Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38899376

RESUMEN

Brugada syndrome (BrS) is a cardiac electrophysiological disease with unknown etiology, associated with sudden cardiac death. Symptomatic patients are treated with implanted cardiac defibrillator, but no risk stratification strategy is effective in patients that are at low to medium arrhythmic risk. Cardiac computational modeling is an emerging tool that can be used to verify the hypotheses of pathogenesis and inspire new risk stratification strategies. However, to obtain reliable results computational models must be validated with consistent experimental data. We reviewed the main electrophysiological and structural variables from BrS clinical studies to assess which data could be used to validate a computational approach. Activation delay in the epicardial right ventricular outflow tract is a consistent finding, as well as increased fibrosis and subclinical alterations of right ventricular functional and morphological parameters. The comparison between other electrophysiological variables is hindered by methodological differences between studies, which we commented. We conclude by presenting a recent theory unifying electrophysiological and structural substrate in BrS and illustrate how computational modeling could help translation to risk stratification.

2.
J Cardiovasc Electrophysiol ; 35(5): 965-974, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38477371

RESUMEN

INTRODUCTION: Repolarization dispersion in the right ventricular outflow tract (RVOT) contributes to the type-1 electrocardiographic (ECG) phenotype of Brugada syndrome (BrS), while data on the significance and feasibility of mapping repolarization dispersion in BrS patients are scarce. Moreover, the role of endocardial repolarization dispersion in BrS is poorly investigated. We aimed to assess endocardial repolarization patterns through an automated calculation of activation recovery interval (ARI) estimated on unipolar electrograms (UEGs) in spontaneous type-1 BrS patients and controls; we also investigated the relation between ARI and right ventricle activation time (RVAT), and T-wave peak-to-end interval (Tpe) in BrS patients. METHODS: Patients underwent endocardial high-density electroanatomical mapping (HDEAM); BrS showing an overt type-1 ECG were defined as OType1, while those without (latent type-1 ECG and LType1) received ajmaline infusion. BrS patients only underwent programmed ventricular stimulation (PVS). Data were elaborated to obtain ARI corrected with the Bazett formula (ARIc), while RVAT was derived from activation maps. RESULTS: 39 BrS subjects (24 OType1 and 15 LTtype1) and 4 controls were enrolled. OType1 and post-ajmaline LType1 showed longer mean ARIc than controls (306 ± 27.3 ms and 333.3 ± 16.3 ms vs. 281.7 ± 10.3 ms, p = .05 and p < .001, respectively). Ajmaline induced a significant prolongation of ARIc compared to pre-ajmaline LTtype1 (333.3 ± 16.3 vs. 303.4 ± 20.7 ms, p < .001) and OType1 (306 ± 27.3 ms, p < .001). In patients with type-1 ECG (OTtype1 and post-ajmaline LType1) ARIc correlated with RVAT (r = .34, p = .04) and Tpec (r = .60, p < .001), especially in OType1 subjects (r = .55, p = .008 and r = .65 p < .001, respectively). CONCLUSION: ARIc mapping demonstrates increased endocardial repolarization dispersion in RVOT in BrS. Endocardial ARIc positively correlates with RVAT and Tpec, especially in OType1.


Asunto(s)
Potenciales de Acción , Algoritmos , Síndrome de Brugada , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Endocardio , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Humanos , Masculino , Femenino , Persona de Mediana Edad , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/diagnóstico , Endocardio/fisiopatología , Adulto , Factores de Tiempo , Estudios de Casos y Controles , Ajmalina/administración & dosificación , Automatización , Función Ventricular Derecha , Estimulación Cardíaca Artificial , Anciano , Procesamiento de Señales Asistido por Computador
3.
Wound Repair Regen ; 28(6): 856-866, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32789935

RESUMEN

The aim of this study is to ascertain whether the simultaneous measurement of hemoglobin O2 saturation (StO2 ) and dimension of venous leg ulcers (VLU) by near infrared spectroscopy (NIRS) imaging can predict the healing course with protocols employing a conventional treatment alone or in combination with hyperbaric oxygen therapy (HBOT). NIRS 2D images of wound region were obtained in 81 patients with hard-to-heal VLU that had been assigned, in a randomized controlled clinical trial, to the following protocols: 30 HBOT sessions, adjunctive to the conventional therapy, either twice daily over 3 weeks (group A) or once daily over 6 weeks (group B), and conventional therapy without HBOT (group C). Seventy-three patients completed the study with a total of 511 NIRS images being analyzed. At the end of treatment, wound area was significantly smaller in all three groups. However, at the 3-week mark the wound area reduction tended to be less evident in group A than in the other groups. This trend continued up to the 6-week end-point when a significantly greater area reduction was found with group B (65.5%) and group C (56.8%) compared to group A (29.7%) (P < .01). Furthermore, a higher incidence of complete healing was noted with group B (20%) than with group A (4.5%) and group C (3.8%). When using a final wound reduction in excess of 40% to distinguish healing from nonhealing ulcers, it was found that only the former present NIRS StO2 values abating over the study period both at center and edge of lesions. In conclusion, NIRS analysis of StO2 and wound area can predict the healing course of VLU. Adjunctive HBOT significantly facilitates VLU healing compared to the conventional treatment alone. This positive action, however, becomes manifest only with a longer and less intensive treatment schedule.


Asunto(s)
Vendajes de Compresión , Hemoglobinas/metabolismo , Oxigenoterapia Hiperbárica/métodos , Espectroscopía Infrarroja Corta/métodos , Úlcera Varicosa/terapia , Cicatrización de Heridas/fisiología , Anciano , Biomarcadores/sangre , Femenino , Humanos , Masculino , Consumo de Oxígeno , Resultado del Tratamiento , Úlcera Varicosa/sangre
4.
Bioelectromagnetics ; 39(5): 414-422, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29709072

RESUMEN

The use of wireless communication devices, such as tablets or laptops, is increasing among children. Only a few studies assess specific energy absorption rate (SAR) due to exposure from wireless-enabled tablets and laptops, in particular with Worldwide Interoperability for Microwave Access (WiMax) technology. This paper reports the estimation of the interaction between an E-shaped patch antenna (3.5 GHz) and human models, by means of finite-difference time-domain (FDTD) method. Specifically, four different human models (young adult male, young adult female, pre-teenager female, male child) in different exposure conditions (antenna at different distances from the human model, in different positions, and orientations) were considered and whole-body, 10 and 1 g local SAR and magnetic field value (Bmax) were evaluated. From our results, in some worst-case scenarios involving male and female children's exposure, the maximum radiofrequency energy absorption (hot spots) is located in more sensitive organs such as eye, genitals, and breast. Bioelectromagnetics. 39:414-422, 2018. © 2018 Wiley Periodicals, Inc.


Asunto(s)
Simulación por Computador , Computadores , Microondas , Modelos Biológicos , Exposición a la Radiación , Tecnología Inalámbrica/instrumentación , Niño , Femenino , Humanos , Masculino , Órganos en Riesgo , Adulto Joven
5.
Crit Rev Biomed Eng ; 42(2): 109-35, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25403875

RESUMEN

Magnetic resonance imaging and magnetic resonance spectroscopy are noninvasive diagnostic techniques based on the phenomenon of nuclear magnetic resonance. Radiofrequency coils are key components in both the transmission and receiving phases of magnetic resonance systems. Transmitter coils have to produce a highly homogeneous alternating field in a wide field of view, whereas receiver coils have to maximize signal detection while minimizing noise. Development of modern magnetic resonance coils often is based on numerical methods for simulating and predicting coil performance. Numerical methods allows the behavior of the coil in the presence of realistic loads to be simulated and the coil's efficiency at high magnetic fields to be investigated. After being built, coils have to be characterized in the laboratory to optimize their setting and performance by extracting several quality indices. Successively, coils performance has to be evaluated in a scanner using standardized image quality parameters with phantom and human experiments. This article reviews the principles of radiofrequency coils, coil performance parameters, and their estimation methods using simulations, workbench, and magnetic resonance experiments. Finally, an overview of future developments in radiofrequency coils technology is included.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/instrumentación , Diseño de Equipo , Análisis de Elementos Finitos , Relación Señal-Ruido
6.
Artículo en Inglés | MEDLINE | ID: mdl-35805332

RESUMEN

Magnetic resonance (MR) systems are used in academic research laboratories and industrial research fields, besides representing one of the most important imaging modalities in clinical radiology. This technology does not use ionizing radiation, but it cannot be considered without risks. These risks are associated with the working principle of the technique, which mainly involves static magnetic fields that continuously increase-namely, the radiofrequency (RF) field and spatial magnetic field gradient. To prevent electromagnetic hazards, the EU and ICNIRP have defined workers' exposure limits. Several studies that assess health risks for workers and patients of diagnostic MR are reported in the literature, but data on workers' risk evaluation using nuclear MR (NMR) spectroscopy are very poor. Therefore, the aim of this research is the risk assessment of an NMR environment, paying particular attention to workers with active implantable medical devices (AIMDs). Our perspective study consisted of the measurement of the static magnetic field around a 300 MHz (7 T) NMR research spectrometer and the computation of the electric field induced by the movements of an operator. None of the calculated exposure parameters exceeded the threshold limits imposed by legislation for protection against short-term effects of acute occupational exposure, but our results revealed that the level of exposure exceeded the action level threshold limit for workers with AIMD during the execution of tasks requiring the closest proximity to the spectrometer. Moreover, the strong dependence of the induced electric field results from the walking speed models is shown. This case study represents a snapshot of the NMR risk assessment with the specific goal to increase the interest in the safety of NMR environments.


Asunto(s)
Campos Electromagnéticos , Exposición Profesional , Campos Electromagnéticos/efectos adversos , Humanos , Campos Magnéticos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Exposición Profesional/análisis , Ondas de Radio
7.
Int J Occup Saf Ergon ; 28(1): 76-85, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32276568

RESUMEN

The purpose of this study is to analyze exposure to the time-varying magnetic field caused by worker movements in a 3-T clinical magnetic resonance imaging (MRI) scanner. Measurements of the static magnetic field (B) in the proximity of the MRI scanner were performed to create a detailed map of the spatial gradient of B, in order to indicate the areas at high risk of exposure. Moreover, a personal exposure recording system was used in order to analyze and compare exposure to the static magnetic field during different routine procedures in MRI. We found that for all of the performed work activities, exposure was compliant with International Commission on Non-Ionizing Radiation Protection levels. However, our findings confirm that there is great variability of exposure between different workers and suggest the importance of performing personal exposure measurements and of detailed knowledge of the magnetic field spatial distribution.


Asunto(s)
Campos Magnéticos , Exposición Profesional , Campos Electromagnéticos/efectos adversos , Humanos , Imagen por Resonancia Magnética , Movimiento , Exposición Profesional/análisis
8.
Ital J Dermatol Venerol ; 157(2): 187-194, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34498454

RESUMEN

BACKGROUND: Lower limb ulcers not responding to standard treatments after 8 weeks are defined as chronic wounds, and they are a significant medical problem. Blue light (410-430 nm) proved to be effective in treating wounds, but there is a lack of data on chronic wounds in clinical practice. The aim of the study was to determine if blue light photobiomodulation with EmoLED (Emoled Srl, Sesto Fiorentino, Florence, Italy) medical device in addition to standard of care is more effective compared to standard of care alone in promoting re-epithelialization of chronic wounds of lower limbs in 10 weeks. METHODS: Ninety patients affected by multiple or large area ulcers were enrolled. To minimize all variabilities, each patient has been used as control of himself. Primary endpoint was the comparison of the re-epithelialization rate expressed as a percentage of the difference between the initial and final area. Secondary endpoints were: treatment safety, pain reduction, wound area reduction trend over time, healing rate. RESULTS: At week 10, the wounds treated with EmoLED in addition to standard care showed a smaller residual wound area compared to the wounds treated with standard of care alone: 42.1% vs. 63.4% (P=0.029). The difference is particularly evident in venous leg ulcers, 33.3% vs. 60.1% (P=0.007). 17 treated wounds and 12 controls showed complete healing at week 10. Patients showed a significant reduction in pain (P=2×10-7). CONCLUSIONS: Blue light treatment in addition to standard of care accelerates consistently the re-epithelialization rate of chronic wounds, especially venous leg ulcers and increases the chances of total wound healing in 10 weeks.


Asunto(s)
Terapia por Luz de Baja Intensidad , Úlcera Varicosa , Humanos , Dolor , Úlcera , Úlcera Varicosa/radioterapia , Cicatrización de Heridas
9.
Med Biol Eng Comput ; 60(2): 297-320, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34586563

RESUMEN

Magnetic resonance imaging (MRI) is one of the most-used diagnostic imaging methods worldwide. There are ∼50,000 MRI scanners worldwide each of which involves a minimum of five workers from different disciplines who spend their working days around MRI scanners. This review analyzes the state of the art of literature about the several aspects of the occupational exposure to electromagnetic fields (EMF) in MRI: regulations, literature studies on biological effects, and health surveillance are addressed here in detail, along with a summary of the main approaches for exposure assessment. The original research papers published from 2013 to 2021 in international peer-reviewed journals, in the English language, are analyzed, together with documents published by legislative bodies. The key points for each topic are identified and described together with useful tips for precise safeguarding of MRI operators, in terms of exposure assessment, studies on biological effects, and health surveillance.


Asunto(s)
Campos Electromagnéticos , Exposición Profesional , Campos Electromagnéticos/efectos adversos , Humanos , Campos Magnéticos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Exposición Profesional/análisis , Medición de Riesgo
10.
MAGMA ; 24(6): 323-30, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21892733

RESUMEN

OBJECT: Staff operating in the environment of magnetic resonance imaging (MRI) scanners are exposed daily to static magnetic fields (MFs). To protect workers several guidelines are present in literature reporting exposure limits values expressed in terms of magnetic flux density or induced current density. We present here a novel tool for estimating the induced current density due to worker movement in the MR environment. MATERIALS AND METHODS: A Matlab script was created to estimate the induced current density J due to operator movements along a chosen walking path. RESULTS: The induced current density associated with any worker's movements during MR procedures is dependent on the walking speed and on the spatial gradient fields associated with a specific path. Some examples of possible worker paths were considered here for a 3 T MR scanner and a maximum value of 160 cm/s walking speed. CONCLUSION: This tool permits one to find exposure level for specific worker walking path and speed; it can be used as assessment tool in any MRI centre and for workers safety education. It is valid for any kind of commercial scanner because it requires only the knowledge of the MR scanner room map with isogauss lines.


Asunto(s)
Campos Electromagnéticos , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Exposición Profesional/análisis , Monitoreo de Radiación/métodos , Conductividad Eléctrica , Seguridad de Equipos , Humanos , Movimiento , Exposición Profesional/prevención & control , Protección Radiológica/métodos
11.
Artículo en Inglés | MEDLINE | ID: mdl-33530365

RESUMEN

The recent development of millimeter-wave (mmW) technologies, such as the fifth-generation (5G) network, comes with concerns related to user exposure. A quite large number of dosimetry studies above 6 GHz have been conducted, with the main purpose being to establish the correlation between different dosimetric parameters and the skin surface temperature elevation. However, the dosimetric studies from 28 GHz user equipment using different voxel models have not been comprehensively discussed yet. In this study, we used the finite-difference time-domain (FDTD) method for the estimation of the absorption of radiofrequency (RF) energy from a microstrip patch antenna array (28 GHz) in different human models. Specifically, we analyzed different exposure conditions simulating three real common scenarios (a phone call scenario, message writing scenario, and browsing scenario) regarding the use of smartphones/tablets by four different individuals (adult male and female, child male and female). From the results of Absorbed Power Density (Sab), it is possible to conclude that all the considered exposure scenarios comply with the safety limits, both for adult and children models. However, the high values of the local Specific Absorption Rate (SAR) in the superficial tissues and the slight differences in its distribution between adults and children suggest the need for further and more detailed analysis.


Asunto(s)
Campos Electromagnéticos , Ondas de Radio , Adulto , Niño , Campos Electromagnéticos/efectos adversos , Femenino , Humanos , Masculino , Ondas de Radio/efectos adversos , Radiometría
12.
J Neurosci Methods ; 362: 109317, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34380051

RESUMEN

BACKGROUND: Disentangling physiological noise and signal of interest is a major issue when evaluating BOLD-signal changes in response to breath holding. Currently-adopted approaches for retrospective noise correction are general-purpose, and have non-negligible effects in studies on hypercapnic challenges. NEW METHOD: We provide a novel approach to the analysis of specific and non-specific BOLD-signal changes related to end-tidal CO2 (PETCO2) in breath-hold fMRI studies. Multiple-order nonlinear predictors for PETCO2 model a region-dependent nonlinear input-output relationship hypothesized in literature and possibly playing a crucial role in disentangling noise. We explore Retrospective Image-based Correction (RETROICOR) effects on the estimated BOLD response, applying our analysis both with and without RETROICOR and analyzing the linear and non-linear correlation between PETCO2 and RETROICOR regressors. RESULTS: The RETROICOR model of noise related to respiratory activity correlated with PETCO2 both linearly and non-linearly. The correction affected the shape of the estimated BOLD response to hypercapnia but allowed to discard spurious activity in ventricles and white matter. Activation clusters were best detected using non-linear components in the BOLD response model. COMPARISON WITH EXISTING METHOD: We evaluated the side-effects of standard physiological noise correction procedure, tailoring our analysis on challenging understudied brainstem and subcortical regions. Our novel approach allowed to characterize delays and non-linearities in BOLD response. CONCLUSIONS: RETROICOR successfully avoided false positives, still broadly affecting the estimated non-linear BOLD responses. Non-linearities in the model better explained CO2-related BOLD signal fluctuations. The necessity to modify the standard procedure for physiological-noise correction in breath-hold studies was addressed, stating its crucial importance.


Asunto(s)
Dióxido de Carbono , Sustancia Blanca , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Tronco Encefálico , Contencion de la Respiración , Imagen por Resonancia Magnética , Estudios Retrospectivos
13.
J Appl Physiol (1985) ; 130(2): 298-307, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33300854

RESUMEN

We demonstrated that changes in CO2 values cause oscillations in the cortical activity in δ-and α-bands. The analysis of the regional field power (RFP) showed evidence that different cortical areas respond with different time delays to CO2 challenges. An opposite behavior was found for the end-tidal O2. We suppose that the different cortical time delays likely expresse specific ascending pathways to the cortex, generated by chemoreceptor nuclei in the brain stem. Although the brain stem is in charge of the automatic control of ventilation, the cortex is involved in the voluntary control of breathing but also receives inputs from the brain stem, which influences the perception of breathing, the arousal state and sleep architecture in conditions of hypoxia/hypercapnia. We evaluated in 11 healthy subjects the effects of breath hold (BH; 30 s of apneas and 30 s of normal breathing) and BH-related CO2/O2 changes on electroencephalogram (EEG) global field power (GFP) and RFP in nine different areas (3 rostrocaudal sections: anterior, central, and posterior; and 3 sagittal sections: left, middle, and right) in the δ- and α-bands by cross correlation analysis. No significant differences were observed in GFP or RFP when comparing free breathing (FB) with the BH task. Within the BH task, the shift from apnea to normal ventilation was accompanied by an increase in the δ-power and a decrease in the α-power. The end-tidal pressure of CO2 ([Formula: see text]) was positively correlated with the δ-band and negatively with the α- band with a positive time shift, whereas an opposite behavior was found for the end-tidal pressure of O2 ([Formula: see text]). Notably, the time shift between [Formula: see text] / [Formula: see text] signals and cortical activity at RFP was heterogenous and seemed to follow a hierarchical activation, with the δ-band responding earlier than the α-band. Overall, these findings suggest that the effect of BH on the cortex may follow specific ascending pathways from the brain stem and be related to chemoreflex stimulation.NEW & NOTEWORTHY We demonstrated that the end tidal CO2 oscillation causes oscillations of delta and alpha bands. The analysis of the regional field power showed that different cortical areas respond with different time delays to CO2 challenges. An opposite behavior was found for the end-tidal O2. We can suppose that the different cortical time delay response likely expresses specific ascending pathways to the cortex generated by chemoreceptor nuclei in the brainstem.


Asunto(s)
Contencion de la Respiración , Dióxido de Carbono , Electroencefalografía , Voluntarios Sanos , Humanos , Hipercapnia , Respiración
14.
Med Phys ; 37(10): 5361-9, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21089771

RESUMEN

PURPOSE: Hyperpolarized carbon-13 magnetic resonance spectroscopy is a novel and powerful tool for exploring the metabolic state of tissue, but a number of technological problems still limit this technology and need innovative solutions. In particular, the low molar concentration of derivate metabolites give rise to low signal-to-noise ratio (SNR), which makes the design and development of dedicated RF coils a task of fundamental importance. In this article, the authors describe the simulation and the design of a dedicated 13C surface coil for cardiac metabolism assessment in pig models. METHODS: A SNR model for a circular loop is presented and applied to the design of a 13C coil which guarantees the desired field-of-view and provides high SNR with a good penetration in deep sample regions. The coil resistance was calculated from Ohm's law and the magnetic field pattern was calculated using Biot-Savart law, while the sample induced resistance was calculated using a numerical finite-difference time-domain algorithm. Successively, a prototype of the coil was built and tested on the workbench and by acquisition of MR data. RESULTS: The comparison of SNR-vs-depth profiles between the theoretical SNR model and the experimental SNR extracted from the phantom chemical shift image (CSI) showed the accuracy of the authors' model. Moreover, the authors demonstrated the use of the coil for the acquisition of a CSI of a hyperpolarized [1-13C] pyruvate phantom. CONCLUSIONS: The results demonstrated the design trade-offs to successfully design a dedicated coil for cardiac imaging in the pig with hyperpolarized 13C by developing a SNR model which allows the prediction of the coil performance. This approach can be employed for deriving SNR formulations for coil with more complex geometries.


Asunto(s)
Isótopos de Carbono , Espectroscopía de Resonancia Magnética/instrumentación , Algoritmos , Animales , Fenómenos Biofísicos , Diseño de Equipo , Espectroscopía de Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/estadística & datos numéricos , Porcinos
15.
IEEE Trans Neural Syst Rehabil Eng ; 28(5): 1216-1225, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32191895

RESUMEN

The characterization of brain cortical activity in heart-failure patients affected by Cheyne-Stokes Respiration might provide relevant information about the mechanism underlying this pathology. Central autonomic network is gaining increasing attention for its role in the regulation of breathing and cardiac functions. In this scenario, evaluating changes in cortical connectivity associated with Cheyne-Stokes Respiration may be of interest in the study of specific brain-activity related to such disease. Nonetheless, the inter subject variability, the temporal dynamics of Central-Apnea/Hyperpnea cycles and the limitations of clinical setups lead to different methodological challenges. To this aim, we present a framework for the assessment of cortico-cortical interactions from Electroencephalographic signals acquired using low-density caps and block-design paradigms, arising from endogenous triggers. The framework combines ICA-decomposition, unsupervised clustering, MVAR modelling and a permutation-bootstrap strategy for evaluating significant connectivity differences between conditions. A common network, lateralized towards the left hemisphere, was depicted across 8 patients exhibiting Cheyne-Stokes Respiration patterns during acquisitions. Significant differences in connectivity at the group level were observed based on patients' ventilatory condition. Interactions were significantly higher during hyperpnea periods with respect to central apneas and occurred mainly in the delta band. Opposite-sign differences were observed for higher frequencies (i.e. beta, low-gamma).


Asunto(s)
Insuficiencia Cardíaca , Apnea Central del Sueño , Encéfalo/fisiología , Respiración de Cheyne-Stokes , Electroencefalografía , Humanos , Respiración
16.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 808-811, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31946018

RESUMEN

A full characterization of the physiological behavior of human central chemoreceptors through fMRI is crucial to understand the pathophysiology of central abnormal breathing patterns. In this scenario, physiological noise and activity of interest may be naturally correlated. Here, we examined the adequacy of linear-modelling-based retrospective physiological noise correction for studies of the central breathing control. We focused on the relationship between a nonlinear model of BOLD response, hypothesized to describe neuronal specific activity, and noise modelled by correction algorithms. Analyses were performed on fMRI acquisitions from healthy subjects during a breath hold task. A general linear model including static nonlinearities in the response to end-tidal CO2 was applied to data preprocessed both with and without physiological noise correction. Relations between physiological noise and PETCO2 were explored both with linear and nonlinear measures. Lastly, parametric maps of noise spatial distribution were extracted. Our results evidenced that correction algorithms based on linear modelling remove components that are both linearly and nonlinearly related to end-tidal CO2, whereas uncorrected data showed spurious activations in regions outside gray matter. Thus, despite a correction step is fundamental, these algorithms are shown to be over-conservative approaches to noise correction and need to be adapted to the specific purpose.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Artefactos , Encéfalo , Mapeo Encefálico , Humanos , Estudios Retrospectivos
17.
Semin Arthritis Rheum ; 48(5): 867-873, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30205980

RESUMEN

OBJECTIVES: Systemic sclerosis (SSc) causes functional and structural microcirculatory dysfunction, affecting also distal extremities. Optical Near-InfraRed Spectroscopy (NIRS) of blood HbO2 saturation (stO2) is able to evaluate O2 delivery/consumption balance in the explored tissue. The NIRS-sensitive camera non-invasively detects stO2 values in superficial tissues, automatically generating 2D-imaging maps in real time. We aimed at testing whether NIRS hand imaging may evaluate peripheral microcirculatory dysfunction and its spatial heterogeneity in SSc patients compared to controls. METHODS: Forty SSc patients (aged 55.1 ±â€¯15.6 years) and twenty-one healthy controls (aged 54.3 ±â€¯14.5years, p = 0.89) were studied by palmar hand NIRS-2D imaging. A blood pressure cuff was applied to the forearm and 3 min ischemia was induced. Images were acquired at basal conditions and every 10 seconds during 3 minutes of ischemia and 5 minutes of reperfusion. Five regions of interest were positioned on each fingertip, from the second to the fifth finger and one on the thenar eminence. RESULTS: A significant difference was found between controls and SSc patients in basal stO2 (84.3 ±â€¯7.5 vs. 75.4 ±â€¯10.9%, p < 0.001), minimum stO2 (65.2 ±â€¯8.0 vs. 53.4 ±â€¯10.1%, p < 0.001) and time to maximum stO2 during hyperemia (63 ±â€¯38 vs. 85 ±â€¯49 s, p < 0.05). Among clinical characteristics, anti-Scl70 antibody positivity, digital ulcers history and smoke exposure affected NIRS parameters, as well as sildenafil and statins therapy. Conversely, no significant differences were found in NIRS-2D values between different nailfold-videocapillaroscopy patterns. CONCLUSION: NIRS-2D imaging is a simple, automated tool to non-invasively detect regional microcirculatory impairment in SSc, which seems to add significant functional information to the morphological picture of nailfold-videocapillaroscopy.


Asunto(s)
Mano/diagnóstico por imagen , Microcirculación/fisiología , Consumo de Oxígeno/fisiología , Esclerodermia Sistémica/fisiopatología , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Mano/irrigación sanguínea , Humanos , Masculino , Persona de Mediana Edad , Esclerodermia Sistémica/diagnóstico por imagen , Espectroscopía Infrarroja Corta/métodos
18.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 4795-4798, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31946934

RESUMEN

The relationships between brain functions and the respiratory system are complex. Disentangling brain activity related to CO2 changes from nonspecific vasoreactivity is a challenge when studying brain activity involved in the control of breathing with fMRI. In this work, we analyzed a dose dependent relationship between arterial CO2 levels and brain response. To accomplish this goal, we developed a gas administration protocol, together with multi-subject ICA and specific nonlinear post-processing analysis. Our results highlighted a supra-linear response to CO2 challenges in brainstem, thalamus and putamen. Results were discussed in the light of current knowledge about the central respiratory network.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Mapeo Encefálico , Dióxido de Carbono/metabolismo , Humanos , Respiración
19.
J Clin Med ; 8(2)2019 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-30791407

RESUMEN

Obesity is recognized as a major public health issue, as it is linked to the increased risk of severe pathological conditions. The aim of this pilot study is to evaluate the relations between adiposity (and biophysical characteristics) and temperature profiles under thermoneutral conditions in normal and overweight females, investigating the potential role of heat production/dissipation alteration in obesity. We used Infrared Thermography (IRT) to evaluate the thermogenic response to a metabolic stimulus performed with an oral glucose tolerance test (OGTT). Thermographic images of the right hand and of the central abdomen (regions of interests) were obtained basally and during the oral glucose tolerance test (3 h OGTT with the ingestion of 75 g of oral glucose) in normal and overweight females. Regional temperature vs BMI, % of body fat and abdominal skinfold were statistically compared between two groups. The study showed that mean abdominal temperature was significantly greater in lean than overweight participants (34.11 ± 0.70 °C compared with 32.92 ± 1.24 °C, p < 0.05). Mean hand temperature was significantly greater in overweight than lean subjects (31.87 ± 3.06 °C compared with 28.22 ± 3.11 °C, p < 0.05). We observed differences in temperature profiles during OGTT between lean and overweight subjects: The overweight individuals depict a flat response as compared to the physiological rise observed in lean individuals. This observed difference in thermal pattern suggests an energy rate imbalance towards nutrients storage of the overweight subjects.

20.
Ann Work Expo Health ; 63(3): 328-336, 2019 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-30852618

RESUMEN

Concerning the occupational exposure in magnetic resonance imaging (MRI) facilities, the worker behavior in the magnetic resonance (MR) room is of such particular importance that there is the need for a simple but reliable method to alert the worker of the highest magnetic field exposure. Here, we describe a quantitative analysis of occupational exposure in different MRI working environments: in particular, we present a field measurement method integrated with a software tool for an accurate mapping of the fringe field in the proximity of the magnetic resonance bore. Three illustrative assessment studies are finally presented, compared and discussed, considering an example of a realistic path followed by an MRI worker during the daily procedure. The results show that the basic restrictions set by ICNIRP can be exceeded during standard procedure even in 1.5 T scanners. Using the described simplified metrics, it is possible to introduce behavioral rules on how to move around an MRI room that could be more useful than a numerical limit to aid magnetic field risk mitigation strategies.


Asunto(s)
Imagen por Resonancia Magnética/efectos adversos , Exposición Profesional/análisis , Monitoreo de Radiación/métodos , Campos Electromagnéticos/efectos adversos , Humanos , Proyectos Piloto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA