Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 319
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Diabetologia ; 67(2): 236-245, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38041737

RESUMEN

People living with diabetes have many medical devices available to assist with disease management. A critical aspect that must be considered is how systems for continuous glucose monitoring and insulin pumps communicate with each other and how the data generated by these devices can be downloaded, integrated, presented and used. Not only is interoperability associated with practical challenges, but also devices must adhere to all aspects of regulatory and legal frameworks. Key issues around interoperability in terms of data ownership, privacy and the limitations of interoperability include where the responsibility/liability for device and data interoperability lies and the need for standard data-sharing protocols to allow the seamless integration of data from different sources. There is a need for standardised protocols for the open and transparent handling of data and secure integration of data into electronic health records. Here, we discuss the current status of interoperability in medical devices and data used in diabetes therapy, as well as regulatory and legal issues surrounding both device and data interoperability, focusing on Europe (including the UK) and the USA. We also discuss a potential future landscape in which a clear and transparent framework for interoperability and data handling also fulfils the needs of people living with diabetes and healthcare professionals.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus , Humanos , Glucemia , Diabetes Mellitus/tratamiento farmacológico , Registros Electrónicos de Salud , Reino Unido
2.
Diabet Med ; 41(3): e15261, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38009855

RESUMEN

AIMS: To analyse predictors for continuous glucose monitoring (CGM) use in people with diabetes aged ≥60 years using insulin therapy and to assess the rates of CGM use during recent years (2019-2021). RESEARCH DESIGN AND METHODS: Prospective study including 6849 individuals with diabetes and insulin therapy (type 2 diabetes: n = 5320; type 1 diabetes: n = 1529) aged ≥60 years. Data from 129 treatment centres were retrieved from the Diabetes Prospective Follow-up Registry (DPV) in March 2023. RESULTS: Sensor use in individuals aged ≥60 years has increased in type 1 (2019: 28%, 2020: 39%, 2021: 45%) and type 2 diabetes (2019: 10%, 2020: 16%, 2021: 18%). Predictors for sensor use in older individuals with type 1 diabetes are younger age and CSII use (p < 0.001). Predictors in older individuals with type 2 diabetes are younger age, longer diabetes duration, higher BMI and CSII use (p < 0.001). CONCLUSIONS: CGM has become more common in older adults with diabetes and will presumably increase further. Age is a predictor for sensor use in older adults with diabetes. Age-related physical barriers and insufficient usability of devices, lack of interest in technologies, but possibly also effects of prejudice on the grounds of age may contribute to this finding.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Humanos , Anciano , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Hipoglucemiantes/uso terapéutico , Estudios Prospectivos , Glucemia , Automonitorización de la Glucosa Sanguínea , Monitoreo Continuo de Glucosa , Estudios de Seguimiento , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Sistema de Registros
3.
Diabetologia ; 66(1): 3-22, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36198829

RESUMEN

A technological solution for the management of diabetes in people who require intensive insulin therapy has been sought for decades. The last 10 years have seen substantial growth in devices that can be integrated into clinical care. Driven by the availability of reliable systems for continuous glucose monitoring, we have entered an era in which insulin delivery through insulin pumps can be modulated based on sensor glucose data. Over the past few years, regulatory approval of the first automated insulin delivery (AID) systems has been granted, and these systems have been adopted into clinical care. Additionally, a community of people living with type 1 diabetes has created its own systems using a do-it-yourself approach by using products commercialised for independent use. With several AID systems in development, some of which are anticipated to be granted regulatory approval in the near future, the joint Diabetes Technology Working Group of the European Association for the Study of Diabetes and the American Diabetes Association has created this consensus report. We provide a review of the current landscape of AID systems, with a particular focus on their safety. We conclude with a series of recommended targeted actions. This is the fourth in a series of reports issued by this working group. The working group was jointly commissioned by the executives of both organisations to write the first statement on insulin pumps, which was published in 2015. The original authoring group was comprised by three nominated members of the American Diabetes Association and three nominated members of the European Association for the Study of Diabetes. Additional authors have been added to the group to increase diversity and range of expertise. Each organisation has provided a similar internal review process for each manuscript prior to submission for editorial review by the two journals. Harmonisation of editorial and substantial modifications has occurred at both levels. The members of the group have selected the subject of each statement and submitted the selection to both organisations for confirmation.


Asunto(s)
Diabetes Mellitus , Insulina , Humanos , Estados Unidos , Insulina/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus/tratamiento farmacológico , Tecnología
4.
Endocr Pract ; 29(8): 670-677, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37098370

RESUMEN

OBJECTIVE: To review the current status of practical knowledge related to insulin-associated lipohypertrophy (LH) - an accumulation of fatty subcutaneous nodules commonly caused by repeated injections and/or infusions of insulin into the same site. METHODS: Review of published literature with additional contributions from leading multidisciplinary experts with the emphasis on clinical aspects including pathophysiology, clinical and economic consequences, diagnosis, prevention and treatment. RESULTS: LH is the most common dermatologic complication of insulin therapy. Risk factors for the development of lipohypertrophy include repeated delivery of large amounts of insulin into the same location over time, repeated injection trauma to the skin and subcutaneous tissue, and multiple injections using the same needle. Subcutaneous insulin injection in skin areas with lipohypertrophy is associated with reduced pain; however, this problem can interfere with insulin absorption, thereby increasing the likelihood of glucose variability, hypo- and hyperglycemia when a site is changed. Modern visualization technology of the subcutaneous space with ultrasound can demonstrate lipohypertrophy early in the course of its development. CONCLUSIONS: The physiological and psychological consequences of developing insulin lipohypertrophy can be prevented and treated with education focusing on insulin injection techniques.


Asunto(s)
Diabetes Mellitus Tipo 1 , Lipodistrofia , Humanos , Insulina , Diabetes Mellitus Tipo 1/complicaciones , Insulina Regular Humana/uso terapéutico , Factores de Riesgo , Lipodistrofia/inducido químicamente , Lipodistrofia/complicaciones
5.
Diabet Med ; 39(5): e14798, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35092035

RESUMEN

AIMS: Oral glucose tolerance tests (oGTT) are widely used for the diagnosis of diabetes. It is well known that the reproducibility of oGTT is poor and that a number of factors have an impact on the outcome of this diagnostic test. It appears as if one aspect, the oral glucose solution (OGS) used has not achieved much attention. Very little is published about this, despite the fact that apparently most often not a pure and freshly prepared glucose solution is used but a ready-to-use solution prepared by a (pharmaceutical) company. METHODS: A literature search was performed to find respective publications. RESULTS: It appears as if no or only a small number of not adequately designed clinical-experimental studies have been performed comparing different OGS head-to-head. CONCLUSIONS: The composition of such OGS, including the excipients added to improve taste and smell, can have an impact on blood glucose increase after drinking the given OGS. Such factors can also have an impact on endogenous insulin secretion. If significant differences in the blood glucose excursions exist depending on which OGS is used, this calls for the use of a standardized OGS in oGTT to have a comparable outcome everywhere.


Asunto(s)
Glucemia , Diabetes Mellitus , Glucosa , Prueba de Tolerancia a la Glucosa , Humanos , Insulina , Reproducibilidad de los Resultados
6.
Diabet Med ; 38(2): e14467, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33230860

RESUMEN

AIMS: Comprehensive knowledge, specific skills and data-analysis competences are prerequisites for the successful use of continuous glucose monitoring (CGM) systems. SPECTRUM is a structured training programme for real-time CGM (rtCGM) consisting of a web-based introduction and six group sessions of 90 min each. The 'CGM-TRAIN study' evaluated the efficacy and acceptance of SPECTRUM and rtCGM systems among adults with insulin therapy. METHODS: Participants (n = 120) were recruited from 10 German diabetes centres in which they were treated under usual care conditions. Outcome measures were rtCGM knowledge, practical skills, satisfaction with the training programme, satisfaction and acceptance of rtCGM system and glycaemic control. Data were collected at study entry, after training completion and at 6-month follow-up. RESULTS: All participants were diagnosed with type 1 diabetes (56% women, mean age 42.4 ± 13.4 years, diabetes duration 21.6 ± 11.6 years), 110 participants completed the course. After training completion, rtCGM-specific knowledge had improved by 43% (scale: 0-40 points) from 21.2 ± 7.6 to 30.4 ± 4.5 points; p < 0.001. The knowledge-level persisted until follow-up (29.4 ± 4.5). Participants were able to master nearly all the practical requirements of the technology. In addition, rtCGM was highly accepted, and participants were motivated to use their systems continuously. HbA1c improved slightly from 61 ± 14 mmol/mol (7.7 ± 1.3%) before training to 60 ± 14 mmol/mol (7.6 ± 1.3%) at follow-up (p = 0.04). The training programme itself was favourably rated by participants. CONCLUSIONS: Under usual out-patient daily care conditions, the training programme SPECTRUM improved knowledge and skills about rtCGM in adults with type 1 diabetes. This was associated with a reduced HbA1c , high satisfaction and acceptance of rtCGM (Clinical Trials Registry no.: DRKS00014380).


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/terapia , Conocimientos, Actitudes y Práctica en Salud , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Educación del Paciente como Asunto/métodos , Satisfacción del Paciente , Adulto , Diabetes Mellitus Tipo 1/metabolismo , Manejo de la Enfermedad , Femenino , Hemoglobina Glucada/metabolismo , Control Glucémico , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio , Estudios Prospectivos , Autocuidado/métodos , Automanejo/educación
7.
Diabetologia ; 63(2): 229-241, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31802144

RESUMEN

Digital health technology, especially digital and health applications ('apps'), have been developing rapidly to help people manage their diabetes. Numerous health-related apps provided on smartphones and other wireless devices are available to support people with diabetes who need to adopt either lifestyle interventions or medication adjustments in response to glucose-monitoring data. However, regulations and guidelines have not caught up with the burgeoning field to standardise how mobile health apps are reviewed and monitored for patient safety and clinical validity. The available evidence on the safety and effectiveness of mobile health apps, especially for diabetes, remains limited. The European Association for the Study of Diabetes (EASD) and the American Diabetes Association (ADA) have therefore conducted a joint review of the current landscape of available diabetes digital health technology (only stand-alone diabetes apps, as opposed to those that are integral to a regulated medical device, such as insulin pumps, continuous glucose monitoring systems, and automated insulin delivery systems) and practices of regulatory authorities and organisations. We found that, across the USA and Europe, mobile apps intended to manage health and wellness are largely unregulated unless they meet the definition of medical devices for therapeutic and/or diagnostic purposes. International organisations, including the International Medical Device Regulators Forum and WHO, have made strides in classifying different types of digital health technology and integrating digital health technology into the field of medical devices. As the diabetes digital health field continues to develop and become more fully integrated into everyday life, we wish to ensure that it is based on the best evidence for safety and efficacy. As a result, we bring to light several issues that the diabetes community, including regulatory authorities, policymakers, professional organisations, researchers, people with diabetes and healthcare professionals, needs to address to ensure that diabetes health technology can meet its full potential. These issues range from inadequate evidence on app accuracy and clinical validity to lack of training provision, poor interoperability and standardisation, and insufficient data security. We conclude with a series of recommended actions to resolve some of these shortcomings.


Asunto(s)
Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/métodos , Consenso , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamiento farmacológico , Europa (Continente) , Humanos , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Aplicaciones Móviles , Teléfono Inteligente , Estados Unidos
8.
Contact Dermatitis ; 82(2): 101-104, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31463958

RESUMEN

BACKGROUND: Some patients with diabetes develop skin reactions when using systems for continuous glucose monitoring (CGM) or insulin pumps. Regular usage and long wearing periods lead not only to skin irritation, but also to allergic contact dermatitis. It has been shown that allergens such as isobornyl acrylate (IBOA) are present in the plastic housing and also in the adhesives of medical devices used for diabetes treatment. OBJECTIVES: To evaluate the IBOA content of all parts of a newly introduced, implanted CGM system (Eversense) to check whether this can be an alternative for IBOA-sensitized patients. METHODS: The IBOA content of the implanted sensor itself (n = 3), the transmitter (n = 3), and two different types of adhesive (white adhesive [n = 4] and clear adhesive [n = 4]) was measured by gas chromatography/mass spectrometry. RESULTS: No IBOA was found in any part of this CGM system. CONCLUSIONS: Patients with an IBOA allergy may be able to use this implanted CGM system.


Asunto(s)
Acrilatos/efectos adversos , Automonitorización de la Glucosa Sanguínea/efectos adversos , Canfanos/efectos adversos , Dermatitis Alérgica por Contacto/etiología , Sistemas de Infusión de Insulina/efectos adversos , Adhesivos/efectos adversos , Alérgenos/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Manejo de la Enfermedad , Equipos y Suministros , Femenino , Humanos , Masculino
9.
Sensors (Basel) ; 20(19)2020 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-32993132

RESUMEN

Atrial fibrillation (AF) is the most common arrhythmia and has a major impact on morbidity and mortality; however, detection of asymptomatic AF is challenging. This study sims to evaluate the sensitivity and specificity of non-invasive AF detection by a medical wearable. In this observational trial, patients with AF admitted to a hospital carried the wearable and an ECG Holter (control) in parallel over a period of 24 h, while not in a physically restricted condition. The wearable with a tight-fit upper armband employs a photoplethysmography technology to determine pulse rates and inter-beat intervals. Different algorithms (including a deep neural network) were applied to five-minute periods photoplethysmography datasets for the detection of AF. A total of 2306 h of parallel recording time could be obtained in 102 patients; 1781 h (77.2%) were automatically interpretable by an algorithm. Sensitivity to detect AF was 95.2% and specificity 92.5% (area under the receiver operating characteristics curve (AUC) 0.97). Usage of deep neural network improved the sensitivity of AF detection by 0.8% (96.0%) and specificity by 6.5% (99.0%) (AUC 0.98). Detection of AF by means of a wearable is feasible in hospitalized but physically active patients. Employing a deep neural network enables reliable and continuous monitoring of AF.


Asunto(s)
Fibrilación Atrial , Dispositivos Electrónicos Vestibles , Anciano , Anciano de 80 o más Años , Algoritmos , Fibrilación Atrial/diagnóstico , Electrocardiografía , Femenino , Humanos , Pacientes Internos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Función Ventricular Izquierda
10.
Lancet ; 391(10128): 1367-1377, 2018 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-29459019

RESUMEN

BACKGROUND: The effectiveness of real-time continuous glucose monitoring (rtCGM) in avoidance of hypoglycaemia among high-risk individuals with type 1 diabetes treated with multiple daily insulin injections (MDI) is unknown. We aimed to ascertain whether the incidence and severity of hypoglycaemia can be reduced through use of rtCGM in these individuals. METHODS: The HypoDE study was a 6-month, multicentre, open-label, parallel, randomised controlled trial done at 12 diabetes practices in Germany. Eligible participants had type 1 diabetes and a history of impaired hypoglycaemia awareness or severe hypoglycaemia during the previous year. All participants wore a masked rtCGM system for 28 days and were then randomly assigned to 26 weeks of unmasked rtCGM (Dexcom G5 Mobile system) or to the control group (continuing with self-monitoring of blood glucose). Block randomisation with 1:1 allocation was done centrally, with the study site as the stratifying variable. Masking of participants and study sites was not possible. Control participants wore a masked rtCGM system during the follow-up phase (weeks 22-26). The primary outcome was the baseline-adjusted number of hypoglycaemic events (defined as glucose ≤3·0 mmol/L for ≥20 min) during the follow-up phase. The full dataset analysis comprised participants who wore the rtCGM system during the baseline and follow-up phases. The intention-to-treat analysis comprised all randomised participants. This trial is registered with ClinicalTrials.gov, number NCT02671968. FINDINGS: Between March 4, 2016, and Jan 12, 2017, 149 participants were randomly assigned (n=74 to the control group; n=75 to the rtCGM group) and 141 completed the follow-up phase (n=66 in the control group, n=75 in the rtCGM group). The mean number of hypoglycaemic events per 28 days among participants in the rtCGM group was reduced from 10·8 (SD 10·0) to 3·5 (4·7); reductions among control participants were negligible (from 14·4 [12·4] to 13·7 [11·6]). Incidence of hypoglycaemic events decreased by 72% for participants in the rtCGM group (incidence rate ratio 0·28 [95% CI 0·20-0·39], p<0·0001). 18 serious adverse events were reported: seven in the control group, ten in the rtCGM group, and one before randomisation. No event was considered to be related to the investigational device. INTERPRETATION: Usage of rtCGM reduced the number of hypoglycaemic events in individuals with type 1 diabetes treated by MDI and with impaired hypoglycaemia awareness or severe hypoglycaemia. FUNDING: Dexcom Inc.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Adulto , Concienciación , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/sangre , Esquema de Medicación , Femenino , Estudios de Seguimiento , Humanos , Hipoglucemia/sangre , Hipoglucemia/psicología , Hipoglucemiantes/uso terapéutico , Inyecciones Subcutáneas , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad
11.
Horm Metab Res ; 50(10): 728-734, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30216941

RESUMEN

Measurement of HbA1c is an essential laboratory measure for the follow-up and therapy decision-making in patients with diabetes. HbA1c is one of the measurands in laboratory medicine that have to be successfully checked according to the criteria of the guidelines of the German Medical Association (Rili-BAEK) in external quality assurance using the reference method value concept, when applied in patient care. The allowed deviation of ±18% in external quality assessment (EQA) and ± 10% in internal quality control has been ultimately met by virtually all the different manufacturers and methods. However, such broad limits for permissible deviations are not suitable in view of medical requirements in patient care. The low-level acceptance criteria also depends on the previously used EQA materials used in Germany. In fact, HbA1c measurement results that are imprecisely measured or come from incorrectly calibrated devices are difficult to identify. With implementation of unprocessed fresh EDTA blood, the situation has changed. Until now systems with unit use reagents for point-of-care testing (POCT) of HbA1c are not mandatory to participate in EQA schemes in Germany. This paper outlines why there was a need to narrow the acceptance limits listed within the Rili-BAEK for HbA1c's internal (to ± 3%) and external (to ± 8%) quality controls in EQA schemes for Germany, which will take place after a transition period in the next years. Higher quality in HbA1c measurements will help to avoid misdiagnosis of diabetes as well as potential over- or undertreatment of patients at risk for diabetes.


Asunto(s)
Diabetes Mellitus/diagnóstico , Hemoglobina Glucada/análisis , Hemoglobina Glucada/normas , Diabetes Mellitus/sangre , Diabetes Mellitus/terapia , Estudios de Seguimiento , Alemania , Humanos , Pruebas en el Punto de Atención , Control de Calidad , Estándares de Referencia
12.
Diabetologia ; 60(12): 2319-2328, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29067486

RESUMEN

The first systems for continuous glucose monitoring (CGM) became available over 15 years ago. Many then believed CGM would revolutionise the use of intensive insulin therapy in diabetes; however, progress towards that vision has been gradual. Although increasing, the proportion of individuals using CGM rather than conventional systems for self-monitoring of blood glucose on a daily basis is still low in most parts of the world. Barriers to uptake include cost, measurement reliability (particularly with earlier-generation systems), human factors issues, lack of a standardised format for displaying results and uncertainty on how best to use CGM data to make therapeutic decisions. This scientific statement makes recommendations for systemic improvements in clinical use and regulatory (pre- and postmarketing) handling of CGM devices. The aim is to improve safety and efficacy in order to support the advancement of the technology in achieving its potential to improve quality of life and health outcomes for more people with diabetes.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/efectos de los fármacos , Glucosa/metabolismo , Humanos , Hipoglucemiantes/uso terapéutico , Insulina , Calidad de Vida , Reproducibilidad de los Resultados , Estados Unidos
13.
MMW Fortschr Med ; 158 Suppl 5: 19-27, 2016 08.
Artículo en Alemán | MEDLINE | ID: mdl-27565486

RESUMEN

BACKGROUND: Biosimilar medicinal products have been in use in the European Union since 2006. In September 2014, insulin glargine (LY IGlar) was approved as a long-acting insulin analogue. In accordance with EMA (European Medicines Agency) and FDA (Food and Drug Administration) guidelines, analytical, preclinical and clinical studies were submitted demonstrating drug safety and biosimilarity of LY IGlar with the reference insulin glargine (IGlar). METHOD: In a review article, study data collected in the clinical development of LY IGlar are summarized. RESULTS: A program of Phase 1 studies investigated whether the criteria for bioequivalence were met. Based on these standards, the pharmacokinetic and pharmacodynamic properties of the two insulins were shown to be similar. The clinical comparability of LY IGlar versus IGlar was demonstrated in two Phase 3 studies in patients with type 1 and type 2 diabetes. The tolerability profiles of LY IGlar and IGlar were similar in these studies; no significant differences were observed in the rate of adverse events, hypoglycemic events or immunogenicity. CONCLUSION: The results of these studies show that LY IGlar represents an alternative treatment option for basal insulin therapy in patients with type 1 and type 2 diabetes because its efficacy and tolerability is similar to that of IGlar.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Insulina Glargina/uso terapéutico , Biosimilares Farmacéuticos , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico
14.
Diabetologia ; 58(5): 862-70, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25784563

RESUMEN

Insulin pump therapy, also known as continuous subcutaneous insulin infusion (CSII), is an important and evolving form of insulin delivery, which is mainly used for people with type 1 diabetes. However, even with modern insulin pumps, errors of insulin infusion can occur due to pump failure, insulin infusion set (IIS) blockage, infusion site problems, insulin stability issues, user error or a combination of these. Users are therefore exposed to significant and potentially fatal hazards: interruption of insulin infusion can result in hyperglycaemia and ketoacidosis; conversely, delivery of excessive insulin can cause severe hypoglycaemia. Nevertheless, the available evidence on the safety and efficacy of CSII remains limited. The European Association for the Study of Diabetes (EASD) and American Diabetes Association (ADA) have therefore joined forces to review the systems in place for evaluating the safety of pumps from a clinical perspective. We found that useful information held by the manufacturing companies is not currently shared in a sufficiently transparent manner. Public availability of adverse event (AE) reports on the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database is potentially a rich source of safety information but is insufficiently utilised due to the current configuration of the system; the comparable database in Europe (European Databank on Medical Devices, EUDAMED) is not publicly accessible. Many AEs appear to be attributable to human factors and/or user error, but the extent to which manufacturing companies are required by regulators to consider the interactions of users with the technical features of their products is limited. The clinical studies required by regulators prior to marketing are small and over-reliant on bench testing in relation to 'predicate' products. Once a pump is available on the market, insufficient data are made publicly available on its long-term use in a real-world setting; such data could provide vital information to help healthcare teams to educate and support users, and thereby prevent AEs. As well as requiring more from the manufacturing companies, we call for public funding of more research addressing clinically important questions in relation to pump therapy: both observational studies and clinical trials. At present there are significant differences in the regulatory systems between the USA and European Union at both pre- and post-marketing stages; improvements in the European system are more urgently required. This statement concludes with a series of recommended specific actions for 'meknovigilance' (i.e. a standardised safety approach to technology) which could be implemented to address the shortcomings we highlight.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hiperglucemia/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos , Insulina/administración & dosificación , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Vigilancia de Productos Comercializados , Medición de Riesgo
16.
Diabetologia ; 57(5): 868-77, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24445534

RESUMEN

AIMS/HYPOTHESIS: We evaluated whether self-monitoring of blood glucose (SMBG) leads to better glycaemic control (HbA(1c)) in patients with type 2 diabetes on conventional insulin regimens. METHODS: Patients with type 2 diabetes on a conventional insulin regimen (basal or premixed insulin with or without additional oral glucose-lowering agents) were recruited at study centres led by members of the German Diabetes Association. In a randomised, prospective, open 2 × 2 factorial design, the once-weekly performance of four-point glucose profiles (SMBG +; n = 151 patients) was compared with no SMBG (SMBG -; n = 149), and the measuring and transmitting of HbA1c results to the study centres (HbA(1c) +; n = 158, of these 82 SMBG - and 76 SMBG +) was compared with HbA1c measurement without disclosure of results (HbA(1c) -; n = 142, of these 67 SMBG - and 75 SMBG +). Randomised allocation was carried out by a central office, using sequentially numbered, sealed envelopes. The primary endpoint was the reduction of HbA(1c) compared with baseline after 12 months. Secondary analyses were of therapy intensification in response to higher blood or urinary glucose or HbA(1c). Participants and caregivers were not blinded as to the allocation of interventions, whereas the laboratory determining HbA(1c) remained blinded. RESULTS: Patient characteristics were balanced across groups. A total of 56 patients dropped out. In completers, HbA(1c) was reduced in the SMBG + group from 7.3% to 7.0%, i.e. by 0.3% (0.1%, 0.5%) vs SMBG - from 7.3% to 7.0% and 0.3% (0.2%, 0.5%), respectively, the difference being 0.0% (-0.2%, 0.2%) (p = 0.93). The disclosure of HbA(1c) results had no significant influence, with a difference of 0.1% (-0.1%, 0.4%) (p = 0.28). Values above are mean (95% CI). The ORs for therapy intensification significantly rose as the following increased: proportions of urine samples testing positive for glucose, HbA1c concentrations, and fasting or postprandial glucose concentrations. No important adverse events were associated with the interventions. CONCLUSIONS/INTERPRETATION: SMBG profiles once weekly or the disclosure of HbA(1c) results did not improve glycaemic control in patients with type 2 diabetes on conventional insulin treatment, although indicators of hyperglycaemia increased the likelihood of therapy intensification. Greater intensification may be necessary to impact on glycaemic control. TRIAL REGISTRATION: www.clinicaltrials.gov (registration code NCT00688363) FUNDING: Deutsche Diabetes-Gesellschaft, Deutsche Diabetes-Stiftung, Bayer Vital GmbH.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Insulina/uso terapéutico , Anciano , Glucemia/metabolismo , Ayuno , Femenino , Hemoglobina Glucada/uso terapéutico , Humanos , Hiperglucemia/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Masculino , Persona de Mediana Edad , Periodo Posprandial , Estudios Prospectivos , Resultado del Tratamiento
17.
J Diabetes Sci Technol ; : 19322968241257004, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38840530

RESUMEN

BACKGROUND: Diabetes technology is a fundamental part of modern diabetes therapy. Its widespread usage is associated with an increasing amount of "diabetes technology waste." The aim of this study was to quantify this waste in a real-world situation in a specialized diabetes practice in Germany. METHODS: Eighty patients with diabetes and insulin treatment participated and collected all of their therapy-associated waste for three months. Their attitude toward sustainability of antidiabetic therapy, waste generation, and their own waste reduction/separation behavior was surveyed. RESULTS: In total, 23 707 pieces of therapy-associated waste were collected. They comprised 5362 test strips, 630 glucose sensors, 14 619 needles, 519 insulin cartridges, 599 pens, and 1463 pieces of aids for insulin pump therapy. Type and quantity of the collected waste depended on the type of diabetes and the respective therapy, ie, multiple daily injections, usage of glucose sensors, or pump therapy. Most participants (92%) were surprised by the amounts of waste and reported an increased awareness toward the resource consumption of their therapy (87%). The survey indicated an enhanced interest in waste separation (94%) and a demand for the reduction and recycling of devices/aids (93%). CONCLUSIONS: Our data revealed the amount and complexity of the waste generated by modern diabetes therapy. Extrapolating these data, it can be estimated that around 1.2 billion pieces of diabetes technology waste are generated in Germany per year. The major concern of the study participants was the limited number of recycling options. A clear demand for improved sustainability of the medical products was expressed.

18.
J Diabetes Sci Technol ; : 19322968241239870, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38529954

RESUMEN

BACKGROUND: In a randomized controlled trial, the efficacy of a digital diabetes diary regarding a reduction of diabetes distress was evaluated. METHODS: A randomized controlled trial with a 12-week follow-up was conducted in 41 study sites across Germany. Key eligibility criteria were a diagnosis of type 1, type 2, or gestational diabetes and regular self-monitoring of blood glucose. Participants were randomly assigned (2:1 ratio) to either use the digital diabetes logbook (mySugr PRO), or to the control group without app use. The primary outcome was the reduction in diabetes distress at the 12-week follow-up. All analyses were based on the intention-to-treat population with all randomized participants. The trial was registered at the German Register for Clinical Studies (DRKS00022923). RESULTS: Between February 11, 2021, and June 24, 2022, 424 participants (50% female, 50% male) were included, with 282 being randomized to the intervention group (66.5%) and 142 to the control group (33.5%). A total of 397 participants completed the trial (drop-out rate: 6.4%). The median reduction in diabetes distress was 2.41 (interquartile range [IQR]: -2.50 to 8.11) in the intervention group and 1.25 (IQR: -5.00 to 7.50) in the control group. The model-based adjusted between-group difference was significant (-2.20, IQR: -4.02 to -0.38, P = .0182) favoring the intervention group. There were 27 adverse events, 17 (6.0%) in the intervention group, and 10 (7.0%) in the control group. CONCLUSIONS: The efficacy of the digital diabetes logbook was demonstrated regarding improvements in mental health in people with type 1, type 2, and gestational diabetes.

19.
Diabetes Technol Ther ; 26(5): 351-362, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38215209

RESUMEN

Background: Lipohypertrophy is a common complication in patients with diabetes receiving insulin therapy. There is a lack of consensus regarding how much lipohypertrophy affects diabetes management. Our study aimed to assess the potential correlation between lipohypertrophy and glycemic control, as well as insulin dosing in patients with diabetes. Methods: We performed a systematic review followed by a meta-analysis to collect data about glycemic control and insulin dosing in diabetic patients with and without lipohypertrophy. To identify relevant studies published in English, we searched medical databases (MEDLINE/PubMed, Embase, and CENTRAL) from 1990 to January 20, 2023. An additional hand-search of references was performed to retrieve publications not indexed in medical databases. Results of meta-analyses were presented either as prevalence odds ratios (pORs) or mean differences (MDs) with 95% confidence intervals (95% CIs). This study was registered on PROSPERO (CRD42023393103). Results: Of the 5540 records and 240 full-text articles screened, 37 studies fulfilled the prespecified inclusion criteria. Performed meta-analyses showed that patients with lipohypertrophy compared with those without lipohypertrophy were more likely to experience unexplained hypoglycemia (pOR [95% CI] = 6.98 [3.30-14.77]), overall hypoglycemia (pOR [95% CI] = 6.65 [1.37-32.36]), and glycemic variability (pOR [95% CI] = 5.24 [2.68-10.23]). Patients with lipohypertrophy also had higher HbA1c (MD [95% CI] = 0.55 [0.23-0.87] %), and increased daily insulin consumption (MD [95% CI] = 7.68 IU [5.31-10.06]). Conclusions: These results suggest that overall glycemic control is worse in patients with lipohypertrophy than in those without this condition.


Asunto(s)
Control Glucémico , Hipoglucemiantes , Insulina , Humanos , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Control Glucémico/efectos adversos , Glucemia/análisis , Glucemia/efectos de los fármacos , Hemoglobina Glucada/análisis , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA