Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Acta Oncol ; 62(8): 923-931, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37488951

RESUMEN

Background: Delivered radiotherapy doses do not exactly match those planned for a course of treatment, largely due to inter-fraction changes in anatomy. In this study, accumulated delivered dose was calculated for a sample of cervical cancer patients, by deformably registering daily cone beam computed tomography (CBCT) images to the planning computed tomography (CT) scan. Planned and accumulated doses were compared for the clinical target volume (CTV), bladder, and rectum.Material and Methods: For 10 patients receiving 45 Gy in 25 fractions of external beam radiotherapy, daily dose distributions were calculated on CBCT. These images were deformed onto the planning CT and the dose was accumulated using Velocity 4.1 (Varian Medical Systems, Palo Alto, USA). The quality of deformable image registration was evaluated visually and by calculating Dice similarity coefficients and mean distance to agreement.Results: V95%>99% was achieved for the primary CTV in 9/10 patients for the planned dose distribution and 7/10 patients for the accumulated dose distribution. Primary CTV coverage by 95% of the prescription dose was reduced in one patient, due to an increase in anterior-posterior separation. Comparison of planned and accumulated dose volume histograms (DVHs) for the bladder and rectum found agreement within 5% at low and intermediate doses, but differences exceeded 20% at higher doses. Direct addition of CBCT DVHs was seen to be a poor estimate for the accumulated DVH at higher doses.Conclusion: Computation of delivered radiotherapy dose that accounts for inter-fraction anatomical changes is important for establishing dose-effect relationships. Updating delivered dose distributions after each fraction would support informed clinical decision making on any potential treatment interventions.


Asunto(s)
Radioterapia de Intensidad Modulada , Tomografía Computarizada de Haz Cónico Espiral , Neoplasias del Cuello Uterino , Femenino , Humanos , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/radioterapia , Dosificación Radioterapéutica , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada por Rayos X , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
2.
BJR Case Rep ; 10(4): uaae020, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38983110

RESUMEN

Reirradiation in recurrent head and neck cancer presents a considerable clinical challenge in radiation oncology. Though technically feasible due to advanced treatment delivery and planning techniques, confidence in delivering such treatments is not universal and patient selection is critical. Radiotherapy planning in reirradiation cases presents a complex technical challenge owing to the often-considerable overlap of dose from a patient's first treatment plan. This technical note describes three clinical case studies of recurrent head and neck cancer and the technical details of how their multidose level reirradiation was planned. Each patient had confirmed recurrence of squamous cell carcinoma and was referred for reirradiation to a previously irradiated area. The clinical details for each patient are provided before a detailed description of the treatment planning methodology is presented, which specifies how to approach such complex overlapping treatment volumes. The patient outcomes are described and a discussion is presented outlining the clinical challenges associated with these cases and the variables that must be accounted for when considering patients for potential reirradiation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA