1.
Strahlenther Onkol ; 195(2): 153-163, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30315483

RESUMEN

OBJECTIVE: This study aimed to assess the reduction in dose to the penile bulb (PB) achieved by MRI-based contouring following drinking and endorectal balloon (ERB) instructions. PATIENTS AND METHODS: A total of 17 prostate cancer patients were treated with intensity-modulated radiation therapy (IMRT) and interstitial brachytherapy (IBT). CT and MRI datasets were acquired back-to-back based on a 65 cm3 air-filled ERB and drinking instructions. After rigid co-registration of the imaging data, the CT-based planning target volume (PTV) used for treatment planning was retrospectively compared to an MRI-based adaptive PTV and the dose to the PB was determined in each case. The adapted PTV encompassed a caudally cropped CT-based PTV which was defined on the basis of the MRI-based prostate contour plus an additional 5 mm safety margin. RESULTS: In the seven-field IMRT treatment plans, the MRI-based adapted PTV achieved mean (Dmean) and maximum (Dmax) doses to the PB which were significantly lower (by 7.6 Gy and 10.9 Gy, respectively; p <0.05) than those of the CT-contoured PTV. For 6 patients, the estimated PB Dmax (seven-field IMRT and IBT) for the adapted PTV was <70 Gy, whereas only 1 patient fulfilled this criterium with the CT-based PTV. CONCLUSION: MRI-based contouring and seven-field IMRT-based treatment planning achieved dose sparing to the PB. Whereas the comparison of MRI and CT contouring only relates to external beam radiotherapy (EBRT) sparing, considering EBRT and IBT shows the improvement in PB sparing for the total treatment.


Asunto(s)
Pene/diagnóstico por imagen , Pene/efectos de la radiación , Neoplasias de la Próstata/radioterapia , Traumatismos por Radiación/prevención & control , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Anciano , Braquiterapia , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estadificación de Neoplasias , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Tomografía Computarizada por Rayos X
2.
Radiologe ; 54(3): 265-70, 2014 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-24522625

RESUMEN

The technical progress and broader indications for cross-sectional imaging continuously increase the number of radiological images to be assessed. However, as the amount of image information and available resources (radiologists) do not increase at the same pace and the standards of radiological interpretation and reporting remain consistently high, radiologists have to rely on computer-based support systems. Novel semantic technologies and software relying on structured ontological knowledge are able to "understand" text and image information and interconnect both. This allows complex database queries with both the input of text and image information to be accomplished. Furthermore, semantic software in combination with automatic detection and segmentation of organs and body regions facilitates personalized supportive information in topographical accordance and generates additional information, such as organ volumes. These technologies promise improvements in workflow; however, great efforts and close cooperation between developers and users still lie ahead.


Asunto(s)
Sistemas de Apoyo a Decisiones Administrativas , Documentación/métodos , Interpretación de Imagen Asistida por Computador/métodos , Almacenamiento y Recuperación de la Información/métodos , Procesamiento de Lenguaje Natural , Reconocimiento de Normas Patrones Automatizadas/métodos , Sistemas de Información Radiológica , Inteligencia Artificial , Terminología como Asunto
3.
Urologe A ; 55(2): 226-31, 2016 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-26450096

RESUMEN

The high incidence of bone metastases of urologic neoplasms and their morbidity, especially of vertebral metastases, requires exact diagnosis and consequent therapy. Conventional radiography plays an important role in the diagnosis of symptomatic bone lesions. Computed tomography can evaluate the stability of metastatic lesions and is indispensable for therapy planning. MRI and PET-CT have the highest diagnostic accuracy for the detection of bone metastases and MRI can evaluate their intra- and extraosseus components. PET-CT, PET-MRI, or SPECT-CT in combination with specific tracers - due to their high specificity and sensitivity - have the potential to replace conventional methods in the future. Conservative treatment basically consists of analgesic therapy, the administration of calcium and vitamin D3 and bisphosphonates or inhibitors of RANKL (denosumab). Moreover radium-223-dichloride can improve overall survival and the time to the first symptomatic skeletal event in castration-resistant prostate cancer patients with bone metastases.


Asunto(s)
Analgésicos/administración & dosificación , Conservadores de la Densidad Ósea/administración & dosificación , Neoplasias de la Columna Vertebral/secundario , Neoplasias de la Columna Vertebral/terapia , Neoplasias Urológicas/diagnóstico por imagen , Neoplasias Urológicas/terapia , Diagnóstico por Imagen/métodos , Medicina Basada en la Evidencia , Humanos , Radioterapia/métodos , Neoplasias de la Columna Vertebral/diagnóstico , Resultado del Tratamiento
4.
Urologe A ; 55(2): 232-40, 2016 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-26678798

RESUMEN

The treatment of bone metastases from urological tumors represents a palliative form of therapy, apart from the resection of solitary metastases from renal cell carcinomas. Due to the high incidence of spinal metastases this can result in clinically significant symptoms and possible complications for patients, such as pain, spinal instability and compression of the spinal canal with corresponding neurological deficits. By the use of targeted diagnostics and induction of radiotherapeutic and/or surgical treatment, for the majority of patients an immediate reduction in pain as well as early mobilization and sometimes even regression of existing neurological deficits and therefore an improved quality of life can be achieved.


Asunto(s)
Cuidados Paliativos/métodos , Neoplasias de la Columna Vertebral/secundario , Neoplasias de la Columna Vertebral/cirugía , Neoplasias Urológicas/diagnóstico por imagen , Neoplasias Urológicas/cirugía , Vertebroplastia/métodos , Medicina Basada en la Evidencia , Humanos , Laminectomía/métodos , Neoplasias de la Columna Vertebral/diagnóstico , Resultado del Tratamiento
5.
Rofo ; 188(2): 179-87, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26815121

RESUMEN

PURPOSE: To assess fields of application and value of dual source computed tomography (DSCT) for diagnostics and therapy in patients with congenital heart disease during their first year of life. Evaluation of image quality, surgical use and radiation exposure of 2nd and 3 rd generation DSCT. MATERIALS AND METHODS: DSCT was applied in 118 cases between January 2012 and October 2014 for diagnostics of congenital heart defects. 2nd generation was used in 91 cases until April 2014 and 3 rd generation in 27 cases during the period thereafter. 3 D reconstructions of the image data were created for clinical diagnostics and planning of interventions. Image quality was assessed using a 4-point-scale. The visibility of the mammary arteries was analyzed, and signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. The usefulness of 3D-reconstructions for surgical planning was rated using a 5-point-scale. Radiation exposure and contrast dye consumption were determined. All cases were analyzed retrospectively. RESULTS: DSCT was successfully used in 118 cases. All image data obtained were interpretable. More than 60 percent of cases did not show any artifacts. The mammary arteries were visible down to the diaphragmatic arch in more than 80 percent of cases. Diagnostic value and surgical benefit were evaluated as "useful" or as "essential" in all cases. Median radiation dose was 0.4 mSv and 0.27 mSv for the 2nd and 3 rd generation DSCT, respectively. Consumption of contrast dye was 2 ml/kg in all cases. CONCLUSION: DSCT is a modern and extremely helpful technique for diagnostics and planning of interventions in patients with complex congenital heart defects. Extracardiac vascular structures in particular can be depicted three-dimensionally at high resolution. The use of iterative reconstruction with 3 rd generation DSCT yielded image quality similar to that of 2nd generation DSCT at considerably reduced radiation exposure level compared to 2nd generation DSCT. 3 rd generation DSCT is a low risk, accurate and extremely fast technique for diagnosing unstable patients with CHD. KEY POINTS: Expanded scope of indications for DSCT in diagnosing critically ill infants. Effective radiation dose is considerably lower than 0.5 mSv. Extremely rapid image acquisitions with high image quality. Possibility of optimized 3D-based surgical planning


Asunto(s)
Cardiopatías Congénitas/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/instrumentación , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Artefactos , Diseño de Equipo , Femenino , Cardiopatías Congénitas/terapia , Humanos , Lactante , Recién Nacido , Masculino , Dosis de Radiación , Estudios Retrospectivos , Sensibilidad y Especificidad
6.
Rofo ; 187(12): 1099-107, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26327669

RESUMEN

PURPOSE: To evaluate automated segmentation and the effects of different manual adjustments regarding left ventricular parameter quantification in cardiac magnetic resonance (MR) data on children and adolescents who have undergone surgical repair of right-sided congenital heart disease (CHD). MATERIALS AND METHODS: Dedicated software (syngo.via, Siemens AG) was used to automatically segment and/or manually adjust the end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), myocardial mass (MM) and ejection fraction (EF) before/after manual apex/base adjustment (ADJ-step 1) and after manual apex/base/myocardial contour adjustment (ADJ-step 2; reference standard). MR data of 40 patients (13.1 ± 3. y, 4 - 17 y) with repaired CHD with decreased pulmonary blood flow (CHD-DPBF) were evaluated. Intra- and inter-rater reliability was determined for 10 randomly selected patients. RESULTS: The software correctly detected the left ventricle in 38/40 (95%) patients. EDV after automated segmentation: 119.1 ± 44.0 ml; after ADJ-step 1: 115.8 ± 9.5 ml; after ADJ-step 2: 116.2 ± 39.4 ml. The corresponding results for ESV were 52.0 ± 18.5/49.6 ± 6.9/49.7 ± 16.4 ml; for SV 67.1 ± 28.5/66.2 ± 25.4/66.5 ± 25. ml; for EF 55.5 ± 7.3/56.7 ± 6.6/56.7 ± 6.3%; for MM 83.7 ± 35.9/76.2 ± 8.3/74.6 ± 27.2 g. Significant differences were found for ESV/MM/EF comparing the automated segmentation results with these after ADJ-step 1 and ADJ-step 2. No significant differences were found when comparing all results of ADJ-step 1 and ADJ-step 2 or when comparing EDV/SV results. Intra- and inter-rater reliability was excellent. The mean time effort was 63.4 ± 6.9 s for the automated segmentation, 74.2 ± 8.9 s for ADJ-step 1 and 269.5 ± 39.4 s for ADJ-step 2. CONCLUSION: Automated left ventricular volumes and function analysis in children and adolescents with surgically treated CHD proved to be feasible with excellent intra- and inter-rater reliability. Automated segmentation with manual apex/base adjustment provided clinically acceptable results. KEY POINTS: Automated left ventricular volume and function analysis in children and adolescents with surgically treated right-sided heart disease is feasible with excellent intra- and inter-rater reliability. Automated segmentation with manual apex/base adjustment provides clinically acceptable results. Additional manual myocardial contour adjustment does not significantly improve the results.


Asunto(s)
Volumen Cardíaco/fisiología , Medios de Contraste , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/cirugía , Ventrículos Cardíacos/anomalías , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Contracción Miocárdica/fisiología , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/diagnóstico , Adolescente , Algoritmos , Niño , Preescolar , Femenino , Cardiopatías Congénitas/diagnóstico , Humanos , Masculino , Miocardio/patología , Estudios Retrospectivos , Programas Informáticos , Disfunción Ventricular Izquierda/fisiopatología
7.
Geburtshilfe Frauenheilkd ; 74(2): 152-156, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24741126

RESUMEN

Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as "uncertain", correct 2 : 1 decisions were classified as "uncertain/readable". In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of "uncertain" fields did not show significant differences. The number of "uncertain" fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of "uncertain/readable" fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens.

8.
Rofo ; 186(2): 130-5, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23929263

RESUMEN

PURPOSE: Many publications describe the use of diffusion-weighted imaging (DWI) in breast MRI. This article addresses the question of when to apply the DWI sequence in the course of the scan protocol. The effect of T1-shortening contrast media (CM) on the ADC values of breast lesions is investigated. MATERIALS AND METHODS: Data were acquired on a 1.5 T scanner. 60 patients with 79 lesions (20 benign, 59 malignant) were included. The DWI sequence (4 mm slice thickness, b-values: 50, 400, 800) was applied before and after CM administration. Before calculating the ADC map, the b50, b400 and b800 series were analyzed concerning lesion displacement. ADC values before and after CM application were compared. RESULTS: The mean lesion size was 1.5 ±â€Š0.8 cm. On the basis of the b50 and b400 measurements, the mean ADC value of benign lesions was 1.89 ± 0.30 × 10-3 mm2/s before and 1.85 ±â€Š0.28 ×10-3 mm2/s after CM administration. The consecutive values for two pure mucinous carcinomas were 1.88 × 10-3 mm2/s and 1.81 × 103 mm2/s and for the remaining malignant lesions 1.00 ±â€Š0.18 × 10-3 mm2/s and 0.88 ±â€Š0.21 × 10-3 mm2. On the basis of the b50, b400 and b800 measurements, the mean ADC value of benign lesions was 1.99 ± 0.37 × 10-3 mm2/s before and 1.97 ±â€Š0.30 × 10-3 mm2/s after CM application, whereas the mean ADC value of the malignant lesions was 0.90 ±â€Š0.14 × 10-3 mm2/s before and 0.80 ±â€Š0.14 × 10-3 mm2/s after CM application. While there was no significant change for benign lesions, the ADC value decrease in post-contrast malignant lesions was highly significant. CONCLUSION: DWI after CM is possible and even leads to slightly better lesion discrimination between benign and malignant. However, further studies need to be performed to verify this. Citation Format: • Janka R, Hammon M, Geppert C et al. Diffusion-Weighted MR Imaging of Benign and Malignant Breast Lesions Before and After Contrast Enhancement. Fortschr Röntgenstr 2014; 186: 130 - 135.


Asunto(s)
Neoplasias de la Mama/patología , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Compuestos Organometálicos/administración & dosificación , Adulto , Medios de Contraste/administración & dosificación , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Rofo ; 186(6): 576-84, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24477504

RESUMEN

PURPOSE: The aim of this study was to evaluate the potential of iterative reconstruction (IR) in chest computed tomography (CT) to reduce radiation exposure. The qualitative and quantitative image quality of standard reconstructions with filtered back projection (FBP) and half dose (HD) chest CT data reconstructed with FBP and IR was assessed. MATERIALS AND METHODS: 52 consecutive patients underwent contrast-enhanced chest CT on a dual-source CT system at 120 kV and automatic exposure control. The tube current was equally split on both tube detector systems. For the HD datasets, only data from one tube detector system was utilized. Thus, FD and HD data was available for each patient with a single scan. Three datasets were reconstructed from the raw data: standard full dose (FD) images applying FBP which served as a reference, HD images applying FBP and IR. Objective image quality analysis was performed by measuring the image noise in tissue and air. The subjective image quality was evaluated by 2 radiologists according to European guidelines. Additional assessment of artifacts, lesion conspicuity and edge sharpness was performed. RESULTS: Image noise did not differ significantly between HD-IR and FD-FBP (p = 0.254) but increased substantially in HD-FBP (p < 0.001). No statistically significant differences were found for the reproduction of anatomical and pathological structures between HD-IR and FD-FBP, subsegmental bronchi and bronchioli. The image quality of HD-FBP was rated inferior because of increased noise. CONCLUSION: A 50 % dose reduction in contrast-enhanced chest CT is feasible without a loss of diagnostic confidence if IR is used for image data reconstruction. Iterative reconstruction is another powerful tool to reduce radiation exposure and can be combined with other dose-saving techniques. KEY POINTS: • Iterative reconstructions allow for image noise and artifact reduction.• Comparable image data can thus be attained even at 50 % radiation dose.• Diagnostic confidence remains unaffected.


Asunto(s)
Filtración , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Radiografía Torácica/métodos , Anciano , Infecciones Bacterianas/diagnóstico por imagen , Disnea/diagnóstico por imagen , Disnea/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Sensibilidad y Especificidad , Enfermedades Torácicas/diagnóstico por imagen , Neoplasias Torácicas/diagnóstico por imagen , Neoplasias Torácicas/patología
10.
Geburtshilfe Frauenheilkd ; 73(2): 148-151, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24771912

RESUMEN

Case Report: We report here on a 58-year-old patient with abnormal findings in the left breast on screening mammography (October 2012). In May 2008 the patient was diagnosed with rectal cancer, subsequently treated by surgical resection followed by radiochemotherapy. In September 2011 the patient was diagnosed with peritoneal cancer. Extravasation of folinic acid occurred during palliative chemotherapy, which was delivered through a surgically implanted port, placed prepectorally on the left side. The patient had not previously undergone breast surgery. The abnormal finding in the left breast was located at the 1-2 o'clock position. The mammogram showed extensive hyperdense nodules with predominantly round, fine granular calcifications. On sonography, the findings presented as a hypoechogenic, inhomogenous, partially diffuse, partly solid, partly cystic mass with individual calcifications and reduced echogenicity in the dorsal aspect. Strong densification of the left breast was found at the corresponding position on palpation. On computed tomography (CT) done during follow-up for rectal cancer, new streaky/pitted densifications were noted in the left breast. Based on the patient's previous history and the results of the breast diagnostics a diagnosis of extensive fat necrosis after folinic acid extravasation was made. No further measures were taken. The patient will continue to be screened using mammography. Conclusion: A good knowledge of the mammographic and sonographic features of fat necrosis can reduce the number of unnecessary biopsies. Careful consideration of the patient's prior medical history is very important in breast diagnostics and may often be decisive for the correct diagnosis.

11.
Geburtshilfe Frauenheilkd ; 73(5): 422-427, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-24771921

RESUMEN

Aim: This prospective clinical study aimed to evaluate whether it would be possible to reduce the rate of re-excisions using CMOS technology, a specimen radiography system (SRS) or digital breast tomosynthesis (DBT) compared to a conventional full field digital mammography (FFDM) system. Material and Method: Between 12/2012 and 2/2013 50 patients were diagnosed with invasive breast cancer (BI-RADS™ 5). After histological verification, all patients underwent breast-conserving therapy with intraoperative imaging using 4 different systems and differing magnifications: 1. Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 lp/mm; 2. BioVision™ (Bioptics, Tucson, AZ, USA), CMOS technology, photodiode array, flat panel, tungsten source, focus 0.05, resolution 50 µm pixel pitch, 12 lp/mm; 3. the Trident™ specimen radiography system (SRS) (Hologic, Bedford, MA, USA), amorphous selenium, tungsten source, focus 0.05, resolution 70 µm pixel pitch, 7.1 lp/mm; 4. tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 lp/mm, angular range 50 degrees, 25 projections, scan time > 20 s, geometry: uniform scanning, reconstruction: filtered back projection. The 600 radiographs were prospectively shown to 3 radiologists. Results: Of the 50 patients with histologically proven breast cancer (BI-RADS™ 6), 39 patients required no further surgical therapy (re-excision) after breast-conserving surgery. A retrospective analysis (n = 11) showed a significant (p < 0.05) increase of sensitivity with the BioVision™, the Trident™ and tomosynthesis compared to the Inspiration™ at a magnification of 1.0 : 2.0 or 1.0 : 1.0 (tomosynthesis) (2.6, 3.3 or 3.6 %), i.e. re-excision would not have been necessary in 2, 3 or 4 patients, respectively, compared to findings obtained with a standard magnification of 1.0 : 1.0. Conclusion: The sensitivity of the BioVision™, the Trident™ and tomosynthesis was significantly (p < 0.05) higher and the rate of re-excisions was reduced compared to FFDM using a conventional detector at a magnification of 2.0 but without zooming.

12.
Med Image Comput Comput Assist Interv ; 15(Pt 1): 438-46, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23285581

RESUMEN

Digital breast tomosynthesis (DBT) emerges as a new 3D modality for breast cancer screening and diagnosis. Like in conventional 2D mammography the breast is scanned in a compressed state. For orientation during surgical planning, e.g., during presurgical ultrasound-guided anchor-wire marking, as well as for improving communication between radiologists and surgeons it is desirable to estimate an uncompressed model of the acquired breast along with a spatial mapping that allows localizing lesions marked in DBT in the uncompressed model. We therefore propose a method for 3D breast decompression and associated lesion mapping from 3D DBT data. The method is entirely data-driven and employs machine learning methods to predict the shape of the uncompressed breast from a DBT input volume. For this purpose a shape space has been constructed from manually annotated uncompressed breast surfaces and shape parameters are predicted by multiple multi-variate Random Forest regression. By exploiting point correspondences between the compressed and uncompressed breasts, lesions identified in DBT can be mapped to approximately corresponding locations in the uncompressed breast model. To this end, a thin-plate spline mapping is employed. Our method features a novel completely data-driven approach to breast shape prediction that does not necessitate prior knowledge about biomechanical properties and parameters of the breast tissue. Instead, a particular deformation behavior (decompression) is learned from annotated shape pairs, compressed and uncompressed, which are obtained from DBT and magnetic resonance image volumes, respectively. On average, shape prediction takes 26s and achieves a surface distance of 15.80 +/- 4.70 mm. The mean localization error for lesion mapping is 22.48 +/- 8.67 mm.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mama/patología , Imagenología Tridimensional/métodos , Algoritmos , Inteligencia Artificial , Fenómenos Biomecánicos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Modelos Estadísticos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Tomografía por Rayos X/métodos
13.
Rofo ; 184(8): 734-9, 2012 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-22618479

RESUMEN

PURPOSE: To introduce automated detection and volumetric segmentation of the spleen in spiral CT scans with the THESEUS-MEDICO software. The consistency between automated volumetry (aV), estimated volume determination (eV) and manual volume segmentation (mV) was evaluated. MATERIALS AND METHODS: Retrospective evaluation of the CAD system based on methods like "marginal space learning" and "boosting algorithms". 3 consecutive spiral CT scans (thoraco-abdominal; portal-venous contrast agent phase; 1 or 5 mm slice thickness) of 15 consecutive lymphoma patients were included. The eV: 30 cm³ + 0.58 (width × length × thickness of the spleen) and the mV as the reference standard were determined by an experienced radiologist. RESULTS: The aV could be performed in all CT scans within 15.2 (± 2.4) seconds. The average splenic volume measured by aV was 268.21 ± 114.67 cm³ compared to 281.58 ± 130.21 cm³ in mV and 268.93 ± 104.60 cm³ in eV. The correlation coefficient was 0.99 (coefficient of determination (R²) = 0.98) for aV and mV, 0.91 (R² = 0.83) for mV and eV and 0.91 (R² = 0.82) for aV and eV. There was an almost perfect correlation of the changes in splenic volume measured with the new aV and mV (0.92; R² = 0.84), mV and eV (0.95; R² = 0.91) and aV and eV (0.83; R² = 0.69) between two time points. CONCLUSION: The automated detection and volumetric segmentation software rapidly provides an accurate measurement of the splenic volume in CT scans. Knowledge about splenic volume and its change between two examinations provides valuable clinical information without effort for the radiologist.


Asunto(s)
Diagnóstico por Computador/métodos , Imagenología Tridimensional/métodos , Linfoma/diagnóstico por imagen , Programas Informáticos , Tomografía Computarizada de Haz Cónico Espiral/métodos , Bazo/diagnóstico por imagen , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Linfoma/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Tamaño de los Órganos , Reconocimiento de Normas Patrones Automatizadas , Estudios Retrospectivos