have yet been made to assay this combination by any analytical method. A simple and selective high-performance liquid chromatography-diode array detection (HPLC-DAD) stability-indicating method was developed for the simultaneous determination of MZ and LD in their combined formulation. Effective chromatographic separation was achieved using a Zorbax SB-C8 column with gradient elution of the mobile phase composed of 0.05 M phosphoric acid and acetonitrile. The gradient elution started with 25% (by volume) acetonitrile, ramped up linearly to 65% in 6 min, then kept constant until the end of the run. The mobile phase was pumped at a flow rate of 1 mL/min. The multiple wavelength detector was set at 215 nm and analytes were quantified by measuring their peak areas. The retention times for LD and MZ were approximately 4.1 and 8.4 min, respectively. The reliability and analytical performance of the proposed HPLC procedure were statistically validated with respect to linearity, ranges, precision, accuracy, selectivity, robustness, detection and quantification limits. Calibration curves were linear in the ranges of 5-100 µg/ml for both drugs with correlation coefficients > 0.999. Both drugs were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The proposed method proved to be stability-indicating by the resolution of the two analytes from the related substance and potential impurity (2,6-dimethylaniline) and from the forced-degradation products. The validated HPLC method was applied to the analysis of MZ and LD in the combined oral gel preparation, in which the two analytes were successfully quantified and resolved from the pharmaceutical additives. The proposed method made use of DAD as a tool for peak identity and purity confirmation.


Asunto(s)
Anestésicos Locales/análisis , Antifúngicos/análisis , Cromatografía Líquida de Alta Presión/métodos , Lidocaína/análisis , Miconazol/análisis , Calibración , Formas de Dosificación , Combinación de Medicamentos , Límite de Detección
8.
J Chromatogr Sci ; 50(10): 862-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22677488

RESUMEN

This work describes the development, validation and application of a simple and reliable high-performance liquid chromatography-diode array detection (HPLC-DAD) procedure for the analysis of two pharmaceutical mixtures. The first mixture contains the antihistaminic drug ebastine (EBS) and the famous sympathomimetic drug pseudoephedrine hydrochloride (PSD), and the second mixture is composed of EBS and another sympathomimetic agent, phenylephrine hydrochloride (PHR). Effective chromatographic separation of EBS, PSD and PHR was achieved using a Zorbax SB-C8 (4.6 × 250 mm, 5 µm) column with gradient elution of the mobile phase composed of 0.05M phosphoric acid and acetonitrile. The gradient elution started with 20% (by volume) acetonitrile, ramped up linearly to 90% in 5 min, then kept constant until the end of the run. The mobile phase was pumped at a flow rate of 1 mL/min. The multiple wavelength detector was set at 254 (for EBS and PSD) and 274 nm (for PHR) and quantification of the analytes was based on measuring their peak areas. The retention times for PHR, PSD and EBS were approximately 2.5, 2.9 and 7.1 min, respectively. The reliability and analytical performance of the proposed HPLC procedure were statistically validated with respect to linearity, ranges, precision, accuracy, selectivity, robustness and detection and quantification limits. Calibration curves were linear in the ranges 5-100, 100-1,000 and 10-200 µg/mL for EBS, PSD and PHR, respectively, with correlation coefficients > 0.9996. The validated HPLC method was applied to the analysis of the two pharmaceutical mixtures in laboratory-made tablets in which the analytes were successfully quantified with good recovery values and no interfering peaks were encountered from the inactive ingredients. Finally, the proposed method made use of DAD as a tool for peak identity and purity confirmation.


Asunto(s)
Butirofenonas/análisis , Cromatografía Líquida de Alta Presión/métodos , Fenilefrina/análisis , Piperidinas/análisis , Seudoefedrina/análisis , Combinación de Medicamentos , Antagonistas de los Receptores Histamínicos/análisis , Modelos Lineales , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Simpatomiméticos/análisis , Comprimidos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA