Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 37(3): 312-20, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24164640

RESUMEN

AIMS: There is little consensus on optimal atrioventricular (AV) and ventricular-to-ventricular (VV) intervals in cardiac resynchronization therapy (CRT). The aim of this study was to examine a novel combination of Doppler echocardiography (DE) and three-dimensional echocardiography (3DE) for individualized AV- and VV-interval optimization compared to conventional electrocardiogram (ECG) optimization. METHODS: In this double-blind, randomized controlled trial, 77 patients (male: 57, age: 68 ± 10 years) with severely reduced ejection fraction (EF), New York Heart Association (NYHA) class III or IV, and wide QRS complex (>120 ms) have been included. Patients were randomized to either AV- and VV-interval optimization using DE and 3DE (group 1, n = 39) or ECG (group 2, n = 38). 3DE was performed in all patients for the evaluation of left ventricular (LV) dimensions, EF and systolic dyssynchrony index (SDI), and NYHA class obtained before CRT and after 3 months. Primary endpoint of the study was clinical response to CRT, defined as a reduction of NYHA class by ≥1 score. Secondary endpoints were change of EF, LV volumes, and SDI. RESULTS: There were significantly more responders in group 1 (82%) than in group 2 (58%, P = 0.021). Similarly, group 1 showed a larger increase in EF (7.0 ± 6.0% vs 3.4 ± 5.6%, P = 0.015) and a more pronounced reduction of SDI (-4.5 ± 5.9% vs -1.5 ± 5.6%, P = 0.039) than group 2. CONCLUSION: Compared with conventional ECG optimization, this novel echocardiographic optimization protocol resulted in a significantly higher response rate, improved LV systolic function, and may be used to select the optimal AV and VV intervals in CRT.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Ecocardiografía Doppler/métodos , Ecocardiografía Tridimensional/métodos , Electrocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/prevención & control , Anciano , Método Doble Ciego , Femenino , Humanos , Masculino , Pronóstico , Resultado del Tratamiento
2.
PLoS One ; 7(2): e30964, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22319598

RESUMEN

BACKGROUND: Post-implantation therapies to optimize cardiac resynchronization therapy (CRT) focus on adjustments of the atrio-ventricular (AV) delay and ventricular-to-ventricular (VV) interval. However, there is little consensus on how to achieve best resynchronization with these parameters. The aim of this study was to examine a novel combination of doppler echocardiography (DE) and three-dimensional echocardiography (3DE) for individualized optimization of device based AV delays and VV intervals compared to empiric programming. METHODS: 25 recipients of CRT (male: 56%, mean age: 67 years) were included in this study. Ejection fraction (EF), the primary outcome parameter, and left ventricular (LV) dimensions were evaluated by 3DE before CRT (baseline), after AV delay optimization while pacing the ventricles simultaneously (empiric VV interval programming) and after individualized VV interval optimization. For AV delay optimization aortic velocity time integral (AoVTI) was examined in eight different AV delays, and the AV delay with the highest AoVTI was programmed. For individualized VV interval optimization 3DE full-volume datasets of the left ventricle were obtained and analyzed to derive a systolic dyssynchrony index (SDI), calculated from the dispersion of time to minimal regional volume for all 16 LV segments. Consecutively, SDI was evaluated in six different VV intervals (including LV or right ventricular preactivation), and the VV interval with the lowest SDI was programmed (individualized optimization). RESULTS: EF increased from baseline 23±7% to 30±8 (p<0.001) after AV delay optimization and to 32±8% (p<0.05) after individualized optimization with an associated decrease of end-systolic volume from a baseline of 138±60 ml to 115±42 ml (p<0.001). Moreover, individualized optimization significantly reduced SDI from a baseline of 14.3±5.5% to 6.1±2.6% (p<0.001). CONCLUSIONS: Compared with empiric programming of biventricular pacemakers, individualized echocardiographic optimization with the integration of 3-dimensional indices into the optimization protocol acutely improved LV systolic function and decreased ESV and can be used to select the optimal AV delay and VV interval in CRT.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Ecocardiografía Doppler/métodos , Ecocardiografía Tridimensional/métodos , Hemodinámica , Anciano , Terapia de Resincronización Cardíaca/normas , Humanos , Masculino , Métodos , Volumen Sistólico , Disfunción Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA