Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Rehabil ; 38(7): 955-964, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38444212

RESUMEN

OBJECTIVE: The Posterior Standing Overhead Arm Reach (SOAR) test has been previously reported as a reliable clinical measure of closed chain hip extension motion. The proposed Medial SOAR test expands on that testing approach to provide a similar measure of functional hip adduction motion. This was a preliminary intrarater and interrater reliability and validity study of the Medial SOAR test as a measure of functional hip adduction. DESIGN: Cross-sectional. SETTING: University motion analysis laboratory. PARTICIPANTS: Fifty hips were assessed in 25 (22 female) asymptomatic participants (mean age = 23.4 years, SD = 0.8). MAIN MEASURES: Maximum hip adduction during the Medial SOAR test was measured with a standard goniometer independently by two examiners. The test was also performed using three-dimensional motion capture. The intrarater and interrater reliability of the goniometric measure was determined using intraclass correlation coefficients, and the relationship between measures obtained via goniometry and three-dimensional motion capture was assessed with Pearson correlations and Bland-Altman analysis. RESULTS: Intrarater reliability (ICC2,3) was 0.88 (95% CI = 0.80-0.92) for Examiner 1 and 0.87 (95% CI = 0.79-0.92) for Examiner 2. The standard error of measurement and minimal detectable change were less than 3.0°. Interrater reliability demonstrated an intraclass correlation coefficient = 0.62 (95% CI = 0.28-0.79). Pearson correlations were significant with low-to-moderate associations (r = 0.49, P < 0.001; r = 0.24, P = 0.045). CONCLUSIONS: Similar to the previously reported Posterior SOAR test, the Medial SOAR test demonstrated acceptable intrarater and interrater reliability, along with low-to-moderate associations with three-dimensional motion capture. The Medial SOAR test has the potential to provide a reliable and accurate assessment of closed chain hip adduction.


Asunto(s)
Articulación de la Cadera , Rango del Movimiento Articular , Humanos , Femenino , Masculino , Reproducibilidad de los Resultados , Estudios Transversales , Rango del Movimiento Articular/fisiología , Articulación de la Cadera/fisiología , Adulto Joven , Artrometría Articular/métodos , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA