Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Anesthesiology ; 134(4): 562-576, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33635945

RESUMEN

BACKGROUND: Protective ventilation may improve outcomes after major surgery. However, in the context of one-lung ventilation, such a strategy is incompletely defined. The authors hypothesized that a putative one-lung protective ventilation regimen would be independently associated with decreased odds of pulmonary complications after thoracic surgery. METHODS: The authors merged Society of Thoracic Surgeons Database and Multicenter Perioperative Outcomes Group intraoperative data for lung resection procedures using one-lung ventilation across five institutions from 2012 to 2016. They defined one-lung protective ventilation as the combination of both median tidal volume 5 ml/kg or lower predicted body weight and positive end-expiratory pressure 5 cm H2O or greater. The primary outcome was a composite of 30-day major postoperative pulmonary complications. RESULTS: A total of 3,232 cases were available for analysis. Tidal volumes decreased modestly during the study period (6.7 to 6.0 ml/kg; P < 0.001), and positive end-expiratory pressure increased from 4 to 5 cm H2O (P < 0.001). Despite increasing adoption of a "protective ventilation" strategy (5.7% in 2012 vs. 17.9% in 2016), the prevalence of pulmonary complications did not change significantly (11.4 to 15.7%; P = 0.147). In a propensity score matched cohort (381 matched pairs), protective ventilation (mean tidal volume 6.4 vs. 4.4 ml/kg) was not associated with a reduction in pulmonary complications (adjusted odds ratio, 0.86; 95% CI, 0.56 to 1.32). In an unmatched cohort, the authors were unable to define a specific alternative combination of positive end-expiratory pressure and tidal volume that was associated with decreased risk of pulmonary complications. CONCLUSIONS: In this multicenter retrospective observational analysis of patients undergoing one-lung ventilation during thoracic surgery, the authors did not detect an independent association between a low tidal volume lung-protective ventilation regimen and a composite of postoperative pulmonary complications.


Asunto(s)
Pulmón/cirugía , Ventilación Unipulmonar/métodos , Complicaciones Posoperatorias/epidemiología , Volumen de Ventilación Pulmonar/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
2.
Anesthesiology ; 130(4): 530-540, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30601218

RESUMEN

WHAT WE ALREADY KNOW ABOUT THIS TOPIC: Electromagnetic interference from monopolar electrosurgery may disrupt implantable cardioverter defibrillators.Current management recommendations by the American Society of Anesthesiologists and Heart Rhythm Society are based on expert clinical opinion since there is a paucity of data regarding the risk of electromagnetic interference to implantable cardioverter defibrillators during surgery. WHAT THIS ARTICLE TELLS US THAT IS NEW: With protocolized electrosurgery dispersive electrode positioning in patients with implantable cardioverter defibrillators, the risk of clinically meaningful electromagnetic interference was 7% in above-the-umbilicus noncardiac surgery and 0% in below-the-umbilicus surgery. In cardiac surgery, clinically meaningful electromagnetic interference with use of an underbody dispersive electrode was 29%.Despite protocolized dispersive electrode positioning, the risk of electromagnetic interference in above-the-umbilicus surgery is high, supporting recommendations to suspend antitachycardia therapy when monopolar electrosurgery is used above the umbilicus.With protocolized dispersive electrode positioning, the risk of electromagnetic interference in below-the-umbilicus surgery is negligible, implying that suspending antitachycardia therapy might be unnecessary in these cases.With an underbody dispersive electrode, the risk of electromagnetic interference in cardiac surgery is high. BACKGROUND: The goal of this study was to determine the occurrence of intraoperative electromagnetic interference from monopolar electrosurgery in patients with an implantable cardioverter defibrillator undergoing surgery. A protocolized approach was used to position the dispersive electrode. METHODS: This was a prospective cohort study including 144 patients with implantable cardioverter defibrillators undergoing surgery between May 2012 and September 2016 at an academic medical center. The primary objectives were to determine the occurrences of electromagnetic interference and clinically meaningful electromagnetic interference (interference that would have resulted in delivery of inappropriate antitachycardia therapy had the antitachycardia therapy not been programmed off) in noncardiac surgeries above the umbilicus, noncardiac surgeries at or below the umbilicus, and cardiac surgeries with the use of an underbody dispersive electrode. RESULTS: The risks of electromagnetic interference and clinically meaningful electromagnetic interference were 14 of 70 (20%) and 5 of 70 (7%) in above-the-umbilicus surgery, 1 of 40 (2.5%) and 0 of 40 (0%) in below-the-umbilicus surgery, and 23 of 34 (68%) and 10 of 34 (29%) in cardiac surgery. Had conservative programming strategies intended to reduce the risk of inappropriate antitachycardia therapy been employed, the occurrence of clinically meaningful electromagnetic interference would have been 2 of 70 (2.9%) in above-the-umbilicus surgery and 3 of 34 (8.8%) in cardiac surgery. CONCLUSIONS: Despite protocolized dispersive electrode positioning, the risks of electromagnetic interference and clinically meaningful electromagnetic interference with surgery above the umbilicus were high, supporting published recommendations to suspend antitachycardia therapy whenever monopolar electrosurgery is used above the umbilicus. For surgery below the umbilicus, these risks were negligible, implying that suspending antitachycardia therapy is likely unnecessary in these patients. For cardiac surgery, the risks of electromagnetic interference and clinically meaningful electromagnetic interference with an underbody dispersive electrode were high. Conservative programming strategies would not have eliminated the risk of clinically meaningful electromagnetic interference in either noncardiac surgery above the umbilicus or cardiac surgery.


Asunto(s)
Desfibriladores Implantables/normas , Electrodos Implantados/normas , Fenómenos Electromagnéticos , Electrocirugia/normas , Marcapaso Artificial/normas , Adulto , Anciano , Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Electrocirugia/instrumentación , Electrocirugia/métodos , Femenino , Cardiopatías/fisiopatología , Cardiopatías/terapia , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos
3.
Surgery ; 165(1): 158-165, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30415870

RESUMEN

BACKGROUND: Sudden massive release of serotonin, histamine, kallikrein, and bradykinin is postulated to cause an intraoperative carcinoid crisis. The exact roles of each of these possible agents, however, remain unknown. Optimal treatment will require an improved understanding of the pathophysiology of the carcinoid crisis. METHODS: Carcinoid patients with liver metastases undergoing elective abdominal operations were studied prospectively, using intraoperative, transesophageal echocardiography, pulmonary artery catheterization, and intraoperative blood collection. Serotonin, histamine, kallikrein, and bradykinin levels were analyzed by enzyme-linked immunosorbent assay. RESULTS: Of 46 patients studied, 16 had intraoperative hypotensive crises. Preincision serotonin levels were greater in patients who had crises (1,064 vs 453 ng/mL, P = .0064). Preincision hormone profiles were otherwise diverse. Cardiac function on transesophageal echocardiography during the crisis was normal, but intracardiac hypovolemia was observed consistently. Pulmonary artery pressure decreased during crises (P = .025). Linear regression of preincision serotonin levels showed a positive relationship with mid-crisis cardiac index (r = 0.73, P = .017) and a negative relationship with systemic vascular resistance (r=-0.61, P = .015). There were no statistically significant increases of serotonin, histamine, kallikrein, or bradykinin levels during the crises. CONCLUSION: The pathophysiology of carcinoid crisis appears consistent with distributive shock. Hormonal secretion from carcinoid tumors varies widely, but increased preincision serotonin levels correlate with crises and with hemodynamic parameters during the crises. Statistically significant increases of serotonin, histamine, kallikrein, or bradykinin during the crises were not observed.


Asunto(s)
Hipotensión/fisiopatología , Hipovolemia/fisiopatología , Síndrome Carcinoide Maligno/fisiopatología , Arteria Pulmonar/fisiopatología , Serotonina/sangre , Bradiquinina/sangre , Tumor Carcinoide/fisiopatología , Tumor Carcinoide/cirugía , Ecocardiografía Transesofágica , Femenino , Histamina/sangre , Humanos , Neoplasias Intestinales/fisiopatología , Neoplasias Intestinales/cirugía , Complicaciones Intraoperatorias , Calicreínas/sangre , Neoplasias Hepáticas/secundario , Neoplasias Pulmonares/fisiopatología , Neoplasias Pulmonares/cirugía , Masculino , Síndrome Carcinoide Maligno/sangre , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos
4.
Neurol Clin ; 24(1): 1-21, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16443127

RESUMEN

Cerebral ischemia results in a rapid depletion of energy stores that triggers a complex cascade of cellular events such as cellular depolarization and Ca2+ influx, resulting in excitotoxic cell death. The critical determinant of severity of brain injury is the duration and severity of the ischemic insult and early restoration of CBF. Induced therapeutic hypothermia following CA is the only strategy that has demonstrated improvement in outcomes in prospective, randomized clinical trials. Although pharmacologic neuro-protection has been disappointing thus far in a variety of experimental animal models, further research efforts are directed at using some agents that demonstrate marginal or moderate efficacy in combination with hypothermia. Although the signal transduction pathways and intracellular molecular events during cerebral ischemia and reperfusion are complex, potential therapeutic neuroprotective strategies hold promise for the future.


Asunto(s)
Isquemia Encefálica/patología , Encéfalo/irrigación sanguínea , Encéfalo/patología , Apoptosis/fisiología , Ácido Aspártico/metabolismo , Temperatura Corporal , Encéfalo/metabolismo , Isquemia Encefálica/tratamiento farmacológico , Isquemia Encefálica/metabolismo , Canales de Calcio/metabolismo , Citocinas/metabolismo , Dopamina/metabolismo , Espacio Extracelular/metabolismo , Homocisteína/metabolismo , Humanos , Necrosis/patología , Neuronas/metabolismo , Neuronas/patología , Óxido Nítrico/metabolismo , Norepinefrina/metabolismo , Receptores AMPA/metabolismo , Receptores de N-Metil-D-Aspartato/metabolismo
5.
Anesthesiol Clin ; 31(2): 479-89, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23711654

RESUMEN

The array of diagnostic and therapeutic procedures performed in the cardiology electrophysiology laboratory has expanded rapidly. Increasingly more facilities and cardiologists are performing these procedures, and the number of patients for whom these procedures are indicated is expanding. Because of the complexity of the procedures and associated patient comorbidity, anesthesia providers will become more involved in providing care in the electrophysiology laboratory. Therefore, anesthesia providers must be prepared to handle a broad range of case complexity. This article addresses the implications of providing anesthesia safely and effectively in the electrophysiology laboratory.


Asunto(s)
Anestesia/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Ablación por Catéter , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas/efectos adversos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Humanos , Marcapaso Artificial
6.
J Anesth ; 16(3): 229-37, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-14517646
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA