Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
PLoS Med ; 19(4): e1003965, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35452458

RESUMEN

BACKGROUND: Catheter radiofrequency (RF) ablation for cardiac arrhythmias is a painful procedure. Prior work using functional near-infrared spectroscopy (fNIRS) in patients under general anesthesia has indicated that ablation results in activity in pain-related cortical regions, presumably due to inadequate blockade of afferent nociceptors originating within the cardiac system. Having an objective brain-based measure for nociception and analgesia may in the future allow for enhanced analgesic control during surgical procedures. Hence, the primary aim of this study is to demonstrate that the administration of remifentanil, an opioid widely used during surgery, can attenuate the fNIRS cortical responses to cardiac ablation. METHODS AND FINDINGS: We investigated the effects of continuous remifentanil on cortical hemodynamics during cardiac ablation under anesthesia. In a randomized, double-blinded, placebo (PL)-controlled trial, we examined 32 pediatric patients (mean age of 15.8 years,16 females) undergoing catheter ablation for cardiac arrhythmias at the Cardiology Department of Boston Children's Hospital from October 2016 to March 2020; 9 received 0.9% NaCl, 12 received low-dose (LD) remifentanil (0.25 mcg/kg/min), and 11 received high-dose (HD) remifentanil (0.5 mcg/kg/min). The hemodynamic changes of primary somatosensory and prefrontal cortices were recorded during surgery using a continuous wave fNIRS system. The primary outcome measures were the changes in oxyhemoglobin concentration (NadirHbO, i.e., lowest oxyhemoglobin concentration and PeakHbO, i.e., peak change and area under the curve) of medial frontopolar cortex (mFPC), lateral prefrontal cortex (lPFC) and primary somatosensory cortex (S1) to ablation in PL versus remifentanil groups. Secondary measures included the fNIRS response to an auditory control condition. The data analysis was performed on an intention-to-treat (ITT) basis. Remifentanil group (dosage subgroups combined) was compared with PL, and a post hoc analysis was performed to identify dose effects. There were no adverse events. The groups were comparable in age, sex, and number of ablations. Results comparing remifentanil versus PL show that PL group exhibit greater NadirHbO in inferior mFPC (mean difference (MD) = 1.229, 95% confidence interval [CI] = 0.334, 2.124, p < 0.001) and superior mFPC (MD = 1.206, 95% CI = 0.303, 2.109, p = 0.001) and greater PeakHbO in inferior mFPC (MD = -1.138, 95% CI = -2.062, -0.214, p = 0.002) and superior mFPC (MD = -0.999, 95% CI = -1.961, -0.036, p = 0.008) in response to ablation. S1 activation from ablation was greatest in PL, then LD, and HD groups, but failed to reach significance, whereas lPFC activation to ablation was similar in all groups. Ablation versus auditory stimuli resulted in higher PeakHbO in inferior mFPC (MD = 0.053, 95% CI = 0.004, 0.101, p = 0.004) and superior mFPC (MD = 0.052, 95% CI = 0.013, 0.091, p < 0.001) and higher NadirHbO in posterior superior S1 (Pos. SS1; MD = -0.342, 95% CI = -0.680, -0.004, p = 0.007) during ablation of all patients. Remifentanil group had smaller NadirHbO in inferior mFPC (MD = 0.098, 95% CI = 0.009, 0.130, p = 0.003) and superior mFPC (MD = 0.096, 95% CI = 0.008, 0.116, p = 0.003) and smaller PeakHbO in superior mFPC (MD = -0.092, 95% CI = -0.680, -0.004, p = 0.007) during both the stimuli. Study limitations were small sample size, motion from surgery, indirect measure of nociception, and shallow penetration depth of fNIRS only allowing access to superficial cortical layers. CONCLUSIONS: We observed cortical activity related to nociception during cardiac ablation under general anesthesia with remifentanil. It highlights the potential of fNIRS to provide an objective pain measure in unconscious patients, where cortical-based measures may be more accurate than current evaluation methods. Future research may expand on this application to produce a real-time indication of pain that will aid clinicians in providing immediate and adequate pain treatment. TRIAL REGISTRATION: ClinicalTrials.gov NCT02703090.


Asunto(s)
Nocicepción , Oxihemoglobinas , Adolescente , Analgésicos Opioides/efectos adversos , Anestesia General/efectos adversos , Anestesia General/métodos , Arritmias Cardíacas/inducido químicamente , Encéfalo , Niño , Femenino , Humanos , Masculino , Nocicepción/fisiología , Dolor , Remifentanilo
2.
J Cardiothorac Vasc Anesth ; 36(9): 3617-3625, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35691856

RESUMEN

OBJECTIVE: To better understand the patterns of use and the perceived utility of tissue oximetry in pediatric cardiac surgery. DESIGN: A voluntary 32-question Research Electronic Data Capture survey instrument was sent twice via e-mail to the entire Congenital Cardiac Anesthesia Society (CCAS) membership (January 13, 2021 and March 9,2021). SETTING: International multi-institutional, universities, academic centers, and community hospitals. PARTICIPANTS: CCAS members. INTERVENTIONS: Not applicable. MEASUREMENTS AND MAIN RESULTS: The survey was completed by 185 of 1,131 members (16.4% response rate). The majority of respondents (93.5%) reported use of tissue oximetry, with 97.1% reporting use for cardiac surgery with cardiopulmonary bypass, 76.3% for cardiac surgery without cardiopulmonary bypass, 34.7% in the cardiac catheterization laboratory, and 39.3% for major noncardiac surgeries. Only 14.5% reported that their institution had a formal near-infrared spectroscopy/tissue oximetry-based protocol. The most common sensor placement configuration was bilateral cerebral. More than 90% of respondents reported having made a clinical management change based on tissue oximetry values, although there was variability as to when respondents would intervene. The majority of respondents agreed or strongly agreed that tissue oximetry adds diagnostic value to standard intraoperative monitors, validates clinical observations, and aids in guiding patient management. Most, however, felt that tissue oximetry alone is not enough to inform management changes. CONCLUSIONS: Near-infrared spectroscopy-based tissue oximetry frequently used was by CCAS members, but with significant variations in clinical application.


Asunto(s)
Anestesia en Procedimientos Quirúrgicos Cardíacos , Procedimientos Quirúrgicos Cardíacos , Cirugía Torácica , Procedimientos Quirúrgicos Cardíacos/métodos , Niño , Humanos , Oximetría/métodos , Oxígeno , Encuestas y Cuestionarios
3.
Anesth Analg ; 133(2): 379-392, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33764341

RESUMEN

Transcranial Doppler (TCD) ultrasonography is the only noninvasive bedside technology for the detection and monitoring of cerebral embolism. TCD may identify patients at risk of acute and chronic neurologic injury from gaseous or solid emboli. Importantly, a window of opportunity for intervention-to eliminate the source of the emboli and thereby prevent subsequent development of a clinical or subclinical stroke-may be identified using TCD. In this review, we discuss the application of TCD sonography in the perioperative and intensive care setting in adults and children known to be at increased risk of cerebral embolism. The major challenge for evaluation of emboli, especially in children, is the need to establish the ground truth and define true emboli identified by TCD. This requires the development and validation of a predictive TCD emboli monitoring technique so that appropriately designed clinical studies intended to identify specific modifiable factors and develop potential strategies to reduce pathologic cerebral embolic burden can be performed.


Asunto(s)
Cuidados Críticos , Embolia Intracraneal/diagnóstico por imagen , Atención Perioperativa , Ultrasonografía Doppler Transcraneal , Factores de Edad , Humanos , Unidades de Cuidados Intensivos , Embolia Intracraneal/etiología , Embolia Intracraneal/terapia , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Factores de Riesgo
4.
Anesth Analg ; 131(3): e138-e141, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31985496

RESUMEN

Regional cerebral oxygenation index (rSO2) based on near-infrared spectroscopy (NIRS) is frequently used to detect low venous oxyhemoglobin saturation (ScvO2). We compared the performance of 2 generations of NIRS devices. Clinically obtained, time-matched cerebral rSO2 and ScvO2 values were compared in infants monitored with the FORE-SIGHT (n = 73) or FORE-SIGHT ELITE (n = 47) by linear regression and Bland-Altman analyses. In both devices, cerebral rSO2 correlated poorly with measured ScvO2 (FORE-SIGHT partial correlation 0.50 [95% confidence interval {CI}, 0.40-0.58]; FORE-SIGHT ELITE partial correlation 0.47 [0.39-0.55]) and mean bias was +8 (standard deviation [SD] 13.2) for FORE-SIGHT and +14 (SD 12.5) for FORE-SIGHT ELITE. When ScvO2 was <30%, rSO2 was <40 in 8% of FORE-SIGHT ELITE readings. Future NIRS should be validated in more hypoxic cohorts.


Asunto(s)
Encéfalo/irrigación sanguínea , Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas/cirugía , Hipoxia Encefálica/diagnóstico , Oximetría/instrumentación , Oxihemoglobinas/metabolismo , Espectroscopía Infrarroja Corta/instrumentación , Biomarcadores/sangre , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Diseño de Equipo , Humanos , Hipoxia Encefálica/sangre , Hipoxia Encefálica/etiología , Recién Nacido , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
5.
J Cardiothorac Vasc Anesth ; 34(2): 489-500, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31582201

RESUMEN

Near-infrared spectroscopy (NIRS) is widely used to monitor tissue oxygenation in the pediatric cardiac surgical population. Clinicians who use NIRS must understand the underlying measurement principles in order to interpret and use this monitoring modality appropriately. The aims of this narrative review are to provide a brief overview of NIRS technology, discuss the normative and critical values of cerebral and somatic tissue oxygen saturation and the interpretation of these values, present the clinical studies (and their limitations) of NIRS as a perioperative monitoring modality in the pediatric congenital heart disease population, and introduce the emerging and future applications of NIRS.


Asunto(s)
Cardiopatías Congénitas , Espectroscopía Infrarroja Corta , Niño , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Humanos , Monitoreo Fisiológico , Oximetría , Oxígeno
6.
Anesth Analg ; 128(4): 661-668, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-29324491

RESUMEN

BACKGROUND: Cerebral oximetry using near-infrared spectroscopy is a noninvasive optical technology to detect cerebral hypoxia-ischemia and develop interventions to prevent and ameliorate hypoxic brain injury. Cerebral oximeters are calibrated and validated by comparison of the near-infrared spectroscopy-measured cerebral O2 saturation (SctO2) to a "field" or reference O2 saturation (REF CX) calculated as a weighted average from arterial and jugular bulb oxygen saturations. In this study, we calibrated and validated the second-generation, 5 wavelength, FORE-SIGHT Elite with the medium sensor (source-detector separation 12 and 40 mm) for measurement of SctO2 in children with congenital heart disease. METHODS: After institutional review board approval and written informed consent, 63 children older than 1 month and ≥2.5 kg scheduled for cardiac catheterization were enrolled. Self-adhesive FORE-SIGHT Elite medium sensors were placed on the right and left sides of the forehead. Blood samples for calculation of REF CX were drawn simultaneously from the aorta or femoral artery and the jugular bulb before (T1) and shortly after (T2) baseline hemodynamic measurements. FORE-SIGHT Elite SctO2 measurements were compared to the REF CX (REF CX = [0.3 SaO2] + [0.7 SjbO2]) using Deming regression, least squares linear regression, and Bland-Altman analysis. RESULTS: Sixty-one subjects (4.5 [standard deviation 4.4] years of age; 17 [standard deviation 13] kg, male 56%) completed the study protocol. Arterial oxygen saturation ranged from 64.7% to 99.1% (median 96.0%), jugular bulb venous oxygen saturation from 34.1% to 88.1% (median 68.2%), the REF CX from 43.8% to 91.4% (median 76.9%), and the SctO2 from 47.8% to 90.8% (median 76.3%). There was a high degree of correlation in SctO2 between the right and left sensors at a given time point (within subject between sensor correlation r = 0.91 and 95% confidence interval [CI], 0.85-0.94) or between T1 and T2 for the right and left sensors (replicates, within subject between time point correlation r = 0.95 and 95% CI, 0.92-0.96). By Deming regression, the estimated slope was 0.966 (95% CI, 0.786-1.147; P = .706 for testing against null hypothesis of slope = 1) with a y intercept of 2.776 (95% CI, -11.102 to 16.654; P = .689). The concordance correlation coefficient was 0.873 (95% CI, 0.798-0.922). Bland-Altman analysis for agreement between SctO2 and REF CX that accounted for repeated measures (both in times and sensors) found a bias of -0.30% (95% limits of agreement: -10.56% to 9.95%). CONCLUSIONS: This study calibrated and validated the FORE-SIGHT Elite tissue oximeter to accurately measure SctO2 in pediatric patients with the medium sensor.


Asunto(s)
Cardiopatías Congénitas/diagnóstico , Oximetría/instrumentación , Espectroscopía Infrarroja Corta/métodos , Adolescente , Encéfalo/irrigación sanguínea , Lesiones Encefálicas/patología , Calibración , Cateterismo Cardíaco , Circulación Cerebrovascular , Niño , Preescolar , Diseño de Equipo , Femenino , Humanos , Hipoxia/diagnóstico , Hipoxia-Isquemia Encefálica , Lactante , Masculino , Oximetría/métodos , Oxígeno/metabolismo , Análisis de Regresión , Reproducibilidad de los Resultados
7.
J Pediatr ; 181: 42-48.e2, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27837950

RESUMEN

OBJECTIVE: To determine whether brain volume is reduced at 1 year of age and whether these volumes are associated with neurodevelopment in biventricular congenital heart disease (CHD) repaired in infancy. STUDY DESIGN: Infants with biventricular CHD (n = 48) underwent brain magnetic resonance imaging (MRI) and neurodevelopmental testing with the Bayley Scales of Infant Development-II and the MacArthur-Bates Communicative Development Inventories at 1 year of age. A multitemplate based probabilistic segmentation algorithm was applied to volumetric MRI data. We compared volumes with those of 13 healthy control infants of comparable ages. In the group with CHD, we measured Spearman correlations between neurodevelopmental outcomes and the residuals from linear regression of the volumes on corrected chronological age at MRI and sex. RESULTS: Compared with controls, infants with CHD had reductions of 54 mL in total brain (P = .009), 40 mL in cerebral white matter (P <.001), and 1.2 mL in brainstem (P = .003) volumes. Within the group with CHD, brain volumes were not correlated with Bayley Scales of Infant Development-II scores but did correlate positively with MacArthur-Bates Communicative Development Inventory language development. CONCLUSIONS: Infants with biventricular CHD show total brain volume reductions at 1 year of age, driven by differences in cerebral white matter. White matter volume correlates with language development, but not broader developmental indices. These findings suggest that abnormalities in white matter development detected months after corrective heart surgery may contribute to language impairment. TRIAL REGISTRATION: ClinicalTrials.gov: NCT00006183.


Asunto(s)
Cardiopatías Congénitas/cirugía , Desarrollo del Lenguaje , Imagen por Resonancia Magnética/métodos , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/crecimiento & desarrollo , Desarrollo Infantil/fisiología , Preescolar , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/mortalidad , Humanos , Lactante , Recién Nacido , Modelos Lineales , Masculino , Pruebas Neuropsicológicas , Tamaño de los Órganos , Valor Predictivo de las Pruebas , Pronóstico , Valores de Referencia , Tasa de Supervivencia , Cirugía Torácica/métodos
8.
Anesth Analg ; 125(1): 234-240, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28514318

RESUMEN

BACKGROUND: Increased hemoglobin (Hb) concentration accompanying hypoxemia is a compensatory response to maintain tissue oxygen delivery. Near infrared spectroscopy (NIRS) is used clinically to detect abnormalities in the balance of cerebral tissue oxygen delivery and consumption, including in children with congenital heart disease (CHD). Although NIRS-measured cerebral tissue O2 saturation (ScO2) correlates with arterial oxygen saturation (SaO2), jugular bulb O2 saturation (SjbO2), and Hb, little data exist on the interplay between these factors and cerebral O2 extraction (COE). This study investigated the associations of ScO2 and ΔSaO2-ScO2 with SaO2 and Hb and verified the normal range of ScO2 in children with CHD. METHODS: Children undergoing cardiac catheterization for CHD were enrolled in a calibration and validation study of the FORE-SIGHT NIRS monitor. Two pairs of simultaneous arterial and jugular bulb samples were drawn for co-oximetry, calculation of a reference ScO2 (REF CX), and estimation of COE. Pearson correlation and linear regression were used to determine relationships between O2 saturation parameters and Hb. Data were also analyzed according to diagnostic group defined as acyanotic (SaO2 ≥ 90%) and cyanotic (SaO2 < 90%). RESULTS: Of 65 children studied, acceptable jugular bulb samples (SjbO2 absolute difference between samples ≤10%) were obtained in 57 (88%). The ΔSaO2-SjbO2, ΔSaO2-ScO2, and ΔSaO2-REF CX were positively correlated with SaO2 and negatively correlated with Hb (all P < .001). Although by diagnostic group ScO2 differed statistically (P = .002), values in the cyanotic patients were within the range considered normal (69% ± 6%). COE estimated by the difference between arterial and jugular bulb O2 content (ΔCaO2-CjbO2, mL O2/100 mL) was not different for cyanotic and acyanotic patients (P = .10), but estimates using ΔSaO2-SjbO2, ΔSaO2-ScO2, or ΔSaO2-ScO2/SaO2 were significantly different between the cyanotic and acyanotic children (P < .001). CONCLUSIONS: Children with adequately compensated chronic hypoxemia appear to have ScO2 values within the normal range. The ΔSaO2-ScO2 is inversely related to Hb, with the implication that in the presence of reduced Hb, particularly if coupled with a decreased cardiac output, the ScO2 can fall to values associated with brain injury in laboratory studies.


Asunto(s)
Encéfalo/patología , Circulación Cerebrovascular , Cardiopatías Congénitas/diagnóstico , Hipoxia/diagnóstico , Adolescente , Lesiones Encefálicas , Calibración , Cateterismo Cardíaco , Niño , Preescolar , Femenino , Hemoglobinas/análisis , Humanos , Lactante , Modelos Lineales , Masculino , Monitoreo Fisiológico , Oximetría , Oxígeno/análisis , Estudios Prospectivos , Espectroscopía Infrarroja Corta
9.
J Pediatr ; 177: 184-190.e3, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27499214

RESUMEN

OBJECTIVE: To assess the feasibility and accuracy of inert gas rebreathing (IGR) pulmonary blood flow (Qp) estimation in mechanically ventilated pediatric patients, potentially providing real-time noninvasive estimates of cardiac output. STUDY DESIGN: In mechanically ventilated patients in the pediatric catheterization laboratory, we compared IGR Qp with Qp estimates based upon the Fick equation using measured oxygen consumption (VO2) (FickTrue); for context, we compared FickTrue with a standard clinical short-cut, replacing measured with assumed VO2 in the Fick equation (FickLaFarge, FickLundell, FickSeckeler). IGR Qp and breath-by-breath VO2 were measured using the Innocor device. Sampled pulmonary arterial and venous saturations and hemoglobin concentration were used for Fick calculations. Qp estimates were compared using Bland-Altman agreement and Spearman correlation. RESULTS: The final analysis included 18 patients aged 4-23 years with weight >15 kg. Compared with the reference FickTrue, IGR Qp estimates correlated best and had the least systematic bias and narrowest 95% limits of agreement (results presented as mean bias ±95% limits of agreement): IGR -0.2 ± 1.1 L/min, r = 0.90; FickLaFarge +0.7 ± 2.2 L/min, r = 0.80; FickLundell +1.6 ± 2.9 L/min, r = 0.83; FickSeckeler +0.8 ± 2.5 L/min, r = 0.83. CONCLUSIONS: IGR estimation of Qp is feasible in mechanically ventilated patients weighing >15 kg, and agreement with FickTrue Qp estimates is better for IGR than for other Fick Qp estimates commonly used in pediatric catheterization. IGR is an attractive option for bedside monitoring of Qp in mechanically ventilated children.


Asunto(s)
Gasto Cardíaco , Pruebas de Función Cardíaca/métodos , Respiración Artificial , Adolescente , Pruebas Respiratorias , Niño , Preescolar , Femenino , Humanos , Masculino , Gases Nobles/administración & dosificación , Consumo de Oxígeno , Respiración , Adulto Joven
10.
J Cardiothorac Vasc Anesth ; 29(1): 95-100, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25440622

RESUMEN

OBJECTIVE: Superior vena cava pressure after the bidirectional Glenn operation usually is higher than that associated with the preceding shunt-dependent circulation. The aim of the present study was to determine whether the acute elevation in central venous pressure was associated with changes in cerebral oxygenation and perfusion. DESIGN: Single-center prospective, observational cohort study. SETTING: Academic children's hospital. PARTICIPANTS: Infants with single-ventricle lesions and surgically placed systemic-to-pulmonary artery shunts undergoing the bidirectional Glenn operation. INTERVENTIONS: Near-infrared spectroscopy and transcranial Doppler sonography were used to measure regional cerebral oxygen saturation and cerebral blood flow velocity. MEASUREMENTS AND MAIN RESULTS: Mean differences in regional cerebral oxygen saturation and cerebral blood flow velocity before anesthetic induction and shortly before hospital discharge were compared using the F-test in repeated measures analysis of variance. In the 24 infants studied, mean cerebral oxygen saturation increased from 49%±2% to 57%±2% (p = 0.007), mean cerebral blood flow velocity decreased from 57±4 cm/s to 47±4 cm/s (p = 0.026), and peak systolic cerebral blood flow velocity decreased from 111±6 cm/s to 99±6 cm/s (p = 0.046) after the bidirectional Glenn operation. Mean central venous pressure was 8±2 mmHg postinduction of anesthesia and 14±4 mmHg on the first postoperative day and was not associated with a change in cerebral perfusion pressure (p = 0.35). CONCLUSIONS: The bidirectional Glenn operation in infants with a shunt-dependent circulation is associated with an improvement in cerebral oxygenation, and the lower cerebral blood flow velocity is likely a response of intact cerebral autoregulation.


Asunto(s)
Puente Cardiopulmonar/normas , Circulación Cerebrovascular , Procedimiento de Fontan/normas , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Puente Cardiopulmonar/métodos , Estudios de Cohortes , Femenino , Procedimiento de Fontan/métodos , Humanos , Lactante , Masculino , Estudios Prospectivos
11.
Ann Surg ; 257(3): 403-12, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23059501

RESUMEN

Nerve damage takes place during surgery. As a consequence, significant numbers (10%-40%) of patients experience chronic neuropathic pain termed surgically induced neuropathic pain (SNPP). The initiating surgery and nerve damage set off a cascade of events that includes both pain and an inflammatory response, resulting in "peripheral and central sensitization," with the latter resulting from repeated barrages of neural activity from nociceptors. In affected patients, these initial events produce chemical, structural, and functional changes in the peripheral and central nervous systems (CNS). The maladaptive changes in damaged nerves lead to peripheral manifestations of the neuropathic state-allodynia, sensory loss, shooting pains, etc, that can manifest long after the effects of the surgical injury have resolved. The CNS manifestations that occur are termed "centralization of pain" and affect sensory, emotional, and other (eg, cognitive) systems as well as contributing to some of the manifestations of the chronic pain syndrome (eg, depression). Currently there are no objective measures of nociception and pain in the perioperative period. As such, intermittent or continuous pain may take place during and after surgery. New technologies including direct measures of specific brain function of nociception and new insights into preoperative evaluation of patients including genetic predisposition, appear to provide initial opportunities for decreasing the burden of SNPP, until treatments with high efficacy and low adverse effects that either prevent or treat pain are discovered.


Asunto(s)
Encéfalo/fisiopatología , Neuralgia/fisiopatología , Nociceptores/fisiología , Dolor Postoperatorio/fisiopatología , Humanos , Neuralgia/complicaciones , Dolor Postoperatorio/etiología
13.
Circulation ; 122(3): 245-54, 2010 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-20606124

RESUMEN

BACKGROUND: Near-infrared spectroscopy monitoring of cerebral oxygen saturation (rSo(2)) has become routine in many centers, but no studies have reported the relationship of intraoperative near-infrared spectroscopy to long-term neurodevelopmental outcomes after cardiac surgery. METHODS AND RESULTS: Of 104 infants undergoing biventricular repair without aortic arch reconstruction, 89 (86%) returned for neurodevelopmental testing at 1 year of age. The primary near-infrared spectroscopy variable was the integrated rSo(2) (area under the curve) for rSo(2)

Asunto(s)
Cardiopatías Congénitas/cirugía , Hemodilución , Imagen por Resonancia Magnética , Monitoreo Intraoperatorio/métodos , Oximetría/métodos , Encéfalo/irrigación sanguínea , Encéfalo/crecimiento & desarrollo , Encéfalo/patología , Puente Cardiopulmonar , Circulación Cerebrovascular , Desarrollo Infantil , Discapacidades del Desarrollo/prevención & control , Femenino , Estudios de Seguimiento , Hemosiderina/metabolismo , Humanos , Hipotermia Inducida , Lactante , Recién Nacido , Modelos Lineales , Masculino , Oxígeno/sangre , Trastornos Psicomotores/prevención & control , Espectroscopía Infrarroja Corta
14.
Paediatr Anaesth ; 21(5): 594-603, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-20880157

RESUMEN

The evolving demographics, outcomes, and anesthetic management of pediatric heart transplant recipients are reviewed. As survival continues to improve, an increasing number of these patients will present to our operating rooms and sedation suites. It is therefore important that all anesthesiologists, not only those specialized in cardiac anesthesia, have a basic understanding of the physiologic changes in the transplanted heart and the anesthetic implications thereof.


Asunto(s)
Anestesia/métodos , Trasplante de Corazón/estadística & datos numéricos , Sistema del Grupo Sanguíneo ABO , Anestésicos/efectos adversos , Cardiomiopatías/mortalidad , Cardiomiopatías/cirugía , Causas de Muerte , Niño , Preescolar , Contraindicaciones , Procedimiento de Fontan , Rechazo de Injerto/epidemiología , Corazón/fisiología , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/cirugía , Trasplante de Corazón/efectos adversos , Trasplante de Corazón/mortalidad , Trasplante de Corazón/fisiología , Humanos , Lactante , Recién Nacido , Factores Socioeconómicos , Sobrevida , Resultado del Tratamiento , Listas de Espera/mortalidad
15.
J Extra Corpor Technol ; 43(2): 79-83, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21848177

RESUMEN

Most institutions performing cardiopulmonary bypass for congenital heart disease patients use an integrated hard shell cardiotomy and venous reservoir attached to an oxygenator. It is of paramount importance that the integrated reservoir be vented so as not to cause pressurization. A pressurized sealed cardiotomy has been reported to occur secondary to issues with vacuum assisted venous drainage systems as well as improper venting in general. We report a case of air embolus caused by retrograde propulsion of air through the venous line secondary to a pressurized cardiotomy reservoir in a patient with Fontan circulation. The mechanism of cardiotomy pressurization is described, and the scenario simulated in a mock circuit.


Asunto(s)
Embolia Aérea/etiología , Análisis de Falla de Equipo , Procedimiento de Fontan/efectos adversos , Procedimiento de Fontan/instrumentación , Preescolar , Embolia Aérea/terapia , Cabeza/diagnóstico por imagen , Humanos , Complicaciones Intraoperatorias , Presión , Tomografía Computarizada por Rayos X
16.
IEEE Trans Biomed Eng ; 67(4): 1007-1018, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31295101

RESUMEN

OBJECTIVE: To enable reliable cerebral embolic load monitoring from high-intensity transient signals (HITS) recorded with single-channel transcranial Doppler (TCD) ultrasound. METHODS: We propose a HITS detection and characterization method using a weighted-frequency Fourier linear combiner that estimates baseline Doppler signal power. An adaptive threshold is determined by examining the Doppler signal power variance about the baseline estimate, and HITS are extracted if their Doppler power exceeds this threshold. As signatures from multiple emboli may be superimposed, we analyze the detected HITS in the time-frequency (TF) domain to segment the signals into individual emboli. A logistic regression classification approach is employed to classify HITS into emboli or artifacts. Data were collected using a commercial TCD device with emboli-detection capabilities from 12 children undergoing mechanical circulatory support or cardiac catheterization. A subset of 696 HITS were reviewed, annotated, and split into training and testing sets for developing and evaluating the HITS classification algorithm. RESULTS: The classifier yielded 98% and 96% sensitivity for 100% specificity on training and testing data, respectively. The TF approach decomposed 38% of candidate embolic signals into two or more embolic events that ultimately account for 69% of the overall embolic counts. Our processing pipeline resulted in highly accurate emboli identification and produced emboli counts that were lower (by a median of 64%) compared to the commercial ultrasound system's estimates. SIGNIFICANCE: Using only single-channel, single-frequency Doppler ultrasound, the proposed method enables sensitive detection and segmentation of embolic signatures. Our approach paves the way toward accurate real-time cerebral emboli monitoring.


Asunto(s)
Embolia Intracraneal , Ultrasonografía Doppler Transcraneal , Algoritmos , Artefactos , Cateterismo Cardíaco , Niño , Humanos , Embolia Intracraneal/diagnóstico por imagen
17.
Circulation ; 117(14): 1842-8, 2008 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-18362236

RESUMEN

BACKGROUND: Quantitative assessment of ventricular volumes and mass in pediatric patients with single-ventricle physiology would aid clinical management, but it is difficult to obtain with 2-dimensional echocardiography. The purpose of the present study was to compare matrix-array 3-dimensional echocardiography (3DE) measurements of single-ventricle volumes, mass, and ejection fraction with those measured by cardiac magnetic resonance (CMR) in young patients. METHODS AND RESULTS: Twenty-nine patients (median age, 7 months) with a functional single ventricle undergoing CMR under general anesthesia were prospectively enrolled. The 3DE images were acquired at the conclusion of the CMR. Twenty-seven of 29 3DE data sets (93%) were optimal for 3DE assessment. Two blinded and independent observers performed 3DE measurements of volume, mass, and ejection fraction. The 3DE end-diastolic volume correlated well (r=0.96) but was smaller than CMR by 9% (P<0.01), and 3DE ejection fraction was smaller than CMR by 11% (P<0.01). There was no significant difference in measurements of end-systolic volume and mass. The 3DE interobserver differences for mass and volumes were not significant except for ejection fraction (8% difference; P<0.05). Intraobserver differences were not significant. CONCLUSIONS: In young pediatric patients with a functional single ventricle, matrix-array 3DE measurements of mass and volumes compare well with those obtained by CMR. 3DE will provide an important modality for the serial analysis of ventricular size and performance in young patients with functional single ventricles.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ventrículos Cardíacos/anomalías , Síndrome del Corazón Izquierdo Hipoplásico/diagnóstico por imagen , Imagen por Resonancia Magnética , Miocardio/patología , Volumen Sistólico , Niño , Preescolar , Ecocardiografía Tridimensional/instrumentación , Femenino , Humanos , Síndrome del Corazón Izquierdo Hipoplásico/patología , Procesamiento de Imagen Asistido por Computador , Lactante , Recién Nacido , Masculino , Variaciones Dependientes del Observador , Tamaño de los Órganos , Reproducibilidad de los Resultados , Transductores
18.
Anesth Analg ; 108(4): 1122-31, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19299774

RESUMEN

BACKGROUND: We examined changes in cerebral oxygen saturation during infant heart surgery and its relationship to anatomic diagnosis and early outcome. METHODS: Regional cerebral oxygen saturation (rSO(2)) was measured by near-infrared spectroscopy in 104 infants undergoing biventricular repair without aortic arch obstruction as part of a randomized trial of hemodilution to a hematocrit of 25% vs 35%. RESULTS: Before cardiopulmonary bypass (CPB), infants with tetralogy of Fallot had higher rSO(2) values compared to those with D-transposition of the great arteries (D-TGA) or ventricular septal defect (P < 0.001). During CPB cooling, low flow, and at the termination of CPB, D-TGA subjects had the highest rSO(2) values (P < 0.001). There were no significant associations between intraoperative rSO(2) and early postoperative outcomes after adjustment for diagnosis. In 39 D-TGA subjects with > or =5 min of deep hypothermic circulatory arrest (DHCA), there was no correlation between the rSO(2) (91% +/- 6%) or hematocrit (29.2% +/- 5.5%) at the onset of arrest and the rate of decline in rSO(2) during arrest. CONCLUSIONS: Intraoperative rSO(2) varies according to anatomic diagnosis but accounts for very little of the variance in early outcome. As measured by frontal near-infrared spectroscopy, higher levels of hematocrit and current perfusion techniques appear to provide an adequate oxygen reservoir prior to relatively short periods of DHCA.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Circulación Cerebrovascular , Cardiopatías Congénitas/cirugía , Monitoreo Intraoperatorio/métodos , Oximetría/métodos , Oxígeno/sangre , Espectroscopía Infrarroja Corta , Puente Cardiopulmonar , Enfermedades del Sistema Nervioso Central/sangre , Enfermedades del Sistema Nervioso Central/etiología , Enfermedades del Sistema Nervioso Central/fisiopatología , Paro Circulatorio Inducido por Hipotermia Profunda , Femenino , Cardiopatías Congénitas/sangre , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/fisiopatología , Hematócrito , Hemodilución , Hemodinámica , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
19.
Anesth Analg ; 107(6): 1848-54, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19020129

RESUMEN

Patients with congenital supravalvular aortic stenosis and associated peripheral pulmonary artery stenoses, the majority of whom have Williams-Beuren syndrome, are inherently at risk for development of myocardial ischemia. This is particularly true in the setting of procedural sedation and anesthesia. The biventricular hypertrophy that accompanies these lesions increases myocardial oxygen consumption and compromises oxygen delivery. In addition, these patients often have direct, multifactorial compromise of coronary blood flow. In this article, we review both the pathophysiology of congenital supravalvular aortic stenosis and the literature regarding sudden death in association with sedation and anesthesia. Recommendations as to preoperative assessment and management of these patients are made based on the best available evidence.


Asunto(s)
Anestesia/efectos adversos , Estenosis Aórtica Supravalvular/congénito , Muerte Súbita Cardíaca/etiología , Estenosis Aórtica Supravalvular/complicaciones , Estenosis Aórtica Supravalvular/fisiopatología , Circulación Coronaria , Estenosis Coronaria/etiología , Humanos , Isquemia Miocárdica/etiología , Síndrome de Williams/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA