Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
Biomech Model Mechanobiol ; 18(4): 983-1004, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30834463

RESUMEN

Non-negligible postinterventional complication rates after endovascular aneurysm repair (EVAR) leave room for further improvements. Since the potential success of EVAR depends on various patient-specific factors, such as the complexity of the vessel geometry and the physiological state of the vessel, in silico models can be a valuable tool in the preinterventional planning phase. A suitable in silico EVAR methodology applied to patient-specific cases can be used to predict stent-graft (SG)-related complications, such as SG migration, endoleaks or tissue remodeling-induced aortic neck dilatation and to improve the selection and sizing process of SGs. In this contribution, we apply an in silico EVAR methodology that predicts the final state of the deployed SG after intervention to three clinical cases. A novel qualitative and quantitative validation methodology, that is based on a comparison between in silico results and postinterventional CT data, is presented. The validation methodology compares average stent diameters pseudo-continuously along the total length of the deployed SG. The validation of the in silico results shows very good agreement proving the potential of using in silico approaches in the preinterventional planning of EVAR. We consider models of bifurcated, marketed SGs as well as sophisticated models of patient-specific vessels that include intraluminal thrombus, calcifications and an anisotropic model for the vessel wall. We exemplarily show the additional benefit and applicability of in silico EVAR approaches to clinical cases by evaluating mechanical quantities with the potential to assess the quality of SG fixation and sealing such as contact tractions between SG and vessel as well as SG-induced tissue overstresses.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Simulación por Computador , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Presión Sanguínea/fisiología , Prótesis Vascular , Humanos , Reproducibilidad de los Resultados , Stents , Tomografía Computarizada por Rayos X
3.
Biomech Model Mechanobiol ; 17(4): 1139-1164, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29752606

RESUMEN

Endovascular aneurysm repair (EVAR) can involve some unfavorable complications such as endoleaks or stent-graft (SG) migration. Such complications, resulting from the complex mechanical interaction of vascular tissue, SG and blood flow or incompatibility of SG design and vessel geometry, are difficult to predict. Computational vascular mechanics models can be a predictive tool for the selection, sizing and placement process of SGs depending on the patient-specific vessel geometry and hence reduce the risk of potential complications after EVAR. In this contribution, we present a new in silico EVAR methodology to predict the final state of the deployed SG after intervention and evaluate the mechanical state of vessel and SG, such as contact forces and wall stresses. A novel method to account for residual strains and stresses in SGs, resulting from the precompression of stents during the assembly process of SGs, is presented. We suggest a parameter continuation approach to model various different sizes of SGs within one in silico EVAR simulation which can be a valuable tool when investigating the issue of SG oversizing. The applicability and robustness of the proposed methods are demonstrated on the example of a synthetic abdominal aortic aneurysm geometry.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Algoritmos , Aneurisma de la Aorta Abdominal/fisiopatología , Prótesis Vascular , Simulación por Computador , Análisis de Elementos Finitos , Humanos , Modelos Cardiovasculares , Electricidad Estática , Stents , Estrés Mecánico
4.
Ther Clin Risk Manag ; 12: 1841-1847, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28008262

RESUMEN

AIM: Endothelial progenitor cells (EPCs) are primitive cells found in the bone marrow and peripheral blood (PB). In particular, the potential of EPCs to differentiate into mature endothelial cells remains of high interest for clinical applications such as bio-functionalized patches for autologous seeding after implantation. The objective of this study was to determine EPCs' kinetics in patients undergoing carotid artery thromboendarterectomy (CTEA) and patch angioplasty. METHODS: Twenty CTEA patients were included (15 male, mean age 76 years). PB samples were taken at 1 day preoperatively, and at 1, 3, and 5 days postoperatively. Flow cytometric analysis was performed for CD34, CD133, KDR, and CD45. Expression of KDR, SDF-1α, and G-CSF was analyzed by means of enzyme-linked immunosorbent assay. RESULTS: Fluorescence-activated cell sorting analysis revealed 0.031%±0.016% (% of PB mononuclear cells) KDR+ cells and 0.052%±0.022% CD45-/CD34+/CD133+ cells, preoperatively. A 33% decrease of CD45-/CD34+/CD133+ cells was observed at day 1 after surgery. However, a relative number (compared to initial preoperative values) of CD45-/CD34+/CD133+ cells was found on day 3 (82%) and on day 5 (94%) postoperatively. More profound upregulated levels of CD45-CD34+/CD133+ cells were observed for diabetic (+47% compared to nondiabetic) and male (+38% compared to female) patients. No significant postoperative time-dependent differences were found in numbers of KDR+ cells and the concentrations of the cytokines KDR and G-CSF. However, the SDF-1α levels decreased significantly on day 1 postoperatively but returned to preoperative levels by day 3. CONCLUSION: CTEA results in short-term downregulation of circulating EPCs and SDF-1α levels. Rapid return to baseline levels might indicate participation of EPCs in repair mechanisms following vascular injury.

5.
J Cardiothorac Surg ; 8: 188, 2013 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-24007462

RESUMEN

BACKGROUND: Patients suffering from acute type A aortic dissection undergo replacement of the ascending aorta, the proximal hemiarch or complete aortic arch, depending on the extent of the individual pathology. In a subset of these treated patients, secondary pathologies of the distal anastomosis or the remaining distal part of the aorta occur. The treatment of these pathologies is challenging, requiring major surgical re-do procedures with aortic arch replacement under extracorporeal circulation and hypothermic circulatory arrest. METHODS: We report our experience of five patients with complex aortic pathologies after previous aortic surgery treated with a single stage re-do hybrid procedure, consisting of bypass grafting of the supraaortic branches off-pump, stent graft placement for endovascular aortic repair (TEVAR) and surgical debranching of the aortic arch. RESULTS: In all patients the surgical vascular grafts and stent grafts were deployed successfully, there were no intraoperative deaths. Four out of five patients were discharged from hospital in good clinical condition. One patient died postoperatively due to cardiac tamponade. In one patient a type I endoleak persisted leading to occlusion of a bypass branch requiring surgical revision at one year after debranching. CONCLUSION: We discuss the prerequisites, all steps and potential pitfalls of this hybrid aortic arch replacement. The current procedure avoids cardiopulmonary bypass and circulatory arrest, which may benefit early patient outcome; however, patient and device selection plays a key role for immediate success and midterm outcomes. In addition, precise procedural planning and development of customized stents may help to develop this procedure into a true alternative for conventional aortic arch replacement.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Puente de Arteria Coronaria Off-Pump/métodos , Reoperación/métodos , Anciano , Anciano de 80 o más Años , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Stents , Resultado del Tratamiento
6.
Cardiovasc Intervent Radiol ; 35(1): 190-3, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21735325

RESUMEN

Malignancies of the aortic wall represent a rare condition, and only a few reports have covered cases of sarcomas arising at the site of a prosthesis made of Dacron. A coincidence with endovascular repair has only been reported in one case to date. We report a patient with epithelioid angiosarcoma and metastatic disease, which was found in an aneurysmal sac after endovascular aortic repair for abdominal aortic aneurysm.


Asunto(s)
Aneurisma de la Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/terapia , Implantación de Prótesis Vascular/métodos , Hemangiosarcoma/patología , Anciano de 80 o más Años , Angiografía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Embolización Terapéutica , Resultado Fatal , Fluorodesoxiglucosa F18 , Hemangiosarcoma/diagnóstico por imagen , Humanos , Inmunohistoquímica , Imagen Multimodal , Clasificación del Tumor , Metástasis de la Neoplasia , Tomografía de Emisión de Positrones , Radiofármacos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA