Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Vasc Interv Radiol ; 35(7): 979-988.e1, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38537737

RESUMEN

PURPOSE: To assess the different adjunctive catheter techniques required to achieve complete occlusion of renal arteriovenous malformations (rAVMs) of different angioarchitectural types. MATERIALS AND METHODS: Overall, data on 18 patients with rAVM (Type 1, n = 7; Type 2, n = 2; Type 3, n = 9; mean age, 53.8 years) who underwent 25 procedures between 2011 and 2022 were reviewed. The clinical presentations, endovascular techniques, arteriovenous malformation (AVM) occlusion rate, adverse events (including the incidence of renal infarction), and clinical symptoms and outcomes (including recurrence/increase of AVM) were analyzed according to the Cho-Do angioarchitectural classification. Posttreatment renal infarction was classified as no infarction, small infarction (<12.5%), medium infarction (12.5%-25%), and large infarction (>25%) using contrast-enhanced computed tomography or magnetic resonance imaging. RESULTS: Hematuria and heart failure were presenting symptoms in 10 and 2 patients, respectively. The embolic materials used were as follows: Type 1 rAVM, coils alone or with n-butyl-2-cyanoacrylate (nBCA); Type 2 rAVM, nBCA alone or with coils; and Type 3 rAVMs, nBCA alone. Fourteen patients underwent adjunctive catheter techniques, including flow control with a balloon catheter and multiple microcatheter placement, alone or in combination. Immediate postprocedural angiography revealed complete occlusion in 15 patients (83%) and marked regression of rAVM in 3 (17%). Small asymptomatic renal infarctions were observed in 6 patients with Type 3 rAVMs without any decrease in renal function. No major adverse events were observed. All symptomatic patients experienced symptom resolution. Recurrence/increase of rAVM was not observed during the mean 32-month follow-up period (range, 2-120 months). CONCLUSIONS: Transarterial embolization using adjunctive catheter techniques according to angioarchitectural types can be an effective treatment for rAVMs.


Asunto(s)
Malformaciones Arteriovenosas , Embolización Terapéutica , Arteria Renal , Venas Renales , Humanos , Persona de Mediana Edad , Femenino , Masculino , Embolización Terapéutica/efectos adversos , Malformaciones Arteriovenosas/terapia , Malformaciones Arteriovenosas/diagnóstico por imagen , Resultado del Tratamiento , Adulto , Estudios Retrospectivos , Anciano , Arteria Renal/diagnóstico por imagen , Arteria Renal/anomalías , Venas Renales/diagnóstico por imagen , Venas Renales/anomalías , Angiografía por Tomografía Computarizada , Valor Predictivo de las Pruebas , Recurrencia , Factores de Tiempo , Adulto Joven , Factores de Riesgo , Enbucrilato/administración & dosificación , Infarto/diagnóstico por imagen , Infarto/etiología , Infarto/terapia , Angiografía por Resonancia Magnética
2.
Neuroradiology ; 66(7): 1123-1130, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38480538

RESUMEN

PURPOSE: We aimed to evaluate the effect of deep learning-based reconstruction (DLR) on high-spatial-resolution three-dimensional T2-weighted fast asymmetric spin-echo (HR-3D T2-FASE) imaging in the preoperative evaluation of cerebellopontine angle (CPA) tumors. METHODS: This study included 13 consecutive patients who underwent preoperative HR-3D T2-FASE imaging using a 3 T MRI scanner. The reconstruction voxel size of HR-3D T2-FASE imaging was 0.23 × 0.23 × 0.5 mm. The contrast-to-noise ratios (CNRs) of the structures were compared between HR-3D T2-FASE images with and without DLR. The observers' preferences based on four categories on the tumor side on HR-3D T2-FASE images were evaluated. The facial nerve in relation to the tumor on HR-3D T2-FASE images was assessed with reference to intraoperative findings. RESULTS: The mean CNR between the tumor and trigeminal nerve and between the cerebrospinal fluid and trigeminal nerve was significantly higher for DLR images than non-DLR-based images (14.3 ± 8.9 vs. 12.0 ± 7.6, and 66.4 ± 12.0 vs. 53.9 ± 8.5, P < 0.001, respectively). The observer's preference for the depiction and delineation of the tumor, cranial nerves, vessels, and location relation on DLR HR-3D T2FASE images was superior to that on non-DLR HR-3D T2FASE images in 7 (54%), 6 (46%), 6 (46%), and 6 (46%) of 13 cases, respectively. The facial nerves around the tumor on HR-3D T2-FASE images were visualized accurately in five (38%) cases with DLR and in four (31%) without DLR. CONCLUSION: DLR HR-3D T2-FASE imaging is useful for the preoperative assessment of CPA tumors.


Asunto(s)
Aprendizaje Profundo , Imagenología Tridimensional , Imagen por Resonancia Magnética , Cuidados Preoperatorios , Humanos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Cuidados Preoperatorios/métodos , Anciano , Ángulo Pontocerebeloso/diagnóstico por imagen , Ángulo Pontocerebeloso/cirugía , Neoplasias Cerebelosas/diagnóstico por imagen , Neoplasias Cerebelosas/cirugía , Interpretación de Imagen Asistida por Computador/métodos , Estudios Retrospectivos , Neuroma Acústico/diagnóstico por imagen , Neuroma Acústico/cirugía
3.
Neuroradiology ; 66(2): 217-226, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38148334

RESUMEN

PURPOSE: The aim of this study is to assess the effect of super-resolution deep learning-based reconstruction (SR-DLR), which uses k-space properties, on image quality of intracranial time-of-flight (TOF) magnetic resonance angiography (MRA) at 3 T. METHODS: This retrospective study involved 35 patients who underwent intracranial TOF-MRA using a 3-T MRI system with SR-DLR based on k-space properties in October and November 2022. We reconstructed MRA with SR-DLR (matrix = 1008 × 1008) and MRA without SR-DLR (matrix = 336 × 336). We measured the signal-to-noise ratio (SNR), contrast, and contrast-to-noise ratio (CNR) in the basilar artery (BA) and the anterior cerebral artery (ACA) and the sharpness of the posterior cerebral artery (PCA) using the slope of the signal intensity profile curve at the half-peak points. Two radiologists evaluated image noise, artifacts, contrast, sharpness, and overall image quality of the two image types using a 4-point scale. We compared quantitative and qualitative scores between images with and without SR-DLR using the Wilcoxon signed-rank test. RESULTS: The SNRs, contrasts, and CNRs were all significantly higher in images with SR-DLR than those without SR-DLR (p < 0.001). The slope was significantly greater in images with SR-DLR than those without SR-DLR (p < 0.001). The qualitative scores in MRAs with SR-DLR were all significantly higher than MRAs without SR-DLR (p < 0.001). CONCLUSION: SR-DLR with k-space properties can offer the benefits of increased spatial resolution without the associated drawbacks of longer scan times and reduced SNR and CNR in intracranial MRA.


Asunto(s)
Aprendizaje Profundo , Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Estudios Retrospectivos , Imagen por Resonancia Magnética , Relación Señal-Ruido , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
4.
Artículo en Inglés | MEDLINE | ID: mdl-38346820

RESUMEN

OBJECTIVE: The aim of this study was to assess the utility of the combined use of 3D wheel sampling and deep learning-based reconstruction (DLR) for intracranial high-resolution (HR)-time-of-flight (TOF)-magnetic resonance angiography (MRA) at 3 T. METHODS: This prospective study enrolled 20 patients who underwent head MRI at 3 T, including TOF-MRA. We used 3D wheel sampling called "fast 3D" and DLR for HR-TOF-MRA (spatial resolution, 0.39 × 0.59 × 0.5 mm3) in addition to conventional MRA (spatial resolution, 0.39 × 0.89 × 1 mm3). We compared contrast and contrast-to-noise ratio between the blood vessels (basilar artery and anterior cerebral artery) and brain parenchyma, full width at half maximum in the P3 segment of the posterior cerebral artery among 3 protocols. Two board-certified radiologists evaluated noise, contrast, sharpness, artifact, and overall image quality of 3 protocols. RESULTS: The contrast and contrast-to-noise ratio of fast 3D-HR-MRA with DLR are comparable or higher than those of conventional MRA and fast 3D-HR-MRA without DLR. The full width at half maximum was significantly lower in fast 3D-MRA with and without DLR than in conventional MRA (P = 0.006, P < 0.001). In qualitative evaluation, fast 3D-MRA with DLR had significantly higher sharpness and overall image quality than conventional MRA and fast 3D-MRA without DLR (sharpness: P = 0.021, P = 0.001; overall image quality: P = 0.029, P < 0.001). CONCLUSIONS: The combination of 3D wheel sampling and DLR can improve visualization of arteries in intracranial TOF-MRA.

5.
Neuroradiology ; 65(11): 1619-1629, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37673835

RESUMEN

PURPOSE: The purpose of this study is to evaluate the influence of super-resolution deep learning-based reconstruction (SR-DLR), which utilizes k-space data, on the quality of images and the quantitation of the apparent diffusion coefficient (ADC) for diffusion-weighted images (DWI) in brain magnetic resonance imaging (MRI). METHODS: A retrospective analysis was performed on 34 patients who had undergone DWI using a 3 T MRI system with SR-DLR reconstruction based on k-space data in August 2022. DWI was reconstructed with SR-DLR (Matrix = 684 × 684) and without SR-DLR (Matrix = 228 × 228). Measurements were made of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) in white matter (WM) and grey matter (GM), and the full width at half maximum (FWHM) of the septum pellucidum. Two radiologists assessed image noise, contrast, artifacts, blur, and the overall quality of three image types using a four-point scale. Quantitative and qualitative scores between images with and without SR-DLR were compared using the Wilcoxon signed-rank test. RESULTS: Images with SR-DLR showed significantly higher SNRs and CNRs than those without SR-DLR (p < 0.001). No statistically significant variances were found in the apparent diffusion coefficients (ADCs) in WM and GM between images with and without SR-DLR (ADC in WM, p = 0.945; ADC in GM, p = 0.235). Moreover, the FWHM without SR-DLR was notably lower compared to that with SR-DLR (p < 0.001). CONCLUSION: SR-DLR has the potential to augment the quality of DWI in DL MRI scans without significantly impacting ADC quantitation.

6.
Jpn J Radiol ; 42(2): 190-200, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37713022

RESUMEN

PURPOSE: In this preliminary study, we aimed to evaluate the potential of the generative pre-trained transformer (GPT) series for generating radiology reports from concise imaging findings and compare its performance with radiologist-generated reports. METHODS: This retrospective study involved 28 patients who underwent computed tomography (CT) scans and had a diagnosed disease with typical imaging findings. Radiology reports were generated using GPT-2, GPT-3.5, and GPT-4 based on the patient's age, gender, disease site, and imaging findings. We calculated the top-1, top-5 accuracy, and mean average precision (MAP) of differential diagnoses for GPT-2, GPT-3.5, GPT-4, and radiologists. Two board-certified radiologists evaluated the grammar and readability, image findings, impression, differential diagnosis, and overall quality of all reports using a 4-point scale. RESULTS: Top-1 and Top-5 accuracies for the different diagnoses were highest for radiologists, followed by GPT-4, GPT-3.5, and GPT-2, in that order (Top-1: 1.00, 0.54, 0.54, and 0.21, respectively; Top-5: 1.00, 0.96, 0.89, and 0.54, respectively). There were no significant differences in qualitative scores about grammar and readability, image findings, and overall quality between radiologists and GPT-3.5 or GPT-4 (p > 0.05). However, qualitative scores of the GPT series in impression and differential diagnosis scores were significantly lower than those of radiologists (p < 0.05). CONCLUSIONS: Our preliminary study suggests that GPT-3.5 and GPT-4 have the possibility to generate radiology reports with high readability and reasonable image findings from very short keywords; however, concerns persist regarding the accuracy of impressions and differential diagnoses, thereby requiring verification by radiologists.


Asunto(s)
Radiología , Humanos , Estudios Retrospectivos , Radiografía , Tomografía Computarizada por Rayos X , Radiólogos
7.
Eur J Radiol ; 178: 111587, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39002269

RESUMEN

OBJECTIVES: This study aims to assess the effectiveness of super-resolution deep-learning-based reconstruction (SR-DLR), which leverages k-space data, on the image quality of lumbar spine magnetic resonance (MR) bone imaging using a 3D multi-echo in-phase sequence. MATERIALS AND METHODS: In this retrospective study, 29 patients who underwent lumbar spine MRI, including an MR bone imaging sequence between January and April 2023, were analyzed. Images were reconstructed with and without SR-DLR (Matrix sizes: 960 × 960 and 320 × 320, respectively). The signal-to-noise ratio (SNR) of the vertebral body and spinal canal and the contrast and contrast-to-noise ratio (CNR) between the vertebral body and spinal canal were quantitatively evaluated. Furthermore, the slope at half-peak points of the profile curve drawn across the posterior border of the vertebral body was calculated. Two radiologists independently assessed image noise, contrast, artifacts, sharpness, and overall image quality of both image types using a 4-point scale. Interobserver agreement was evaluated using weighted kappa coefficients, and quantitative and qualitative scores were compared via the Wilcoxon signed-rank test. RESULTS: SNRs of the vertebral body and spinal canal were notably improved in images with SR-DLR (p < 0.001). Contrast and CNR were significantly enhanced with SR-DLR compared to those without SR-DLR (p = 0.023 and p = 0.022, respectively). The slope of the profile curve at half-peak points across the posterior border of the vertebral body and spinal canal was markedly higher with SR-DLR (p < 0.001). Qualitative scores (noise: p < 0.001, contrast: p < 0.001, artifact p = 0.042, sharpness: p < 0.001, overall image quality: p < 0.001) were superior in images with SR-DLR compared to those without. Kappa analysis indicated moderate to good agreement (noise: κ = 0.56, contrast: κ = 0.51, artifact: κ = 0.46, sharpness: κ = 0.76, overall image quality: κ = 0.44). CONCLUSION: SR-DLR, which is based on k-space data, has the potential to enhance the image quality of lumbar spine MR bone imaging utilizing a 3D gradient echo in-phase sequence. CLINICAL RELEVANCE STATEMENT: The application of SR-DLR can lead to improvements in lumbar spine MR bone imaging quality.


Asunto(s)
Aprendizaje Profundo , Vértebras Lumbares , Imagen por Resonancia Magnética , Humanos , Femenino , Vértebras Lumbares/diagnóstico por imagen , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Anciano , Adulto , Relación Señal-Ruido , Imagenología Tridimensional/métodos , Anciano de 80 o más Años , Enfermedades de la Columna Vertebral/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA