Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 96(31): 12846-12853, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39048518

RESUMEN

Rapid and accurate realization of in situ analysis of deep-sea dissolved gases imperative to the study of ecological geology, oil and gas resource exploration, and global climate change. Herein, we report for the first time the deep-sea dissolved methane (CH4) in situ sensor based on quartz-enhanced photoacoustic and light-induced thermoelastic spectroscopy. The developed sensor system has a volume of φ120 mm × 430 mm and a power consumption of 7.6 W. The sensor, in the manner of frequency division multiplexing, is able to simultaneously measure the photoacoustic signals and light-induced thermoelastic signals, which can accurately correct laser-intensity induced influence on concentration. The spectral response of CH4 concentration varying from 0.01 to 5% is calibrated in detail based on the pressure and temperature in the application environment. The trend of the photoacoustic signal of CH4 at different water molecule (H2O) concentrations is investigated. An Allan variance analysis of several hours demonstrates a minimum detection limit of 0.21 ppm for the CH4 spectrometer. The sensor combined with the gas-liquid separation and enrichment unit is integrated into a compact marine standalone system. Since the specifically designed photoacoustic cell has a volume of only 1.2 mL, the time response for dissolved CH4 detection is reduced to 4 min. Furthermore, the sensor is successfully deployed in the vicinity of the "HaiMa" cold seeps at 1380 m underwater in the South China Sea, completing three consecutive days of measurements of dissolved CH4.

2.
Opt Lett ; 49(4): 1033-1036, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38359246

RESUMEN

Pressure is an important parameter in assessing combustion performance that is typically measured using contact sensors. However, contact sensors usually disturb combustion flows and suffer from the temperature tolerance limit of sensor materials. In this Letter, an innovative noncontact two-color pressure sensing method based on tunable diode laser absorption spectroscopy (TDLAS) is proposed. This makes it possible to measure pressure at high temperature environments for combustion diagnostics. The proposed method uses the linear combination of the collision-broadened linewidths of two H2O absorption lines near 1343 and 1392 nm to measure the pressure. The feasibility and performance of such method have been demonstrated by measuring pressures from 1 to 5 bars at temperatures up to 1300 K with a laser wavelength scanning rate of 20 kHz. Measurement errors were found to be within 3%. Compared to previously reported TDLAS pressure sensors, this method is free from the influence of concentration and can also be combined with the existing two-color TDLAS thermometry to realize a fast, on line, and multi-parameter measurement in combustion diagnostics.

3.
Opt Lett ; 49(11): 3206-3209, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38824364

RESUMEN

In this work, we developed off-plane quartz-enhanced photoacoustic spectroscopy (OP-QEPAS). In the OP-QEPAS the light beam went neither through the prong spacing of the quartz tuning fork (QTF) nor in the QTF plane. The light beam is in parallel with the QTF with an optimal distance, resulting in low background noise. A radial-cavity (RC) resonator was coupled with the QTF to enhance the photoacoustic signal by the radial resonance mode. By offsetting both the QTF and the laser position from the central axis, we enhance the effect of the acoustic radial resonance and prevent the noise generated by direct laser irradiation of the QTF. Compared to IP-QEPAS based on a bare QTF, the developed OP-QEPAS with a RC resonator showed a >10× signal-to-noise ratio (SNR) enhancement. The OP-QEPAS system has great advantages in the use of light emitting devices (LEDs), long-wavelength laser sources such as mid-infrared quantum cascade lasers, and terahertz sources. When employing a LED as the excitation source, the noise level was suppressed by ∼2 orders of magnitude. Furthermore, the radial and longitudinal resonance modes can be combined to further improve the sensor performance.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA