Int J Radiat Oncol Biol Phys ; 118(3): 682-687, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37776979

RESUMEN

PURPOSE: Ultrahypofractionated radiation therapy (UHRT) is an effective treatment for localized prostate cancer with an acceptable toxicity profile; boosting the visible intraprostatic tumor has been shown to improve biochemical disease-free survival with no significant effect on genitourinary (GU) and gastrointestinal (GI) toxicity. METHODS AND MATERIALS: HERMES is a single-center noncomparative randomized phase 2 trial in men with intermediate or lower high risk prostate cancer. Patients were allocated (1:1) to 36.25 Gy in 5 fractions over 2 weeks or 24 Gy in 2 fractions over 8 days with an integrated boost to the magnetic resonance imaging (MRI) visible tumor of 27 Gy in 2 fractions. A minimization algorithm with a random element with risk group as a balancing factor was used for participant randomization. Treatment was delivered on the Unity MR-Linac (Elekta AB) with daily online adaption. The primary endpoint was acute GU Common Terminology Criteria for Adverse Events version 5.0 toxicity with the aim of excluding a doubling of the rate of acute grade 2+ GU toxicity seen in PACE. Analysis was by treatment received and included all participants who received at least 1 fraction of study treatment. This interim analysis was prespecified (stage 1 of a 2-stage Simon design) for when 10 participants in each treatment group had completed the acute toxicity monitoring period (12 weeks after radiation therapy). RESULTS: Acute grade 2 GU toxicity was reported in 1 (10%) patient in the 5-fraction group and 2 (20%) patients in the 2-fraction group. No grade 3+ GU toxicities were reported. CONCLUSIONS: At this interim analysis, the rate of GU toxicity in the 2-fraction and 5-fraction treatment groups was found to be below the prespecified threshold (5/10 grade 2+) and continuation of the study to complete recruitment of 23 participants per group was recommended.


Asunto(s)
Enfermedades Gastrointestinales , Neoplasias de la Próstata , Humanos , Masculino , Imagen por Resonancia Magnética , Pelvis , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Sistema Urogenital/efectos de la radiación , Ensayos Clínicos Controlados Aleatorios como Asunto , Ensayos Clínicos Fase II como Asunto
2.
Adv Radiat Oncol ; 9(6): 101490, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38681895

RESUMEN

Purpose: Swallow-related motion of the larynx is most significant in the cranio-caudal directions and of` short duration. Conventional target definition for radical radiation therapy includes coverage of the whole larynx. This study longitudinally examined respiration- and swallow-related laryngeal motions using cine-magnetic resonance imaging. We further analyzed the dosimetry to organs at risk by comparing 3D-conformal radiation therapy (3D-CRT), volumetric modulated arc therapy (VMAT), and intensity modulated radiation therapy (IMRT) techniques. Methods: Fifteen patients with T1-2 N0 glottic squamous cell carcinomas were prospectively recruited for up to 3 cine-MRI scans on the Elekta Unity MR-Linear accelerator, at the beginning, middle, and end of a course of radical radiation therapy. Swallow frequency and motion of the hyoid bone, cricoid and thyroid cartilages, and vocal cords were recorded during swallow and rest. Adapted treatment volumes consisted of gross tumor volume + 0.5-1 cm to a clinical target volume with an additional internal target volume (ITV) for personalized resting-motion. Swallow-related motion was deemed infrequent and was not accounted for in the ITV. We compared radiation therapy plans for 3D-CRT (whole larynx), VMAT (whole larynx), and VMAT and IMRT (ITV for resting motion). Results: Resting- and swallow-related motions were most prominent in the cranio-caudal plane. There were no significant changes in the magnitude of motion over the course of radiation therapy. There was a trend of a progressive reduction in the frequency of swallow. Treatment of partial larynx volumes with intensity modulated methods significantly reduced the dose to carotid arteries, compared with treatment of whole larynx volumes. Robustness analysis demonstrated that when accounting for intrafraction swallow, the total dose delivered to the ITV/planning target volume was maintained at above 95%. Conclusions: Swallow-related motions are infrequent and accounting for resting motion in an ITV is sufficient. VMAT/IMRT techniques that treat more conformal targets can significantly spare critical organs at risk such as the carotid arteries and thyroid gland, potentially reducing the risk of carotid artery stenosis-related complications and other long-term complications.

3.
Clin Transl Radiat Oncol ; 46: 100742, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38440792

RESUMEN

Background and purpose: MRI-guided radiotherapy (MRIgRT) offers multiple potential advantages over CT-guidance. This study examines the potential clinical benefits of MRIgRT for men with localised prostate cancer, in the setting of moderately hypofractionated radiotherapy. We evaluate two-year toxicity outcomes, early biochemical response and patient-reported outcomes (PRO), using data obtained from a multicentre international registry study, for the first group of patients with prostate cancer who underwent treatment on a 1.5 T MR-Linac. Materials and methods: Patients who were enrolled within the MOMENTUM study and received radical treatment with 60 Gy in 20 fractions were identified. PSA levels and CTCAE version 5.0 toxicity data were measured at follow-up visits. Those patients who consented to PRO data collection also completed EQ-5D-5L, EORTC QLQ-C30 and EORTC QLQ-PR25 questionnaires. Results: Between November 2018 and June 2022, 146 patients who had MRIgRT for localised prostate cancer on the 1.5 T MR-Linac were eligible for this study. Grade 2 and worse gastro-intestinal (GI) toxicity was reported in 3 % of patients at three months whilst grade 2 and worse genitourinary (GU) toxicity was 7 % at three months. There was a significant decrease in the median PSA at 12 months. The results from both the EQ-5D-5L data and EORTC global health status scale indicate a decline in the quality of life (QoL) during the first six months. The mean change in score for the EORTC scale showed a decrease of 11.4 points, which is considered clinically important. QoL improved back to baseline by 24 months. Worsening of hormonal symptoms in the first six months was reported with a return to baseline by 24 months and sexual activity in all men worsened in the first three months and returned to baseline at 12 months. Conclusion: This study establishes the feasibility of online-MRIgRT for localised prostate on a 1.5 T MR-Linac with low rates of toxicity, similar to that published in the literature. However, the clinical benefits of MRIgRT over conventional radiotherapy in the setting of moderate hypofractionation is not evident. Further research will focus on the delivery of ultrahypofractionated regimens, where the potential advantages of MRIgRT for prostate cancer may become more discernible.

4.
Phys Imaging Radiat Oncol ; 27: 100481, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37655122

RESUMEN

Hybrid systems that combine Magnetic Resonance Imaging (MRI) and linear accelerators are available clinically to guide and adapt radiotherapy. Vendor-approved MRI sequences are provided, however alternative sequences may offer advantages. The aim of this study was to develop a systematic approach for non-vendor sequence evaluation, to determine safety, accuracy and overall clinical application of two potential sequences for bladder cancer MRI guided radiotherapy. Non-vendor sequences underwent and passed clinical image qualitative review, phantom quality assurance, and radiotherapy planning assessments. Volunteer workflow tests showed the potential for one sequence to reduce workflow time by 27% compared to the standard vendor sequence.

5.
Radiother Oncol ; 180: 109457, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36608770

RESUMEN

BACKGROUND AND PURPOSE: The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers' roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. MATERIALS AND METHODS: 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. RESULTS: Comparison of the radiographers' and clinicians' contours resulted in a median (range) DSC of 0.92 (0.86 - 0.99), median (range) MDA of 0.98 mm (0.2-1.7) and median (range) HD of 6.3 mm (2.5-11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians' offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88-1.0), median (range) MDA was 0.8 mm (0.04-1.18) and HD was 5.15 mm (2.09-8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians' offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. CONCLUSION: Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training.


Asunto(s)
Neoplasias de la Próstata , Radioterapia Guiada por Imagen , Masculino , Humanos , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Vesículas Seminales , Pelvis , Radioterapia Guiada por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Planificación de la Radioterapia Asistida por Computador/métodos
6.
Artículo en Inglés | MEDLINE | ID: mdl-36654720

RESUMEN

The implementation of MRI-guided online adaptive radiotherapy has enabled extension of therapeutic radiographers' roles to include contouring. An offline interobserver variability study compared five radiographers' and five clinicians' contours on 10 MRIs acquired on a MR-Linac from 10 patients. All contours were compared to a "gold standard" created from an average of clinicians' contours. The median (range) DSC of radiographers' and clinicians' contours compared to the "gold standard" was 0.91 (0.86-0.96), and 0.93 (0.88-0.97) respectively illustrating non-inferiority of the radiographers' contours to the clinicians. There was no significant difference in HD, MDA or volume size between the groups.

7.
Artículo en Inglés | MEDLINE | ID: mdl-35243043

RESUMEN

The implementation of adaptive radiotherapy for prostate cancer compensates for inter-fraction motion, at the penalty of increased time in room. The subsequent increase in bladder filling may impact dosimetry, which we have investigated on ten patients treated on the MR-linac. Patients drank water before treatment, to achieve a bladder volume of 200-300 cm3. Bladder and bowel were re-outlined offline on 140 images and plans recalculated. All mandatory bladder dose constraints and 99.1% of bowel constraints were achieved at time of treatment, despite varying bladder volumes and varying adherence to original bladder filling guidance.

8.
Phys Med Biol ; 66(5)2021 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-33450742

RESUMEN

This document gives guidance for multidisciplinary teams within institutions setting up and using an MRI-guided radiotherapy (RT) treatment planning service. It has been written by a multidisciplinary working group from the Institute of Physics and Engineering in Medicine (IPEM). Guidance has come from the experience of the institutions represented in the IPEM working group, in consultation with other institutions, and where appropriate references are given for any relevant legislation, other guidance documentation and information in the literature. Guidance is only given for MRI acquired for external beam RT treatment planning in a CT-based workflow, i.e. when MRI is acquired and registered to CT with the purpose of aiding delineation of target or organ at risk volumes. MRI use for treatment response assessment, MRI-only RT and other RT treatment types such as brachytherapy and gamma radiosurgery are not considered within the scope of this document. The aim was to produce guidance that will be useful for institutions who are setting up and using a dedicated MR scanner for RT (referred to as an MR-sim) and those who will have limited time on an MR scanner potentially managed outside of the RT department, often by radiology. Although not specifically covered in this document, there is an increase in the use of hybrid MRI-linac systems worldwide and brief comments are included to highlight any crossover with the early implementation of this technology. In this document, advice is given on introducing a RT workload onto a non-RT-dedicated MR scanner, as well as planning for installation of an MR scanner dedicated for RT. Next, practical guidance is given on the following, in the context of RT planning: training and education for all staff working in and around an MR scanner; RT patient set-up on an MR scanner; MRI sequence optimisation for RT purposes; commissioning and quality assurance (QA) to be performed on an MR scanner; and MRI to CT registration, including commissioning and QA.


Asunto(s)
Radioterapia Guiada por Imagen , Humanos , Yodobencenos , Imagen por Resonancia Magnética , Maleimidas , Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador
9.
Clin Transl Radiat Oncol ; 30: 31-37, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34307911

RESUMEN

INTRODUCTION: With the implementation of new radiotherapy technology, it is imperative that patient experience is investigated alongside efficacy and outcomes. This paper presents the development of a specifically designed validated questionnaire and a first report of international multi-institutional preliminary patient experience of MRI-guided adaptive radiotherapy (MRgART) on the 1.5 T MR-Linac (MRL). METHODS: A patient experience questionnaire was developed and validated before being distributed to the Elekta MRL Consortium, to gather first patient-reported experience from participating centres worldwide. The final version of the questionnaire contains 18 questions covering a range of themes and was scored on a Likert scale of 0-3. Responses were post-processed so that a score of 0 represents a negative response and 3 represents the most favourable response. These results were analysed for patient-reported experience of treatment on the MRL. Results were also analysed for internal consistency of the questionnaire using Chronbach's Alpha and the questionnaire contents were validated for relevance using content validity indexes (CVI). RESULTS: 170 responses were received from five centres, representing patients with a wide range of tumour treatment sites from four different countries. MRgART was well tolerated with an 84% favourable response across all questions and respondents. When analysed by theme, all reported the highest percentage of results in the favourable categories (2 and 3). Internal consistency in the questionnaire was high (Cronbach's α = 0.8) and the item-level CVI for each question was 0.78 or above and the Scale-level CVI was 0.93, representing relevant content. CONCLUSION: The developed questionnaire has been validated as relevant and appropriate for use in reporting experience of patients undergoing treatment on the MRL. The overall patient-reported experience and satisfaction from multiple centres within the Elekta MRL Consortium was consistently high. These results can reinforce user confidence in continuing to expand and develop MRL use in adaptive radiotherapy.

10.
Phys Med Biol ; 66(7)2021 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-33631729

RESUMEN

Introduction/Background. Despite growing interest in magnetic resonance imaging (MRI), integration in external beam radiotherapy (EBRT) treatment planning uptake varies globally. In order to understand the current international landscape of MRI in EBRT a survey has been performed in 11 countries. This work reports on differences and common themes identified.Methods. A multi-disciplinary Institute of Physics and Engineering in Medicine working party modified a survey previously used in the UK to understand current practice using MRI for EBRT treatment planning, investigate how MRI is currently used and managed as well as identify knowledge gaps. It was distributed electronically within 11 countries: Australia, Belgium, Denmark, Finland, France, Italy, the Netherlands, New Zealand, Sweden, the UK and the USA.Results. The survey response rate within the USA was <1% and hence these results omitted from the analysis. In the other 10 countries the survey had a median response rate of 77% per country. Direct MRI access, defined as either having a dedicated MRI scanner for radiotherapy (RT) or access to a radiology MRI scanner, varied between countries. France, Italy and the UK reported the lowest direct MRI access rates and all other countries reported direct access in ≥82% of centres. Whilst ≥83% of centres in Denmark and Sweden reported having dedicated MRI scanners for EBRT, all other countries reported ≤29%. Anatomical sites receiving MRI for EBRT varied between countries with brain, prostate, head and neck being most common. Commissioning and QA of image registration and MRI scanners varied greatly, as did MRI sequences performed, staffing models and training given to different staff groups. The lack of financial reimbursement for MR was a consistent barrier for MRI implementation for RT for all countries and MR access was a reported important barrier for all countries except Sweden and Denmark.Conclusion. No country has a comprehensive approach for MR in EBRT adoption and financial barriers are present worldwide. Variations between countries in practice, equipment, staffing models, training, QA and MRI sequences have been identified, and are likely to be due to differences in funding as well as a lack of consensus or guidelines in the literature. Access to dedicated MR for EBRT is limited in all but Sweden and Denmark, but in all countries there are financial challenges with ongoing per patient costs. Despite these challenges, significant interest exists in increasing MR guided EBRT planning over the next 5 years.


Asunto(s)
Yodobencenos , Humanos , Imagen por Resonancia Magnética , Masculino , Maleimidas , Planificación de la Radioterapia Asistida por Computador/métodos
11.
Artículo en Inglés | MEDLINE | ID: mdl-32128459

RESUMEN

The MR-Linac (MRL) provides a novel treatment modality that enables online adaptive treatments, but also creates new challenges for patient positioning in a laser-free environment. The accuracy and duration of prostate patient set-up on the MRL using two different methods for patient alignment was determined to establish standard of practice on the MRL. Differences in set-up accuracy were significant in the longitudinal direction and are accounted for in online plan adaption. Both methods recorded similar set-up times. The vendor recommended alignment method involves less manipulation of the patient and will be adopted as the standard positioning method for prostate and other pelvic patients on the MRL in future.

12.
Clin Transl Radiat Oncol ; 23: 35-42, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32395640

RESUMEN

INTRODUCTION: MR-guided adapted radiotherapy (MRgART) using a high field MR-linac has recently become available. We report the estimated delivered fractional dose of the first five prostate cancer patients treated at our centre using MRgART and compare this to C-Arm linac daily Image Guided Radiotherapy (IGRT). METHODS: Patients were treated using adapted treatment plans shaped to their daily anatomy. The treatments were recalculated on an MR image acquired immediately prior to treatment delivery in order to estimate the delivered fractional dose. C-arm linac non-adapted VMAT treatment plans were recalculated on the same MR images to estimate the fractional dose that would have been delivered using conventional radiotherapy techniques using a daily IGRT protocol. RESULTS: 95% and 93% of mandatory target coverage objectives and organ at risk dose constraints were achieved by MRgART and C-arm linac delivered dose estimates, respectively. Both delivery techniques were estimated to have achieved 98% of mandatory Organ At Risk (OAR) dose constraints whereas for the target clinical goals, 86% and 80% were achieved by MRgART and C-arm linac delivered dose estimates. CONCLUSIONS: Prostate MRgART can be delivered using the a high field MR-linac. Radiotherapy performed on a C-arm linac offers a good solution for prostate cancer patients who present with favourable anatomy at the time of reference imaging and demonstrate stable anatomy throughout the course of their treatment. For patients with critical OARs abutting target volumes on their reference image we have demonstrated the potential for a target dose coverage improvement for MRgART compared to C-arm linac treatment.

14.
Br J Radiol ; 92(1095): 20180948, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30676772

RESUMEN

OBJECTIVE:: With increasing incorporation of MRI in radiotherapy, we investigate two MRI sequences for prostate delineation in radiographer-led image guidance. METHODS:: Five therapeutic radiographers contoured the prostate individually on CT, T2 weighted (T2W) and T2* weighted (T2*W) imaging for 10 patients. Contours were analysed with Monaco ADMIRE (research v. 2.0) to assess interobserver variability and accuracy by comparison with a gold standard clinician contour. Observers recorded time taken for contouring and scored image quality and confidence in contouring. RESULTS:: There is good agreement when comparing radiographer contours to the gold-standard for all three imaging types with Dice similarity co-efficient 0.91-0.94, Cohen's κ 0.85-0.91, Hausdorff distance 4.6-7.6 mm and mean distance between contours 0.9-1.2 mm. In addition, there is good concordance between radiographers across all imaging modalities. Both T2W and T2*W MRI show reduced interobserver variability and improved accuracy compared to CT, this was statistically significant for T2*W imaging compared to CT across all four comparison metrics. Comparing MRI sequences reveals significantly reduced interobserver variability and significantly improved accuracy on T2*W compared to T2W MRI for DSC and Cohen's κ. Both MRI sequences scored significantly higher compared to CT for image quality and confidence in contouring, particularly T2*W. This was also reflected in the shorter time for contouring, measuring 15.4, 9.6 and 9.8 min for CT, T2W and T2*W MRI respectively. Conclusion: Therapeutic radiographer prostate contours are more accurate, show less interobserver variability and are more confidently and quickly outlined on MRI compared to CT, particularly using T2*W MRI. Advances in knowledge: Our work is relevant for MRI sequence choice and development of the roles of the interprofessional team in the advancement of MRI-guided radiotherapy.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Humanos , Masculino , Variaciones Dependientes del Observador , Próstata/efectos de la radiación , Tomografía Computarizada por Rayos X/métodos