Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Med Educ ; 24(1): 811, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39075429

RESUMEN

BACKGROUND: Point-of-care ultrasound (POCUS) is steadily growing in use in prehospital emergency medicine. While currently used primarily by emergency physicians, POCUS could also be employed by paramedics to support diagnosis and decision-making. Yet to date, no paramedicine-targeted POCUS curricula exist in Germany. Furthermore, given time and resource constraints in paramedic training, it is unclear whether paramedics could feasibly learn POCUS for prehospital deployment. Hence, this study outlines the development and implementation of a comprehensive POCUS curriculum for paramedics. Through this curriculum, we investigate whether paramedics can attain proficiency in POCUS comparable to other user groups. METHODS: In this prospective observational study, we first developed a blended learning-based POCUS curriculum specifically for paramedics, focusing on basic principles, the RUSH-Protocol and ultrasound guided procedures. Participants underwent digital tests to measure their theoretical competence before (T1) and after the digital preparation phase (T2), as well as at the end of the on-site phase (T3). At time point T3, we additionally measured practical competence using healthy subjects and simulators. We compared the theoretical competence and the practical competence on a simulator with those of physicians and medical students who had also completed ultrasound training. Furthermore, we carried out self-assessment evaluations, as well as evaluations of motivation and curriculum satisfaction. RESULTS: The paramedic study group comprised n = 72 participants. In the theoretical test, the group showed significant improvement between T1 and T2 (p < 0.001) and between T2 and T3 (p < 0.001). In the practical test on healthy subjects at T3, the group achieved high results (87.0% ± 5.6). In the practical test on a simulator at T3, paramedics (83.8% ± 6.6) achieved a lower result than physicians (p < 0.001), but a comparable result to medical students (p = 0.18). The results of the study group's theoretical tests (82.9% ± 9.2) at time point T3 were comparable to that of physicians (p = 0.18) and better than that of medical students (p < 0.01). The motivation and attitude of paramedics towards the prehospital use of POCUS as well as their self-assessment significantly improved from T1 to T3 (p < 0.001). The overall assessment of the curriculum was positive (92.1 ± 8.5). CONCLUSION: With our tailored curriculum, German paramedics were able to develop skills in POCUS comparable to those of other POCUS learners. Integration of POCUS into paramedics' training curricula offers opportunities and should be further studied.


Asunto(s)
Competencia Clínica , Curriculum , Sistemas de Atención de Punto , Ultrasonografía , Adulto , Femenino , Humanos , Masculino , Auxiliares de Urgencia/educación , Medicina de Emergencia/educación , Alemania , Paramédico/educación , Estudios Prospectivos
2.
Laryngorhinootologie ; 2024 Jun 03.
Artículo en Alemán | MEDLINE | ID: mdl-38830381

RESUMEN

OBJECTIVE: Upper airway obstructions are usually acute emergencies. Coniotomy is the last option to secure the airway and can be supported by sonography. The aim of this study was to establish a training program to teach these skills. MATERIAL AND METHODS: The training consisted of theoretical training with an additional video presentation (10 minutes each) and practical training (45 minutes). Evaluations were completed before (T1) and after (T2) the training to measure prior experience and satisfaction with the training as well as subjective and objective competence levels. At T2, a practical test was also completed by n=113 participants. A standardized evaluation form was used to document the results of the practical test. RESULTS: A large proportion of the participants had neither seen a coniotomy (64.6%) nor performed one independently (79.6%). Significant improvement (T1 to T2) was measured with regard to the subjective assessment of competence (p<0.001). The training received positive ratings for all items tested (scale ranges 1-2). During practical tests, the participants achieved an average of 89.2% of the possible points and needed a mean of 101 ±23 seconds to identify the conic ligament. CONCLUSION: Structured training for sonographic identification of the conic ligament leads to significant improvement in the subjective assessment of competence and a high objective competence level in a short period of time. This type of training should be standardized in head and neck ultrasound training in the future.

3.
Diagnostics (Basel) ; 14(1)2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38201363

RESUMEN

BACKGROUND: the use of handheld ultrasonography (HHUS) devices is well established in prehospital emergency diagnostics, as well as in intensive care settings. This is based on several studies in which HHUS devices were compared to conventional high-end ultrasonography (HEUS) devices. Nonetheless, there is limited evidence regarding potential variations in B-scan quality among HHUS devices from various manufacturers, and regarding whether any such differences hold clinical significance in intensive care medicine settings. METHODS: this study included the evaluation of eight HHUS devices sourced from diverse manufacturers. Ultrasound videos of five previously defined sonographic questions (volume status/inferior vena cava, pleural effusion, pulmonary B-lines, gallbladder, and needle tracking in situ) were recorded with all devices. The analogue recording of the same pathologies with a HEUS device served as gold standard. The corresponding findings (HHUS and HEUS) were then played side by side and evaluated by sixteen intensive care physicians experienced in sonography. The B-scan quality and the clinical significance of the HHUS were assessed using a five-point Likert scale (5 points = very good; 1 point = insufficient). RESULTS: both in assessing the quality of B-scans and in their ability to answer clinical questions, the HHUS achieved convincing results-regardless of the manufacturer. For example, only 8.6% (B-scan quality) and 9.8% (clinical question) of all submitted assessments received an "insufficient" rating. One HHUS device showed a significantly higher (p < 0.01) average points score in the assessment of B-scan quality (3.9 ± 0.65 points) and in the evaluation of clinical significance (4.03 ± 0.73 points), compared to the other devices. CONCLUSIONS: HHUS systems are able to reliably answer various clinical intensive care questions and are-while bearing their limitations in mind-an acceptable alternative to conventional HEUS devices. Irrespective of this, the present study was able to demonstrate relevant differences in the B-scan quality of HHUS devices from different manufacturers.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA