Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 223
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am J Transplant ; 24(3): 380-390, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38072122

RESUMEN

Patients with severe heart disease may have coexisting liver disease from various causes. The incidence of combined heart-liver transplant (CHLT) is increasing as more patients with congenital heart disease survive to adulthood and develop advanced heart failure with associated liver disease from chronic right-sided heart or Fontan failure. However, the criteria for CHLT have not been established. To address this unmet need, a virtual consensus conference was organized on June 10, 2022, endorsed by the American Society of Transplantation. The conference represented a collaborative effort by experts in cardiothoracic and liver transplantation from across the United States to assess interdisciplinary criteria for liver transplantation in the CHLT candidate, surgical considerations of CHLT, current allocation system that generally results in the liver following the heart for CHLT, and optimal post-CHLT management. The conference served as a forum to unify criteria between the different specialties and to forge a pathway for patients who may need dual organ transplantation. Due to the continuing shortage of available donor organs, ethical issues related to multiorgan transplantation were also debated. The findings and consensus statements are presented.


Asunto(s)
Trasplante de Corazón , Hepatopatías , Trasplante de Hígado , Humanos , Corazón
2.
Artif Organs ; 47(3): 574-581, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36305735

RESUMEN

BACKGROUND: Invasive hemodynamic variables obtained from right heart catheterization have been used for risk-stratifying patients with advanced heart failure (HF). However, there is a paucity of data on the prognostic value of invasive hemodynamic variables in patients with left ventricular assist devices (LVAD). We hypothesized that cardiac power output (CPO), cardiac power efficiency (CPE), and left ventricular stroke work index (LVSWI) can serve as prognostic markers in patients with LVADs. METHODS: Baseline hemodynamic data from patients who had LVAD ramp studies at our institution from 4/2014 to 7/2018 were prospectively collected, from which advanced hemodynamic variables (CPO, CPE, and LVSWI) were retrospectively analyzed. Univariate and multivariable analyses were performed for hemocompatibility-related adverse events (HRAE), HF admissions, and mortality. RESULTS: Ninety-one participants (age 61 ± 11 years, 34% women, 40% Black or African American, and 38% ischemic cardiomyopathy) were analyzed. Low CPE was significantly associated with mortality (HR 2.42, 95% CI 1.02-5.74, p = 0.045) in univariate analysis and Kaplan-Meier analysis (p = 0.04). Low LVSWI was significantly associated with mortality (HR 2.13, 95% CI 1.09-4.17, p = 0.03) in univariate analysis and Kaplan-Meier analysis (p = 0.02). CPO was not associated with mortality. CPO, CPE, and LVSWI were not associated with HRAE or HF admissions. CONCLUSIONS: Advanced hemodynamic variables can serve as prognostic indicators for patients with LVADs. Low CPE and LVSWI are prognostic for higher mortality, but no variables were associated with HF admissions or HRAEs.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Pronóstico , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Hemodinámica , Gasto Cardíaco
3.
N Engl J Med ; 380(17): 1618-1627, 2019 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-30883052

RESUMEN

BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Diseño de Prótesis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Femenino , Corazón Auxiliar/efectos adversos , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/estadística & datos numéricos , Accidente Cerebrovascular/etiología
4.
Hepatology ; 73(4): 1464-1477, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32559317

RESUMEN

BACKGROUND AND AIMS: There are more adults than children living with congenital heart disease (CHD) in the United States, with a growing proportion requiring heart-liver transplantation (HLT). Our aim was to ascertain the frequency, outcomes, and prognostic factors in this patient population. APPROACH AND RESULTS: United Network for Organ Sharing data on adult patients who underwent heart transplantation (HT) from 2009 through March 2020 were analyzed. The primary study outcome was patient survival. Cox proportional-hazards modeling assessed for mortality associations. There were 1,084 HT recipients: 817 (75.4%) CHD HTs only, 74 (6.8%) CHD HLTs, 179 (16.5%) non-CHD HLTs, and 14 (1.3%) heart-liver-kidney transplants. The number of CHD HLTs increased from a prior rate of 4/year to 21/year in 2019. Among patients with CHD, the 5-year survival rates were 74.1% and 73.6% in HTs only and HLTs, respectively (P = 0.865). There was a higher rate of allograft failure attributable to rejection in CHD HTs only compared with CHD HLTs (3.2% versus 0.4%; P = 0.014). Only 25 out of 115 HT-performing hospitals undertook CHD HLTs. Higher-volume centers (averaging one CHD HLT per year) had a 5-year patient survival rate of 83.0% compared with 61.3% in lower-volume centers (P = 0.079). Among HLT recipients, total bilirubin (hazard ratio [HR], 1.06; 95% confidence interval [CI], 1.01-1.12) and diabetes (HR = 2.97, 95% CI = 1.21-7.31) were independently associated with increased mortality risk, whereas CHD and age were not. CONCLUSIONS: The rate of HLT for adult CHD in the United States is rising dramatically. The survival outcomes between CHD HT only and CHD HLT groups are comparable; however, the HLT group had lower rates of acute rejection. Among HLT recipients, diabetes and elevated bilirubin are associated with increased posttransplant mortality risk. An average of one CHD HLT per year could be considered a minimum quality metric at transplant centers.


Asunto(s)
Cardiopatías Congénitas/cirugía , Trasplante de Corazón/mortalidad , Trasplante de Corazón/métodos , Trasplante de Hígado/mortalidad , Trasplante de Hígado/métodos , Evaluación de Resultado en la Atención de Salud , Adulto , Bilirrubina/sangre , Complicaciones de la Diabetes/mortalidad , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/sangre , Cardiopatías Congénitas/epidemiología , Trasplante de Corazón/tendencias , Humanos , Trasplante de Hígado/tendencias , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Tasa de Supervivencia , Donantes de Tejidos , Receptores de Trasplantes , Trasplante Homólogo/métodos , Trasplante Homólogo/mortalidad , Trasplante Homólogo/tendencias , Estados Unidos/epidemiología , Adulto Joven
5.
Clin Transplant ; 36(4): e14586, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35041226

RESUMEN

BACKGROUND: Until recently, combined heart-liver-kidney transplantation was considered too complex or too high-risk an option for patients with end-stage heart failure who present with advanced liver and kidney failure as well. AIMS: The objective of this paper is to present our institution's best practices for successfully executing this highly challenging operation. At our institution, referral patterns are most often initiated through the cardiac team. RESULTS: Determinants of successful outcomes include diligent multidisciplinary patient selection, detailed perioperative planning, and choreographed care transition and coordination among all transplant teams. The surgery proceeds in three distinct phases with three different teams, linked seamlessly in planned handoffs. The selection and perioperative care are executed with determined collaboration of all of the invested care teams. CONCLUSIONS: Combined heart-liver-kidney transplantation can be successfully done by careful selection, coordination, and execution.


Asunto(s)
Trasplante de Corazón , Trasplante de Riñón , Trasplante de Hígado , Trasplante de Corazón/efectos adversos , Humanos , Hígado , Trasplante de Hígado/efectos adversos , Estudios Retrospectivos
6.
Heart Vessels ; 37(12): 1995-2001, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35794489

RESUMEN

OBJECTIVES: The purpose of this study is to investigate the early and late outcomes of axillary intra-aortic balloon pump (IABP) implantation as a bridge to heart transplantation, comparing the grafted technique with the percutaneous technique. METHODS: Between July 2009 and January 2020, 163 patients underwent an axillary IABP insertion as a bridge to heart transplantation. Among them, 97 patients underwent axillary IABP implantation through a graft sutured onto the axillary artery (Group A) and 66 patients underwent percutaneously (Group B). Propensity matching identified 53 matched pairs for analysis (C-statistics 0.741). The primary outcomes of interest included IABP-related complications, success rate of a bridge to transplantation, in-hospital mortality, and late survival. RESULTS: In the propensity-score matched cohort, there were no significant differences in the baseline characteristics between the two groups. The operation time was significantly longer in Group A than in Group B (141.5 ± 38.3 min vs 42.7 ± 19.3 min, p < 0.01). The complication rates including stroke, re-exploration for bleeding, and aortic event were not significantly different between Group A and B. However, Group A required more transfusion and re-exploration for bleeding. The success rate of a bridge to transplantation was similar between Group A (47/53, 88.7%) and Group B (47/53, 88.7%). There were no significant differences in in-hospital mortality and late survival between two groups. CONCLUSION: In the propensity score matching analysis, there were not any significant differences between the two groups in IABP-related complications, in-hospital mortality, and late survival. The percutaneous technique provided a shorter operation time and less requirement of transfusion and re-exploration for bleeding compared to the grafted technique. The percutaneous technique might be favorable when feasible.


Asunto(s)
Trasplante de Corazón , Corazón Auxiliar , Humanos , Puntaje de Propensión , Estudios Retrospectivos , Contrapulsador Intraaórtico/efectos adversos , Resultado del Tratamiento
7.
Heart Vessels ; 37(4): 647-653, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34585275

RESUMEN

We sought to assess the impact of the aortic root geometry on developing de novo aortic insufficiency (AI) in patients undergoing left ventricular assist device (LVAD). In total, 114 patients underwent LVAD implantation between February 2016 and January 2020 were included in this study (HeartMate3 N = 68, HeartWare N = 46). Significant aortic insufficiency was defined as mild-to-moderate or greater in echocardiography. The cohort was divided into two groups; those who developed significant AI (Group AI: n = 13) and did not (Group non-AI: n = 101). The primary outcomes of interest included late survival and predictors for significant AI. The patients in Group AI were older than Group non-AI (62.6 ± 11.9 vs 51.3 ± 14.0 years, p < 0.01). The diameter of proximal ascending aorta in Group AI was larger than Group non-AI (31.0 ± 5.0 vs 27.4 ± 4.3 mm, p < 0.01). Aortic valve remained closed in 53.8% in Group AI and 36.6% in Group non-AI (p = 0.24). The late survival was not significantly different between the groups (67.1% vs 76.0% at 3 years, log rank = 0.97). The Cox hazard model showed that larger proximal ascending aortic diameter/BSA (HR 1.55, CI 1.19-2.04, p < 0.01) and not-opening aortic valve (HR 4.73, CI 1.43-16.9, p = 0.01) were independent risk factors for significant AI. The cutoff value of proximal ascending aortic diameter/BSA was 15.5 (area under curve: 0.770, sensitivity: 0.69, specificity: 0.79). Dilated proximal ascending aorta at the time of LVAD surgery and not-opening aortic valve during follow-up were associated with the incidence of de novo significant AI.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Corazón Auxiliar , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Corazón Auxiliar/efectos adversos , Humanos , Incidencia , Estudios Retrospectivos , Función Ventricular Izquierda
8.
Artif Organs ; 46(8): 1626-1635, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35230709

RESUMEN

BACKGROUND: Patients with concomitant anemia and congestive heart failure have poor outcomes. The prevalence and clinical risk of anemia in patients receiving durable left ventricular assist devices (LVAD) remain unknown. METHODS: We retrospectively analyzed patients who underwent LVAD implantation between 2014 and 2018. The association between hemoglobin level at the time of index discharge and the one-year composite endpoint of heart failure readmissions or hemocompatibility-related adverse events was investigated. RESULTS: A total of 168 patients (57 [48, 66] years old, 123 males) were included and stratified into a classification of anemia (hemoglobin <9.7 g/dl, N = 99) or non-anemia (N = 69). The anemia group had a higher one-year incidence of the composite endpoint (56% vs 36%, p = .013) with an adjusted hazard ratio of 1.83 (95% confidence interval 1.08-2.82). Patients with anemia also experienced suboptimal bi-ventricular unloading. CONCLUSIONS: Anemia was prevalent in LVAD patients and associated with a greater risk of heart failure and hemocompatibility-related adverse events. The optimal threshold for therapeutic intervention in response to post-LVAD anemia needs further investigation.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Anciano , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
9.
Ann Vasc Surg ; 83: 42-52, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34995740

RESUMEN

OBJECTIVE: Axillary Intra-aortic balloon pump (IABP) has been increasingly utilized for hemodynamic support in heart failure patients. Vascular complications associated with axillary IABP such as dissection or rupture are relatively rare but not negligible that could negatively affect clinical outcomes. We summarized our experiences. METHODS: This is a retrospective study reviewing of all patients receiving an axillary IABP between June 2016 and November 2020. A total of 199 patients underwent percutaneous axillary IABP placement. 6 patients (6/199, 3.0%) were complicated with arterial/aortic dissection or rupture during the procedures or the course of treatment. We described their clinical presentations and outcomes. RESULTS: Vascular complications included acute type A aortic dissection in 2 patients, descending aortic rupture in 1 patient, abdominal aortic rupture along with type B aortic dissection in 1 patient, and the localized left subclavian artery dissection in 2 patient. 2 type A aortic dissection cases were surgically treated: 1 with emergent left ventricle assist device and ascending aorta replacement, the other with emergent left ventricle assist device. Emergent endovascular treatment was successfully performed in 2 aortic rupture cases. The left subclavian artery dissection cases were managed medically. The postoperative/treatment course was uneventful in all patients. CONCLUSION: Percutaneous axillary IABP therapy can cause significant vascular complications. Early diagnosis and prompt treatment would be the key to improve the clinical outcomesv.


Asunto(s)
Disección Aórtica , Rotura de la Aorta , Corazón Auxiliar , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/etiología , Rotura de la Aorta/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
10.
Artif Organs ; 2022 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-36574590

RESUMEN

PURPOSE: Tolvaptan, a selective vasopressin type-2 antagonist, has been shown to increase serum sodium (Na) and urine output in hyponatremic left ventricular assist device (LVAD) patients in retrospective studies. In this prospective randomized pilot study, we aimed to assess the efficacy of tolvaptan in this population. METHODS: We conducted a prospective, randomized, non-blinded pilot study of LVAD recipients with post-operative hyponatremia (Na < 135 mEq/L) (NCT05408104). Eligible participants were randomized to receive tolvaptan 15 mg daily in addition to usual care versus usual care alone. The primary outcome was a change in Na level and estimated glomerular filtration rate (eGFR), from the first post-operative day of hyponatremia (the day of randomization) to discharge. RESULTS: A total of 33 participants were enrolled, and 28 underwent randomization (median age 55 [IQR 50-62]), 21% women, 54% Black, 32% ischemic cardiomyopathy, median baseline Na 135 (IQR 134-138). Fifteen participants were randomized to tolvaptan (TLV) and 13 were randomized to usual care alone (No-TLV). Mean change in Na from randomization to discharge in the TLV group was 2.7 mEq/L (95%CI 0.7-4.7, p = 0.013) and 1.8 (95%CI 0.5-4.0, p = 0.11) in the No-TLV group, though baseline and final Na levels were similar between groups. The mean change in eGFR was 2.6 ml/min/1.73 m2 (95%CI 10.1-15.3, p = 0.59) in TLV versus 7.5 ml/min/1.73 m2 (95%CI 5.2-20.2, p = 0.15) in No-TLV. TLV participants had significantly more urine output than No-TLV patients during their first 24 h after randomization (3294 vs 2155 ml, p = 0.043). CONCLUSION: TLV significantly increases urine output, with nominal improvement in Na level, in hyponatremic post-operative LVAD patients without adversely impacting renal function.

11.
J Card Surg ; 37(12): 5011-5018, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36349705

RESUMEN

BACKGROUND: The Organ Care System (OCS) is a revolutionary ex vivo organ perfusion technology that can potentially expand the organ retrieval range. The OCS Lung device uses packed red blood cells (pRBC) with a proprietary solution. We report the ability to reduce blood waste during this procedure by using a thermal packaging solution in conjunction with the OCS platform. METHODS: We retrospectively reviewed all OCS Lung recoveries performed by our recovery team, using pRBCfrom May 2019 to January 2021. Initially, units were stored using passive refrigeration with the Performance cooler at a temperature range of 1-6°C for 4 h. Subsequently, thermal control technology with the ProMed cooler was utilized to maintain the same temperature range for 72 h. RESULTS: Twenty-three recoveries were initiated with 63 pRBC. The Performance cooler was used for 8, while the ProMed cooler for 13. 37.5% of pRBC transported with the Performance cooler was used within the validated time range, while 25.0% were used beyond the validated time range based on clinical judgment. In addition, 37.5% of pRBC transported with the Performance cooler were returned to the institution after canceled recoveries with an estimated loss of $1800; the ProMed cooler had no wastage. CONCLUSIONS: This study showed that using an advanced thermal packaging solution facilitates proper storage of pRBC and represents an advancement for extended donor lung preservation. The elimination of blood wastage in this initial study portends ongoing benefits for the limited blood supply and reduced cost.


Asunto(s)
Trasplante de Pulmón , Preservación de Órganos , Humanos , Preservación de Órganos/métodos , Estudios Retrospectivos , Pulmón , Circulación Extracorporea , Trasplante de Pulmón/métodos , Perfusión/métodos
12.
Heart Surg Forum ; 25(1): E152-E154, 2022 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-35238299

RESUMEN

We present two cases of successful surgical correction of a HeartMate 3 left ventricular assist device (LVAD) outflow graft twisting through a subcostal approach. These twistings were diagnosed with computed tomography or pull-back pressure measurement. Technically, a subcostal approach allowed us to access directly the twisted outflow graft and the device connector in a less invasive fashion as compared with a re-sternotomy. Diagnostic modality and surgical tips that address graft twisting are presented within the discussion of these two case studies. The institutional review board of our institution approved this study and waived the requirement for informed consent.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/cirugía , Humanos , Complicaciones Posoperatorias , Estudios Retrospectivos , Esternotomía/métodos
13.
Int Heart J ; 63(1): 56-61, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35095077

RESUMEN

Optimal heart rate (HR) is a promising therapeutic target in patients with heart failure with reduced ejection fraction. Nevertheless, the implication of optimal HR in patients with left ventricular assist devices (LVAD) remains unknown. The cohort included consecutive patients with sinus rhythm undergoing LVAD implantation between 2014 and 2018. Ideal HR was calculated as follows: 93 - 0.13 × (deceleration time [msec]). The impact of "HR difference," defined as an HR difference between the actual HR at discharge and the calculated ideal HR, on the 1-year mortality and heart failure readmissions was investigated. A total of 143 patients (55 years old, 101 men) was identified and tertiled considering their HR differences: (1) the optimal HR group (n = 49; HR difference < 27 bpm), (2) the suboptimal HR group (n = 47; HR difference = 27-42 bpm), and (3) the nonoptimal HR group; HR difference (n = 47; HR difference > 43 bpm). The nonoptimal HR group had a significantly higher 1-year cumulative incidence of the primary endpoint compared with the optimal HR group (38% versus 16%, P = 0.029) with a hazard ratio of 1.69 (95% confidence interval 1.02-2.57) adjusted for 6 potential confounders. In conclusion, nonoptimized HR negatively affected clinical outcomes in LVAD patients. The implication of deceleration time-guided HR optimization in LVAD patients should be further investigated.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca/fisiología , Corazón Auxiliar , Adulto , Anciano , Estudios de Cohortes , Femenino , Insuficiencia Cardíaca/mortalidad , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Prueba de Estudio Conceptual , Volumen Sistólico/fisiología , Tasa de Supervivencia , Resultado del Tratamiento
14.
N Engl J Med ; 378(15): 1386-1395, 2018 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-29526139

RESUMEN

BACKGROUND: In an early analysis of this trial, use of a magnetically levitated centrifugal continuous-flow circulatory pump was found to improve clinical outcomes, as compared with a mechanical-bearing axial continuous-flow pump, at 6 months in patients with advanced heart failure. METHODS: In a randomized noninferiority and superiority trial, we compared the centrifugal-flow pump with the axial-flow pump in patients with advanced heart failure, irrespective of the intended goal of support (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke (with disabling stroke indicated by a modified Rankin score of >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove a malfunctioning device. The noninferiority margin for the risk difference (centrifugal-flow pump group minus axial-flow pump group) was -10 percentage points. RESULTS: Of 366 patients, 190 were assigned to the centrifugal-flow pump group and 176 to the axial-flow pump group. In the intention-to-treat population, the primary end point occurred in 151 patients (79.5%) in the centrifugal-flow pump group, as compared with 106 (60.2%) in the axial-flow pump group (absolute difference, 19.2 percentage points; 95% lower confidence boundary, 9.8 percentage points [P<0.001 for noninferiority]; hazard ratio, 0.46; 95% confidence interval [CI], 0.31 to 0.69 [P<0.001 for superiority]). Reoperation for pump malfunction was less frequent in the centrifugal-flow pump group than in the axial-flow pump group (3 patients [1.6%] vs. 30 patients [17.0%]; hazard ratio, 0.08; 95% CI, 0.03 to 0.27; P<0.001). The rates of death and disabling stroke were similar in the two groups, but the overall rate of stroke was lower in the centrifugal-flow pump group than in the axial-flow pump group (10.1% vs. 19.2%; hazard ratio, 0.47; 95% CI, 0.27 to 0.84, P=0.02). CONCLUSIONS: In patients with advanced heart failure, a fully magnetically levitated centrifugal-flow pump was superior to a mechanical-bearing axial-flow pump with regard to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755 .).


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Diseño de Prótesis , Adulto , Anciano , Anciano de 80 o más Años , Presión Sanguínea , Femenino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Calidad de Vida , Reoperación/estadística & datos numéricos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Trombosis/etiología , Resultado del Tratamiento , Prueba de Paso
15.
Ann Vasc Surg ; 72: 663.e9-663.e13, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33285271

RESUMEN

BACKGROUND: Demographics are shifting toward an increasingly older population in the United States; thus, it is imperative that patients with a complex cardiovascular history are approached in a systematic fashion. Currently, there is no clear protocol on how best to manage elderly patients who present with both severe coronary artery disease and symptomatic carotid stenosis. For cardiac patients with severe, asymptomatic, high-grade carotid artery stenosis, there may be even more of a conundrum. Although most centers would tend to manage the asymptomatic carotid stenosis expectantly, it is well known that patients with severe, uncorrected internal carotid artery disease are at an increased risk of experiencing a cerebrovascular accident during coronary artery bypass grafting (CABG). One approach that has been recognized in other settings as a cost-effective strategy to stabilize high-risk elderly patients preoperatively is the use of an intra-aortic balloon pump (IABP). To better understand the best approach to take in these patients with concomitant disease, we analyzed the outcomes of 4 patients who underwent placement of an IABP before carotid endarterectomy (CEA) as a bridge to CABG. METHODS: Between 2017 and 2019, 4 patients presented with multivessel symptomatic coronary artery disease and greater than 90% stenosis of at least one internal carotid artery and underwent either staged or simultaneous CEA and CABG. There was placement of an IABP in all patients before the CEA. Time to CABG ranged from a simultaneous procedure to 23 days after CEA. RESULTS: The only death within 30-day postoperation involved the patient who had CEA and CABG performed simultaneously. None of the surviving patients experienced a myocardial infarction. Two of the 4 patients experienced acute kidney injury after surgery, and one patient developed atrial fibrillation postoperatively. None of the patients experienced a postoperative neurological complication. In addition, there were no access site complications associated with IABP placement. CONCLUSIONS: A staged procedure with placement of an IABP can be successfully used in carefully selected patients presenting with concomitant severe carotid and coronary artery disease who will undergo surgical management of their disease. The stabilization provided by IABP was potentially protective against adverse postoperative events and appeared to allow for flexibility in the time between CEA to CABG for patients. Additional studies are necessary to further understand the impact of such an approach.


Asunto(s)
Arteria Carótida Interna/cirugía , Estenosis Carotídea/cirugía , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Endarterectomía Carotidea , Contrapulsador Intraaórtico , Anciano , Anciano de 80 o más Años , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/fisiopatología , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/fisiopatología , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
16.
Artif Organs ; 45(6): 587-592, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33236371

RESUMEN

Worsening systemic congestion is often the central trigger of hospitalization in patients with heart failure. However, accurate assessment of congestion is challenging. The prognostic impact of systemic congestion following durable continuous-flow left ventricular assist device (LVAD) implantation remains unknown. Consecutive patients who received durable continuous-flow LVAD implantation between January 2014 and June 2017 and were followed for 1 year were included. The association of preoperative plasma volume status, which was calculated using patients' body weight and hematocrit and expressed as a deviation from ideal plasma volume, with 1-year mortality following LVAD implantation was investigated. In total, 186 patients (median 57 years and 138 males) were included. Baseline plasma volume status was -30.1% (-37.1%, -19.4%) on median. Eighty-eight patients (47%) had higher plasma volume status (>-29.8%), and their 1-year survival was significantly lower than those without (67% vs. 87%, P = .001). High plasma volume status was an independent predictor of 1-year death with an adjusted hazard ratio of 4.52 (95% confidence interval 1.52-13.5). Baseline systemic congestion, as defined by the high plasma volume status, was associated with higher mortality following durable continuous-flow LVAD implantation. The implication of improving preoperative plasma volume remains an area of needed investigation.


Asunto(s)
Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Corazón Auxiliar , Volumen Plasmático , Anciano , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia
17.
Artif Organs ; 45(3): 297-302, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33098153

RESUMEN

Aortic insufficiency remains a difficult to treat and highly morbid condition even in the era of HeartMate 3 left ventricular assist devices (LVADs). The prognostic nature of the longitudinal progression of aortic insufficiency, however, remains unknown. We prospectively collected data on patients who received HeartMate 3 LVAD implantation, who had assessments of aortic insufficiency using a novel Doppler echocardiography obtained at outflow graft at three (baseline) and 6 months postimplant. Patients with moderate or greater aortic insufficiency at baseline were excluded. The risk of aortic insufficiency progression on 1-year death and readmission for heart failure was investigated. In total, 41 patients (median 51 years old and 29 males) were included. All patients had less than moderate aortic insufficiency at baseline. Of them, 22 patients had worsening aortic insufficiency for 3 months following baseline assessments, which was associated with a significantly higher risk of 1-year death or heart failure readmission rate (41% vs. 11%, P = .023) with a hazard ratio of 3.24 (95% confidence interval 1.02-18.5, P = .038) adjusted for device speed at baseline and destination therapy indication. In patients with HeartMate 3 LVADs, progressive aortic insufficiency may be associated with a higher risk of 1-year death or readmission for heart failure. Close monitoring of patients with baseline aortic insufficiency should be considered as a measure to risk-stratify those for future adverse events.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Complicaciones Posoperatorias/diagnóstico , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Progresión de la Enfermedad , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Readmisión del Paciente/estadística & datos numéricos , Complicaciones Posoperatorias/etiología , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Estudios Retrospectivos , Índices de Gravedad del Trauma , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
18.
J Card Surg ; 36(9): 3250, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34145640

RESUMEN

Predicted heart mass matches donor and recipient sizing for heart transplantation. Physiologic considerations further refines matching and can allow for safe use of undersized and sex mismatched organs.


Asunto(s)
Trasplante de Corazón , Benchmarking , Humanos , Tamaño de los Órganos , Estudios Retrospectivos , Donantes de Tejidos
19.
J Card Surg ; 36(3): 1159-1161, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33533108

RESUMEN

Unplanned readmissions frequently occur following the implantation of a durable left ventricular assist device (LVAD) due to complications such as gastrointestinal bleeding and driveline infection. There is a paucity of literature describing the incidence of unplanned readmission in patients with a HeartMate 3 (HM3) Left Ventricular Assist System. In this report, we present the successful outcome of a patient with an HM3 LVAD who has experienced no unplanned readmissions in the 4-year post-implant phase. To our knowledge, this is the longest readmission-free case after HM3 implantation. A successful patient outcome was enabled by the use of the modular HM3 device, the postoperative prescription of beta-blockers and omega-3, the presence of strong social support, and open communication between the patient's caregivers and the LVAD team. Reducing the instance of unplanned readmission confers clinical benefits to the patient, as well as reducing the cost burden on the patient and the healthcare system.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Periodo Posoperatorio , Estudios Retrospectivos
20.
Perfusion ; 36(5): 463-469, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32909513

RESUMEN

BACKGROUND: Recently, del Nido cardioplegia solution (DN) has been utilized in adult cardiac surgery. However, adequate interval of maintenance dose(s) is still unclear. The purpose of this study was to assess the safety and efficacy of our DN protocol by comparing with conventional cold whole blood cardioplegia (CWB). METHODS: A total of 1003 consecutive patients (DN group, N = 350 vs. CWB group, N = 653) underwent cardiovascular surgery between July 2013 and September 2018 were included in this study. The DN protocol was to administer 1000 to 1200 ml as an initial dose and to add maintenance dose(s) (500 ml each) every 60 minutes when the estimated cross-clamp time was over 90 minutes. CWB was given every 20 minutes, regardless of cross-clamp time. Propensity matching identified 254 matched pairs for analysis. The preoperative and postoperative data were reviewed. RESULTS: Cross-clamp time was significantly shorter in the DN group compared with the CWB group (107 ± 56 minutes vs. 116 ± 49 minutes, p = 0.0458). A retrograde cannula was used in 124 (48.8%) patients in the DN group and 181 (71.3%) patients in the CWB group (p < 0.0001). There were no significant differences in requiring postoperative cardiac supports (inotropes, mechanical circulatory supports) and major complications. In-hospital mortality was similar between two groups (DN group: 3.2% vs. CWB group: 2.4%, p = 0.5872). CONCLUSIONS: Short-term clinical outcomes in the patients underwent cardiovascular surgery with the DN protocol including the redosing interval strategy were acceptable. Also, DN protocol was associated with shortened cross-clamp time and less usage of the retrograde cannula.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Soluciones Cardiopléjicas , Adulto , Soluciones Cardiopléjicas/uso terapéutico , Paro Cardíaco Inducido , Humanos , Periodo Posoperatorio , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA