Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Clin Monit Comput ; 38(2): 281-291, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38280975

RESUMEN

We have developed a method to automatically assess LV function by measuring mitral annular plane systolic excursion (MAPSE) using artificial intelligence and transesophageal echocardiography (autoMAPSE). Our aim was to evaluate autoMAPSE as an automatic tool for rapid and quantitative assessment of LV function in critical care patients. In this retrospective study, we studied 40 critical care patients immediately after cardiac surgery. First, we recorded a set of echocardiographic data, consisting of three consecutive beats of midesophageal two- and four-chamber views. We then altered the patient's hemodynamics by positioning them in anti-Trendelenburg and repeated the recordings. We measured MAPSE manually and used autoMAPSE in all available heartbeats and in four LV walls. To assess the agreement with manual measurements, we used a modified Bland-Altman analysis. To assess the precision of each method, we calculated the least significant change (LSC). Finally, to assess trending ability, we calculated the concordance rates using a four-quadrant plot. We found that autoMAPSE measured MAPSE in almost every set of two- and four-chamber views (feasibility 95%). It took less than a second to measure and average MAPSE over three heartbeats. AutoMAPSE had a low bias (0.4 mm) and acceptable limits of agreement (- 3.7 to 4.5 mm). AutoMAPSE was more precise than manual measurements if it averaged more heartbeats. AutoMAPSE had acceptable trending ability (concordance rate 81%) during hemodynamic alterations. In conclusion, autoMAPSE is feasible as an automatic tool for rapid and quantitative assessment of LV function, indicating its potential for hemodynamic monitoring.


Asunto(s)
Monitorización Hemodinámica , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda , Ecocardiografía Transesofágica , Disfunción Ventricular Izquierda/diagnóstico por imagen , Estudios Retrospectivos , Inteligencia Artificial , Válvula Mitral/diagnóstico por imagen
2.
Scand Cardiovasc J ; 57(1): 2181390, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38095169

RESUMEN

BACKGROUND: Myocardial viability assessment adds value to the therapeutic decision-making of patients with ischemic heart disease. In this feasibility study, we investigated whether established echocardiographic measurements of post-systolic shortening (PSS), strain, strain rate and wall motion score (WMS) can discover viable myocardial segments. Our hypothesis is that non-viable myocardial segments are both akinetic and without PSS. METHODS: The study population consisted of 26 examinations strictly selected by visible dysfunction. We assessed WMS, strain by speckle tracking and strain rate by tissue Doppler. The segments (16*26 = 416) were categorized into either normokinetic/hypokinetic or akinetic/dyskinetic and whether there was PSS. The reference method was the presence of scar with segmental percentage volume scar fraction >50%, detected by late gadolinium-enhanced cardiovascular magnetic resonance. Agreement with echocardiography was evaluated by Kappa coefficient. RESULTS: WMS had Kappa coefficient 0.43 (sensitivity 99%, specificity 35%). Kappa coefficient of strain was 0.28 (sensitivity 98%, specificity 23%). By combining PSS in akinetic segments with WMS and strain, the Kappa coefficient was 0.06 and 0.08 respectively. CONCLUSION: Segmental viability was best shown by the presence of systolic function. Post-systolic shortening adds no value to the assessment of segmental myocardial viability.


Asunto(s)
Cicatriz , Isquemia Miocárdica , Humanos , Cicatriz/patología , Miocardio/patología , Ecocardiografía/métodos , Corazón
3.
J Ultrasound Med ; 40(2): 341-350, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32710577

RESUMEN

OBJECTIVES: Handheld ultrasound devices (HUDs) have previously been limited to grayscale imaging without options for left ventricle (LV) quantification. We aimed to study the feasibility and reliability of automatic measurements of mitral annular plane systolic excursion (MAPSE) by HUDs. METHODS: An algorithm that automatically measured MAPSE from live grayscale recordings was implemented in a HUD. Twenty patients at a university hospital were examined by either a cardiologist or a sonographer. Standard echocardiography using a high-end scanner was performed. The apical 4-chamber view was recorded 4 times by both echocardiography and the HUD. MAPSE was measured by M-mode and color tissue Doppler (cTD) during echocardiography and automatically by the HUD. RESULTS: The automatic method underestimated mean MAPSE ± SD versus M-mode (9.6 ± 2.2 versus 10.9 ± 2.6 mm; difference, 1.2 ± 1.4 mm, P < .005). The difference between the automatic and cTD measurements was not significant (0.8 ± 1.8 mm; P = .073). The intraclass correlation coefficients (ICCs) between automatic and M-mode measurements was 0.85, and 0.81 for cTD measurements. There was good agreement between the methods, and the intra- and inter-rater ICCs were excellent for all methods (≥0.86). CONCLUSIONS: In this novel study evaluating automatic quantification of LV longitudinal function by HUD, we showed the high feasibility and reliability of the method. Compared to M-mode imaging, the automatic method underestimated MAPSE by 8% to 10%, but the difference with cTD imaging was nonsignificant. We conclude that this study's method for automatic quantitative assessment of LV function can be integrated in HUDs.


Asunto(s)
Disfunción Ventricular Izquierda , Estudios de Factibilidad , Humanos , Válvula Mitral/diagnóstico por imagen , Proyectos Piloto , Reproducibilidad de los Resultados , Sístole
4.
Acta Anaesthesiol Scand ; 64(8): 1128-1135, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32407541

RESUMEN

BACKGROUND: There is significant uncertainty regarding the timing of onset of cardiovascular stunning after cardiac surgery. Cardiovascular stunning is affecting both contractility (Ees) and arterial load. Arterial load may be represented by arterial elastance (Ea) and participates in ventriculo-arterial coupling through the Ea/Ees ratio, giving information on efficiency and performance. An alternative approach to ventriculo-arterial interaction is oscillatory power fraction (OPF). The aim of this study was to investigate the immediate beat-to-beat effects of on-pump coronary artery bypass graft (CABG) surgery on contractility, cardiac power parameters, arterial load and ventriculo-arterial coupling as well as classical haemodynamic parameters. METHODS: We included 41 patients scheduled for fast-track CABG surgery. Measurements were taken before and after cardiopulmonary bypass. A flow and pressure curve were recorded from transoesophageal pulsed wave Doppler and a radial artery catheter, respectively. This enabled the calculation of stroke work, total cardiac energy delivery, OPF and Ea/Ees ratio. Routine haemodynamic monitoring provided the classical haemodynamic parameters. RESULTS: Immediately after cardiopulmonary bypass there was no firm evidence for alterations in contractility, stroke work, stroke volume or arterial elastance. Ea/Ees ratio and OPF remained unchanged. CONCLUSIONS: There was no evidence for clinically relevant cardiac stunning or altered arterial load immediately after cardiopulmonary bypass for CABG surgery. The unchanged Ea/Ees ratio and OPF are indicating unchanged cardiac efficiency before and after cardiopulmonary bypass. This indicates that in elective CABG patients cardiovascular stunning is perhaps a phenomenon of inflammation and not immediate ischaemia-reperfusion injury or mechanical handling.


Asunto(s)
Gasto Cardíaco/fisiología , Puente Cardiopulmonar , Contracción Miocárdica/fisiología , Anciano , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Estudios Prospectivos , Volumen Sistólico
5.
Sci Rep ; 14(1): 6498, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38499588

RESUMEN

Three-dimensional (3D) images provide a comprehensive view of material microstructures, enabling numerical simulations unachievable with two-dimensional (2D) imaging alone. However, obtaining these 3D images can be costly and constrained by resolution limitations. We introduce a novel method capable of generating large-scale 3D images of material microstructures, such as metal or rock, from a single 2D image. Our approach circumvents the need for 3D image data while offering a cost-effective, high-resolution alternative to existing imaging techniques. Our method combines a denoising diffusion probabilistic model with a generative adversarial network framework. To compensate for the lack of 3D training data, we implement chain sampling, a technique that utilizes the 3D intermediate outputs obtained by reversing the diffusion process. During the training phase, these intermediate outputs are guided by a 2D discriminator. This technique facilitates our method's ability to gradually generate 3D images that accurately capture the geometric properties and statistical characteristics of the original 2D input. This study features a comparative analysis of the 3D images generated by our method, SliceGAN (the current state-of-the-art method), and actual 3D micro-CT images, spanning a diverse set of rock and metal types. The results shown an improvement of up to three times in the Frechet inception distance score, a typical metric for evaluating the performance of image generative models, and enhanced accuracy in derived properties compared to SliceGAN. The potential of our method to produce high-resolution and statistically representative 3D images paves the way for new applications in material characterization and analysis domains.

6.
PLoS One ; 19(2): e0298978, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38349944

RESUMEN

[This corrects the article DOI: 10.1371/journal.pone.0266147.].

7.
Resusc Plus ; 18: 100583, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38404755

RESUMEN

Aim: Current guidelines for cardiopulmonary resuscitation (CPR) recommend a one-size-fits-all approach in relation to the positioning of chest compressions. We recently developed RescueDoppler, a hands-free Doppler ultrasound device for continuous monitoring of carotid blood flow velocity during CPR. The aim of the present study is to investigate whether RescueDoppler via real-time hemodynamic feedback, could identify both optimal and suboptimal compression positions. Methods: In this model of animal cardiac arrest, we induced ventricular fibrillation in five domestic pigs. Manual chest compressions were performed for ten seconds at three different positions on the sternum in random order and repeated six times. We analysed Time Average Velocity (TAV) with chest compression position as a fixed effect and animal, position, and sequential time within animals as random effects. Furthermore, we compared TAV to invasive blood pressure from the contralateral carotid artery. Results: We were able to detect changes in TAV when altering positions. The positions with the highest (range 19 to 48 cm/s) and lowest (6-25 cm/s) TAV were identified in all animals, with corresponding peak pressure 50-81 mmHg, and 46-64 mmHg, respectively. Blood flow velocity was, on average, highest at the middle position (TAV 33 cm/s), but with significant variability between animals (SD 2.8) and positions within the same animal (SD 9.3). Conclusion: RescueDoppler detected TAV changes during CPR with alternating chest compression positions, identifying the position yielding maximal TAV. Future clinical studies should investigate if RescueDoppler can be used as a real-time hemodynamical feedback device to guide compression position.

8.
Intensive Care Med Exp ; 12(1): 54, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38856861

RESUMEN

BACKGROUND: Continuous monitoring of mitral annular plane systolic excursion (MAPSE) using transesophageal echocardiography (TEE) may improve the evaluation of left ventricular (LV) function in postoperative intensive care patients. We aimed to assess the utility of continuous monitoring of LV function using TEE and artificial intelligence (autoMAPSE) in postoperative intensive care patients. METHODS: In this prospective observational study, we monitored 50 postoperative intensive care patients for 120 min immediately after cardiac surgery. We recorded a set of two-chamber and four-chamber TEE images every five minutes. We defined monitoring feasibility as how often the same wall from the same patient could be reassessed, and categorized monitoring feasibility as excellent if the same LV wall could be reassessed in ≥ 90% of the total recordings. To compare autoMAPSE with manual measurements, we rapidly recorded three sets of repeated images to assess precision (least significant change), bias, and limits of agreement (LOA). To assess the ability to identify changes (trending ability), we compared changes in autoMAPSE with the changes in manual measurements in images obtained during the initiation of cardiopulmonary bypass as well as before and after surgery. RESULTS: Monitoring feasibility was excellent in most patients (88%). Compared with manual measurements, autoMAPSE was more precise (least significant change 2.2 vs 3.1 mm, P < 0.001), had low bias (0.4 mm), and acceptable agreement (LOA - 2.7 to 3.5 mm). AutoMAPSE had excellent trending ability, as its measurements changed in the same direction as manual measurements (concordance rate 96%). CONCLUSION: Continuous monitoring of LV function was feasible using autoMAPSE. Compared with manual measurements, autoMAPSE had excellent trending ability, low bias, acceptable agreement, and was more precise.

9.
Ultrasound Med Biol ; 50(6): 797-804, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38485534

RESUMEN

OBJECTIVE: Evaluation of left ventricular (LV) function in critical care patients is useful for guidance of therapy and early detection of LV dysfunction, but the tools currently available are too time-consuming. To resolve this issue, we previously proposed a method for the continuous and automatic quantification of global LV function in critical care patients based on the detection and tracking of anatomical landmarks on transesophageal heart ultrasound. In the present study, our aim was to improve the performance of mitral annulus detection in transesophageal echocardiography (TEE). METHODS: We investigated several state-of-the-art networks for both the detection and tracking of the mitral annulus in TEE. We integrated the networks into a pipeline for automatic assessment of LV function through estimation of the mitral annular plane systolic excursion (MAPSE), called autoMAPSE. TEE recordings from a total of 245 patients were collected from St. Olav's University Hospital and used to train and test the respective networks. We evaluated the agreement between autoMAPSE estimates and manual references annotated by expert echocardiographers in 30 Echolab patients and 50 critical care patients. Furthermore, we proposed a prototype of autoMAPSE for clinical integration and tested it in critical care patients in the intensive care unit. RESULTS: Compared with manual references, we achieved a mean difference of 0.8 (95% limits of agreement: -2.9 to 4.7) mm in Echolab patients, with a feasibility of 85.7%. In critical care patients, we reached a mean difference of 0.6 (95% limits of agreement: -2.3 to 3.5) mm and a feasibility of 88.1%. The clinical prototype of autoMAPSE achieved real-time performance. CONCLUSION: Automatic quantification of LV function had high feasibility in clinical settings. The agreement with manual references was comparable to inter-observer variability of clinical experts.


Asunto(s)
Puntos Anatómicos de Referencia , Ecocardiografía Transesofágica , Función Ventricular Izquierda , Humanos , Ecocardiografía Transesofágica/métodos , Función Ventricular Izquierda/fisiología , Puntos Anatómicos de Referencia/diagnóstico por imagen , Femenino , Masculino , Anciano , Persona de Mediana Edad , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos
10.
Echocardiography ; 30(6): 682-92, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23347171

RESUMEN

We aimed to compare three-dimensional (3D) and two-dimensional (2D) echocardiography in the evaluation of patients with recent myocardial infarction (MI), using late-enhancement magnetic resonance imaging (LE-MRI) as a reference method. Echocardiography and LE-MRI were performed approximately 1 month after first-time MI in 58 patients. Echocardiography was also performed on 35 healthy controls. Left ventricular (LV) ejection fraction by 3D echocardiography (3D-LVEF), 3D wall-motion score (WMS), 2D-WMS, 3D speckle tracking-based longitudinal, circumferential, transmural and area strain, and 2D speckle tracking-based longitudinal strain (LS) were measured. The global correlations to infarct size by LE-MRI were significantly higher (P < 0.03) for 3D-WMS and 2D-WMS compared with 3D-LVEF and the 4 different measurements of 3D strain, and 2D global longitudinal strain (GLS) was more closely correlated to LE-MRI than 3D GLS (P < 0.03). The segmental correlations to infarct size by LE-MRI were also significantly higher (P < 0.04) for 3D-WMS, 2D-WMS, and 2D LS compared with the other indices. Three-dimensional WMS showed a sensitivity of 76% and a specificity of 72% for identification of LV infarct size >12%, and a sensitivity of 73% and a specificity of 95% for identification of segments with transmural infarct extension. Three-dimensional WMS and 2D gray-scale echocardiography showed the strongest correlations to LE-MRI. The tested 3D strain method suffers from low temporal and spatial resolution in 3D acquisitions and added diagnostic value could not be proven.


Asunto(s)
Ecocardiografía Tridimensional/estadística & datos numéricos , Diagnóstico por Imagen de Elasticidad/estadística & datos numéricos , Imagen por Resonancia Cinemagnética/estadística & datos numéricos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/epidemiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/epidemiología , Causalidad , Comorbilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Noruega/epidemiología , Prevalencia , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad
11.
Int J Cardiovasc Imaging ; 39(4): 757-766, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36715881

RESUMEN

PURPOSE: Identification of regional dysfunction is important for early risk stratification in patients with suspected non-ST-elevation myocardial infarction (NSTEMI). Strain echocardiography enables quantification of segmental myocardial deformation. However, the clinical use is hampered by time-consuming manual measurements. We aimed to evaluate whether an in-house developed software for automated analysis of segmental myocardial deformation based on tissue Doppler imaging (TDI) could predict coronary occlusion in patients with suspected NSTEMI. METHODS: Eighty-four patients with suspected NSTEMI were included in the analysis. Echocardiography was performed at admission. Strain, strain rate and post-systolic shortening index (PSI) were analyzed by the automated TDI-based tool and the ability to predict coronary occlusion was assessed. For comparison, strain measurements were performed both by manual TDI-based analyses and by semi-automatic speckle tracking echocardiography (STE). All patients underwent coronary angiography. RESULTS: Seventeen patients had an acute coronary occlusion. Global strain and PSI by STE were able to differentiate occluded from non-occluded culprit lesions (respectively - 15.0% vs. -17.1%, and 8.1% vs. 5.1%, both p-values < 0.05) and identify patients with an acute coronary occlusion (AUC 0.66 for both strain and PSI). Measurements of strain, strain rate and PSI based on TDI were not significantly different between occluded and non-occluded territories. CONCLUSION: Automated measurements of myocardial deformation based on TDI were not able to identify acute coronary occlusion in patients with suspected NSTEMI. However, this study confirms the potential of strain by STE for early risk stratification in patients with chest pain.


Asunto(s)
Oclusión Coronaria , Infarto del Miocardio sin Elevación del ST , Humanos , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/terapia , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Vasos Coronarios , Valor Predictivo de las Pruebas , Corazón
12.
BJA Open ; 6: 100144, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37588175

RESUMEN

Background: General anaesthesia is associated with neurocognitive deficits in infants after noncardiac surgery. Disturbances in cerebral perfusion as a result of systemic hypotension and impaired autoregulation may be a potential cause. Our aim was to study cerebral blood flow (CBF) velocity continuously during general anaesthesia in infants undergoing noncardiac surgery and compare variations in CBF velocity with simultaneously measured near-infrared spectroscopy (NIRS), blood pressure, and heart rate. Methods: NeoDoppler, a recently developed ultrasound system, was used to monitor CBF velocity via the anterior fontanelle during induction and maintenance of general anaesthesia until the start of surgery, and during recovery. NIRS, blood pressure, and heart rate were monitored simultaneously and synchronised with the NeoDoppler measurements. Results: Thirty infants, with a median postmenstrual age at surgery of 37.6 weeks (range 28.6-60.0) were included. Compared with baseline, the trend curves showed a decrease in CBF velocity during induction and maintenance of anaesthesia and returned to baseline values during recovery. End-diastolic velocity decreased in all infants during anaesthesia, on average by 59%, whereas peak systolic- and time-averaged velocities decreased by 26% and 45%, respectively. In comparison, the reduction in mean arterial pressure was only 20%. NIRS values were high and remained stable. When adjusting for mean arterial pressure, the significant decrease in end-diastolic velocity persisted, whereas there was only a small reduction in peak systolic velocity. Conclusions: Continuous monitoring of CBF velocity using NeoDoppler during anaesthesia is feasible and may provide valuable information about cerebral perfusion contributing to a more targeted haemodynamic management in anaesthetised infants.

13.
Artif Intell Med ; 144: 102646, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37783546

RESUMEN

Perioperative monitoring of cardiac function is beneficial for early detection of cardiovascular complications. The standard of care for cardiac monitoring performed by trained cardiologists and anesthesiologists involves a manual and qualitative evaluation of ultrasound imaging, which is a time-demanding and resource-intensive process with intraobserver- and interobserver variability. In practice, such measures can only be performed a limited number of times during the intervention. To overcome these difficulties, this study presents a robust method for automatic and quantitative monitoring of cardiac function based on 3D transesophageal echocardiography (TEE) B-mode ultrasound recordings of the left ventricle (LV). Such an assessment obtains consistent measurements and can produce a near real-time evaluation of ultrasound imagery. Hence, the presented method is time-saving and results in increased accessibility. The mitral annular plane systolic excursion (MAPSE), characterizing global LV function, is estimated by landmark detection and cardiac view classification of two-dimensional images extracted along the long-axis of the ultrasound volume. MAPSE estimation directly from 3D TEE recordings is beneficial since it removes the need for manual acquisition of cardiac views, hence decreasing the need for interference by physicians. Two convolutional neural networks (CNNs) were trained and tested on acquired ultrasound data of 107 patients, and MAPSE estimates were compared to clinically obtained references in a blinded study including 31 patients. The proposed method for automatic MAPSE estimation had low bias and low variability in comparison to clinical reference measures. The method accomplished a mean difference for MAPSE estimates of (-0.16±1.06) mm. Thus, the results did not show significant systematic errors. The obtained bias and variance of the method were comparable to inter-observer variability of clinically obtained MAPSE measures on 2D TTE echocardiography. The novel pipeline proposed in this study has the potential to enhance cardiac monitoring in perioperative- and intensive care settings.


Asunto(s)
Inteligencia Artificial , Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Ultrasonografía , Ecocardiografía/métodos , Función Ventricular Izquierda
14.
Resusc Plus ; 15: 100412, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37448689

RESUMEN

Background/Purpose: Pulse palpation is an unreliable method for diagnosing cardiac arrest. To address this limitation, continuous hemodynamic monitoring may be a viable solution. Therefore, we developed a novel, hands-free Doppler system, RescueDoppler, to detect the pulse continuously in the carotid artery. Methods: In twelve pigs, we evaluated RescueDopplers potential to measure blood flow velocity in three situations where pulse palpation of the carotid artery was insufficient: (1) systolic blood pressure below 60 mmHg, (2) ventricular fibrillation (VF) and (3) pulseless electrical activity (PEA). (1) Low blood pressure was induced using a Fogarty balloon catheter to occlude the inferior vena cava. (2) An implantable cardioverter-defibrillator induced VF. (3) Myocardial infarction after microembolization of the left coronary artery caused True-PEA. Invasive blood pressure was measured in the contralateral carotid artery. Time-averaged blood flow velocity (TAV) in the carotid artery was related to mean arterial pressure (MAP) in a linear mixed model. Results: RescueDoppler identified pulsatile blood flow in 41/41 events with systolic blood pressure below 60 mmHg, with lowest blood pressure of 19 mmHg. In addition the absence of spontaneous circulation was identified in 21/21 VF events and true PEA in 2/2 events. The intraclass correlation coefficient within animals for TAV and MAP was 0.94 (95% CI. 0.85-0.98). Conclusions: In a porcine model, RescueDoppler reliably identified pulsative blood flow with blood pressures below 60 mmHg. During VF and PEA, circulatory arrest was rapidly and accurately demonstrated. RescueDoppler could potentially replace unreliable pulse palpation during cardiac arrest and cardiopulmonary resuscitation.

15.
PLoS One ; 17(4): e0266147, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35381046

RESUMEN

PURPOSE: Cancer is among the leading causes of death in the developed world, and lung cancer is the most lethal type. Early detection is crucial for better prognosis, but can be resource intensive to achieve. Automating tasks such as lung tumor localization and segmentation in radiological images can free valuable time for radiologists and other clinical personnel. Convolutional neural networks may be suited for such tasks, but require substantial amounts of labeled data to train. Obtaining labeled data is a challenge, especially in the medical domain. METHODS: This paper investigates the use of a teacher-student design to utilize datasets with different types of supervision to train an automatic model performing pulmonary tumor segmentation on computed tomography images. The framework consists of two models: the student that performs end-to-end automatic tumor segmentation and the teacher that supplies the student additional pseudo-annotated data during training. RESULTS: Using only a small proportion of semantically labeled data and a large number of bounding box annotated data, we achieved competitive performance using a teacher-student design. Models trained on larger amounts of semantic annotations did not perform better than those trained on teacher-annotated data. Our model trained on a small number of semantically labeled data achieved a mean dice similarity coefficient of 71.0 on the MSD Lung dataset. CONCLUSIONS: Our results demonstrate the potential of utilizing teacher-student designs to reduce the annotation load, as less supervised annotation schemes may be performed, without any real degradation in segmentation accuracy.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Neoplasias Pulmonares , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Redes Neurales de la Computación , Estudiantes , Tomografía Computarizada por Rayos X
16.
Polymers (Basel) ; 13(11)2021 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-34073296

RESUMEN

An industrially manufactured recycled polyol, obtained by acidolysis process, was for the first time proved to be a possible replacement of the reference fossil-based polyol in a low-density formulation suitable for industrial production of flexible polyurethane foams. The influence of increasing recycled polyol amounts on the properties of the polyurethane foam has been studied, also performing foam emission tests to evaluate the environmental impact. Using 10 pbw recycled polyol in the standard formulation, significant differences of the physical properties were not observed, but increase of the recycled polyol amount to 30 pbw led to a dramatic decrease of the foam air flow and a very tight foam. To overcome this drawback, N,N'-bis[3-(dimethylamino)propyl]urea was selected as tertiary amine catalyst, enabling the preservation of foam properties even at high recycled polyol level (30 pbw). Foam emission data demonstrated that this optimized foam formulation also led to an important reduction of volatile organic compounds. The results open the way for further optimization studies in low-density flexible polyurethane foam formulations, to increase the reutilization of the polyurethane waste and reduce the amount of petroleum-based raw materials.

17.
Polymers (Basel) ; 12(7)2020 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-32664336

RESUMEN

Ester polyurethane (PU) foam waste was reacted at atmospheric pressure in an autoclave and using microwaves with diethylene glycol (DEG) at different PU/DEG ratios in the presence of diethanolamine as a catalyst to find the glycolysis conditions that allow for the improved recovery of the PU foam waste and enable the recycling of the whole glycolysis product in foam formulations suitable for industrial application. The recycled polyol was characterized by dynamic viscosity, hydroxyl number, water content, and density, while thermal stability was assessed using thermogravimetric analysis. In the PU foam formulation, 1% and 5% of the glycolyzed material was reused. The relationship between the reuse level of the recycled polyol and the physical properties of the foam was thoroughly investigated. It was observed that both hardness and air flow decreased with increasing recycled polyol content, particularly for the polyester type foam, while tensile strength and compression strength increased. Depending on the amount of recycled polyol and catalyst used, polyether-based foams could be obtained with a low air permeability, needed in special applications as sealed foams, or with higher air permeability desirable for comfort PU foams. The results open the way for further optimization studies of industrial polyurethane foam formulations using a glycolysis process without any separation stage.

18.
Int J Comput Assist Radiol Surg ; 14(6): 977-986, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30891655

RESUMEN

PURPOSE: Accurate lung cancer diagnosis is crucial to select the best course of action for treating the patient. From a simple chest CT volume, it is necessary to identify whether the cancer has spread to nearby lymph nodes or not. It is equally important to know precisely where each malignant lymph node is with respect to the surrounding anatomical structures and the airways. In this paper, we introduce a new data-set containing annotations of fifteen different anatomical structures in the mediastinal area, including lymph nodes of varying sizes. We present a 2D pipeline for semantic segmentation and instance detection of anatomical structures and potentially malignant lymph nodes in the mediastinal area. METHODS: We propose a 2D pipeline combining the strengths of U-Net for pixel-wise segmentation using a loss function dealing with data imbalance and Mask R-CNN providing instance detection and improved pixel-wise segmentation within bounding boxes. A final stage performs pixel-wise labels refinement and 3D instance detection using a tracking approach along the slicing dimension. Detected instances are represented by a 3D pixel-wise mask, bounding volume, and centroid position. RESULTS: We validated our approach following a fivefold cross-validation over our new data-set of fifteen lung cancer patients. For the semantic segmentation task, we reach an average Dice score of 76% over all fifteen anatomical structures. For the lymph node instance detection task, we reach 75% recall for 9 false positives per patient, with an average centroid position estimation error of 3 mm in each dimension. CONCLUSION: Fusing 2D networks' results increases pixel-wise segmentation results while enabling good instance detection. Better leveraging of the 3D information and station mapping for the detected lymph nodes are the next steps.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/patología , Ganglios Linfáticos/diagnóstico por imagen , Mediastino/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Humanos , Neoplasias Pulmonares/patología , Ganglios Linfáticos/patología , Mediastino/patología , Estadificación de Neoplasias
19.
Eur J Orthod ; 30(6): 545-51, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19054811

RESUMEN

The purpose of this study was to determine the degree of condylar asymmetry in children with juvenile idiopathic arthritis (JIA) using cone-beam computed tomography (CBCT) and analysis software. For 20 patients (14 girls and six boys; mean age 11.21 +/- 3.54 years), resultant cross-sectional images of the left and right temporomandibular joints (TMJs) were semi-automatically segmented, and exact registration of the right, with respect to the flipped left grey-level condyle, was obtained. Visual inspection of the volume images in 360 degree rotation showed a wide variety of condylar destruction patterns, ranging from small erosions within the cortex to almost complete deformation of the condylar head. Because segmentation was restricted to the delineation of the cortical region, possible changes in the deeper zones were not reproduced. Descriptive statistics [median and interquartile range (IQR)] and diagrams (frequency distribution) were used to assess the results. Initial analysis of condylar volume (including both flipped left and right) showed a median value for volume of 0.844 cm(3) (IQR 0.323), while the median value for volume difference between both condyles was 0.051 cm(3) (IQR 0.098). Analysis of the degree of asymmetry showed a median value of 26.18 per cent (IQR 14.46). Using the CBCT-based method, it was shown that condylar asymmetry was a common feature in children with JIA. The degree of asymmetry was variable, but significant in the majority of the subjects.


Asunto(s)
Artritis Juvenil/patología , Asimetría Facial/patología , Interpretación de Imagen Asistida por Computador/métodos , Cóndilo Mandibular/patología , Adolescente , Anatomía Transversal , Artritis Juvenil/complicaciones , Niño , Tomografía Computarizada de Haz Cónico , Asimetría Facial/complicaciones , Femenino , Lateralidad Funcional , Humanos , Masculino , Tamaño de los Órganos
20.
Acad Radiol ; 13(9): 1062-71, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16935718

RESUMEN

RATIONALE AND OBJECTIVES: This report proposes an alternative method for the automatic detection of colonic polyps that is robust enough to be directly applicable on low-dose computed tomographic data. MATERIALS AND METHODS: The polyp modeling process takes into account both the gray-level appearance of polyps (intensity profiles) and their geometry (extended Gaussian images). Spherical harmonic decompositions are used for comparison purposes, allowing fast estimation of the similarity between a candidate and a set of previously computed models. Starting from the original raw data (acquired at 55 mA), five patient data sets (prone and supine scans) are reconstructed at different dose levels (to 5 mA) by using different kernel filters, slice overlaps, and increments. Additionally, the efficacy of applying an edge-preserving smoothing filter before detection is assessed. RESULTS: Although image quality decreases when decreasing acquisition milliamperes, all polyps greater than 6 mm are detected successfully, even at 15 mA. Although not important at high doses, smoothing improves detection results for ultra-low-dose (tube current<15 mA) data. CONCLUSION: The advantage of low-dose scans is a significant decrease in effective dose from 4.93 to 1.61 mSv while retaining high detection values, particularly important when thinking of population screening.


Asunto(s)
Algoritmos , Inteligencia Artificial , Pólipos del Colon/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Almacenamiento y Recuperación de la Información/métodos , Dosis de Radiación , Protección Radiológica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA